ISSN: [Farooque* et al., 6(5): May, 2017] Impact Factor: 4.116

Similar documents
Performance Assessment of Water Cooled Condenser Refrigeration System

CHAPTER 1 INTRODUCTION

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

CHAPTER 1 INTRODUCTION

Enhancement of COP using Nanoadditives in Domestic Refrigerator

Chapter 11 REFRIGERATION CYCLES

Evaluation of COP in Refrigeration System by using Different Refrigerants

Thermodynamics I. Refrigeration and Heat Pump Cycles

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

A Comparison Between Refrigerants Used In Air Conditioning

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

Oyelami S., Bolaji B. O.

Thermodynamics II Chapter 5 Refrigeration

(ME-225) HEATING, VENTILATION AND AIR-CONDITIONING SYSTEM

Fabrication of Hot and Cold Water Dispenser

Chapter 10. Refrigeration and Heat Pump Systems

Chapter 11 REFRIGERATION CYCLES

Performance and Analytical Study of Cooler Cum Air Conditioner based on Vapour Compression Refrigeration System

Refrigeration and Air Conditioning

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Assessment of LPG as a possible alternative to R-12 in domestic refrigerators

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

DEEPAK PALIWAL, S.P.S.RAJPUT

Ammonia. Background on ammonia as a refrigerant

PERFORMANCE OF REFRIGERATOR USING R-600A AS REFRIGERANT

Chapter 2. Alternatives to HCFCs and their Characteristics

η second law = Second law efficiency

Design & Fabrication of Hybrid Cooler

CH2351 Chemical Engineering Thermodynamics II Unit V Refrigeration. Dr. M. Subramanian

LPG Refrigerator. October 2017 IJIRT Volume 4 Issue 5 ISSN:

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Sarthak Thakar, 2 R.P.Prajapati 1

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

we will examine only the vapour compression systems transfers to the Carnot cycle can serve as the initial model of the ideal refrigeration cycle.

Comparative Performance Analysis of Domestic Refrigerator using R12, R134a and R600a Refrigerants

Refrigeration Technology in Building Services Engineering

Presentation on HVAC: Heating Ventilation Air Conditioning

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Refrigeration Cycle Demonstration Unit R633

Design of LPG Refrigeration System

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

ISSN Electronic International Interdisciplinary Research Journal (EIIRJ) Bi-monthly Reviewed Journal Mar- April 2015

Refrigeration Cycle Demonstration Unit R634

Evaluation of Vapour Compression Refrigeration System Using Different Refrigerants

IJESRT. (I2OR), Publication Impact Factor: (ISRA), Journal Impact Factor: 2.114

Effects of evaporator load on vapour compression refrigeration system using ecofriendly hydrocarbon refrigerants with sub cooling

ENHANCEMENT OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING NANOFLUIDS

Chapter 10 Lyes KADEM [Thermodynamics II] 2007

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Design and Fabrication of Water Refrigeration System by Creating Vacuum

AIM: TO STUDY THE PERFORMANCE OF THE DOMESTIC REFRIGERATION RIG.

Thermodynamic study of R134a in Vapour Compression Refrigeration System in Summer Climate

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

A COMPARATIVE STUDY FOR RETROFITTING OF R-12 VAPOUR COMPRESSION REFRIGERATION SYSTEM BY ECO- FRIENDLY REFRIGERANTS R-134A, R-413A, R-423A

International Journal of Advance Engineering and Research Development

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

Scientific Journal Impact Factor: (ISRA), Impact Factor: Methodology. [Yadav, 3(9): September, 2014] ISSN:

Experimental Investigation of Hot water Fired R134A-DMAC VARS System at Various Heat Source Temperatures

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

REVIEW OF DESIGN OF SINGLE EFFECT SOLAR POWERED VAPOUR ABSORPTION AIR CONDITIONING SYSTEM

ECO-FRIENDLY REFRIGERANTS. Dr Alka Bani Agrawal Professor,Mechanical Engg UIT,RGPV

Effect of capillary diameter on the power consumption of VCRS using different refrigerants

Chapter 11. Refrigeration Cycles. Study Guide in PowerPoint

Combination unit to support instruction in Thermodunamics, Fluid Mechanics, and Heat Transfer

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Keywords: Climate change; ozone depletion; Montreal protocol; eco-friendly refrigerant; hydrocarbon refrigerant; performance analysis.

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

Performance Enhancement of Mini Refrigerator with Phase Change Materials

Chapter 9. Refrigeration and Liquefaction

Why Hydrocarbons Save Energy

NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

Refrigeration and Air Conditioning

Low GWP Refrigerants for Air Conditioning Applications

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

ISSN Vol.08,Issue.21, November-2016, Pages:

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

Energy Use in Refrigeration Systems

To Improve Cop of Domestic Refrigerator with the Help of Water Cooling Condenser

The Problem of Counterfeit Refrigerants

R134a Refrigerant in Vapour Compression Cycle: A Review Paper

REFRIGERATION TUTOR. OBJECTIVE: To perform test on the refrigeration tutor to determine different COPs and other performance parameters.

How to deal with ...R410A MITSUBISHI ELECTRIC R32 R125 R410A AIRCONDITIO NING

Transcription:

IJESRT INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY CALCULATION OF COEFFICIENT OF PERFORMANCE IN VAPOUR COMPRESSION REFRIGERATION SYSTEM BY USING R600 REFRIGERANT Umar Farooque*, Mr. Yogesh Parkhi * Associate professor Department of Mechanical Engineering School of Research and Technology, Bhopal DOI: 10.5281/zenodo.579966 ABSTRACT This Synopsis deals with experimental investigation by using R600 refrigerant and to calculate the value of COP. We have all experienced a sensation of heat when passing behind a functioning refrigerator or air conditioner. The cause of this phenomenon is the air condenser, a heat exchanger made up of tubes with air fins attached to the back of the device. This is where the cooling fluid condenses by releasing its heat into the ambient air. To limit the system s energy consumption, humidification processes were initiated. The principle consists of saturating the ambient air in contact with the exchanger by projecting fine water droplets. Humidification of the air intensifies the heat exchange on the air side and reduces the cooling fluid s condensation temperature. This lowers the compression rate in the cooling cycle and improves the compressor s consumption of electrical power INTRODUCTION Refrigeration may be defined as the process to achieve and keep an enclosed space at a temperature lower than its surrounding temperature. This is done by continuous extraction of heat from the enclosed space whereas the temperature is below than that of the surrounding temperature. Nowadays refrigeration is something that is indispensable in our daily life. One of the most important applications is the preservation of perishable foods and keeps the food in fresh condition. There is no doubt that food, is just like air and water are necessities for livings. People often utilize refrigeration to chill their drinks, making it more scrumptious. In additional, refrigeration also being used in providing thermal comfort to people by means of air conditioning process. Historically, it is generally agreed that the first refrigeration machine was introduced in 1755 which was made by Scottish professor William Cullen. However, he did not use his discovery for any practical purpose. In the following 50 years, an American inventor, Oliver Evans, designed the first refrigeration machine. An American physician, John Gorrie, built a refrigerator based on Oliver Evans' design in 1844 to make ice to cool the air for his yellow fever patients. A German engineer named Carl von Linden patented not a refrigerator but the process of liquefying gas in 1876 that is part of basic refrigeration technology. Generally refrigeration systems can be classified in 3 main cycle systems which are vapor compression refrigeration system, vapor absorption refrigeration system, and gas cycle refrigeration system. However the vapor compression refrigeration system is the most widely used in the refrigeration process. It is adequate for most refrigeration applications. The ordinary vapor compression refrigeration systems are simple, inexpensive, reliable and practically maintenance free. OBJECTIVES The main objective of this report is to improve the configuration of the refrigerator test rig to a simpler configuration. and the effect of the charge quantity of the refrigerant on the refrigeration system. Finally, obtain the optimum COPr by using the data collected from the experiment. To be able to do this, the exact locations of the points of interest at where the data (temperature and pressure) should be collected must be identified correctly. SCOPES Literature Study The literature study is mainly focused on the fundamental of working principle of vapor compression refrigeration cycle. The working principle of each of the 4 main components, compressor, condenser, expansion device and evaporator are also in the region of concerned. [331]

LITERATURE REVIEW THE SECOND LAW OF THERMODYNAMICS There are 2 classical statements of second law of thermodynamics which are the Kelvin-Planck statement and the Clausius statement. Both of Kelvin-Planck and Clausius statements are 2 equivalent expressions of the second law of thermodynamics. For refrigerators or heat pump, Clausius statement is being related to which is expressed as It is impossible to construct a device that operates in a cycle and produces no effect other than the transfer of heat from a lower-temperature body to a higher temperature body (Cengel, 2008). There is commonsense that heat does not naturally transfer on its own from a colder medium to a warmer medium. The Clausius statement simply means that if a cyclic device that transfers heat from a colder medium to a warmer medium will be impossible to be achieved or construct, unless this cyclic device produce a net effect on other (Cengel, 2008). For an example, a cyclic device that transfers heat from a cold medium to a warmer one has long been constructed which is the domestic refrigerator. A domestic refrigerator is in complete compliance with the Clausius statement of the second law of thermodynamics. The Clausius statement simply states that a refrigerator cannot operate unless its compressor is driven by an external power source, such as an electric motor. In this case, the compressor leaves a trace in the surroundings by consuming some energy in the form of work by the electric motor so that to transfer heat from the colder body to a warmer one (Cengel, 2008). REFRIGERANTS Over the last decade, the choice of refrigerant used in a refrigeration system has been becoming a worldwide issue as mainly in response to the environmental issues of holes in the ozone layer and global warming or greenhouse effect. Previously people had no much discussion on the selection of refrigerant. The refrigerants chosen were all based on the capability of heat absorption and releasing of the fluids, which depends on the latent heat of vaporization of the fluids. As the majority of applications could be met by the well known and well tested fluids, R-11, R- 12, R-22, R-502 and ammonia (R-717). However only ammonia can be considered environmental friendly today, but still it is not readily suited to commercial or air-conditioning refrigeration applications because of its toxicity, flammability and attack by copper. The ozone layer beyond the atmosphere provides a filter for ultraviolet radiation, which is harmful to us. The ozone depletion potential of the refrigerants such as R-11, R-12, R-114, and R502 is due to the emissions into the atmosphere of chlorofluorocarbons (CFCs). The Montreal Protocol in 1987 agreed that the production of hydro chlorofluorocarbons (HCFCs) would be phased out by 1995 with a consumption cap, followed by a 35 % reduction in consumption beginning in 2004 and alternative fluids developed (Trott, 2000). The phaseout of HCFCs is earlier in some European countries, with for example Germany having a phaseout of R-22 in new equipment starting in 2000, and Sweden banning HCFC use for new equipment after 1997, and service after 2001 (Murphy, 1998). VAPOR COMPRESSION REFRIGERATION SYSTEM Ideal vapor compression refrigeration cycle The Temperature-Entropy (T s ) and Pressure-Enthalpy ( p h ) diagram for the ideal vapor compression refrigeration cycle are shown in Figure 2.1. [332]

Figure 2.1: (a) T s and (b) p h diagrams for the idea vapor compression refrigeration cycle Source: Cengel and Boles (1998) The vapor compression refrigeration system is the most common refrigerationsystem that is being used nowadays. It is widely used for all purpose refrigeration. It iscommonly used for all industrial purposes from a small domestic refrigerator to big airconditioning plant. The vapor compression refrigeration system is an improved type ofsystem of air refrigeration system. In this system, a particularly suitable working fluid isused to run the whole system and we called this working fluid as refrigerant. Therefrigerant used is circulating throughout the system alternately condensing andevaporating without leaving the system (Khurmi, 2006). Vapor Compression Refrigeration System A vapour compression refrigeration system is an improved type of air refrigeration system in which a suitable working substance, termed as refrigerant, is used. It condenses and evaporates at t e m p e r a t u r e s a n d p r e s s u r e s close to t h e atmospheric conditions. The refrigerants, usually, used for this purpose are ammonia (NH3), carbon dioxide (CO2) and sulphur dioxide (SO2). The refrigerant used, does not leave the system, but is circulated throughout the system alternately condensing and evaporating. In evaporating, the refrigerant absorbs its latent heat from the brine (salt water) which is used for circulating it around the cold chamber. While condensing, it gives out its latent heat to the circulating water of the cooler. The vapour compression refrigeration system is, therefore a latent heat pump, as it pumps its latent heat from the brine and delivers it to the cooler. The vapour compression refrigeration system is now-a-days used for all purpose refrigeration. It is generally used for all industrial purpose from a small domestic refrigerator to a big air conditioning plant. METHODOLOGY DESCRIPTION OF THE TEST RIG:- Refrigeration test rig consists of a hermetically sealed compressor, air-cooled condenser, capillary and an evaporator. The evaporator cools the water in a calorimeter. A heater is provided in the calorimeter, whose output can be varied by a dimmer stat. Separate pressure gauges are provided to measure Condenser & Evaporator pressures. Five suitable thermometers are provided to measure temperatures at various locations (refer the Layout). Two energy meters are provided to measure energy supplied to compressor and heater. Suitable H.P.L.P. cutout, Voltmeter and ammeter are provided in the unit. [333]

FLOW-CHART EXPERIMENT WORK DATA COLLECTION DATA ANALYSIS COMPARISION WITH CONVENTIONAL REFRIGERATOR RESULT REFRIGERATION SYSTEM TEST RIG 3.3.1 SPECIFICATIONS: 1. Cooling capacity: 30 kg of ice in 24 hours. 2. Insulation: PUF Insulation 3. Number of ice cans: 12 4. Size of tank: (0.83*0.345*0.345) m3. 5. Height of the tank: 0.27 m 6. Size of the ice can: (0.325*0.116*0.078) m3. EQUIPMENT COMPRESSOR The low pressure and temperature vapour refrigerant from evaporator is drawn into the compressor through the inlet or suction valve A, where it is compressed to a high pressure and temperature. This high pressure and temperature vapour refrigerant is discharged into the condenser through the delivery or discharge valve B CONDENSOR The condenser or cooler consists of coils of pipe in which the high pressure and temperature vapour refrigerant is cooled and condensed. The refrigerant, while passing through the condenser, gives up its latent heat to the surrounding condensing medium which is normally air or water RECEIVER The condensed liquid refrigerant from the condenser is stored in a vessel known as receiver from where it is supplied to the evaporator through the expansion valve or refrigerant control valve. EXPANSION VALVE It is also called throttle valve or refrigerant control valve. The function of the expansion valve is to allow the liquid refrigerant under high pressure and temperature to pass at a controlled rate after reducing its pressure and temperature. Some of the liquid refrigerant evaporates as it passes through the expansion valve, but the [334]

greater portion is vaporized in the evaporator at the low pressure and temperature. EVAPORATOR An evaporator consists of coils of pipe in which the liquid-vapour refrigerant at low pressure and temperature is evaporated and changed into vapour refrigerant under high pressure and temperature to pass at a controlled rate after reducing its pressure and temperature. Some of the liquid refrigerant evaporates as it passes through the expansion valve, but the greater portion is vaporized in the evaporator at the low pressure and temperature OBSERVATION TABLE Sr. no. Description Symbol Reading 1 Condenser pressure Pc bar 2 Evaporator pressure Pe bar [335]

3 Condenser inlet Temp. Tci (T1) C 4 Condenser outlet Temp. Tco(T2) C 5 Evaporator inlet Temp. Tei(T3) C 6 Evaporator outlet Temp. Teo(T4) C 7 Time Taken for 10 revolution of energy meter of compressor Tc sec 8 Time Taken for 10 revolution of energy meter of heater Th sec 9 Temp. of water T5 C CALCULATION & EXPECTATION OUTCOMES CALCULATIONS [336]

EXPECTED OUTCOMES We are going to use R600 to find the COP at different temperature in series. It is a new refrigerant which is launched in the market. REFERANCES [1] ANSI / ASHRAE Standard (1986). Standard Method for Temperature Measurement. Atlanta: (ANSI / ASHRAE 41.1-1986 (RA 2001). [2] ANSI/ASHRAE Standard (1989). Standard Method for Pressure Measurement. Atlanta: (ANSI / ASHRAE 41.1-1986 (RA 2001). [3] Baustian, J.J., Pate, M.B., Bergles, A.E., 1988. Measuring the concentration of a flowing oil refrigerant mixture: instrument test facility and initial results. ASHRAE Transactions, Vol. 94, No. 1, pp167 177. [4] Bi S., Guo K., Liu Z., 2011. Performance of a domestic refrigerator using TiO2-R600a nanorefrigerant as working fluid. Energy Conversion and Management, Vol. 52, No. 1, pp. 733-737. [5] Bi S., Shi L. and Zhang L., 2007. Performance study of a domestic refrigerator using R134a/mineral oil/nano-tio2 as working fluid. ICR07-B2-346. [6] Brinkman, H.C., 1952. The viscosity of concentrated suspensions and solution. The Journal of Chemical Physics, Vol.20, pp. 571 581. [7] Hamilton, R.L., Crosser, O.K., 1962. Thermal conductivity of heterogeneous two-component systems. Industrial and Engineering Chemistry Fundamentals, Vol. 1, No. 3, pp. 187 191. [8] Jensen, M.K., Jackman, D.L., 1984. Prediction of nucleate pool boiling heat transfer coefficients of refrigerant oil mixtures. Journal of Heat Transfer, Vol. 106, pp. 184 190. [9] Jwo et.al, 2009. Effect of nano lubricant on the performance of Hydrocarbon refrigerant system. J. Vac. Sci. Techno. B, Vol.27, No. 3, pp. 1473-1477. [10] Kedzierski, M.A., Kaul, M.P., 1993. Horizontal nucleate flow boiling heat transfer coefficient measurements and visual observations for R12, R134a, and R134a/ester lubricant mixtures. In: Proceedings of the 6th International Symposium on Transport Phenomena in Thermal Engineering, Vol. 1, pp. 111 116. [11] Whitman, C. W., Johnson, W. M and Tanczyk, J. A. (2000). Refrigeration and Air Conditioning Technology. 4th edition. Delmar Thomson Learning, USA. CITE AN ARTICLE Farooque, U., & Parkhi, Y., Mr. (2017). CALCULATION OF COEFFICIENT OF PERFORMANCE IN VAPOUR COMPRESSION REFRIGERATION SYSTEM BY USING R600 REFRIGERANT. INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY, 6(5), 331-337. doi:10.5281/zenodo.579966 [337]