GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

Similar documents
GETTING STARTED GUIDE NI Channel, 0 ma to 20 ma, 16-Bit Analog Output Module. This document explains how to connect to the NI 9265.

GETTING STARTED GUIDE NI DI, 30 V, Sourcing, 7 μs

GETTING STARTED GUIDE NI TC, ±78 mv, 24 Bit, 75 S/s Aggregate

GETTING STARTED GUIDE NI DIO, 5 V/TTL, Bidirectional, 7 μs

GETTING STARTED GUIDE NI AI, ±29.4 mv/v, 24 Bit, 10 ks/s/ch Simultaneous, 350 Ω Quarter-Bridge Completion

GETTING STARTED GUIDE NI AI/8 AO/4 DIO, 0 V to 5 V, 12 Bit, 20 ks/s Aggregate

GETTING STARTED GUIDE. NI 9212 and TB TC, ±78 mv, 24 Bit, 95 S/s/ch Simultaneous, Isothermal Terminal Block

ni.com/manuals For specifications, refer to the NI USB-TC01 Device Specifications document available at ni.com/manuals.

GETTING STARTED GUIDE NI NI-XNET Hardware Selectable Interface. Français Deutsch 日本語한국어简体中文. ni.com/manuals

Certificate of Compliance

NGC-40-IO Control and monitoring modules for use with the Raychem NGC-40 system Installation Instructions

Gas cylinder scale Model GCS-1

Certificate of Compliance

KM300 Carbon Monoxide Detection System Installation Manual

Vanguard. Toxic & combustible gas detector

TM-3100 Series Room Temperature Sensor

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

Light Level Detector, Surface Mount 5754PE. Installation Instructions

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

Safe Operation Manual. Honeywell IQ Force Gas Detector

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

Snifter ATEX22 VERSION. User Manual. Distributor

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

Quick Start Guide For the

HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Annubar Flowmeter Series

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Environmental Monitoring SmartSlot Card

itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter

L1L2L3. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

EtherCAT Box Modules (EPxxxx-xxxx)

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Fisher LCP100 Local Control Panel

safety & regulatory information

3500/61E & 3500/67E Temperature Monitor

Operating Instructions Edition 02/2007

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

C-Bus Four Channel General Input Unit Installation Instructions

CONTROL BE MADE CHANGES MAY NOT. Page 1

Certificate of Compliance

Cisco TelePresence MCU 4200 Series safety and compliance information

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

14300 MAINS SEPARATOR ALARM MANUAL

Isolated Thermocouple Module

Operation and Maintenance Manual

Dry Bath Heating Systems

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL

INSTRUCTION & SERVICE MANUAL

Refrigerated Incubator Model and Operating Instructions

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

SEC Signature Process Gas Analyzer

S5000 Gas Monitor. GMS5000.com

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

Dräger PIR 3000 Detection of flammable gases and vapours

Operating Instructions

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

Owner s Manual. PIR-1 IR Learner

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

UL HAZARDOUS LOCATIONS SERVICES

INSTALLATION AND OPERATING INSTRUCTIONS R-3F2-LXX

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

180 Degree Ceiling Mounted Occupancy Sensors

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

Annex to: IECEx ULD U Issue. No. 2 Manufacturer: Detector Electronics Corporation Electrical apparatus: Eagle Quantum Premier system Modules

MBCE-110/230UV Flame Sensor Module

AO Annunciator Module

64 Max IR Thermometer

Reacti-Therm I and III Heating Modules

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

Inductive slot sensor

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Model SWH-3000 Proximity Multi-Frequency 125KHz & 13.56MHz (Fixed) Reader Installation Guide. Version A0 Part Number UM-102 September 2005

LC2200 Level Controller Installation and Maintenance Instructions

MBCE-110/230FR Flame Sensor Module

EOTec 2C32 Installation Guide

FEC403EN Installation Manual

Supplement. Title: 365 Users Supplement Issue: 8 Part Number: Issue Date: 7/16 Print Date: August 2010 Page Count: 6 Revision/Date:

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

Operating Manual MS220DA

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Instruction Manual. CAT 100 & CAT 200 Continuous Analyzer Transmitter Addendum for Hazardous Area Applications. 3 rd Edition 05/2007

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Intrinsically Safe Transmitters, Option Code 2n

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Datasheet - MZM 100 ST2-1P2PWREM-A

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

Transcription:

GETTING STARTED GUIDE NI 9217 4 RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

This document explains how to connect to the NI 9217. Note Before you begin, complete the software and hardware installation procedures in your chassis documentation. Note The guidelines in this document are specific to the NI 9217. The other components in the system might not meet the same safety ratings. Refer to the documentation for each component in the system to determine the safety and EMC ratings for the entire system. Safety Guidelines Operate the NI 9217 only as described in this document. Caution Do not operate the NI 9217 in a manner not specified in this document. Product misuse can result in a hazard. You can compromise the safety protection built into the product if the product is damaged in any way. If the product is damaged, return it to NI for repair. 2 ni.com NI 9217 Getting Started Guide

Hazardous Voltage This icon denotes a warning advising you to take precautions to avoid electrical shock. Safety Voltages Connect only voltages that are within the following limits. Maximum Voltage Connect only voltages that are within the following limits. 1 All terminals-to-com Isolation Voltages Channel-to-channel ±30 V None 1 The maximum voltage that can be applied between any channel or Vsup terminal and a COM terminal without damaging the module or other devices. NI 9217 Getting Started Guide National Instruments 3

Channel-to-earth ground Continuous up to 2,000 m up to 5,000 m Withstand up to 2,000 m up to 5,000 m 250 Vrms, Measurement Category II 60 VDC, Measurement Category I 2,300 Vrms, verified by a 5 s dielectric withstand test 1,000 Vrms, verified by a 5 s dielectric withstand test Measurement Category II is for measurements performed on circuits directly connected to the electrical distribution system. This category refers to local-level electrical distribution, such as that provided by a standard wall outlet, for example, 115 V for U.S. or 230 V for Europe. Note Measurement Categories CAT I and CAT O are equivalent. These test and measurement circuits are not intended for direct connection to the MAINS building 4 ni.com NI 9217 Getting Started Guide

installations of Measurement Categories CAT II, CAT III, or CAT IV. Caution Do not connect the NI 9217 to signals or use for measurements within Measurement Categories III or IV. Safety Guidelines for Hazardous Voltages If hazardous voltages are connected to the device, take the following precautions. A hazardous voltage is a voltage greater than 42.4 Vpk voltage or 60 VDC to earth ground. Caution Ensure that hazardous voltage wiring is performed only by qualified personnel adhering to local electrical standards. Caution Do not mix hazardous voltage circuits and human-accessible circuits on the same module. Caution Ensure that devices and circuits connected to the module are properly insulated from human contact. Caution When module terminals are hazardous voltage LIVE (>42.4 Vpk/60 VDC), you must ensure that devices and circuits connected to the module are NI 9217 Getting Started Guide National Instruments 5

properly insulated from human contact. You must use the NI 9939 connector backshell kit to ensure that the terminals are not accessible. Safety Guidelines for Hazardous Locations The NI 9217 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous locations; Class I, Zone 2, AEx na IIC T4 and Ex na IIC T4 hazardous locations; and nonhazardous locations only. Follow these guidelines if you are installing the NI 9217 in a potentially explosive environment. Not following these guidelines may result in serious injury or death. Caution Do not disconnect I/O-side wires or connectors unless power has been switched off or the area is known to be nonhazardous. Caution Do not remove modules unless power has been switched off or the area is known to be nonhazardous. Caution Substitution of components may impair suitability for Class I, Division 2. 6 ni.com NI 9217 Getting Started Guide

Capacitance Caution For Division 2 and Zone 2 applications, install the system in an enclosure rated to at least IP54 as defined by IEC/EN 60079-15. Caution For Division 2 and Zone 2 applications, connected signals must be within the following limits. 0.2 µf maximum Special Conditions for Hazardous Locations Use in Europe and Internationally The NI 9217 has been evaluated as Ex na IIC T4 Gc equipment under DEMKO Certificate No. 03 ATEX 0324020X and is IECEx UL 14.0089X certified. Each NI 9217 is marked II 3G and is suitable for use in Zone 2 hazardous locations, in ambient temperatures of -40 C Ta 70 C. If you are using the NI 9217 in Gas Group IIC hazardous locations, you must use the device in an NI chassis that has been evaluated as Ex nc IIC T4, Ex IIC T4, Ex na IIC T4, or Ex nl IIC T4 equipment. Caution You must make sure that transient disturbances do not exceed 140% of the rated voltage. NI 9217 Getting Started Guide National Instruments 7

Caution The system shall only be used in an area of not more than Pollution Degree 2, as defined in IEC 60664-1. Caution The system shall be mounted in an ATEX/IECEx-certified enclosure with a minimum ingress protection rating of at least IP54 as defined in IEC/EN 60079-15. Caution The enclosure must have a door or cover accessible only by the use of a tool. Electromagnetic Compatibility Guidelines This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic environment. This product is intended for use in industrial locations. However, harmful interference may occur in some installations, when the product is connected to a peripheral device or test object, or if the 8 ni.com NI 9217 Getting Started Guide

product is used in residential or commercial areas. To minimize interference with radio and television reception and prevent unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation. Furthermore, any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules. Caution To ensure the specified EMC performance, operate this product only with shielded cables and accessories. Special Conditions for Marine Applications Some products are Lloyd s Register (LR) Type Approved for marine (shipboard) applications. To verify Lloyd s Register certification for a product, visit ni.com/certification and search for the LR certificate, or look for the Lloyd s Register mark on the product. Caution In order to meet the EMC requirements for marine applications, install the product in a shielded NI 9217 Getting Started Guide National Instruments 9

enclosure with shielded and/or filtered power and input/output ports. In addition, take precautions when designing, selecting, and installing measurement probes and cables to ensure that the desired EMC performance is attained. Preparing the Environment Ensure that the environment in which you are using the NI 9217 meets the following specifications. Operating temperature -40 C to 70 C (IEC 60068-2-1, IEC 60068-2-2) Operating humidity (IEC 60068-2-78) Pollution Degree 2 Maximum altitude Indoor use only. 10% RH to 90% RH, noncondensing 5,000 m Note Refer to the device datasheet on ni.com/manuals for complete specifications. 10 ni.com NI 9217 Getting Started Guide

NI 9217 Pinout EX0 RTD0+ RTD0 COM EX1 RTD1+ RTD1 COM EX2 RTD2+ RTD2 COM EX3 RTD3+ RTD3 COM 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 NI 9217 Getting Started Guide National Instruments 11

Table 1. Signal Descriptions Signal COM EX RTD+ RTD- Description Common reference connection to isolated ground Excitation source connection Positive resistance temperature detector connection Negative resistance temperature detector connection Connecting 3-Wire and 4-Wire RTDs You can connect any combination of 3-wire or 4-wire RTDs to the NI 9217. Each NI 9217 channel contains circuitry that automatically detects the type of RTD connected to the channel. The NI 9217 scans all four input channels and automatically configures each channel for the appropriate mode. In 4-wire mode, the EX terminal is a 1 ma current source. In 3-wire mode, the RTD+ terminal is a 1 ma current source. The NI 9217 compensates for the error that lead resistance causes in 3-wire mode. 12 ni.com NI 9217 Getting Started Guide

If you are using a 4-wire RTD, connect EX to the positive lead of the RTD. If you are using a 3-wire RTD, do not connect the RTD to the EX terminal. Figure 1. Connecting an RTD to the NI 9217 4-Wire EX RTD+ RTD RTD COM NI 9217 For the best measurement results when using the NI 9217 with a 3-wire RTD, use equal-length wires between the RTD+ terminal and the RTD and between the COM terminal and the RTD. Also, keep the lead resistance within 5% of the nominal RTD value. The NI 9217 accuracy specifications account for this lead error. Note The accessory used with the NI 9217 may introduce additional lead resistance mismatch error in NI 9217 Getting Started Guide National Instruments 13

3-wire mode. Refer to the device datasheet on ni.com/ manuals for information about errors due to lead resistance mismatch. NI 9217 Connection Guidelines Make sure that devices you connect to the NI 9217 are compatible with the module specifications. You must use 2-wire ferrules to create a secure connection when connecting more than one wire to a single terminal on the NI 9217. Wiring for High-Vibration Applications If your application is subject to high vibration, NI recommends that you follow these guidelines to protect connections to the NI 9217: Use ferrules to terminate wires to the detachable connector. Use the NI 9939 backshell kit. 14 ni.com NI 9217 Getting Started Guide

Where to Go Next CompactRIO NI CompactDAQ NI 9217 Datasheet NI-RIO Help LabVIEW FPGA Help NI 9217 Datasheet NI-DAQmx Help LabVIEW Help RELATED INFORMATION C Series Documentation & Resources ni.com/info cseriesdoc Services ni.com/services Located at ni.com/manuals Installs with the software NI 9217 Getting Started Guide National Instruments 15

Worldwide Support and Services The NI website is your complete resource for technical support. At ni.com/support, you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers. Visit ni.com/services for NI Factory Installation Services, repairs, extended warranty, and other services. Visit ni.com/register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updates from NI. A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European Communities using the manufacturer s declaration of conformity. This system affords the user protection for electromagnetic compatibility (EMC) and product safety. You can obtain the DoC for your product by visiting ni.com/certification. If your product supports calibration, you can obtain the calibration certificate for your product at ni.com/calibration. 16 ni.com NI 9217 Getting Started Guide

NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. NI also has offices located around the world. For telephone support in the United States, create your service request at ni.com/support or dial 1 866 ASK MYNI (275 6964). For telephone support outside the United States, visit the Worldwide Offices section of ni.com/niglobal to access the branch office websites, which provide up-to-date contact information, support phone numbers, email addresses, and current events. NI 9217 Getting Started Guide National Instruments 17

Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/ export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. 2006 2016 National Instruments. All rights reserved. 374187F-01 Mar16