Inverter Wall Mounted

Similar documents
Inverter Wall Mounted

Inverter Wall Mounted

PLXRMM1606B. Wall Mounted. FTN-A Series. COOLING ONLY [50Hz] V

Inverter Wall Mounted Series

Floor Standing. FV Series PLXSPH1502. COOLING ONLY [60Hz]

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

Split Type Air Conditioners FTNE-M Series Cooling Only [50 Hz]

PCR0709A. Options. Indoor unit

A wider lineup of DC Inverter and Non-Inverter air conditioners with 19 models is currently available. You can choose whichever that fits your

CHI NHAÙNH HAØ NOÄI Taàng 12, toøa nhaø Ocean Park Tower, 1 Ñaøo Duy Anh, Quaän Ñoáng Ña, Haø Noäi

DAIKIN Modular Inverter Air Cooled Chiller

LV Series. SEER 20+ Wall Mount Heat Pump

Inverter Y Series.

KE Series. SEER 14+ Wall Mount Heat Pump or Cooling Only

PLXSID1605. Warning HEAD OFFICE :

Non Inverter Wall Mounted Series

Split Type Air Conditioners

PCXGA13. Air-Cooled PRODUCT SYSTEM. Residential. Light Commercial. All Product. Commercial / Industrial. Catalogue. For internal reference only R22

OPERATING MANUAL. Operating Manual Handset Wireless. English. OM-GS (0)-DAIKIN Part No.: R MODE TURBO TIMER CANCEL

Up to SEER 26.1 Wall Mount Heat Pump

Si REMOVAL PROCEDURE. 2.5/3.2/3.5 kw Class. Outdoor Unit Inverter Pair Type

Daikin air conditioners for your home

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

The Comfort and Luxury You Deserve

OPERATING MANUAL. Before using your air conditioner, please read this operating manual carefully and keep it for future reference.

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

Air Conditioning Product Brochure 2015/2016. Classic Series Hi-Wall Split Systems. Everyday Cool

w w w. d a i k i n. e u ATXS-E

Si REMOVAL PROCEDURE. 4.0/5.0/5.2/5.8/6.8/7.5 kw Class. Outdoor Unit Inverter Multi Type

Ceiling Mounted Cassette ( Round Flow with Sensing ) Type

AIR PURIFICATION SOLUTIONS PCAPNZ1017 AIR PURIFIER

Daikin air conditioners for your home

HI-WALL SPLIT SYSTEMS

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

FAQ. Wall Mount Heat Pump or Cooling Only

Split Type Air Conditioners

for your home FTYN-GX FT(Y)N-F

SPLIT SYSTEM HEATING AND COOLING SOLUTIONS FROM DAIKIN. Energy efficient heating and cooling solutions for your home

DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

The Comfort and Luxury You Deserve

Air conditioners Cooling only

Daikin air conditioners for your home

Including mounting plate. General Rating Nameplate. Terminal strip with earth terminal

LV Series. SEER 15+ Concealed Built in Heat Pump

DSS SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEMS. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

RC-0219-A. Single-Split Non Inverter Series

PHOTOCATALYTIC AIR CLEANER

MULTI SYSTEM TECHNOLOGY. 1. Ururu Humidification PART 2 - URURU MULTI

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

FBQ. DC Duct Heat Pump or Cooling Only

FTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR

Wall Mounted Split Systems G-Series AP - MWM - G - 06A

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

SiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

BENEFIT FROM LOWER FUEL COSTS.

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

Service Manual. Inverter Pair Floor Standing Type K-Series. Draft. SiBE [Applied Models] Inverter Pair : Heat Pump

DAIKIN AIR PURIFIER IMPROVED BREATHING COMFORT FOR ALLERGY AND ASTHMA SUFFERERS ABSOLUTE COMFORT

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Pure air. Because Daikin cares

DAIKIN FAQ SERIES HEATING & COOLING SYSTEMS. INDOOR WALL-MOUNTED UNITS Up to 18.6 SEER / Up to 9.4 HSPF Up to 12.7 EER

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

The Comfort and Luxury You Deserve

Service Manual. Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series. SiBE05-722_C

DAIKIN FCQ SERIES HEATING & COOLING SYSTEMS. ROUNDFLOW CEILING-MOUNTED CASSETTE Up to 18.6 SEER / Up to 10.2 HSPF Up to 13.0 EER

DAIKIN S URURU SARARA

AIR CONDITIONING REVERSE-CYCLE INVERTER

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems

DESIGN & TECHNICAL MANUAL

Brief exposure to greenery in urban environments can relieve stress levels and your well-being.

HEAT PUMPS BY DAIKIN. Energy efficient heating and cooling solutions for your home

AIR CONDITIONING AGAIN, AGAIN & AGAIN ONLY PANASONIC GETS 5 STARS #AIRTHATMOVESYOU

DAIKIN FBQ DUCTED SERIES HEATING & COOLING SYSTEMS. DC DUCT-CONCEALED Up to 17.5 SEER / Up to 10.6 HSPF Up to 13.0 EER

Operating Instructions Air Conditioner

Heat Pump Range 2012/2013

Hi-spec Design model. Photo : LT series

Technology that works fast. Hi-Wall Split Systems

About Daikin: WARNINGS:

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR

Inverter console UFV system. Compact design and personalised air flow selection

SiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump

AIR CONDITIONER MALAYSIA S FIRST REVERSE CYCLE SOLAR PV-INVERTER

Pure Efficiency Meets Healthy Living NEW 2013

Daikin Sensira R-32. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort

Technology that works fast. Hi-Wall Split Systems

Full range. A class energy label. for your home WALL MOUNTED UNIT. air to air heat pumps. FTXS-G

EDAU Air Purifiers. Engineering Data MC70LPVM

we care about Better Air

Pure comfort & design

Daikin 19 SERIES SINGLE ZONE HEATING & COOLING SYSTEMS

Split System Air Conditioning

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

Instruction Manual FEEL THE ENERGY. FEEL THE FRESHNESS.

Owner s Manual. Airgle Personal Air Purifier ( Model: AG25 )

SPLIT SYSTEM HEATING AND COOLING SOLUTIONS FROM DAIKIN. Energy efficient heating and cooling solutions for your home

Air Conditioning range Split System Window/Wall

Pure comfort & design

Transcription:

Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation. PLXRHK1610 Caution Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Read the User s Manual carefully before using this product. The User s Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer. Cautions on product corrosion 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor. Inverter Wall Mounted DEALER DAIKIN MALAYSIA SDN. BHD. Lot 60334, Persiaran Bukit Rahman Putra 3, Taman Perindustrian Bukit Rahman Putra, 47000 Sungai Buloh, Selangor Darul Ehsan, Malaysia. www.daikinmalaysia.com Cooling Only FTWK-A Series DAIKIN INDUSTRIES, LTD. Head Office: Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan. Specifications, designs and other content appearing in this brochure are current as of March 2016 but subject to change without notice. All rights reserved.

Compact & Light Outdoor Servicing & Installation Features Width: 765 Easy access for wiring installation at back panel. Valve positioned at back top panel for easy servicing. Height: 420 Ergonomic handler position for transportation and installation. U-Shape base pan leg front eases installer in fixing unit position. Installer may fix the bolt before installing the unit. Depth: 291 Weight: 24kg Drain hose located at lowest base point of outdoor to ensure smooth water drainage. Drain pan panel for effective water drainage. 1 2

What is Inverter technology? Inverter system ensures faster cooling with significant energy saving. Moreover, it helps to maintain consistent temperature in the room, makes you feel comfortable all the time especially when you are sleeping. DC Inverter Daikin calls an inverter model that is equipped with a DC motor DC Inverter. A DC motor offers higher efficiency than an AC motor. A DC motor uses the power of magnets to attract and repel to generate rotation. A DC motor that is equipped with high-power neodynium magnets, which enables even greater efficiency, is called a Reluctance DC motor. Swing Compressor Thanks to its smooth rotation, the swing compressor decreases friction and vibration. It also prevents the leakage of refrigerant gas during compression. These advantages provide quiet and efficient operation. The swing compressor can reduce operational vibration and sound because its piston moves smoothly inside the compressor. Reluctance DC motor for compressor Daikin DC Inverter models are equipped with the Reluctance DC motor for compressors. The Reluctance DC motor uses 2 different types of torque, neodymium magnet¹ and reluctance torque². This motor saves energy by generating more power with a smaller electric current than AC or conventional DC motors. It is more efficient at the low frequencies most coonly used by air conditioners³, improving efficiency by approximately 20%. Neodymium magnets are used in the pink-coloured area. 1. A neodymium magnet is approximately 10 times stronger than a standard ferrite magnet. 2. The torque created by the change in power between the iron and magnet parts. 3. The frequency range used by air conditioners during periods of stable operation. This is the range in which air conditioners operate for the longest periods. Advantages of Inverter technology Superior comfort Higher efficiency Fixed speed (non-inverter) systems operate by compressor start-stop cycles which consumes more energy and have higher variance of the room temperature. Uncomfortable (Energy ) Comfortable Uncomfortable (Energy ) Set Temperature Low starting current Taking the advantages of the ability to modulate the compressor speed, inverters are designed to operate with soft start feature. The compressor motor does not require high current during start up. Powerful operation Better energy savings Daikin Inverter Steady Temperature Non Inverter High Temperature Flexible installation The extended piping length promotes flexible installation Model FTWK25AXV1H RWK25AXV1H FTWK35AXV1H RWK35AXV1H Precharge length (m) Max. length (m) Max. elevation (m) 7.5 20 10 7.5 20 10 Note: Additional refrigerant is required if the piping is longer than the pre-charge length. For details, kindly refer to the installation manual. Flexible performance, rapid response time After quickly reaching set temperature, the inverter system constantly adjusts and fine-tunes the cooling capacity to prevent undesired temperature swings. Room comfort level is constantly maintained even when the number of people in the room increases or decreases. Room Temperature Set Temperature Inverter System Precise & Stable Temperature Control 3 4 Conventional System Time

Titanium Apatite Photocatalytic Air Purifying Filter Micron-scale fibers trap dust while titanium apatite absorbs organic contaminants such as bacteria and viruses. In addition, the titanium oxide is activated by natural light, allowing it to break down and eliminate odours. The filter effectively deactivates bacteria and viruses. It lasts for three years without replacement if washed about once every six months. Titanium Oxide Photocatalytic deodorizing filter Absorption of dangerous airborne particles like dust, pollen and cigarette smoke Dissolves odour, bacteria and virus Mechanism of photocatalyst: - Titanium Oxide is activated by exposure to light - Becomes highly oxidative - Dissolves absorbed substances into harm less water(h 2 O) and carbon dioxide (CO 2 ). Stylish Flat Panel An ideal blend of style and functionality. The front panel is designed for contemporary style without compromising on function. Air intake area is designed to ensure smooth air flow profile for better sound quality and optimized volume. Sleep Mode Pressing the Sleep button activates the Sleep Mode. This function prevents excessive cooling for a pleasant sleep. Cooling Set temp. before Sleep mode begins to operate Time + 30 mins 30 mins Sleep mode turns on Cooling operation: 1) After 30 minutes, room temperature is raised by 0.5 C. 2) After 60 minutes, room temperature is raised by 0.5 C. 3) After 120 minutes, room temperature is raised by 1 C. + 60 mins + Absorption power is more than doubled, dissolution force is increased. Lower Sound Level With up to five selectable fan speeds, users are given more choices. By selecting Quiet mode, the sound pressure level can be reduced down to an unobtrusive 21dBA. * This product is not a medical device, medical treatment device or therapeutic goods. * This product is not intended to have any therapeutic use or to be used for the diagnosis, treatment relief or prevention of illness. * If you have a health concern or are not feeling well, please consult a health care professional. 21dBA is so quiet you can even hear whispers 20 Rustling of leaves 30 Pendulum of a wall clock 21dBA for FTWK25AXV1H; FTWK35AXV1H 40 Library 50 Normal office (dba) 5 6

Auto Random Restart with Last-State-Memory In the event of a sudden power failure during operation, unit restarts automatically in 64 different recovery timing patterns (within 180 seconds to 244 seconds) and the unit will operate based on the previous setting (operating mode, temperature setting and fan speed). This ensures that air conditioners in the same building resume randomly instead of all units resuming at the same time, preventing power surge after a blackout. Powerful Operation Powerful Operation is activated by pressing the Turbo button. Once activated, the air conditioner will run on full power with indoor fan running at maximum speed for 20 minutes. This enables the set temperature to be achieved faster. If Turbo and Sleep mode timer will be reset, it will resume after Turbo function is cleared. T room Easy-to-use Wireless Remote Controller Vertical auto-swing Glow-in-the-dark On/Off switch Fan speed selection: Low, Med, High, Auto Selectable Mode: Cool, Dry, Fan Turbo function Temperature setting: Up & down Quiet function Sleep mode function On timer setting Off timer setting Real time clock Power failure Power returns Operation Stop Restart T set BRC52A62 E 2 PROM Settings stored before power failure Start 20min 30min Anti-Corrosion Hydrophilic Gold Fin The outdoor unit s heat exchanger fins are constructed from anticorrosion hydrophilic gold fin. The anticorrosion fin increases the life span of the heat exchanger, especially when operating under corrosive and harsh environment. Optional - Control System Turbo function Cool, Dry, Fan mode Delay timer (1 or 2 hours) 7-days prograable timer Low, Med, High, Auto fan speed Real time clock and day display Temperature operate in ºC and ºF Swing function Quiet function Sleep function On/Off switch BRC51A62 7 8

Function Dictionary Comfortable Airflow Comfort Control Worry Free Specifications FTWK-AXV1H + RWK-AXV1H (Cooling only) Efficiency Data 25 35 Wide-Angle Louvers The smoothly curved Wide-Angle Louvers provide wide airflow coverage for effective operation no matter where the indoor unit is placed in a room. Vertical Auto-Swing (up and down) This function automatically moves the flaps up and down to distribute air across a room. Lifestyle Convenience New Powerful Operation New Powerful Operation boosts airflow to maximum volume for a 20-minute period. After this, the unit automatically returns to its previous settings. Indoor Unit On/Off Switch The unit can be conveniently started manually in the event the wireless remote controller is misplaced or the wireless remote controller batteries are not charged. Cleanliness Titanium Apatite Photocatalytic Air-Purifying Filter This filter contains the new photocatalytic material titanium apatite. While the filter s micron-level fibers trap dust, this photocatalyst absorbs and decomposes bacteria. The filter can be used for up to 3 years with proper maintenance. Washable Saranet Filter Removal of airborne dust particles through saranet filter ensures cleaner air supply. Timers Indoor Unit Quiet Operation Indoor unit operating sound levels are decreased by 3dB(A) from the Low setting fan speed using the wireless remote controller. Prograe Dry Function This function automatically reduces the level of humidity. Auto Fan Speed The microprocessor automatically controls fan speed to adjust the room temperature to the set temperature. 24-Hour On/Off Timer This timer can be preset to start and stop at any time within a 24-hour period. The air conditioner is started/ stopped simply by pressing the On/Off timer button on the wireless remote controller. Sleep Mode Pressing the Sleep button activates the Sleep Mode. After 30 minutes, room temperature is raised by 0.5 C. After 60 minutes, room temperature is raised by 0.5 C. After 120 minutes, room temperature is raised by 1 C. BLINK GOLD Auto Random Restart with Last-State-Memory In the event of a sudden power failure during operation, unit restarts automatically in 64 different recovery timing patterns (within 180 seconds to 244 seconds) and the unit will operate based on the previous setting (operating mode, temperature setting and fan speed). Self-Diagnosis Malfunctioning of air conditioner unit by blinking of LED lights for fast and easy maintenance. Anticorrosion Hydrophilic Gold Fin The outdoor unit s heat exchanger fins are constructed from anticorrosion hydrophilic gold fin. The anticorrosion fin increases the life span of the heat exchanger, especially when operating under corrosive and harsh environment. Cooling capacity Running current Power consumption Pre-charged piping length CSPF Energy efficiency grading Indoor unit Air flow Sound power level Dimension Net weight Filter type Outdoor unit MAX-MIN Cooling Cooling FTWK-AXV1H T/H/M/L/Q T/H/M/L/Q HxWxD RWK-AXV1H Btu/hr kw A 8700 (9300-3300) 10900 (11900-3700) 2.55 (2.75-0.98) 3.65 3.20 (3.50-1.10) 4.87 780 1040 Sound power level db(a) 50/44 51/44 Power supply Ph/V/Hz 1 phase, 220 V, 50 Hz (Power from Indoor) 1 phase, 220 V, 50 Hz (Power from Indoor) Dimension HxWxD 420x765x291 420x765x291 Net weight kg 24 25 Pipe connection Liquid Ø6.35 Ø6.35 Gas Ø9.52 Ø9.52 Drain Ø19.05 Ø19.05 Pre-charged R410A kg 0.65 0.90 refrigerant Piping Min. length m 2.5 2.5 Max. length m 20 20 Max. elevation m 10 10 Note: 1. Rated cooling capacities are based on the following conditions: Indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB. 2. Pre-charged refrigerant amount is based on standard pre-charged piping length of 7.5m. W m cfm db(a) kg 7.5 4.94 1 25 7.5 4.96 25 35 378/345/272/215/165 392/358/282/232/165 41/40/34/29/21 42/41/34/30/22 288x859x209 288x859x209 9 9 Titanium Apatite Photocatalytic Air Purifying Filter 1 35 Class 25/35 Class 25/35 comes with gold fin Wipe-Clean Flat Panel The flat panel models can be cleaned with only the single pass of a cloth across their smooth surface. The flat panel can also be easily removed for more thorough cleaning. 9 10