Theoritical Analysis For Miniature Vapor Compression Cycle Performance Using Microchannel And Finned Tube Condenser

Similar documents
Global Journal of Engineering Science and Research Management

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

2. HEAT EXCHANGERS MESA

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

Design and Development of Water Cooled Condenser for Domestic Refrigerator

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

REVIEW PAPER ON REFRIGERATION SYSTEM USING MICROCHANNEL CONDENSER

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

[Vali*, 5(2): February, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785

Keywords: Micro channel condenser, refrigeration system, heat transfer rate, refrigerant Effect.

Enhancement of COP in Vapour Compression Refrigeration System

PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

DESIGN AND ANALYSIS OF PIPE HEAT EXANGERS WITH INSIDE FINS

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Study and Investigation of Refrigeration System Using Microchannel Condensers and round tube condenser-review

Investigation and Optimization of Air Cooled Condenser of Chillers by Replacing Cu to Al Tubes

Waghmare Tushar Ramrao, D.S.Nakate

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Gandhinagar Institute of Technology Mechanical Engineering (Thermal Engineering) Semester II. Design of Heat Exchange Equipments [ ]

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

DESIGN, DEVELOPMENT AND TESTING THE

Performance of an Improved Household Refrigerator/Freezer

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

Experimental Analysis of a Stirling Refrigerator Employing Jet-Impingement Heat Exchanger and Nanofluids

Experimental Research and CFD Simulation on Microchannel Evaporator Header to Improve Heat Exchanger Efficiency

GSJ: VOLUME 6, ISSUE 6, JUNE GSJ: Volume 6, Issue 6, June 2018, Online: ISSN

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

EXPERIMENTAL ANALYSIS OF MICROCHANNEL CONDENSER USING R134a AND DROP IN SUBSTITUTE HYDROCARBON MIXTURE OF R290 AND R600a

Finned Heat Sinks for Cooling Outdoor Electronics under Natural Convection

Performance Study of Triple Concentric Pipe Heat Exchanger

Numerical Study on Improvement of COP of Vapour Compression Refrigeration System

INTRODUCTIONN com/nanotechnoly, 2015).

Design and analysis of household direct cool refrigerator with vertical evaporator

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Using Evaporative Cooling Methods for Improving Performance of an Air-cooled Condenser

Performance investigation of Air-conditioning system using ejector as expansion device

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

Modeling and Design of an Indirect Air Conditioning System Operating With Low GWP Zeotropic Mixtures

Heat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a

2.2. General view of Microchannel Heat Exchangers

Induction heating with the ring effect for injection molding plates

Optimized Finned Heat Sinks for Natural Convection Cooling of Outdoor Electronics


Development and Application of Micro Channel Heat Exchanger for Heat Pump

MAL-DISTRIBUTION MODEL OF HEAT EXCHANGERS IN MICRO CHANNEL EVAPORATOR

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

EFFECT OF DIVERSE STREAM PATTERNS ON THE PERFORMANCE OF SOLAR AIR HEATER

Thermal Analysis of Concentric Tube Heat Exchanger Using Louvered Strip Inserts

Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

Natural Convection Heat Transfer Augmentation from Heat Sinks using Perforated Fins: A Review

EXPERIMENTAL EVALUATION OF CONDENSATION HEAT TRANSFER COEFFICIENT OF R-417A IN HORIZONTAL TUBES

EFFECT OF INLET TEMPERATURE ON REYNOLDS NUMBER AND NUSSELT NUMBER WITH MIXED REFRIGERANTS FOR INDUSTRIAL APPLICATIONS

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

FUNDAMENTAL BASIS AND IMPLEMENTATION OF SHELL AND TUBE HEAT EXCHANGER PROJECT DESIGN: EVAPORATOR STUDY

Experimental Investigations of Different Types of Condensers on the Performance of Household Refrigerators

Modified Air Cooler with Split Cooling Unit

Solar air heater duct having triangular protrusions As roughness elements on absorber plate

Adsorption refrigeration system using waste heat

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

Investigation of Port Level Refrigerant Flow Mal-distribution in Microchannel Heat Exchanger

Performance Evaluation of VCRS with Nested Helical Shaped Condenser by Using R134a as Refrigerant

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Design Optimization of Variable Geometry Microchannel Heat Exchangers

Comparative Study of Transcritical CO 2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Numerical study of heat pipe application in heat recovery systems

International Journal Of Core Engineering & Management (IJCEM) Volume 2, Issue 9, December 2015

Implementation of Microchannel Evaporator for High-Heat-Flux Refrigeration Cooling Applications

TWO-PHASE MICRO-CHANNEL HEAT SINK FOR SPACE CRAFT THERMAL CONTROL

Control Method Of Circulating Refrigerant Amount For Heat Pump System

Falling Film Heat Exchangers for Solar Water Heaters

Design of Miniature Loop Heat Pipe

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

STUDY OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING DOUBLE PIPE HEAT EXCHANGER

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

Enhancement of COP using Nanoadditives in Domestic Refrigerator

Compression of Fins pipe and simple Heat pipe Using CFD

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

Transcription:

Theoritical Analysis For Miniature Vapor Compression Cycle Performance Using Microchannel And Finned Tube Condenser Issam Mohammed Ali Ahmed Qasim Mohammed Marwa Sallah Neama Mechanical Eng. Dept Air- cond. Eng. Dept. Air- cond. Eng. Dept. College of Engineering Engineering Tech. College Engineering Tech. College Baghdad University Middle Tech. University Middle Tech. University Iraq Iraq Iraq juburyima@gmail.com dr.ahmed56@yahoo.com marwaalmohja92@gmail.com Abstract Theoretical and experimental study of miniature vapor compression cycle working with R-134a at 550 W cooling capacity, using microchannel and finned tube condenser was presented. Microchannel condenser that used in this work made from aluminum. This condenser have 12 rectangular channels with hydraulic diameter 1.07 mm, and condenser dimensions (25 11.8 2 cm) with 146 micro fins per tube. In theoretical work, miniature vapor compression cycle with microchannel and conventional condenser was analyzed. The effect of channel diameter change on refrigerant side heat transfer coefficient was taken into account. The theoretical result indicates that, using microchannel instead of finned tube condenser lead to enhancement in refrigerant side heat transfer coefficient by 31%, Increasing heat rejection by 36%, and coefficient of performance by 23%. Also it shows that refrigerant side heat transfer coefficient decreases by 29%, when hydraulic diameter increases from 0.85 to 1 mm. The result indicate that using microchannel condenser can reduce the total area of condenser by 53%, for the same amount of heat rejection. Keywords microchannel condenser; miniature vapor compression cycle; hydraulic diameter I. INTRODUCTION Vapor Compression Cycle (VCR) provide a progress means for removing large amounts of heat and is a compelling technology to improvement the performance and reliability of electronics [1]. miniature vapor compression cycle have small size, it can provide high cooling capacity by using microchannel condenser, which reject large amount of heat to the ambient. Due to the space limitation, system that proposed should contain micro channel evaporator or condenser and small scale compressor like one that used in this work. This type of condenser can be effectively used as energy efficient system. Micro and mini channel condenser are different from conventional channel in term of channel hydraulic diameters. Micro channel condenser is used to effectively absorb and dissipate heat from the surroundings more efficient than conventional condenser [2]. Micro or mini channel condenser have been widely used in cooling system of automotive and also being used in stationary heating, ventilation, air conditioning and refrigeration industry. this type have rectangular tubes divided into many micro channel in which refrigerant flow. Multi louver fins sandwiched between this tubes to dissipate heat by cooled air flow across this fins The flat tubes allow maximization of the air side heat transfer surface area, and the multiple micro refrigerant channels within the flat tubes increase refrigerant side heat transfer [3]. Through much research efforts, theoretically tested of miniature vapor compression cycle with microchannel condenser have been proposed. Numerical simulation of micro channel condenser for domestic refrigerator was introduced by Zhang Huiyong et al. [4] in 2010, to evaluate design parameter for different tube length and tube diameter of micro channel condenser. Heat exchanger consisted of serpentine fin brazed to tube with internal channel in micro size was theoretically analyzed by J.R. Garcia-Cascales et al. [5] 2010, so they built model to studies the condensation of R134a and R410a in compact condenser and compared the results with number of other correlation. While S.M.Gaikwad et al. [6] in 2013, performed a numerical study to the fluid flow inside micro channel condenser by ANSYS Fluid flow (Fluent) to compare characteristics of micro channel condenser during counter and parallel flow. Condenser used with 1,1.5,2,2.5,3,3.5,4,4.5 m/s inlet velocity and w=0.4 mm H=0.4 mm L=10 mm geometry. In this work, an attempt was made to replace a plate finned tube condenser of a simple vapor compression cycle that shown in Figure (1), by microchannel condenser. Fig. (1) Schematic Diagram of the Vapor compression cycle JMESTN42352233 7422

II. THEORY To evaluate the overall heat transfer coefficient for a tube with fins, first the air-side convective heat transfer coefficient should be calculated. Since the flow of air in both plate fin and micro channel condenser are over the tube and air forced by fan, so it can be said that are same for both types of condenser. Therefore, the work of (Mc Quiston and Parker, 1994) is used [7]. The convective heat transfer coefficient for dry outer surface of the condenser dependent on the Colburn j-factor is: h a = j c G max cp a 2 (1) pr a 3 While the Prandtl (pr a ) number can be expressed as: Pr a = μ a cp a k a (2) Because of channel size effect on heat transfer rate of condenser, heat transfer coefficient cannot be accounted by using models provided for condenser with conventional channel [8]. For this reason heat transfer coefficient for both types was analyzed by different correlations. A. Micro Channel Condenser Refrigerant Side Model Koyama et al. suggested simplified correlation to calculate heat transfer coefficient of R-13a inside rectangular channel as expressed below [9]: α = k f d h Nu (3) Nu = (Nu 2 f + Nu 2 b ) 1 2 (4) Nu f : is forced convection condensation term and can be expressed as Nu f = 0.0112 pr 1.37 f ( g 0.7 ) Re X f (5) tt Re f = G(1 x)d h μ f (6) G = m A i (7) A i = [2 n rec (a + b) + n cir (a + πb)]l (8) g 2 = 1 + 21(1 e 0.319d h)x tt + X tt 2 (9) And X tt is Lockhart-Martinelli parameter which expressed as X tt = ( 1 x x )0.9 ( ρ v ) 0.5 ( μ l ) 0.1 (10) ρ l μ v On the other hand, Nu b is the gravity controlled convection condensation [10] which is calculated depending on Galileo number Ga f, void fraction ε, and Bond number Bo as follow: Nu b = 0.725(1 e 0.85 Bo ) H (ε) ( Ga fpr f ph f ) 1 4 (11) Bo = d h 2 g(ρ f ρ g ) (12) σ And H (ε) is the function of void fraction can be calculated as: H (ε) = ε + [10(1 ε) 0.1 8.9] ε (1 ε) (13) Where void fraction can be expressed as: ε = 1 + ρ g 1 x ρ f x ρ f (0.4 + 0.6 ρg +0.41 x x 1+0.4 1 x x ) 1 (14) ( ) While Galileo number Ga f can be calculated as follow: Ga f = gρ f 2 3 d h μ 2 (15) f And ph f is phase change number that expressed as: ph f = cp f (T r T w )/h fg (16) B. conventional Condenser Refrigerant Side Model The heat transfer in the single phase includes (superheated and sub-cooled) region. For this study heat transfer coefficient are calculated by using the correlation of Kays and London (1984) [11] as: h r,sph = a G r,sph cp r,sph Re b Di pr 2 r,sph 3 (17) Also, heat transfer coefficient in the sub-cooled region can be expressed as: Also, heat transfer coefficient in the sub-cooled region can be expressed as: h r,sc = 0.16 k sc Re 0.89 0.12 D r,sc pr r,sc (18) i While The heat transfer coefficient of two phase flow can be calculated by using Shah correlation (1979) [12] which are presented as follow: h r,tp = h r,l [0.55 + 2.09 p 0.8] (19) While the heat transfer coefficient liquid region is calculated by using the DittusBoelter equation [13]: h r,l = 0.023 k sc D i Re r,sc 0.8 pr r,sc 0.4 (20) III. RESULT AND DISCUSSIONS In this work, area of microchannel condenser was calculated by using equation represented in chapter three, while the area of finned tube condenser was calculated by using HTRI software. The result shows that the area was reduced by 53%, if conventional condenser was replaced by microchannel condenser. The change in the predicted value of refrigerant side heat transfer coefficient for microchannel and finned tube condenser with ambient temperature is shown in Figure (2). The heat transfer coefficient of microchannel reduces from 347 to 250 W/m 2.k while in finned tube condenser decreases from 240 to 110 W/m 2.k, with increase in temperature from 30 to 40 o C. It is clear that heat transfer coefficient of microchannel is higher than finned tube condenser due to multiple rectangular microchannels within the flat tubes, which is increase refrigerant side heat transfer area. JMESTN42352233 7423

Fig (2) theoretical heat transfer coefficient vs. ambient temperature While in Figure (3), it can observed the reduction in heat transfer coefficient of microchannel and finned tube condenser, with the increase in the evaporator load from 100 to 300 W, the heat transfer coefficient of microchannel decreased from 296 to 260 w/m 2.k, while for finned tube condenser reduced from 169 to 145 w/m 2.k. The heat transfer coefficient of microchannel is higher than that of finned tube condenser by 37% at load 100 W. Fig. (4) Nusselt number vs. ambient temperature Figure (5), depicts the variation of Nusselt number with load imposed on evaporator. It shows that increasing load from 100 to 300 W means decreasing in Nusselt number from 4.52 to 3.97 for microchannel and from 3 to 2.5 for finned tube condenser. Also the Nusselt number of microchannel is greater than that of finned tube condenser by about 33%. Fig. (3) theoretical heat transfer coefficient vs. load imposed on evaporator. Figure (4), demonstrates the change in Nusselt number with ambient temperature. The result shows that enhancement in Nusselt number by about 34% using microchannel condenser instead of finned tube condenser. Fig. (5) Nusselt Number vs. load imposed on evaporator The effect of ambient temperature and evaporator load on heat rejection from condenser are investigated in Figure (6) and (7).The heat rejection from condenser decreases with increase in ambient temperature and load on evaporator. Microchannel condenser heat rejection decreases from 1170 to 900 W, and reduces from 850 to 670 W for finned tube condenser with the increase in ambient temperature. While it decrease slightly by 2.9% for microchannel, and 2.3% for finned tube condenser when the evaporator load increased. Also it may be noted that the heat rejection from microchannel is greater than finned tube condenser by 36%. JMESTN42352233 7424

Fig. (6) heat rejection vs. ambient temperature Fig. (8) coefficient of Performance vs. ambient temperature The effect of increasing evaporator load on COP of the system is indicated in Figure (9). The COP of system with microchannel decreases from 4.5 to 4.12, while decreases from 3.53 to 3.27 with conventional condenser, when evaporator load increases from 100 to 300 W. Also it can be noted that the coefficient of performance of cycle with microchannel condenser is by 23%, at ambient temperature 30 o C and load 200w condenser. Fig. (7) heat rejection vs. load imposed on evaporator Figure (8) illustrates that the coefficient of performance of miniature vapor compression cycle with microchannel and finned tube condenser, is inversely proportional with ambient temperature. It slightly decrease by 26% for microchannel and by 24% for finned tube condenser with increase in ambient temperature. Also it can be noted that the coefficient of performance of cycle with microchannel condenser is greater than that of cycle with finned tube condenser by 23%, at ambient temperature 30 o C and load 200w. Fig. (9) coefficient of Performance vs. load imposed on evaporator The change in value of refrigerant side heat transfer coefficient of microchannel condenser with respect to hydraulic diameter of condenser channel, is depicted in Figure (10). The increase in hydraulic diameter of channel leads to decrease in heat transfer coefficient of condenser. This is due to reduce in contact area between refrigerant and surface. From Figure (7) it can be observed that the heat transfer coefficient increases by 29%, when hydraulic diameter of channel decreases from 1mm to 0.85 mm. JMESTN42352233 7425

Fig. (10) variation of heat transfer coefficient vs. channel hydraulic diameter IV. CONCLUSIONS: 1. Using microchannel instead of plate fin condenser can reduce the total area of condenser by 53%, for the same amount of heat rejection. 2. From theoretical results, it can be concluded that using microchannel instead of plate fin condenser leads to: a. Improvement in refrigerant side heat transfer coefficient by 31%. b. Nusselt number increased by 34%. c. Increasing in heat rejection by about 36%. d. The coefficient of performance for miniature vapor compression cycle increased by 23%. 3. Decrease in hydraulic channel diameter of microchannel condenser from 1 to 0.85 mm, leads to enhancement in refrigerant side heat transfer coefficient by 29%. Symbols j c : Colburn j-factor G max : maximum mass flux of air (kg/m 2 s) Cp a : constant pressure specific heat for air (kj/kg K) d h : is a hydraulic diameter of channels m : mass flow rate of refrigerant (kg/s) A i : is the cross section n rec : number of rectangular channel a: is a height of channel b: is the width of channel n cir : number of circular channel g: gravity ρ f : density of refrigerant at liquid phase ρ g : density of refrigerant at vapor phase σ: surface tension (N/m) h g : is enthalpy of refrigerant at vapor phase h f : is enthalpy of refrigerant at liquid phase h r,sph : heat transfer coefficient in the super-heated region (W/m2. k) Cp r,sph : specific heat at constant pressure (kj/ kg. K). References [1]. Lee, J., & Mudawar, I. (2005). Two-phase flow in high-heat-flux micro-channel heat sink for refrigeration cooling applications: Part I pressure drop characteristics. International Journal of Heat and Mass Transfer, 48(5), pp 928-940. [2]. Wu, z., & Du, r. (2011). "Design and experimental study of a miniature vapor compression refrigeration system for electronics cooling". Applied thermal engineering, 31(2), pp 385-390. [3]. Kandlikar, S., Garimella, S., Li, D., Colin, S., & King, M. R. (2005). "Heat transfer and fluid flow in minichannels and microchannels". Elsevier [4]. Zhang, H., Li, J., & Li, H. (2010). Numerical simulations of a micro-channel wall-tube condenser for domestic refrigerators. Tsinghua science & technology, 15(4), pp 426-433. [5]. Garcia-Cascales, J. R., Vera-Garcia, F., Gonzalvez-Macia, J., Corberan-Salvador, J. M., Johnson, M. W., & Kohler, G. T. (2010). Compact heat exchangers modeling: Condensation. international journal of. 135-147 refrigeration, 33(1), pp [6]. Gurav, r. B., Gaikwad, s. M., Patil, j. D., Ramgude, a. A., & Purohit, p. (2013). Cfd simulation on fluid flow in micro channel heat exchanger. International journal of global technology initiatives, 2(1), ppe23-e30. [7]. Hsieh, Y. C., & Lin, Y. T. (1997). Performance of plate finned tube heat exchangers under dehumidifying conditions. Journal of Heat Transfer, 119, 109 [8]. Kandlikar, S., Garimella, S., Li, D., Colin, S., & King, M. R. (2005). "Heat transfer and fluid flow in minichannels and microchannels". Elsevier [9]. Koyama, S., Kuwahara, K., Nakashita, K., & Yamamoto, K. (2003). An experimental study on condensation of refrigerant R134a in a multi-port extruded tube. International journal of refrigeration, 26(4), pp 425-432. [10]. Sakamatapan, K., Kaew-On, J., Dalkilic, A. S., Mahian, O., & Wongwises, S. (2013). Condensation heat transfer characteristics of R-134a flowing inside the multiport minichannels. International journal of heat and mass transfer, 64, pp 976-985. [11]. Kays, W. M., & London, A. L. (1984).. exchangers Compact heat [12]. Kakac, S., Liu, H., & Pramuanjaroenkij, A. (2012). Heat exchangers: selection, rating, and thermal design. CRC press. JMESTN42352233 7426

[13]. Kothandaraman, C. P. (2006). Fundamentals of heat and mass transfer. New age international. Journal of Multidisciplinary Engineering Science and Technology (JMEST) JMESTN42352233 7427