CO2 Carbon Dioxide Sensor

Similar documents
Technical data sheet TDS0060

PREMIER PLATINUM INFRARED GAS SENSOR

LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions ***

Technical data sheet TDS0034

PREMIER PLATINUM INFRARED TRIPLE RANGE HYDROCARBON SENSOR Exd Certified versions *** Available in EN50271 / SIL1 Certified versions ***

Key Features. General Description

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

IR15 Dual Gas Series Datasheet

IR25 Dual Gas Series Datasheet

ALTAIR 5X Multigas Detector Product Specification

Model 1000 H 2 S E-Chem/ CO 2 Process Analyzer

Analog Input Module IC670ALG630

Pac Ex 2. Elegant and smart Explosive hazards and lack or surplus of oxygen under control

Datasheet: K-22 LO Sensor

REGARD. REGARD 4-20 AND Ex CHANNEL CARDS INSTALLATION AND OPERATING MANUAL (FOR ATEX VERSION CARDS)

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

DGS - Danfoss Gas Sensor Check / Calibration Procedure

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

IR1 Single Gas Series Datasheet

Integrated IR Datasheet

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

APN0064.P65 Issue 01-06/2000 COMPARISON OF OPTICAL DETECTION SYSTEMS FOR INFRARED HYDROCARBON GAS DETECTION

Certificate: / 29 April 2014

Infrared Carbon Dioxide Sensor Module CM1107-Dual Beam

SprintIR -6S CO2 Sensor

Operating Instructions and Maintenance Manual

Detcon MicroSafe. IR-640 Carbon Dioxide Sensor (0-5%CO2) IR642 Carbon Dioxide Sensor (10%-100%) Operator s Installation & Instruction Manual

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

Intelligent Infrared Carbon Dioxide Module (Model: MH-Z14A)

ST-IAM Sensor Transmitter Integrated Area Monitor. Check / Calibration Procedure* 10 ASH (1)

Infrared Carbon Dioxide Sensor Module CM1106SL

Lamp Supply (Recommended)

Understanding total measurement uncertainty in power meters and detectors

Module Features are-configurable, no module jumpers to set

Dräger PIR 7200 Toxic Gas Detection Transmitter

DESIGN MANUAL. The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0)

SprintIR -W CO2 Sensor

Multifunction IAQ Monitor

Infrared Moisture Balance (FD-800)

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

OEM REFRIGERANT GAS SENSORS for Leak Detection & Measurement

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

The product can be worked together with our wireless controller to control a ventilator, air cleaning device, or

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Operation and Maintenance Manual

Beam Detectors. The 6500 Series

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

-smartgas- A new low cost infrared gas sensor for domestic and automotive applications

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Air Quality Sensors. Particle Matter, CO 2, Humidity, Temperature and Dust Products. OEM Sensor Components for Air Quality and Environmental Control

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Advance Optima Module Magnos 17

FIRERAY 5000 range USER GUIDE

CHILLGARD M-100. Refrigerant Sensor. Operating Manual. Order No.: /02

FlameGard 5 MSIR HART

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

Intelligent addressable fire alarm control panel

Dräger X-dock 5300/6300/6600 Calibration and Bump Testing

PRODUCT CONFORMITY CERTIFICATE

MGD Murco Gas Detector. Check / Calibration Procedure* 10 ASH (1)

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

SEC Millenium Carbon Dioxide Gas Detector

Hydrocarbon Gas Detector

Endura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer

AT-G-DETECT Gas Sensing System

ADPRO PRO Series by Xtralis

HGM300/RDM800 PREVENTATIVE MAINTENANCE AND TECHNICAL SUPPORT. SECTION 1 HGM300 CPU reset, RDM800 CPU reset, WARM UP notes and HGM300 Self Test

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

RS Pro Infrared Temperature Sensor

CRIOTEL. The complete solution for local and remote monitoring of cryogenic tanks under pressure

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Certificate: _01 / 22 March 2013

OVEN INDUSTRIES, INC.

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

MICROCAPSTAR End-Tidal CO 2 Analyzer Instruction Manual

Datasheet CozIR -A CO2 Sensor

I/A Series 716C 1/16 DIN Temperature Controller

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

E1000 Portable gas detector

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Industrial Grade Gas Detection Detecting The Difference

portable gas analyser

Zone Terminal, 2-fold, FM MT/U , GH Q R0111

Temperature-Relay TR210

600 Range Dialer Installation Manual. Version 1.0

User Guide OI/FEX100HART EN Rev. A. WaterMaster FEX100 HART Field Device Specification

FDA241, FDA221 Siemens ASD

GAS MONITOR Model Model

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Model D12-IR. Digital Gas Transmitter...

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Transcription:

Environmental Devices Corporation Technical Data Sheet P/N HS-C02-6000 CO2 Carbon Dioxide CO2 Carbon Dioxide Sensor DESCRIPTION Patent Numbers Great Britain GB 2 401 432 & GB 2 403 291 Europe EP 1544603 & EP 1818667-Pending France EP [ FR ] 1544603 Germany EP [ DE ] 1544603 Italy EP [ I ] I1544603 Switzerland EP [ CH ]1544603 USA 7, 244, 939 Other World Patents Pending CO2 P/N HS-C02-6000 infrared sensors operate by using the NDIR principle to monitor the presence of target gas. The sensor contains a long life tungsten filament infrared light source, an optical cavity into which gas diffuses, a dual temperature compensated pyroelectric infrared detector, an integral semiconductor temperature sensor and electronics to process the signals from the pyroelectric detector. Environmental Devices Corporation 4 Wilder Drive- Bldg 15 Plaistow, N.H.- 03865 U.S.A

Environmental Calibration Devices options Corporation 4 Wilder Drive- Bldg 15 Plaistow, N.H.- 03865 U.S.A Environmental Devices Corp. recommends a maximum interval of 12 months between calibration checks. A small amount of zero drift can be accommodated by re-zeroing the gas detector against the sensor. The degree of drift that is acceptable should be determined by the user. Note that the subsequent change in gas reading will be greater than the change in zero reading. If the sensor requires either a Zero or Span adjustment, there are three methods that can be used: 1) By using the Premier Configuration Unit When used in conjunction with dedicated PC software, this device uses the data communication pins on the sensor to provide a means of calibration. Refer to data sheet TDS0043 for additional information. 2) By using the data communications pins and software written in accordance with the protocol supplied by Environmental Devices Corp. 3) By using the "Manual Calibration" feature available with firmware version 1.5.2R. Zero and Span operations can be performed by momentarily connecting the data communication pins to the negative supply pin. Refer to data sheet CO2 for full instructions. The Manual Calibration option must be specified when the sensors are ordered. Sensor warm-up time When power is first applied to the sensor, the voltage at the output pin is held at a predetermined level. The default setting for this start-up value is the zero gas value. This condition is maintained for a default warm-up time of 15 seconds, after this time the output voltage represents the calculated gas value. Sensors can take up to 1 minute to indicate the correct gas reading. Note: the sensor can output any reading from -100% FSD to +200% FSD in the first minute. The output value that is read using the communications pins is always held at zero during the warm-up time. Both the voltage at the output pin during the warm-up time, and the duration of the warm-up time can be pre-programmed to alternative values at the time of ordering sensors. Temperature transients and gas flow rates. The Premier sensor employs a pyroelectric detector, the output from which can be disrupted by sudden changes in temperature. If there is an excessive change in the ambient temperature, gas sample temperature or flow rate, then the output signal will be momentarily frozen. Correct operation is restored when the effects of the transient have settled. Rates of change in the ambient temperature should be restricted to 2 C/minute and gas flow rates kept below 600 cc/minute.

Power supply considerations The sensor power supply rise time must be less than 50 ms to ensure correct operation. Operation outside the range of 3 5 V dc will result in either fault indication, or the sensor will not function correctly. Sensor over-range condition The sensor will continue to provide an output up to 200% of the full scale value; at this point the reading is clamped, regardless of any further increase in detected gas level. The linearity of the output is only guaranteed up to the full scale for the sensor; the overrange condition should therefore be determined and indicated by the host instrument. Sensor fault indication The sensor constantly performs checks on the internal memory contents, the incoming supply voltage and the analogue signal values. These checks are used to ensure that the sensor is operating within its correct parameters, and that no internal faults have developed. If a fault condition is detected, the output value is set to -100% FSD. In the case of a sensor with a voltage output that is scaled, 0.4 2.4V, for example, the output will be set to 0V under fault conditions. It is not recommended to choose an output voltage of 0V for zero-gas, because the fault condition cannot then be distinguished from the zero-gas condition. The output value that is read when using the communications pins, instead of the voltage output pin, will be set to -100% FSD under fault conditions. As mentioned in the Sensor warm-up time section above, the voltage at the output pin during the warm-up time can be specified when ordering sensors. It should be noted that if a start-up voltage is chosen that represents the zero-gas condition, then should a fault subsequently develop leaving the sensor unable to drive the output to -100% FSD, this condition cannot be detected by the host instrument. The start-up voltage that is equivalent to zero-gas was chosen as the default setting because, in a large number of applications, the host instrument would otherwise indicate fault during the warm-up period. Digital interface The digital communication pins RX and TX operate at a 2.8V logic level. When interfacing to external circuitry that uses a higher voltage level it is necessary to limit the current that can flow. The external voltage level should be 5V maximum and a 3K3 resistor should be used in series with each communication pin.

Environmental Devices Corporation 4 Wilder Drive- Bldg 15 Plaistow, N.H.- 03865 U.S.A