Control Panel User Guide (TO BE RETAINED BY THE USER)

Similar documents
Control Panel User Guide

Control Panel User Guide

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Control Panel Engineering and Commissioning Manual (TO BE RETAINED BY THE COMMISSIONING ENGINEER)

Fire detection and alarm system Operating instructions

Intelligent Security & Fire Ltd

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Document No Issue 4 user manual

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Control Panel Engineering and Commissioning Manual (TO BE RETAINED BY THE COMMISSIONING ENGINEER)

one Operating instructions SenTRI ONE panel-based Fire detection and alarm system

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

Logbook. Precept EN Fire Detection/Alarm Panel. & Precept EN Repeater

USER MANUAL & MAINTENANCE GUIDE OG OO

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

Noby-448 User Operating Manual & Log Book Page 1 of 12. Fire Control Panel. User Operating Manual & Log Book

Operating instructions Vigilon panel and Network node Fire detection and alarm system

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANEL. user manual and log book. approved document no. DFU Rev 1

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM

Conventional Fire System. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI User Manual

user manual Document No , Revision 03 November 2015

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Scimitar user manual & log book. Petersfield Business Park, Bedford Rd, Petersfield, Hampshire GU32 3QA Tel: Fax:

Control Panel Engineering and Commissioning Manual (TO BE RETAINED BY THE COMMISSIONING ENGINEER)

SECURIT 700L USER MANUAL

user manual and log book XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANEL

SYSTEM 5000 USER MANUAL

FIRE ALARM CONTROL PANEL FVC01-08

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

ZERIO PLUS EDA-Z5008, Z5020 & Z5100

ZSC100 Gas Detection and Alarm System Controller

Installation, Operating and Maintenance Manual

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

HS-5100, HS-5200, HS-5400 ANALOGUE ADDRESSABLE CONTROL PANELS. User Manual. Approved Document UI-ELAN-02 Revision 03

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM

HARDWIRED CONTROL PANELS

Fire Alarm Control Panel. System Maintenance and Log Book

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

ID2000. operating manual

U ser's Guide PC6010

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

ZP3 Operator & Maintenance Manual Version 1

KFP-CF Series Operation Manual

Control Panel Engineering and Commissioning Instructions

ZM2 OPERATING AND MAINTENANCE INSTRUCTIONS

ZP2 Series Operation Manual

M800, M800iD Plus, M1000 and M3000. User's Guide

SYSTEM 3400 ANALOGUE ADDRESSABLE FIRE DETECTION. (with Devices) Operating Manual Version 3.3X Issue 2 September 1996

Intelligent Security & Fire Ltd

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

2200 and 2200L ALARM CONTROL SYSTEMS

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL

FIRE BRIGADE RESPONSE GUIDE. LoopSense. Fire Alarm Control Panel (AS4428 & AS & 4) Operation & Onsite Programming MAN

USER MANUAL CEF AP28 CONTROL PANEL

Operator's Handbook. Release 3. Fire Alarm Control Panel, BS-310 / 320 / Operator Panel BS-330. System Program Version 3.8.0

SECURIT 703 USER MANUAL

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

CSP-204 CSP-208 CSP-104 CSP-108

PROFYRE C8 USER MANUAL, MAINTENANCE GUIDE & LOG BOOK FIRE ALARM CONTROL PANEL USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator.

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Section 9 System Operation

HARDWIRED CONTROL PANELS

Master User Guide. Premier 412/816/832. Issue 8

QA16 Addressable System

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

USER GUIDE HARDWIRED CONTROL PANELS

Racal-Guardall. Countess. User Instructions. Countess

SERIES 3000 INTELLIGENT FIRE ALARM CONTROL PANEL ENGINEERING PROGRAMING MANUAL TABLE OF CONTENTS.. 1 INTRODUCTION.. 3 SYSTEM POWER UP.

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

i on Compact Security System

Index. Premises Information 2 About This Log Book 3 Service and Maintenance Requirements 4 8. Fire Risk Assessments 9

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

USER GUIDE HARDWIRED CONTROL PANELS

TS2500. Intruder Alarm Control Panel. SYSTEM OPEN 17:30 01 Jan ENT ESC. Setting the System. Unsetting the System RE SET

Watchguard WGAP864 User Manual

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be

Surveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Section 8 System Operation

Advisor Advanced User Guide

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

NX-148 LCD CODE PAD TABLE OF CONTENTS

Product Data Sheet. Remote Terminals. Features:


TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

Challenger Series Users Manual

Warning: Mains voltages are present inside control unit. No user serviceable parts inside.

User Operation Manual

THANK YOU FOR VOTING TEXECOM THANK YOU FOR VOTING TEXECOM USER GUIDE. Security Control Panels 1 INS167

The EN54 Part 2, 4 and 13 Fire System

SIMPLICITY MICRO INSTRUCTION MANUAL ANALOGUE ADDRESSABLE FIRE ALARM PANEL INSTRUCTION MANUAL

Transcription:

Fire Detection & Alarm System Control Panel V3 (Suitable for Quadnet control panels from V2.00) Control Panel User Guide (TO BE RETAINED BY THE USER) 26-0585 Issue 7

Fike s policy is one of continual improvement and the right to change a specification at any time without notice is reserved. Whilst every care has been taken to ensure that the contents of this document are correct at time of publication, Fike shall be under no liability whatsoever in respect of such contents. Due to the complexity and inherent importance of a life risk type system, training on this equipment is essential and commissioning should only be carried out by competent persons. Fike cannot guarantee the operation of any equipment unless all documented instructions are complied with, without variation. E&OE. Fike equipment is protected by one or more of the following patent numbers: GB2426367, GB2370670, EP1158472, PT1035528T, GB2346758, EP0917121, GB2329056, EP0980056, GB2325018, GB2305284, EP1174835, EP0856828, GB2327752, GB2313690 2

Contents Introduction... 4 Purpose of the Guide... 4 Definitions... 4 Understanding the Equipment... 4 System Configuration... 5 What to do if... 5 User Responsibilities... 6 Introduction... 6 Routine Testing... 6 General Operation... 8 Control Panel Front... 8 Normal... 8 Fire Alarm Controls... 9 System Controls... 9 Access Levels and Codes... 9 Fire Alarm... 10 On Hearing the Alarm... 10 Accessing the Controls... 10 Silencing the Alarms... 10 Resetting the System... 10 Sounding the Alarms (evacuate)... 11 Silencing the Buzzer... 11 Exit Access Level Two... 11 Troubleshooting... 12 Advanced Operation... 13 Access Level 1 (Normal)... 13 Access Level 2A (User)... 13 Access Level 2B (Supervisor)... 14 Printer... 18 LED Indication... 19 Log Book... 21 Installation Details... 28 (Back Page) 3

Introduction Purpose of the Guide This guide is provided to enable the person responsible for the fire alarm system (see Definitions) to operate the system, undertake their responsibilities with regard to testing and maintenance of the system, and to record events and service/maintenance visits. This is a generic document and therefore refers to the system components in general terms only. The details of the installed system should be recorded in the space provided within this guide, and for further reference, the record drawings (if applicable) should be consulted. The responsible person, and any other staff who may be required to operate the system in an emergency, should read and understand the basic operating instructions before an emergency situation occurs. Definitions Responsible person: The person having control of the premises, whether as an occupier or otherwise, or any person delegated by the person having control of the premises to be responsible for the fire alarm system and the fire procedures. Competent Person: A person competent to perform a defined task: Normally a competent person will be an employee of the manufacturer, installer, or servicing contractor, or a member of the user s staff who has received suitable training from the manufacturer, supplier or installer. Understanding the Equipment What is Quadnet? Quadnet is the name of the range of fire alarm control panels that use the associated Sita 200 plus devices which together form the fire alarm system installed in the premises. It is the type of system, whereby up to four addressable device loops may be connected to each control panel, and up to 4 control panels may be networked together. Advantages of the Quadnet system are significantly reduced cabling costs, enhanced flexibility and flexible expansion capacity if required. What is Multipoint? This is the name of the automatic detector used in the Quadnet installation. The Multipoint is a unique device, which provides several modes of detection & sensitivity options within a single device, enabling it to be easily configured for the application. One detector can function as a smoke detector or heat detector (or both), and with various levels of sensitivity to suit the environment. The Multipoint detector may also incorporate an integral sounder and strobe for general alarm annunciation or local warning as required and an automatic isolator to maintain maximum cable integrity in the event of a cable fault. 4

System Configuration The detectors and call points are arranged in zones to enable the location of a fire alarm to be identified. The number of zones depends on the size and the layout of the premises, and is limited to 128 zones per control panel (there may be more than one). There should be a chart or drawing provided with the system indicating the area and layout of the zones ensure that you are familiar with the zone layout so that appropriate action can be taken in the event of a fire alarm. The control panel display may also give you a zone number, a device description, a device number and a device type; indicating the exact location of the device which has operated. The system may be interfaced with the building services, e.g., the air conditioning may be shut down when the alarm sounds. Make sure that you know what happens when the fire alarm operates as this can affect routine system testing. The system is powered from the mains supply and incorporates a standby battery which automatically maintains the system in operation for a time of at least 48 hours in the event of a mains supply failure. What to do if... The fire alarm sounds; CARRY OUT THE PRESCRIBED FIRE DRILL When it is safe to do so silence the alarms and reset the system, having first established the cause of the alarm (refer to Operation). The panel buzzer sounds; If the panel buzzer sounds without the alarm sounders operating it is likely to be a fault or other abnormal condition. Make a note of all illuminated LEDs and displayed messages, record the time that the condition occurred (if known), and other events within the building, eg., power failure, contractors working, etc. (refer to Troubleshooting). Call the service company with as much information as possible. 5

User Responsibilities Introduction The responsible person is required under BS5839 to undertake certain tasks with respect to the testing and maintenance of the fire alarm system. The responsible person should also ensure that written procedures are in place for the actions to be taken by the occupants in a fire condition, and that staff required to operate the system have received adequate training. In a small building the fire procedures can be quite simple, but when larger premises are involved the fire procedures can become more complex and may involve the appointment of fire wardens, reporting procedures, various assembly points, etc. The responsible person is also required to liaise with the building maintenance personnel to ensure that their work does not impair or otherwise affect the operation of the fire alarm system, and to ensure that a clear space is maintained in the vicinity of detectors, and call points remain unobstructed and conspicuous. Routine Testing The responsible person should also ensure that the following routine testing is carried out. If there is a link to a remote monitoring centre it will be necessary to advise the centre prior to a test, or use the control panel facilities to isolate the link. On larger systems it may be necessary to isolate building services interfaces to avoid disruption to the occupants. In any case the panel should provide audible and visual indication that parts of the system are disabled. Daily Check that the panel indicates normal operation and that any fault is recorded. Also check that the recorded faults have been dealt with. Weekly At least one detector or call point should be operated to test the ability of the control equipment to receive a signal and sound the alarm. In practice it is far easier for the user to activate a manual call point, rather than a detector which requires special equipment. A different device should be tested each time if possible, such that each zone on the system is tested at least once in a 13 week period. The results should be recorded in the log book. Quarterly The responsible person should ensure that every three months the following check is carried out by a competent person In other words the system should be checked by a fire alarm service organisation. This may be the system installer or an approved maintenance company, and is normally arranged via a maintenance agreement which specifies the number of visits and the level of service. The agreement should also cover non-maintenance visits, eg. call outs to attend faults, etc. The standard specifies a number of maintenance tasks which include a visual inspection of the installation to ensure that there are no alterations or obstructions which could affect the operation of the system, and functional checks to confirm the operation of the system. 6

Any defects should be recorded in the log book and reported to the responsible person. A certificate of testing should also be completed and given to the responsible person. Annual The requirements of the annual test are similar to the quarterly test except that each device on the system should be tested. Different service organisations may undertake device testing on the same visit, ie. One major service and three minor service visits per year, or they may test a percentage of the devices on each visit so that they are all tested within the 12 month period. Action by the user after a fire Advise the servicing company and arrange for the system to be tested by them. A certificate of testing should be issued to confirm the system operation following the inspection and any remedial work that is necessary. Action by the user after any false alarm The user can assist the servicing company in the identification of false alarms by observing the following: Always make a note of all illuminated indicators and messages displayed at the control panel. Try and identify the activated device, ie. Do not reset the system until the area of the incident has been inspected. Record any other incidents occurring at the same time which could affect the system, eg. power supply failure, building works, etc. The service organisation will be more likely to trace the false alarm if the above information is available. Action by the user following a fault When a fault is reported by the control panel, the user should note all illuminated LEDs and messages displayed, and the circumstances at the time the fault occurred, and report to the servicing company. The service company will be able to advise if the system is still able to respond to a fire alarm or whether extra vigilance should be observed until the fault is rectified. Faults should not be left unreported. 7

> Quadnet Control Panel User Guide General Operation Control Panel Front fire fault disabled test power V3.00 Panel 01: PANEL 01 23/05/11 23:01 NORM General Indication LEDs Control Panel Information Window QUADNET MULTILOOP FIRE ALARM SYSTEM. TURN KEY OR ENTER CODE FOR CONTROLS Active Information Window Prompt Window Network Information Window zones 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 Zonal Indication LEDs fire alarm controls turn key to enable controls silence reset sound silence alarms system alarms buzzer enable controls Fire Alarm Controls system indication system fault power fault earth fault loop sounder fire output zone fault output day routine service tech alarm confirmation delay alarms buzzer silenced system controls < /\ ENTER > 1 2 3 0_0 ABC DEF 4 5 6 GHI JKL MNO 7 8 9 PQRS T UV WXYZ ESC * 0 # _ System Indication LEDs System Controls Normal: Controls Enabled LED off At Access Level 1 (Normal), the main Fire Alarm Controls are disabled and the Controls Enabled LED is switched off. 8

< Quadnet Control Panel User Guide Fire Alarm Controls The main Fire Alarm Controls may be enabled by turning the key switch to the controls enabled position, or by entering a valid Access code. fire alarm controls turn key to enable controls enable controls silence alarms reset system sound alarms silence buzzer System Controls User 1. Delay Override 2. Test Display < < enter > Supervisor 1. Delay On/Off 2. Test Display 3. View Logs 4. Disable/Enable 5. Set Time & Date 6. Test Modes 7. Day/Night Mode 8. Find Device * 1 o_o 4 GHI 7 PQRS ESC 2 ABC 5 JKL 8 TUV 0 3 DEF 6 MNO 9 WXYZ # A context-driven highlighted-selection menu system is used to navigate the menu system, automatically prompting you with the relevant options for your Access Level and system status. Menu examples shown below are for the V3 control panel. Menus in some earlier panel versions may differ. The menus may be navigated in one of two ways as required: 1. Use the UP / DOWN keys to move the highlighted selection and press ENTER to select the chosen one. 2. Enter the desired option number and press ENTER to select it. Press the Esc key to exit to the previous menu. Access Levels and Codes The menu system is divided into four access levels in order to restrict access to those who require it. For simple indication the status of the Controls Enabled light will show the level selected as follows; Access Level Description Shift LED Key Operation Default Code 1 NORM Normal OFF YES N/A 2A USER User ON YES 8737 2B SUPR Supervisor SLOW FLASH NO 7877 The fourth level (Engineer) is not shown above. Access to the menu system requires either the operation of the enable controls key for access to Access Level 2A (User), or the correct entry of the relevant code for access to all other levels, in order to protect against unauthorised access to the system. 9

The codes may be changed using the Quadnet OSP software. A valid access level code must be entered in order access any of the menus. Fire Alarm When the panel enters the fire state, the alarms will sound, the fire LEDs will illuminate, the panel buzzer will pulse quickly and the display will show the location and type of alarm. On Hearing the Alarm The responsible person should have already prepared written procedures for the action to be taken in the event of a fire alarm. When the alarm sounds these procedures should be implemented. Accessing the Controls The user controls are accessed from Access Level 2A (User), or Access Level 2B (Supervisor) which is reached as follows: 1. Turn the key, Or: Enter your Access Level 2 (User) or Access Level 2B (Supervisor) code, ie, # # # # The CONTROLS ENABLED light will light up continuously, and USER is displayed in the top right hand corner. The panel buzzer will be heard on each key press, and when successfully entered the CONTROLS ENABLED light will light up continuously, and USER or SUPR is displayed in the top right hand corner. You are now in Access Level 2A (User) or Access Level 2B (Supervisor) and may proceed to silence and reset the system. Silencing the Alarms When the fire procedures have been carried out and it is safe to silence the alarm, proceed as follows. 1. Press SILENCE ALARMS The alarm sounders should silence, but the panel buzzer and the fire indication lights should remain. Resetting the System Before attempting to reset the system the cause of the alarm should be established. 1. Press RESET SYSTEM The panel buzzer and the fire indication lights should switch off. However, if any alarm condition still exists, eg., a manual call point requires resetting, then the panel will revert to the fire state until the cause for the alarm is removed. Note: if the panel does not reset or a fault condition is displayed, call your maintenance engineer immediately. 10

Sounding the Alarms To sound the alarms at any time after they have been silenced, proceed as follows: 1. Press SOUND ALARMS The alarm sounders will activate. The panel buzzer and the fire indication lights will also switch on. Silencing the Buzzer To silence the panel buzzer press the [SILENCE BUZZER] button at access level two as above. 1. Press SILENCE BUZZER The panel buzzer will be silenced. Exiting Access Level 2A (User) or Access Level 2B (Supervisor) In order to prevent unauthorised access to the system, return to Access Level 1 (Normal). However, if left untouched the display will time out after a short while and return automatically to Access Level 1 (Normal). 1. Turn the key OFF if it is turned on. Or; Press ESC until the system shows NORM in the top right hand corner. The CONTROLS ENABLED light will switch off and the controls are disabled. NORM is displayed in the top right hand corner. 11

Troubleshooting Problem Possible Cause Remedial Action Unable to silence alarms Panel not in Access Level 2A (User) or Access Level 2B (Supervisor) Enter Access Level 2A (User) or Access Level 2B (Supervisor) - see section on operation Unable to reset system Alarms not silenced Silence alarms before attempting to reset Panel buzzer sounding, FAULT LED lit Panel buzzer sounding, POWER FAULT LED flashing, Mains supply failed displayed. Panel buzzer sounding, SYSTEM FAULT LED lit Any other fault or abnormal behaviour Panel not in Access Level 2 (User) or Access Level 2B (Supervisor) Alarm condition still present Fault or abnormal condition Mains supply failure Control panel fault Various the system Enter Access Level 2 (User) or Access Level 2B (Supervisor) - see section on operation Remove cause of alarm, eg. reset call point element with key Note all illuminated LEDs and displayed messages. Call engineer Wait until mains supply is restored if panel does not revert to normal operation call engineer. Call engineer immediately Note all illuminated LEDs and displayed messages. Call engineer 12

Advanced Operation Menu examples shown below are for the V3 control panel. Menus in some earlier panel versions may differ. Access Level 1 (Normal): Controls Enabled LED off At Access Level 1 (Normal), the main Fire Alarm Controls are disabled and the Controls Enabled LED is switched off. A valid access level code must be entered or the key switch must be used in order access any of the menus. Access Level 2A (User): Controls Enabled LED on At Access Level 2A (User), the main Fire Alarm Controls are enabled, and the following System Controls are accessible: 1. Delay Override Delay Override The Delay Override function overrides any programmed delays. 2. Test Display Test Display The Test Display function causes the panel LEDs to illuminate, and the LCD screen to blacken, and the panel buzzer to sound in order to verify their correct operation. Press the Esc key to exit to the previous menu. 13

Access Level 2B (Supervisor): Controls Enabled LED flashing slowly At Access Level 2B (Supervisor), the main Fire Alarm Controls are enabled, and the following System Controls are accessible: 1. Delay On / Off 2. Test Display 3. View Logs 1. Current Warnings 2. Current Faults 3. Current Disablements 4. Current Tests 5. Event Logs 4. Disable / Enable 1. Detection Zone 2. Device 3. Sounders 4. Fire Outputs 5. Fault Outputs 6. Default to all enabled 5. Set Time & Date 6. Test Modes 1. Silent Test 2. Local Audible Test 1. All Events 2. By Event Type 1. User Action 3. By Device Type 4. By Loop No - Device No 5. By Date 2. Panel Event 3. Fire Event 4. Fault Event 1. Multipoint with sounder 2. Multipoint 3. Manual Call Point with sounder 4. Manual Call Point 5. Sounders & Strobes 6. Input / Output Modules 7. Conventional Zone Module 7. Day / Night Mode 8. Find Device 3. System Test 1. Override into Day Mode 2. Override into Night Mode 3. End all Overrides 4. View Day / Night settings 6. Network Events 1. All Events 2. By Event Type 3. By Panel 4. By Date 1. Delay On/Off The Delay On/Off function allows pre-configured time delays to be over-ridden or re-instated manually as required, ie, if sounder operation within a chosen area is programmed to operate after a time delay, then this delay may be removed or replaced using this function. 2. Test Display The Test Display function causes the panel LEDs to illuminate, the LCD screen to blacken and the panel buzzer to sound in order to verify their correct operation. 14

3. View Logs 1. Current Warnings The Active Warnings Log will display any current warnings. These are displayed in text format and may be scrolled through by pressing the UP and DOWN keys. 3. View Logs 2. Current faults The Active Faults Log will display any current faults. These are displayed in text format and may be scrolled through by pressing the UP and DOWN keys. 3. View Logs 3. Current Disablements The Active Disablement Log will display any current disablements. These are displayed in text format and may be scrolled through by pressing the UP and DOWN keys. 3. View Logs 4. Current Tests The Active Tests Log will display any current test modes. These are displayed in text format and may be scrolled through by pressing the UP and DOWN keys. 3. View Logs 5. Event Logs The Event Log stores 1000 local fire / fault events and 1000 network events which may be displayed in entirety, or displayed by category. These are displayed in text format and may be scrolled through by pressing the UP and DOWN keys. 4. Disable / Enable 1. Detection Zone This function allows the disablement or enablement of a detection-zone. Thus, all the input devices (Manual Call Points, detectors and inputs) within that detection-zone will be disabled. The control panel will indicate that disablements are present, a disablement event will be recorded in the log, the device LED will still operate when activated and an event will be recorded in the log, but no programmed actions will occur. The sounder within the device will still operate if triggered from elsewhere on the system. 4. Disable / Enable 2. Device This function allows the disablement or enablement of an individual device. The control panel will indicate that disablements are present, a disablement event will be recorded to log, the device LED will still operate when activated and an event will be recorded to log, but in the programmed actions will occur. The sounder within the device will still operate if triggered from elsewhere on the system. 4. Disable / Enable 3. Sounders This function allows the global disablement or enablement of all the sounders on the system. The control panel will indicate that disablements are present and a disablement event will be recorded in the log. 15

4. Disable / Enable 4. Fire Outputs This function allows the global disablement or enablement of all fire outputs on the system. The control panel will indicate that disablements are present and a disablement event will be recorded in the log. 4. Disable / Enable 5. Fault Outputs This function allows the global disablement or enablement of all fault outputs on the system. The control panel will indicate that disablements are present and a disablement event will be recorded in the log. 4. Disable / Enable 6. Default to all enabled This function enables any device / action that may have been disabled, and all programmed actions are reinstated. The control panel event log will indicate that all actions have been reinstated. 5. Set Time and Date This allows the time and date to be adjusted. These settings will need to be re-entered after the complete removal of power, as the system will simply resume from the point that power was removed. 6. Test Modes 1. Silent Test The Silent Test function allows the selection of one or more detection-zones to operate in a silent one-man walk test mode. On triggering a device the device LED operates and the event is recorded into the event log as a test activation, but the sounder does not sound and the control panel does not show an alarm. After approximately 5 seconds the system will reset the device, and another may be tested. The control panel event log will indicate that a test mode has been selected. 6. Test Modes 2. Local Audible Test The Local Audible Test function allows the selection of one or more detection-zones to operate in a one-man walk test mode with local sound. On triggering a device the device LED operates, the sounder within that device operates and the event is recorded into the event log as a test activation, but the control panel does not show an alarm. After approximately 5 seconds the system will reset the device, and another may be tested. The control panel event log will indicate that a test mode has been selected. 6. Test Modes 3. System Test The System Test function allows the entire system to operate in a simple one-man walk test mode. On triggering a device the device LED operates and the event is recorded into the event log, all the assigned sounders operate for 10 seconds and the control panel indicates an alarm. After approximately 10 second the system will reset the device, and another may be tested. The control panel event log will indicate that a test mode has been selected. Please note, with the system test mode, only the sounders assigned to operate from that device will sound, and any delays will still be present. i.e., if a delay of 2 minutes is present, the system will have been reset before the sounders activate. 16

7. Day / Night Mode 1. Override into Day Mode This function allows the user to override any pre-programmed Day / Night timing information and force the system into the less sensitive Day Mode. This will cause the panel buzzer to sound and a disablement to be written to log. 7. Day / Night Mode 2. Override into Night Mode This function allows the user to override any pre-programmed Day / Night timing information and force the system into the more sensitive Night Mode. This will cause the panel buzzer to sound and a disablement to be written to log. 7. Day Night Mode 3. End all Overrides This function ends any override on the Day / Night Mode, and all programmed actions are reinstated. The control panel event log will indicate that all actions have been reinstated 7. Day Night Mode 4. View Day / Night Setting This function allows the user to view the start and finish times for each day. 8. Find Device This function allows the user to switch on the LED and sounder (if they are present) at any device on the loop in order to aid in locating its position. It cannot be used to turn on the LED of I/O Modules, since this would also turn on the output which would not usually be desirable. Up, Down and Esc options allow the adjacent devices to be located, and the test to be ended. 17

Printer Paper out Quadnet Control Panels can have an optional printer fitted if required. This must be specified when ordering a panel and cannot be fitted by the end user or installer as an after market addition. If the printer is fitted it will print out local events as they occur. The local events which get printed will be fires and/or faults and/or panel events depending on how the engineer has programmed the panel during commissioning. The printer will automatically detect when the printer paper has run out. The Status indicator LED will flash repeatedly. Fitting a new roll of paper The paper used in the printer is FST Part No 507-0016. No other paper should be used. The printer paper can be accessed by lifting the front cover on the printer. Use the paper feed button (located on the right hand side opposite the Status indicator LED) to feed through the last few centimetres of paper. Fit a new paper roll onto the carrier. The printer incorporates an automatic paper feed facility. With a new paper roll mounted on the carrier and with a clean straight edge to the paper, present the paper to the entry point behind the rubber roller. The paper will be sensed by the mechanism and automatically feed through into a position ready for printing. Use the paper feed button to feed more paper through if required. Specification: Printing system Thermal line head Max characters per line 48 Character matrix (dots) 24x16, 24x12 or 24x8 Character size 3x2, 3x1.5 or 3x1mm (Approx. 13, 17 or 25cpi) Dot pitch horizontal 0.125mm (Approx. 200dpi) Dot pitch vertical 0.125mm Text line composition (dots) 24x384 Printing width 48mm Paper width 58 mm (+0 / -1) 18

LED Indication The operation of the LED indications on the front of the control panel is described below. Description Colour State Reason 1. FIRE Red Continuous The control panel is in the fire state. Other indicators will show the origin 2. FAULT Yellow Continuous The control panel is in the fault state. Other indicators will show the origin 3. DISABLED Yellow Continuous This indicates that a disablement action is in place. Enable all devices / actions to clear. 4. TEST Yellow Continuous This indicates that a test routine is in place. End all tests to clear. 5. POWER Green Continuous This indicates that power is being supplied to the control panel from either the 230V AC mains supply, or the standby batteries. 6. ZONE 1-128 Red Flashing A Manual Call Point in the zone indicated is in the alarm state and sending an alarm signal to the panel. A Detector in the zone indicated is in the alarm state and sending an alarm signal to the panel. 7. SYSTEM FAULT Yellow Flashing The system Fault LED indicates the presence of a processor or a checksum error. Power the system down to clear, reprogram all settings and test the system. 8. POWER FAULT Yellow Flashing Continuous The mains supply has failed (check the fuse and the 230V AC supply on the PCB AC terminals). A battery supply / charger fault has been detected (check the fuse and the battery voltages). 9. EARTH FAULT Yellow Flashing An earth fault has been detected where a path exists from the circuit wiring to earth. Remove circuits one at a time to discover which one, and then rectify. An earth fault may also be reported while a PC is connected to the panel for diagnostics or programming. In this case, the earth fault should clear when the PC is disconnected. 10. LOOP Yellow Flashing Continuous 11. SOUNDER Yellow Flashing Continuous 12. FIRE OUTPUT Yellow Flashing Continuous A fault condition is present on one or more addressable device loops, or one or more addressable devices. A device or an action associated with the addressable device loop has been disabled A fault condition is present on a monitored sounder circuit or on the addressable device loop sounders. A device or an action associated with the monitored sounder circuits or addressable sounders has been disabled. A fault condition is present on a monitored Relay circuit or on the addressable device loop outputs. A device or an action associated with the monitored relay circuits or an addressable output has been disabled. 13. ZONE Yellow Continuous A device or zone, or an action associated with them has been disabled. 19

14. FAULT OUTPUT Yellow Flashing Continuous A monitored output programmed to operate as a Fire Output is in the fault state. A monitored output programmed to operate as a Fire Output has been disabled. 15. DAY Yellow Continuous The system Day / Night mode timing has been overridden, and forced into the less sensitive day mode. The system has gone in the less sensitive day mode as programmed. 16. ROUTINE SERVICE Yellow Continuous The pre programmed service interval has expired and a routine maintenance check is due. 17. TECHNICAL ALARM Yellow Continuous A device programmed as Technical Alarm is in the alarm state and sending a Technical Alarm signal to the panel. 18. CONFIRMATION Yellow Continuous A smoke detector is in the alarm confirmation state, awaiting confirmation or reset. 19. DELAY Yellow Continuous An action has been started which utilises a programmed delay. 20. ALARMS Yellow Flashing Continuous The alarm sounders have been activated from the Sound Alarms button on the panel. The alarm sounders have been silenced whilst operating, and the system is awaiting a reset. 21. BUZZER SILENCED Yellow Continuous The control panel buzzer has been silenced whilst operating and will stay silenced until another fault or relevant action occurs. The control panel buzzer has been disabled at Access Level 3 (Engineer), and will remain silent until it is reinstated. However, the panel buzzer will still operate in the fire alarm state. 20

LOG BOOK Event Log Record all fire and fault events, whether or not an engineer was called Time Zone/Device Event Action Initials 21

Time Zone/Device Event Action Initials 22

Time Zone/Device Event Action Initials 23

Time Zone/Device Event Action Initials 24

Time Zone/Device Event Action Initials 25

Time Zone/Device Event Action Initials 26

Time Zone/Device Event Action Initials 27

Installation Details This section should be completed by the commissioning engineer at handover. Name of Responsible Person:... Name and Address of Installation:...... Ref. No. (if applicable):... Date of Handover:... Name and Address of Installer:...... Tel:. Fax:... Equipment: Control Panel: Quadnet V:. Serial No.:... No. of Loops used: No. of Zones used:.... Mains Supply:...... Loop 1 Loop 2 Loop 3 Loop 4 Total No. of Devices: No. of Detectors: No. of Call Points: No. of Sounders: No. of Interfaces: Loop +ve Continuity: Loop ve Continuity: Loop Screen Continuity: Loop +ve to -ve Resistance: Loop +ve to Screen Resistance: Loop ve to Screen Resistance: Loop Screen to Earth Resistance: Access Level 2A (User) code: (Default USER). Access Level 2B (Supervisor) code: (Default SUPR).. In an emergency call: Normal Hours:.. Out of Hours:.. 28