TW-Pro. Twin Wall Insulated Flue System EN T600 N1 W V2 L50040 G50 / O40

Similar documents
Twin Wall Installation Instructions And Maintenance Guide

PRICE LIST. UK s No 1 FLUE & CHIMNEY DISTRIBUTOR. VALID FROM 1st MAY - 31st AUGUST 2012

Easy to assemble. Silicone gasket sealed. Laser-welded seams. Smooth joint connections. 360 Lock-Tab secure rotation

By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference

SB Range Universal Oil Heaters with Automatic Ignition

FireFlexmaster. A Multi Fuel Flexible Chimney Liner 10 year Manufacturer Guarantee. 172 Ferry Lane, Stanley Wakefield, West Yorkshire, WF3 4LT

EXHAUST SYSTEMS COMMERCIAL CHIMNEY LINING SYSTEMS.

MODEL CF CEILING SUPPORTED CHIMNEY

Installation Instructions

VENT SYSTEM COMPONENTS

TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.

Technical and Dimensional Data. Saf-T Vent SC Plus

Mitchell Metal Products, Inc.

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

DuraPlus HTC. All-fuel, double-wall chimney system. ULC S629.

INSTALLATION INSTRUCTIONS

PelletVent Multi-fuel venting system. UL 641.

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

P P Gas Fireplace. P See Thru

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

NovaVent. Dimensional Data

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

Pellet Stove. Flex Pipe. Appliance Connector

Installation & Maintenance Instructions

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

Gas Stoves. C34-10 Direct Vent Gas Stove. Side wall E F. Back wall F E. Model C34-NG10 C34-LP10

5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

ICC Model VIC SINGLE WALL SPECIAL GAS VENT INSTALLATION AND MAINTENANCE INSTRUCTIONS

Ventis Direct Vent. Installation Instructions

EXCEL. ULTRABlack THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY NEVER EVER BUY ANOTHER STOVE PIPE

MX 200. MX-200 Technical Specifications FEATURES:

Installation Instructions

Venting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4

Installation and Maintenance Instructions

SEPARATED COMBUSTION WARNING

INSTALLATION & COMMISSIONING INSTRUCTIONS Model: 990 CH

200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual

CVS. Venting System for Category II, III, and IV gas appliances. Listed to UL-1738 and ULC S636.

PelletVent Pro horizontal Kit. PelletVent Pro. PelletVent Pro Vertical Kit - Cathedral. PelletVent Pro Pellet Chimney

The intelligent alternative for flue gas venting systems

ASX7-5-IOM-3 J

INSTALLATION AND MAINTENANCE INSTRUCTIONS. 1700ºF Air-Cooled and Insulated ECO-STEEL Chimney Size 13

MX 200. MX-200 Technical Specifications FEATURES:

Venting. Vent Material. Approved Venting Accessories Simpson Dura-Vent DV unless otherwise specified. Wall Thickness

INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING

TOYOTOMI U.S.A., INC. P.O. Box 176, Brookfield, CT

Esse B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL

Model IVSI Positive Pressure Venting Systems

CHAPTER 8 CHIMNEYS AND VENTS

Venting System For Pellet and Corn Stoves. PelletVent Pro. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

Flue & Flue Kits for NVx, VPC & NVS

INSTALLATION AND SERVICE MANUAL

INSTALLATION AND SERVICE MANUAL

Vertical Termination Part No: 3CGRVT 16 7/8" 18 Vent Pipe Extension Part No: 3CG18 9 7/8" Wall Hanger Part No: 3CGWH 7 7/8" 7 3/8"

ECO ICID INSTALLATION INSTRUCTIONS. Part of the MONIER GROUP

JEREMIAS GROUP. CE MARK according to EN / 2.

OUH Oil Unit Heater Range Controlling your working environment. heating ventilation integrity

DURAVENT POLYPRO VENTING PRODUCTS

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

2010 USA PRICE LIST.

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

BDM Direct Vent systems are for use with direct vent gas fired appliances.

CHIMNEYS AND VENTS CHAPTER 8

CHAPTER 8 CHIMNEYS AND VENTS

VP Pellet Pipe. For pellet burning stoves. FEATURES

ASX7-4-IOM-6 J

100% Manufactured in the UK. Nova SM. Twin wall, insulated stainless steel multi-fuel chimney system. Also suitable for fully condensing appliances

ZC Kit AGP Pellet Insert

Technical Guidance CE Marking of Metal Chimneys and Flues

Installation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro

SUBJECT: SELKIRK MODEL DT DIRECT VENT SYSTEM FOR PELLET & CORN FIRED APPLIANCES / TERMINATION CLEARANCES TO OPENINGS IN BUILDINGS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

CP+ Gas & Oil Cabinet Heater Range

Installation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

Pellet Vent INSTALLATION INSTRUCTIONS

flue&ducting Flue and Chimney Supplies NEXTDAY SAMEDAY DELIVERY DELIVERY

The New Remeha Quinta Pro Selection, Design and Installation of Flue Systems

Corn Flame Energy Corn Stove Model 3000

Installation and Maintenance Instructions

Installation and Maintenance Instructions

St. Croix Greenfield Installation Manual

SEPARATED COMBUSTION. General WARNING

OUH Suspended Oil Unit Heater

Installation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro

HAWK GAS STOVE. Installation and Servicing Instructions

Shasta Vent Inc All-Fuel HT Chimney Installation Instructions

City Series CV40E Gas Fireplace

Installation and Maintenance Instructions. Double Wall AL 29-4C Stainless Steel Special Gas Vent and Type L Vent

INSTALLATION INSTRUCTIONS

DT-M Direct-Temp for Multi Fuel L-Vent / Vent System for Pellet, Corn and other Bio-Fuel Burning Appliances

Importance of a Draught Regulator

PUCCI S.r.l. COMPONENTS AND ACCESSORIES FOR GAS BOILERS 0051 CPD 0080

Flues and chimney systems

PUCCI S.r.l. COMPONENTS AND ACCESSORIES FOR GAS BOILERS 0051 CPD CPD 0081

Transcription:

TW-Pro Twin Wall Insulated Flue System EN1856-1 T600 N1 W V2 L50040 G50 / O40

Approvals TW-Pro Twin Wall Insulated Flue System - TW-Pro has been specifically designed with the installer in mind with a range of installer friendly components. - TW-Pro is quick and easy to install leaving you with a clean lined system to the highest standards. - The unique, robust jointing system ensures a positive fit on every joint that is secured with a locking band. - TW-Pro with its open ended construction, eradicates the problem of hotspots within the joints leaving a continuos full insulated chimney throughout. HETAS The official body of solid fuel domestic heating appliances, fuels and services Jointing System Outer Wall EN 1856-1 : 2003 NO. 0099-CDP-A71-037 Product designation Standard Number EN1856-1 Design & Specification Temperature Level Pressure Level (N,P or h) Condensate resistance (W: Wet or d: Dry) Corrosion Resistance (Durability) & Distance to combustible material (mm) T600 N1 W V2 L50040 G50 Working Temperature - 600 C. N1-40pa Fuels - Gas, Oil, Wood, Coal. Materials- Inner wall- Inox Stainless steel AISI 316L Outer wall- Inox Stainless steel AISI 304BA Painted (R.A.L. range) Both the inner and outer wall are 0.4mm thick. All components are fully welded and insulated with high density ceramic blanket. The absence of thermal bridges prevents the interior wall of the chimney from cooling down, thus acheiving a rapid stable draw and optimum appliance performance. It also prevents the exterior wall from overheating allowing for safe insulation. The Unique jointing system guarantees a leak proof seal between the components. TW-Pro comes with a 25 year manufacturers warranty Component Diameters Dia (mm) 80 100 125 150 175 200 250 300 350 Inner Dia 80 100 125 150 175 200 250 300 350 Outer Dia 130 150 175 200 225 250 300 350 400 Adaptors Connection Clamp Ceramic Blanket Products (= Chosen Diameter) Adaptor To SW (Connecting pipe) Part No. 2-DDD-001 Increasing Adaptor To SW (Connecting pipe) Part No. 2-DDD-002 Increaser TW-Pro to TW-Pro Provides an increase in diameter by one from TW-Pro to TW-Pro Part No. 2-DDD-004 Flat Adaptor Part No. 2-DDD-005 100Ø 130Ø 150Ø 180Ø 200Ø Damper Section The Flue Damper helps regulate draught withing the chimney Part No. 2-DDD-006 80Ø 100Ø 130Ø 150Ø 180Ø 200Ø 250Ø Inner Wall

Draught Stabiliser Part No. 15-DDD-007 Straight Lengths 1000mm Pipe Length A 1000mm fixed straight length Part No. 2-DDD-010 500mm Pipe Length A 500mm fixed straight length Part No. 2-DDD-011 250mm Pipe Length A 250mm fixed straight length Part No. 2-DDD-012 1000mm Starter Length A 1000mm fixed straight length with adaptor Part No. 2-DDD-013 Adjustable Pipe Length (550-880) 550mm through to 880mm Part No. 2-DDD-014 125Ø 150Ø 175Ø 200Ø 250Ø Adjustable Pipe Length (350-500) 350mm through to 500mm Part No. 2-DDD-015 Adjustable Pipe Length (250-350) 250mm through to 350mm Part No. 2-DDD-016 500mm Testing Length A 500mm straight length which allows a probe to be inserted to test the gases in the flue Part No. 2-DDD-019 Elbows & Tees 90 Elbow Part No. 2-DDD-030 45 Elbow Part No. 2-DDD-031 30 Elbow Part No. 2-DDD-032 15 Elbow Part No. 2-DDD-033 135 Tee Part No. 2-DDD-034 90 Tee Part No. 2-DDD-035 Tee Cap Part No. 15-DDD-036 Tee Cap c/w Drain Part No. 15-DDD-037 90 Bend Inspection Part No. 2-DDD-042 Support Items Locking Bands Helps to secure two adjoining pipes. Part No. 15-DDD-050 (50-80mm) Used to secure the pipework to the wall Part No. 15-DDD-051 (80-130mm) Part No. 15-DDD-052 (130-210mm) Part No. 15-DDD-053 (130-210mm) Part No. 15-DDD-055 125Ø 150Ø

Support Items Structural Locking Bands Helps to secure two adjoining pipes. Part No. 15-DDD-054 Adjustable Base Support Load Bearing Wall Support Part No. 2-DDD-060 Console Plate Part No. 2-DDD-061 Chest Mounting Plate Part No. 2-DDD-062 Roof Support Part No. 15-DDD-067 Part No. 15-DDD-068 Guy Wire Bracket Part No. 15-DDD-069 Firestops Firestop Plate Part No. 2-DDD-070 Ventilated Firestop Plate Part No. 2-DDD-073 Firestop Cover Plate WHITE Part No. 15-DDD-075 Firestop Cover Plate BLACK Part No. 55-DDD-075 Terminals Storm Collar Part No. 15-DDD-082 Rain Cap Part No. 15-DDD-090 Anti-wind Cowl Part No. 15-DDD-091 Gas Cowl Part No. 15-DDD-092 Cone Top Cowl Part No. 2-DDD-093 Rotating Cowl Part No. 15-DDD-094 H-Cowl Part No. 15-DDD-103 125Ø 150Ø Insulation Cover Plate Part No. 15-DDD-104 Finnishing Plates Finishing Plate 0-30 Part No. 15-DDD-096 Finishing Plate 30-45 Part No. 15-DDD-097 Round Finishing Plate 90 Part No. 15-DDD-106 Round Finishing Plate 45 Part No. 15-DDD-107

Accessories Damper Section Part No. 2-DDD-006 Draught Stabliser Part No. 15-DDD-007 Wall Sleeve Part No. 15-DDD-098 Wall Sleeve 45 Adjustable Part No. 15-DDD-100 Gasket Part No. 15-DDD-102 Typical Internal Installation Typical External Installation Choice of Terminal Storm Collar Flashing (res1) Choice of Terminal Roof Support 2 x Ventilated Firestop Plates Locking Band in between each joint Wall Sleeve 2 x Ventilated Firestop Plates Adjustable Length 135 Tee 45 Bend Tee Cap Adaptor to SW Adaptor to SW Adj Base Support Mi-Flues has adopted a policy of continuous product review, and in the interests of development and improvement the Company reserves the right to vary the appearance and performance of any of its products without prior notice.