M 30 RE Heating only for outdoor installation with standard remote control Air heater Aeroclima STYLE 10-15 hot/cold M 50 With stainless steel frame for outdoor installation M 75 - M 100 For outdoor installation remote control as standard Model Thermal flow Code Boiler M 30 RE + n. 1 Aeroclimate STYLE 15 (heat only) Boiler M 30 RE + n. 2 Aeroclimate STYLE 10 (heat only) M50 boiler for outdoor + n. 1 Aeroclimate STYLE 15 (heat only) M75 boiler for outdoor + n. 2 Aeroclimate STYLE 15 (heat only) M100 boiler for outdoor + n. 2 Aeroclimate STYLE 15 (heat only) 32,0 32,0 51,0 75,8 97,1 30415002 30405002 30405004 30405005 30405006 4.900,00 6.160,00 8.400,00 12.023,00 13.050,00 188
Accessories Aeroclima STYLE 10-15 Code Wall-mounted electronic thermostat (with valve control complete with 4m cable) Mechanical consent thermostat for wall-mounted electronic thermostat 36205221 82,00 36205214 36,00 Basic command with summer / winter switch and manual selector of the 3 speeds 36205217 58,00 3-way valve with ON / OFF actuator complete with installation kit 36205404 180,00 Accessories for boilers M 30 RE Boiler heater for outdoor use it also acts as a splitter as the recovery of the combustion air it is positioned directly above the boiler, an attack is also provided Ø 80 Female for conveying roof fumes. INCLUDED IN THE BOILER PRICE M 30 RE 30403018 70,00 CONTAINMENT CONTAINER WALL INSTALLATION for the recessed solution, made of galvanized sheet, with bracket for positioning the thermal generator and preparing holes for flue gas discharge and combustion air passage, both on the upper side that the lateral ones complete with closing panel 30403020 170,00 Coaxial curve kit Ø 60/100 with teral 30403004 40,00 Curve 90 Ø 80 M/F 30403013 24,00 Coaxial extension Ø 60/100 M / F = 1000 mm 30403002 44,00 Extension Ø 80 M / F = 1000 mm 30403011 32,00 Smoke exhaust kit with coaxial roof Ø 60/100 30403014 170,00 External probe 30402003 64,00 Suction teral Ø 80 horizontal 30403017 20,00 45 coaxial curve M / F Ø 60/100 30403003 62,00 189
Accessories for boilers M 30 RE Codice 45 curve Ø 80 M / F 30403012 42,00 Ø 80 vertical smoke outlet teral 30403019 60,00 Installation kit 30400000 50,00 Accessories for boilers 50 M - 75 M - 100 M Remote chrono thermostat for M 50 boiler 30402006 165,00 KIT Ø 80 Air intake pipes and double exhaust fumes Ø 80 mm consisting of: - n. 2 vertical flanged air / fume connections in PP. - n. 2 multi-directional PP Ø80 90 curves M.F. with connections for air / smoke extraction - n. 2 terals in PP Ø 80 from m 1 (external air intake and wall exhaust fumes) n. 4 EPDM Ø 80 cover plates 30403088 170,00 KIT Ø 60 Air intake pipes and double fume exhaust Ø 60 mm consisting of n. 2 terals in PP Ø 60 from 1 m with cover plates Aspiration Expulsion 30403089 30403090 40,00 52,00 Flanged suction and discharge nozzles in PP Ø 80 30403091 52,00 T fitting kit (M-M-F) Ø 60 in PP with condensation drainage cap Ø 60 in PP 30403092 52,00 Reduction (M-F) Ø 80 - Ø 60 in PP 30403093 Ø 100 Curve (M-F) Ø 100 Curve in PP Ø 100 M F a 90 Curve in PP Ø 100 M F a 45 30403104 30403105 34,00 Ø 100 T fitting kit (M-M-F) Ø 100 in PP with condensation drain plug Ø 100 in PP 30403106 106,00 Ø 80 Curve 45 Curve in PP Ø 80 M F a 45 Curve in PP Ø 60 M F a 45 30403101 30403102 Ø 80 Extension M F in PP Ø 100 of 1 meter 30403103 66,00 190
Accessories for boilers 50 M - 75 M - 100 M Codice Extension Extension in PP Ø 80 mm 0,5 Extension in PP Ø 80 da 1 metro Extension in PP Ø 80 da 2 metri Extension in PP Ø 60 da 1 metro Extension in PP Ø 60 da 2 metri 30403094 30403095 30403096 30403097 30403098 40,00 40,00 80,00 40,00 52,00 Curve 90 Curve in PP Ø 80 M F a 90 Curve in PP Ø 60 M F a 90 30403199 30403100 Dimensions of the boiler M 30 RE F) 1/2 cold water inlet G) 3/4 gas R) 3/4 heating return M) 3/4 heating flow S) Condensate drain COAXIAL CONDUCT Wall teral X) distance 7 m COAXIAL CONDUCT Roof teral X) distance 8 m X X Ø 60 Ø 100 X Y SDOPPIATO LED Single, wall-mounted, rooftop chimney or suction terals Boiler M 30 RE 20 20 10 X = Maximum linear length of the flue exhaust pipe Y = Maximum linear length of the air intake duct 191 Tubo Ø 80 X Y meters All types Tubo Ø 60 Ø 80 X Y a 90 meters 1 10 Loss in linear meters per curve Ø 80 a 45 0,5 Ø 60 a 90 1,5 Ø 60 a 45 0,8
d Y Dimensions of the boiler 50 M COND SYSTEM 750 30 420 351 168 Ø 80 uscita fumi ingresso aria 200 Ø 64 85-88 65 90 100 55 90 8.8 1 2 3 4 400 420 135 1 heating flow 2) Heating return 1 3) Gas 3/4 4) Condensate drain Dimensions of the boilers 75 M - 100 M 16 495 85 224 186 110 Ø12 Ø12 880 864 1) Heating flow 1 2) Heating return 1 3) Gas 3/4 4) Condensate drain 5) Safety valve discharge 17 1 2 3 4 5 60 90 90 80 104 71 135 500 Air heater dimension STYLE 10 Air heater dimension Aeroclima STYLE 15 192
Esempi di installazione COND SYSTEM COND SYSTEM Example of COND SYSTEM installation which includes the M 30 RE condensing boiler with the combination of No. 1 Aeroclima STYLE 15 air heater for space heating. 2 1 5 3 1 Boiler M 30 RE - 2 Air heater Aeroclima STYLE 15-3 Remote control - 4 Electronic thermostat - 5 Basic control 2 1 3 4 4 Example of COND SYSTEM installation which includes the M 30 RE condensing boiler with the combination of n. 2 Aeroclima STYLE 10 air heaters for space heating. Possible directions of the fins Incorrect airflow Installation height Optimal airflow. 2,4 meters 3,5 meters 193
Technical data boiler M 30 RE DESCRIPTION CE homologation Noal heating capacity Reduced thermal power Noal heat output heating - 80-60 Noal useful power - 50-30 Useful efficiency - Useful efficiency - 50-30 Payback Return - Reduced (30 PIN) Fire loss in operation Loss in the mantle NOx emission value 80/80 mm split pipes Double conduits 60/60 mm Coaxial pipes with roof Ø 60/100 Wall-mounted coaxial ducts Ø 60/100 Mass flow rate (methane) Average flue temperature at 80-60 methane Delivery temperature Max working pressure Hot water content Natural gas pressure (G20) (GPL) G31) expansion vessel capacity Weight of empty boiler Boiler ERP data table M 30 RE DESCRIPTION Seasonal energy efficiency class of space heating Rated energetic power (Pnoal or Psup) Thermal power useful at rated thermal power in high temperature Thermal power useful at 30 of rated thermal power at low temperature Space heating - Annual energy consumption Seasonal energy efficiency of the space heating Useful efficiency at rated thermal power in high temperature Useful efficiency at 30 of noal heat output at low temperature Auxiliary electricity consumption at full load Auxiliary electricity consumption at partial load Auxiliary electricity consumption in standby mode Thermal dispersion in stand-by Emission of nitrogen oxides Daily electricity consumption Daily fuel consumption Sound power level P4 P1 ηs η4 η1 elsb el Psb Pstby NOx Qelec Qfuel U.M. 1312CM5604 ppm mt mt mt mt g/s bar l mbar l kg U.M. GJ mg/h /h /h db(a) M 30 RE 30 6 29,25-5,86 32,25-6,45 97,5-97,7 107,5-107,6 107,8 2 0,5 39, class 5 40 20 8 7 13,25 69 30-83 / 25-45 3 6 20-37 10 44 M 30 RE A 29 29,3 9,5 50 93 88,1 97,8 0,042 0,015 0,004 0,036 52 0,232 28,220 50 Tabella dati tecnici caldaia 50 M - 75 M - 100 M DESCRIPTION Reference gas Noal thermal flow Noal heat output / return flow temperature 80/60 Noal heat output / return temperature 50/30 Energetic class Minimum thermal flow Minimum thermal power Max working pressure of the boiler Number of revolutions Number of revolutions Exhaust gas flow P Exhaust gas flow P Degree of protection Power supply Temperature of fumes CO2 at noal power CO2 at imum power Total boiler capacity Empty weight U.M. bar rpm rpm Kg/h Kg/h l Kg 50 M 48,0 47,2 51,0 9,0 8,8 3,5 5600 1200 80,5 16,1 IPX5D 5 60 75 M G20 70,0 67,9 75,8 A 14,0 13,4 6,0 5500 1300 117,5 24,3 IPX4D 230V/1/50Hz 70 9,0 8,7 6 65 100 M 90,0 87,6 97,1 18,0 17,1 6,0 5500 1300 151,0 31,2 IPX4D 8 75 194
Technical data table AEROCLIMA STYLE 10-15 DESCRIPTION U.M. Thermal power water ingr. 70 (ΔT 10 C) air temperature amb. 20 Water flow Losses of load Hydraulic circuit volume Air side heat jump Thermal power water ingr. 50 (ΔT 5 C) air temperature amb. 20 Water flow Losses of load Air side heat jump Total cooling capacity water in. 7 (DT 5 ) air temperature b.s. 27, b.u. 19 (47 U.R.) Sensitive cooling power water in. 7 (DT 5 ) temp. air b.s. 27, b.u. 19 (47 U.R.) Water flow Losses of load Air flow Auxiliary speed (*) Number of fans Sound pressure (5 meters in free field with directionality factor = 2) Sound power Sound pressure auxiliary speed - (**) Power supply launching Electric power absorbed Max absorbed current Degree of protection of the fan (s) Degree of protection of the appliance OPERATING LIMITS Water temperature. To Max pressure Input air temperature Weight Kg 44 59 (*) Ventilation speeds selectable in addition to the standard ones (**) Sound pressure level at 1 meter, in free field with directionality factor 2, in the imum and imum value of the available auxiliary speeds. m 3 /h db(a) db(a) m W l/h kpa l l/h kpa l/h kpa n. / (m 3 /h) n. db(a) A kpa vel. vel. 195 STYLE 10 24,60 22,80 19,60 2116 12,3 4,0 33,5 34,1 35,9 14,90 13,80 11,90 2563 16,2 20,3 20,7 21,8 10,20 9,60 8,48 8,39 7,78 6,72 1754 9,2 2180 1980 1620 15 / (450 2200) 1 49,5 47,8 45,6 71,5 69,8 67,6 32,0 56,3 20 14 115 105 85 0,63 230V/1/50Hz IP44 IP24 3 80 800 45 STYLE 15 42,50 32,40 26,70 3655 14,1 6,0 31,5 34,9 37,2 25,80 19,60 16,20 4438 21,4 19,1 21,1 22,6 17,40 13,90 11,80 14,50 11,10 9,20 2993 11,4 4000 2750 2130 15 / (1080 4600) 2 49,6 42,3 37,7 71,6 64,3 59,7 34,8 65,3 22 15 220 200 180 1,20