Overload LED On & Power LED On

Similar documents
Operating Instructions

D-TEK O P E R A T I N G I N S T R U C T I O N S V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

Operating Instructions

csw-200 intro d u c t i o n

NISSAN INTEGRATED HOMELINK TRANSMITTER

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

ELITE SERIES COMMERCIAL HIGH-TRAFFIC AC SLIDE GATE OPERATOR

For more information, please visit or call toll free at

EFC 211 Fan Control USA CAN. ... Chapter 5. Start Up and Configuration. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

Electrical Specifications

D-TEK -MS Vehicle Loop Detector. Operating Instructions

Operating Instructions

ELITE SERIES COMMERCIAL HIGH-TRAFFIC AC SWING GATE OPERATOR

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

Fault Codes and Service Programs

ENGINEERED PARKING SYSTEMS MODEL 3416D

setting up your wireless system P300W, C300W, D300W and wireless interface Standards NFS NFS EN 54-11

9 100% Recycled Paper

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

Operating Instructions

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

Full Range Systems. Mokon Troubleshooting Guide Model 311. Process/Water Loop. Problem Possible Cause Corrective Measure. Process pump will not start

PYRONIX LIMITED, Pyronix House, Braithwell Way, Hellaby Rotherham South Yorkshire S66 8QY England

RELEASE DEVICE CONTROLS

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

Model LP USER S MANUAL AND INSTALLATION INSTRUCTIONS

ELITE SERIES INDUSTRIAL AC SLIDE GATE OPERATOR

SCORPION Z16040C, Z8040C and Z5120C

GROUP OF COMPANIES. MERLIN STEALTH Electric Fence Energizer. Users Manual

5, SE GÅNGHESTER,

WARNING WARNING TROUBLESHOOTING GUIDE INTEGRATED FURNACE CONTROL MODULE

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

MAX 1500 / MAX Residential/Commercial Brushless DC Slide Gate Operators Made in USA. Quick Install Guide for. Slide Gate Operators

Installation, Operating and Maintenance Manual

Temporary wireless battery operated fire system from Channel Safety Systems

User s Manual and Warranty Information ThyssenKrupp Access

MD12-2 Vehicle Loop Detector


Ambient Weather WS-28 Indoor/Outdoor Thermometer with Daily Min/Max Display User Manual

Control Panel User Guide

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

Control Panel User Guide (TO BE RETAINED BY THE USER)

Battery Powered In-line Valve with Watering Timer RBC 7000

EW 40 Wireless Fan Control

PRODUCT DIAGRAM PACKAGE CONTENTS

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

INSTALLATION AND OPERATION INSTRUCTIONS

7-Day. Digital Thermostat. residential. & 2-cool

MAKING MODERN LIVING POSSIBLE INT INT EFIT 550. User Guide and Installation Manual. Danfoss Heating

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer)

Easy-Lam School Budget Roll Laminator

MD12-1 Vehicle Loop Detector

Pioneer-R16 Gas Monitor Operator s Manual

DRAFT INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

Functional Performance Test

SSV-DC user manual. Phason

Signature Series Auto-Sync Output Module (CC1S)

Driveway Alarm INSTALLATION MANUAL.

Wireless Occupancy Sensor, Ceiling Mount (WOS2-CM)

Universal Fan and Light Remote Control

Set. Set. Set. Set. Set. Set. Set. Sensor Pads 45 Day 90 Day 180 Day 1 Year 2 Years. Set. Set CAUTIONS

Owner s Manual TABLE OF CONTENTS

Panel Fan Series Operators Manual (Galvanized and Polymer)

Heat Pump Defrost Board Replacement Kit

User s Information Guide R2A

Intelligent Single Loop Fire Alarm Control Panel

A2Z Ozone, Inc. PRODUCT MANUAL

Safety Turtle. User Guide. Keep page 2 open when reading these operating instructions. Safety Turtle 1 User Guide

Model: GF256-A. Waffle Maker. Instruction manual

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

Panel Fan Series Operators Manual (Galvanized and Polymer)

INSTALLATION MANUAL. TOUCH Induction Cooktop

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Maintenance & Operating Instructions

9000P Wireless Alarm Owner s Manual

Model 17A00 Expansion Enclosure

MODEL ZA-8N EIGHT ZONE ANNUNCIATOR FOR ALL MONITORING APPLICATIONS OUTSTANDING FEATURES

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

ZSC100 Gas Detection and Alarm System Controller

UVS & UVE REMOTE LAMP AIR DISINFECTION SYSTEMS OWNERS GUIDE

Multilift Vertical Platform Lift OWNER S MANUAL

Troubleshooting Thermo Scientific LevelPRO Gauges

Always keep this manual in a safe readily accessible location. MODEL SERIAL SERVICE COMPANY TELEPHONE NUMBER

"Pegaso" wireless alarm system D.I.Y. wireless kit

Digital Cooking Thermometer models / 00282

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

Alarm Controller Fire and CO

600 Watt Dimmer Install Guide

Electrical rating 230V AC, 50Hz 100mA max per (maximum 35mA for originating unit with 16 Devices interconnected).

Transcription:

LED Diagnostics* The Q400 Omni Control Board provides the servicing technician a large amount of troubleshooting information through LED patterns on the board. It is normal to see the Power LED lit. The Gate Locked LED will be lit when the gate is fully open or fully closed (based on limit switch settings).

Elite LED Diagnostics P a g e 2 Overload LED On & Power LED Off Short circuit at terminals 8 and 10. Short circuit at any of the loop detectors in the board. Short circuit in the control board. Remove short circuit condition at terminals. Remove the defective loop detector. Send board for repair or replace with new board. Overload LED On & Power LED On Excessive current draw at terminal 10. Reduce accessories at terminal 10. Devices can include Over-voltage at the 120 VAC line input. Verify electrical power.

Elite LED Diagnostics P a g e 3 One limit switch is faulty (rapid flashing). Motor thermal fuse has popped-out (slowly flashing). System On LED Flashing Test the limit switches and wire connections. Reset the motor. OR Reverse Sensor LED On OR Alarm Sensor LED On Gate has encountered an obstruction during travel. Reverse sensor is extra sensitive. Remove obstruction and ensure gate path is clear. Press Stop button on control board and then either Open or Close button to cycle gate. Turn the reverse sensor counter clockwise a little more and retest.

Elite LED Diagnostics P a g e 4 There is a command hold active. Command Processed LED On This is a normal response for the operator. It does not necessarily represent a problem. Timer LED Flashing & Command Processed Flashing There is a command holding the gate open. Check inputs for command.

Elite LED Diagnostics P a g e 5 And/Or Loop detector needs to be reset. ANY Loop LED On & No Vehicle in proximity to gate Disruption in loop detector, harness, or inground wire. Frequency problems. Sensitivity problems Varies depending on detector brand. Varies depending on detector style. See onboard (plug-in) style or harness style detector troubleshooting sheet. Change the detector frequency process varies depending on detector brand. Reduce detector sensitivity process varies depending on detector brand.

Elite LED Diagnostics P a g e 6 Or Fire Dept. / Strike Open / Radio Receiver LED On 1. Input from device connected at terminals 7 & 8. Reset and test device. Devices often include fire strobes, Knox Fire Dept.: Short across terminals 7 & 8 switches, or audible emergency device (such as an SOS). 2. Remove any short found on wires connected at terminals 7 & 8. 1. Input from device connected at terminals 9 & 10. Reset and test device. Devices can include loop detector, telephone entry, stand-alone keypad/card Strike Open: Short across terminals 9 & 10 reader/radio receiver, or other opening devices. 2. Remove any short found on wires connected at terminals 9 & 10. 1. Input from device connected at terminals 11 & 12. Reset and test device. Devices generally only include stand-alone radio Radio Receiver: Short across terminals 11 & 12 receivers, but may vary depending on installing dealer. 2. Remove any short found on wires connected at terminals 11 & 12.