I N T E G R T E D P R O G R M M B L E OPTIMIZE ERV USBILITY ND PERORMNCE R ENE W I R E E V E RY WHE RE E V E R Y G E O G R P H Y, E V E R Y C L I M T E, E V E R Y H O M E, EVERY BUILDING ND EVERY PPLICTION
INTEGRTED PROGRMMBLE Renewire s INTEGRTED PROGRMMBLE optimize the sability and performance of or commercial ERVs by improving fnctionality, enabling intelligent controls, streamlining operations and boosting efficiencies. This is accomplished via sophisticated factory-installed microprocessor controls and sensors that provide stand-alone ERVs with Direct Digital Control (DDC) and/or Bilding Management System (BMS) control interface. KEY BENEITS Optimize sability: w Maximize ERV fnctionality and intelligent control via remote Ethernet accessibility and BMS connectivity withot third-party interface. wstreamline operations by easily managing and changing ERV control parameters via an advanced ser interface. wincrease ptime reliability throgh constant system monitoring. wchieve cleaner and healthier indoor air via IQ-based ERV control. Improve performance: wspport effective and efficient ERV performance with real-time data trending and logging capabilities. wenhance ERV control via access to real-time airflow rates, airstream temperatre and airstream hmidity. wacilitate fast and easy ERV pkeep and maintenance with real-time fan, filter and bypass stats. Increase capabilities: wexpand ERV connectivity via access to a wide range of open standard protocols, inclding BCnet and Modbs. wbroaden ERV interoperability by connecting to third-party eqipment and receiving third-party signals for nit control. wexpand ERV-application scope by meeting new code reqirements and the needs of instittional cstomers reqiring DDC controls in mechanical eqipment. Simplify operations: wchieve easier ERV setp, commissioning and balancing via simple-to-install controls. wimprove operational efficiencies by easily commnicating ERV stats, airflows, temperatres and hmidity. wllow for more flexible installations by enabling ERVs to be interconnected with a BMS, operated independently or rn in concert with other ERVs. PPLICTIONS The controller is available as an option for all commercial ERVs and RD-Series nits, and can be applied to all Renewire applications. MODELS Standard Controls via dry contact and relays Or ERV nits are provided with a dry contact that can be sed to control the nit with a variety of low-voltage (4VC) control devices sch as remote switches or relays. In addition, third-party analog otpt can be sed to operate the ERV. NEW Enhanced Controls Carel [c.pcomini] with or withot BCnet Enhanced controls offer atomated control, inclding temperatre and hmidity control with data trending via microprocessor controls and sensors that enable BMS connectivity. NEW Premim Controls Carel [c.pcomini] with expansion modle with or withot BCnet Premim controls inclde all fnctionality of enhanced-controls capabilities, as well as airflow and IQ monitoring, demand control, electric or gas heating options, as well as RD-Series cooling and heating control.
E R V W I T H I N T E G R T E D P R O G R M M B L E C O N T R O L S EXHUST N OPERTION OPTIONS E xhast fan ON/O stats ixed fan speed ariable fan speed V S pply fan E xhast airflow control R oom pressre control HEXINH Interior shown D ct static pressre control tracking control E IR L O IR L O W W TERMINL BLOCKS VD UTO/MNUL CONTROL SUPPLY N OPERTION OPTIONS S pply fan ON/O stats ixed fan speed Variable fan speed S pply dct static oom pressre control R O or VOC C TEMPERTURE ( and E) MICROPROCESSOR ILTER STTUS (all filters) TEMPERTURE & HUMIDITY (O and R) demand control S pply airflow control pressre control CONTROL CPBILITIES HETING/COOLING COIL CONTROL REMOTE DISPLY ISOLTION DMPER ECONOMIZER BYPSS ( R D - S E R I E S O N LY ) HETING/COOLING COIL CONTROL ( R D - S E R I E S O N LY ) CO IQ OCCUPNCY SMOKE DETECTOR In conjnction with nit monitoring and controls, RD heating and cooling fnctions can now also be monitored and controlled via or onboard premim control package. 3
INTEGRTED PROGRMMBLE ETURE COMPRISON NEW NEW STNDRD ENHNCED PREMIUM T GLNCE þ Commnication interface via BMS þ Modbs TCP/IP, Bacnet MSTP/IP þ DIN-rail monted controller with display þ Integrated Ethernet interface þ Battery-powered internal programmable time clock þ Temperatre, hmidity and airflows þ Monitoring and logging capabilities for alarm conditions þ Handheld/remote ser terminal þ Easy to se þ actory pre-programmed seqences of operation þ Data trending capabilities bility to atomatically enable and disable nit Enable the exhast fan only (See note 1) ilter alarm for both sets of filters (See note ) Bypass controls (See note 3) Control isolation dampers (See note 4) Spply fan only modlation for VD/ECM nits (See note and 6) Exhast fan only modlation for VD/ECM nits (See note and 6) Internal time clock (See note 7) Defrost controls - Canada only Smoke detection - sensor reqired (See note 8) Demand control ventilation sing CO - sensor reqired Occpancy-based ventilation - sensor reqired IQ control ventilation sing VOC - sensor reqired Microprocessor controller Provide spply and exhast air temperatres Provide otside and retrn air temperatre and hmidity an stats on both fans Enable the spply fan only Enable the exhast fan only Micro USB port ieldbs port BCnet MS/TP or BCnet TCP/IP - activation reqired Modbs Data trending Otside airflow rate Exhast airflow rate Space pressre control Dct pressre control Unit spply air temp Heating enable Heating modlation - staged or modlating Cooling modlation* - staged or modlating *RD-Series nits only Not available on EV40 E fan stats not available on EV40 þ IQ-based ERV control NOTES OR STNDRD ONLY 1. Relays and terminal block (option).. Differential pressre sensing tbe and pressre switch with manal trip point adjstment (option), wiring to switch and alarm indication provided by others. 3. Option on HE-Series (IN) and standard on RD-Series. 4. 4V transformer contactors and relays (option).. VD (option). actory installed and wired. 6. ECM (option) Potentiometer control factory wired. 7. Independent time clock (option). 8. External smoke detector (option), field installed in series to sht off nit in adverse conditions. 4
CCESSORIES STNDRD ENHNCED PREMIUM CO sensor (wall or dct mont)* IQ sensor (wall or dct mont)* Occpancy sensor (ceiling or wall mont) Smoke detector (dct mont) BCnet factory activation (MS/TP or TCP/IP) Remote display (handheld or wall mont) Room Pressre Sensor (with or withot display) Dct Static Pressre Sensor (with or withot display) NOTES *Sensor otpt is 0-10 vdc, for se as on/off or modlating control. CO IQ Wall Mont Dct Mont Wall Mont Dct Mont PRESSURE (ROOM PRESSURE/DUCT STTIC PRESSURE) OCCUPNCY Wall/Dct Mont withot Display Wall/Dct Mont with Display Ceiling Mont Wall Mont TEMPERTURE SENSOR SMOKE DETECTOR BCNET CTORY CTIVTION REMOTE DISPLY Handheld or Wall Mont Dct Mont (for nonintegrated heating) Dct Mont
INTEGRTED PROGRMMBLE POINTS LIST MODBUS/BCNET TYPE OBJECT INSTNCE VRIBLE DESCRIPTION VLUE RNGE REDWRITEMODE CONTROL MODEL naloginpt 0 O_Temp.Val Otdoor ir Temperatre XXX.Y Degrees [/C] Read_NoWrite Enhanced and Premim naloginpt 1 O_Hm.Val Otdoor ir Hmidity 0.0 to 100.0% Read_NoWrite Enhanced and Premim naloginpt R_Temp.Val Retrn ir Temperatre XXX.Y Degrees [/C] Read_NoWrite Enhanced and Premim naloginpt 3 R_Hm.Val Retrn ir Hmidity 0.0 to 100.0% Read_NoWrite Enhanced and Premim naloginpt 4 E_Temp.Val Exhast ir Temperatre XXX.Y Degrees [/C] Read_NoWrite Enhanced and Premim naloginpt S_Temp.Val resh ir rom HX Temperatre XXX.Y Degrees [/C] Read_NoWrite Enhanced and Premim naloginpt 6 O_low_Rate.Val Otdoor ir low Rate O [CM/CMH] Read_NoWrite Premim naloginpt 7 E_low_Rate.Val Exhast ir low Rate R [CM/CMH] Read_NoWrite Premim naloginpt 4 R_lt_Press.Val Retrn ir ilter Pressre XXX.YY Inches wg / Pa Read_NoWrite Enhanced and Premim naloginpt O_lt_Press.Val Otdoor ir ilter Pressre XXX.YY Inches wg / Pa Read_NoWrite Enhanced and Premim naloginpt 6 S_Command.Val Spply an Command Vale 0 to 100% Read_NoWrite Enhanced and Premim naloginpt 7 E_Command.Val Exhast an Command Vale 0 to 100% Read_NoWrite Enhanced and Premim naloginpt 8 CO_Level.Val CO Level Measrement 0 to 000 PPM Read_NoWrite Premim naloginpt 9 VOC_Level.Val VOC Level Measrement 400 to 000 PPM Read_NoWrite Premim naloginpt 30 Space_Press.Val Room Pressre Measrement XX.YYY Inch wg / Pa Read_NoWrite Premim naloginpt 31 Dct_Press.Val Dct Pressre Measrement XXX.YY Inches wg / Pa Read_NoWrite Premim naloginpt 3 Spply_Temp.Val Unit Leaving ir Temperatre Vale XXX.Y Degrees [/C] Read_NoWrite Premim naloginpt 33 Cooling_Command.Val Cooling Valve Command 0 to 100% Read_NoWrite Premim (RD only) naloginpt 34 Heating_Command.Val Heating Valve Command 0 to 100% Read_NoWrite Premim BinaryInpt 8 O_Damp.Val Otdoor ir Damper Stats 0 = Closed, 1 = Open Read_NoWrite Enhanced and Premim BinaryInpt 9 R_Damp.Val Retrn ir Damper Stats 0 = Closed, 1 = Open Read_NoWrite Enhanced and Premim BinaryInpt 14 larmmng.lrmres larm Reset Stats 0 = No Reset, 1 = Reset Read_NoWrite Enhanced and Premim BinaryInpt 1 S_Stats.Val Spply an Stats 0 = Off, 1 = On Read_NoWrite Enhanced and Premim BinaryInpt 16 E_Stats.Val Exhast an Stats 0 = Off, 1 = On Read_NoWrite Enhanced and Premim BinaryInpt 17 larm_ot.val larm Stats 0 = No larm Present, 1 = larm Present Read_NoWrite Enhanced and Premim BinaryInpt 18 Heating_Enable_1.Val Heating Stats 0 = Off, 1 = On Read_NoWrite Premim BinaryInpt 19 Cooling_Stage_1.Val Cooling Stage 1 Stats 0 = Off, 1 = On Read_NoWrite Premim (RD only) BinaryInpt 0 Cooling_Stage_.Val Cooling Stage Stats 0 = Off, 1 = On Read_NoWrite Premim (RD only) BinaryInpt 1 UnitOn Unit Stats 0 = Off, 1 = On Read_NoWrite Enhanced and Premim BinaryInpt l_spplyan.ctive Spply an larm 0 = No larm Present, 1 = larm Present Read_NoWrite Enhanced and Premim BinaryInpt 3 l_exhastan.ctive Exhast an larm 0 = No larm Present, 1 = larm Present Read_NoWrite Enhanced and Premim BinaryInpt 49 Bypass_Damp.Val Bypass Damper Stats 0 = Closed, 1 = Open Read_NoWrite Enhanced and Premim BinaryInpt 7 Heating_Enable_.Val Heating Stats 0 = Off, 1 = On Read_NoWrite Premim nalogotpt 3 R_lt_larmHigh R ilter larm Pressre Setting XXX.Y Inches wg / Pa Read_Commandable Enhanced and Premim nalogotpt 36 O_lt_larmHigh O ilter larm Pressre Setting XXX.Y Inches wg / Pa Read_Commandable Enhanced and Premim nalogotpt 37 S_ConstSpeedSetP.Val S Setpoint in Constant Speed Mode 0 to 100% Read_Commandable Enhanced and Premim nalogotpt 38 S_lowControlSetP.Val S Setpoint in low Control Mode O [CM/CMH] Read_Commandable Premim nalogotpt 39 S_DctStaticSetP.Val S Setpoint in Pressre Control Mode XXX.YY Inches wg / Pa Read_Commandable Premim nalogotpt 40 S_RoomStaticSetP.Val S Setpoint in Room Pressre Mode XXX.YY Inches wg / Pa Read_Commandable Premim nalogotpt 41 S_COSetP.Val CO Setpoint in CO Control Mode 0 to 000 PPM Read_Commandable Premim nalogotpt 4 S_VOCSetP.Val VOC Setpoint in VOC Control Mode 400 to 000 PPM Read_Commandable Premim nalogotpt 43 E_ConstSpeedSetP.Val E Setpoint in Constant Speed Mode 0 to 100% Read_Commandable Enhanced and Premim nalogotpt 44 E_lowControlSetP.Val E Setpoint in low Control Mode E [CM/CMH] Read_Commandable Premim nalogotpt 4 E_S_TrackingSetP.Val E Command in proportion to S Command 0% to 00% Read_Commandable Enhanced and Premim nalogotpt 46 E_RoomStaticSetP.Val E Setpoint in Room Pressre Mode XXX.YY Inches wg / Pa Read_Commandable Premim nalogotpt 47 CoolLockotTemp Cooling Disabled Below This Temperatre Defalt = 70 Degrees Read_Commandable Premim (RD only) nalogotpt 48 HeatLockotTemp Heating Disabled bove This Temperatre Defalt = 70 Degrees Read_Commandable Premim nalogotpt 0 Econ_Temp_Diff Temperatre Economizer Hysteresis Setting X.Y Degrees /C Read_Commandable Enhanced and Premim nalogotpt 1 Economizer.Econ_Low_Temp_Limit Economizer Lockot Temperatre XX.Y Degrees /C Read_Commandable Enhanced and Premim nalogotpt Economizer.Econ_Hysteresis Enthalpy Economizer Hysteresis Setting X.Y BTU/LB or KJ/Kg Read_Commandable Enhanced and Premim nalogotpt 3 BMS_CO_Reading CO Reading rom BMS PPM Read_Commandable Premim nalogotpt 4 BMS_Space_Press_Reading Space Pressre rom BMS (3 decimals) XX.YYY Inch wg / Pa Read_Commandable Premim nalogotpt Discharge_Temp_SetP.Val Unit Discharge Temperatre Setpoint XXX.Y Degrees [/C] Read_Commandable Premim nalogotpt 6 Room_Temp_SetP.Val Room Temperatre Setpoint XX.Y Degrees /C Read_Commandable Premim BinaryOtpt 10 OnOffUnitMng.BmsOnOff BMS enable/disable nit 0 = Off, 1 = On Read_Commandable Enhanced and Premim BinaryOtpt 11 OnOffUnitMng.BmsEfOnly Trn off S, rn E only 0 = Both ans enabled, 1 = Only E enabled Read_Commandable Enhanced and Premim BinaryOtpt 1 larmmng.lrmresbybms larm Reset Momentarily set to 1 to clear alarms Read_Commandable Enhanced and Premim BinaryOtpt 13 Tempering_Mode.Val Tempering Selection 0 = Heating, 1 = Cooling Read_Commandable Premim (RD only) NOTES 1. Read_NoWrite reports stats.. Read_Commandable reports stats and the commands an action. 6 7
CONTROL CONNECTIONS ENHNCED PREMIUM - INCLUDES EXPNSION MODULE 11 8 8 ddress Ext Bad Prot 1 3 4 6 7 8 9 10 11 1 13 14 1 with offset no offset 19. K 9.6 K 38.4 K 7.6 K CREL Modbs ON O ddress Ext. Bad Prot 6 1 KEY 1 3 4 6 Power connector Universal inpts/otpts +Vterm: terminal power spply Terminal connector/serial connection Relay digital otpts +VRE: power spply for ratiometric probes +VDC: power spply for active probes 7 8 9 10 11 1 13 14 ieldbs connector BMS connector nalog otpts Digital inpts CNbs connector Ethernet port Dip switches Micro USB port To learn more abot or controls, visit: renewaire.com Renewire.com 800.67.4499 LIT079_03 (0/18)