RULE 225 WOOD BURNING APPLIANCES

Similar documents
RULE 417 WOOD BURNING APPLIANCES Adopted INDEX

DRAFT July 31, Any person who transfers or receives a wood burning stove or wood burning heater as part of a real property sale or transfer.

ORDINANCE NO

ARTICLE 14.A WOOD STOVES AND FIREPLACES. Standards for Solid Fuel Burning Appliances

DISTRICT/ MUNICIPALITY OF Wood Burning Appliance Bylaw No., 20

06-96 DEPARTMENT OF ENVIRONMENTAL PROTECTION CONTROL OF EMISSIONS FROM OUTDOOR WOOD BOILERS

S 2024 S T A T E O F R H O D E I S L A N D

RULE 3.23 NATURAL GAS-FIRED WATER HEATERS, SMALL BOILERS, AND PROCESS HEATERS (Adopted 10/03/2016)

TOWN OF NEWTON MANITOWOC COUNTY, WISCONSIN ORDINANCE NO AN ORDINANCE TO REGULATE SOLID FUEL-FIRED OUTDOOR HEATING DEVICES

06-96 DEPARTMENT OF ENVIRONMENTAL PROTECTION CONTROL OF EMISSIONS FROM OUTDOOR WOOD BOILERS

CITY OF PRINCE GEORGE BYLAW NO. 8266, 2010

Canada s Experiences: Thematic Session on Wood/Solid Fuel Residential Heating

Append LCCO 10.8 Emissions from Fuel-Burning Equipment

ORDINANCE CHAPTER 16 ARTICLE IV OUTDOOR WOOD FURNACES

ORDER OF THE LIEUTENANT GOVERNOR IN COUNCIL

EPA/ODEQ DEMOLITION BY FIRE REQUIREMENTS

CHAPTER 7 FIRE PREVENTION AND FIRE PROTECTION PART 1 OUTDOOR FIRES

Append LCCO 10.8 Emissions from Fuel-Burning Equipment

d. Portable water heaters used exclusively for underwater diving operations.

THE CORPORATION OF THE VILLAGE OF FRUITVALE BY-LAW NO. 749

THE GENERAL ASSEMBLY OF PENNSYLVANIA SENATE BILL

CARBON MONOXIDE ALARM STANDARDS ACT - ENACTMENT Act of Dec. 18, 2013, P.L. 1229, No. 121 Cl. 35 An Act

ANCHORAGE, ALASKA AO No (S)

326 IAC Definitions Authority: IC ; IC Affected: IC 13-12; IC ; IC

PROPOSED October 15, 2013

THE TOWN OF MIDLAND BY-LAW A By-law to regulate open air burning in the Town of Midland and to repeal By-laws and

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

VILLAGE OF TAHSIS BYLAW NO A Bylaw to Regulate Burning within the Village of Tahsis

AGENCY OF NATURAL RESOURCES Waterbury, Vermont ENVIRONMENTAL PROTECTION REGULATIONS CHAPTER 5 AIR POLLUTION CONTROL. Subchapter II.

ORDINANCE O-152. (B) Title. This ordinance shall be known as the City of Saginaw Outdoor and Open Burning Ordinance.

ORDINANCE NUMBER

REFRIGERANT PROCEDURE

ORDINANCE NO THEREFORE BE IT ORDAINED, BY THE CITY COUNCIL OF THE CITY OF BRYANT, ARKANSAS THAT:

CITY OF POWELL RIVER

AIR QUALITY CONTROL BYLAW 20170

CHAPTER 56 EXPLOSIVES AND FIREWORKS SECTION FIREWORKS 1.4G RETAIL STORAGE, DISPLAY, AND SALE

2017 WOOD BURNING DEVICE CHANGE-OUT PROGRAM GUIDELINES*

Chapter 1: General Program Information

Smoke Alarm Legislation

CITY OF PARKSVILLE. CONSOLIDATED BYLAW NO Consolidated for convenience only to include Bylaw No , , and 1428.

Residential Wood Smoke

Chapter 101 OPEN FIRES

Table of Contents. Consolidated Version, revised and verified January 24, (Original) August 21, 2017

ENERGY STAR Program Requirements Product Specification for Commercial Water Heaters. Eligibility Criteria Version 1.0: Draft 1

LexisNexis (TM) New Jersey Annotated Statutes

Consumer Fireworks in Georgia

BIRCH RUN TOWNSHIP SAGINAW COUNTY, MICHIGAN ORDINANCE # ALARM SYSTEM ORDINANCE

ORDINANCE NO The Sanitary Board of the Oro Loma Sanitary District, Alameda County, California, does ordain as follows:

TOWN OF BIGGAR OPEN OUTDOOR FIRE BYLAW BYLAW NO A BYLAW TO REGULATE OPEN OUTDOOR FIRES

TOWN OF ECKVILLE BYLAW 536/88 GARBAGE BYLAW

Brandon Fire and Emergency Services

TOWN OF CASTOR BYLAW NO. 1034

Boiler MACT Webinar Q/A

New Facilities. Minimum Requirements

MUNICIPALITY OF THE COUNTY OF KINGS

Definitions; contractors licensed by Board; examination; posting license, etc.

Chapter 16 FIRE PREVENTION AND PROTECTION* Article I. In General. Article II. Fire Department. Article III. Hazardous Material Emergencies

CHESAPEAKE LANDSCAPE ORDINANCE

Open Burning Permit Program Reference Manual

ORDINANCE NO. 527 Amendment No. 1 AN ORDINANCE ESTABLISHING TRASH REMOVAL FOR THE TOWN OF SUMMITVILLE

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

PROTECT YOURSELF AND YOUR FAMILY FROM THE SILENT KILLER IS YOURS INSTALLED?

BYLAW # SUMMER VILLAGE OF SOUTH VIEW

ORDINANCE NO

Ventilation for New Low-Rise Residential Buildings July 20, 2015

ORDINANCE NO BOARD OF SUPERVISORS, COUNTY OF SAN MATEO STATE OF CALIFORNIA

BY-LAW NUMBER OF THE CORPORATION OF THE CITY OF STRATFORD

Laboratories and Hazardous Materials. Company Overview

ORDINANCE NO

First Published in the Wichita Eagle on DELINEATED 10/02/2010 ORDINANCE NO.

Weatherization Assistance Program (WAP) Space Heater Policy

CHAPTER 20: INSTITUTIONAL USE DEVELOPMENT STANDARDS

SFA Guide to Building Regulations and Solid Fuel Heating

Agency for Health Care Administration

Under Section 608 of the CAA, EPA has established regulations (40 CFR Part 82, Subpart F) that:

WHEREAS, the City of Albany has adopted a Fire Prevention Regulations in the form of Chapter XI of the Albany Municipal Code; and

City of Moorhead Container Information

96TH GENERAL ASSEMBLY State of Illinois 2009 and 2010 SB1690

Indoor Environmental Quality

3.4 Construction Debris Waste building materials resulting from construction, remodeling, repair and demolition operations.

City of Pine Island Planning and Zoning Commission Agenda Tuesday March 12, :00 PM Second Floor City Hall 250 South Main Street

Louisville Metro Ordinance (Chapter 94: Fire Prevention) FIRE HYDRANTS, WATER MAINS AND WATER SUPPLY.

FIRE EXTINGUISHER SPACING & INSTALLATION GUIDELINES

Smoke & Carbon Monoxide

Model Carbon Monoxide (CO) Alarm Response Policy

CHAPTER House Bill No. 69

ARKANSAS FIRE PROTECTION LICENSING BOARD ACT 743 OF 1977

SOMERSWORTH CODE FIRE PREVENTION AND LIFE SAFETY CHAPTER 21

BY-LAW NO AND WHEREAS Council has, by By-law Number adopted a Forest Fire Management Plan for the Town of Bracebridge;

Quality, Design & Dependability. The Easy and Efficient Way to Heat your Home

TITLE 17 REFUSE AND TRASH DISPOSAL 1 CHAPTER 1

INDEX 100 GENERAL 101 PURPOSE 102 EXEMPTION, VACUUM CONDITION 103 EXEMPTION, VAPOR PRESSURE

BACT Determination Information

THE CORPORATION OF THE MUNICIPALITY OF GREENSTONE BY-LAW 09-48

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

TRI-LAKES MONUMENT FIRE PROTECTION DISTRICT

PURPOSE OF THE PROCEDURE

THE VILLAGE OF HAWTHORN WOODS PLUMBING CODE

A By-law to Regulate the Collection, Handling and Recycling of Waste and Recyclable Materials in Certain Premises in The City of Owen Sound

ORDINANCE NUMBER DRAFT. An ordinance amending Title 21- Subdivision and Title 22- Planning and Zoning of the

Transcription:

RULE 225 WOOD BURNING APPLIANCES Adopted 06-17-86 (Amended 10-19-93, 12-13-07) 100 GENERAL CONTENTS 101 PURPOSE 102 APPLICABILITY 103 SEVERABILITY 104 EXEMPTIONS 200 DEFINITIONS 201 APCO 202 BUILDER 203 COOKSTOVE 204 DISTRICT 205 FIREPLACE 206 GARBAGE 207 MANUFACTURER 208 MASONRY HEATER 209 MULTIPLE UNIT RESIDENTIAL DEVELOPMENT 210 NEW INSTALLATION 211 NONSEASONED WOOD 212 PELLET-FUELED WOOD BURNING HEATER 213 PERMANENTLY INOPERABLE 214 PERMANENTLY INSTALLED 215 PERSON 216 PUBLIC AREA 217 SINGLE FAMILY RESIDENTIAL STRUCTURE 218 SOLID FUEL 219 SQUAW VALLEY 220 TREATED WOOD 221 U.S. EPA 222 U.S. EPA PHASE II CERTIFIED 223 WASTE PETROLEUM PRODUCT 224 WOOD BURNING APPLIANCE 225 WOOD BURNING STOVE 300 STANDARDS 301 EMISSION STANDARDS 302 SALE AND INSTALLATION OF WOOD BURNING APPLIANCES 303 SALE OR TRANSFER OF REAL PROPERTY 304 OPERATION OF WOOD BURNING APPLIANCES 305 PROHIBITIONS 400 ADMINISTRATIVE REQUIREMENTS 401 COMPLIANCE REPORT 500 MONITORING AND RECORDS 501 TEST METHODS Placer County APCD 225-1 Rules and Regulations

This Page Intentionally Left Blank Rules and Regulations 225-2 Placer County APCD

100 GENERAL 101 PURPOSE: To limit emissions of particulate matter entering the atmosphere from the operation of a wood burning appliance. Unless otherwise specified, the requirements of this rule are effective immediately. 102 APPLICABILITY: Upon adoption, this rule will apply to: 102.1 Any person who manufactures, sells, advertises, offers for sale, supplies, or operates a permanently installed, indoor or outdoor, wood burning appliance in Placer County. 102.2 Any person who installs a wood burning appliance in any single or multiple residential development or commercial development in Placer County. 103 SEVERABILITY: If a court of competent jurisdiction issues an order that any provision of this rule is invalid, it is the intent of the Board of Directors of the District that other provisions of this rule remain in full force and affect to the extent allowed by law. 104 EXEMPTIONS 200 DEFINITIONS: 104.1 Gaseous Fuel: The provisions of this rule shall not apply to appliances that are fired exclusively with a gaseous fuel and certified to meet any of the following ANSI standards: 104.1.1 ANSI Z21.11.1 Gas-Fired Room Heaters, Vented 104.1.2 ANSI Z21.11.2 Gas-Fired Room Heaters, Un-vented 104.1.3 ANSI Z21.50 Vented Gas Fireplaces 104.1.4 ANSI Z21.86 Vented Gas-Fired Space Heating Appliances 104.1.5 ANSI Z21.88 Vented Gas Fireplace Heaters 104.2 Cook stoves: The provisions of this rule shall not apply to cook stoves. 104.3 Commercial Fire-Starting Products: The provisions of Section 305 shall not apply to commercial products manufactured expressly for starting a fire in a wood burning appliance. 104.4 Rule 202 Visible Emissions: Wood burning appliances regulated under this rule are not subject to the conditions specified in Rule 202 VISIBLE EMISSIONS. 104.5 Fireplaces: Fireplaces and other wood burning appliances that are not free standing wood stoves are exempt from the requirements of Section 303. 201 APCO: Air Pollution Control Officer. 202 BUILDER: Any individual, person, or company that constructs and/or sells any residential or commercial, single or multi-building unit with a wood burning appliance. 203 COOKSTOVE: Any wood burning appliance used primarily for cooking food as described in Title 40 of the Code of Federal Regulations (CFR) Section 60.531. 204 DISTRICT: The Placer County Air Pollution Control District. Placer County APCD 225-3 Rules and Regulations

205 FIREPLACE: Any permanently installed masonry or factory built device designed to operate with an air-to-fuel ratio greater than or equal to 35-to-1, a burn rate over 11 pounds per hour, or a weight over 1760 pounds. 206 GARBAGE: Any solid, semisolid, or liquid wastes generated from residential, commercial, and industrial sources, including but not limited to trash, refuse, rubbish, industrial wastes, asphaltic products, manure, vegetable or animal solid or semisolid wastes, and other discarded solid or semisolid wastes. 207 MANUFACTURER: Any person who constructs or imports a wood burning appliance. 208 MASONRY HEATER: Any permanently installed device that meets the definition of a masonry heater in ASTM E 1602-03. 209 MULTIPLE UNIT RESIDENTIAL DEVELOPMENT: Dwelling groups or apartments with two or more total units located on a parcel where the use specified in Section 17.04.03 of the Placer County Zoning Ordinance is allowable. 210 NEW INSTALLATION: Any indoor or outdoor wood burning appliance that is installed and is not replacing an existing wood burning appliance. New construction and structural renovations or additions, beginning on or after January 1, 2009, which include the installation of a wood burning appliance, may be classified as a new installation. 211 NONSEASONED WOOD: Wood of any species that has not been sufficiently dried and contains 20 percent or more moisture by weight. 212 PELLET-FUELED WOOD BURNING HEATER: Any wood burning heater which is operated on pellet-fuel, and is either U.S. EPA Phase II certified, or exempted under U.S. EPA requirements set forth in Title 40 CFR, Part 60, Subpart AAA, Code of Federal Regulations. 213 PERMANENTLY INOPERABLE: Modified in such a way that an appliance can no longer operate as a wood burning appliance. 214 PERMANENTLY INSTALLED: Built or installed in such a manner that the device is attached to the ground, floor, or wall, and is not readily movable. A free standing stove that is attached to an exhaust system that is built into or through a wall is considered permanently installed. 215 PERSON: Any person, firm, association, organization, partnership, business trust, corporation, company, contractor, supplier, installer, operator, user, owner, any government agency, public district, or any officer or employee thereof. 216 PUBLIC AREA: An area of a multiple unit residential development, intended for use by groups of people, including but not limited to a lounge, a restaurant, and a lobby, specifically excluding an office space, a hallway, a bedroom and other associated living areas. 217 SINGLE FAMILY RESIDENTIAL STRUCTURE: A detached building designed for or occupied by one family and located on a parcel where the uses specified in Section 17.04.030 of the Placer County Zoning Ordinance are allowable. 218 SOLID FUEL: Any wood, non-gaseous, or non-liquid fuel. Rules and Regulations 225-4 Placer County APCD

219 SQUAW VALLEY: Is defined as the area that encompasses: S28 of T16N R16E; S 2 and NE ¼ OF S29 T16N R16E; SE ¼ OF S30 T16N R16E, NE ¼ of S31 T16N and the N 2 of S32 T16N R16E; and the NW ¼ of S33 T16N R16E. 220 TREATED WOOD: Wood of any species that has been chemically impregnated, painted, coated, or similarly modified to improve resistance to insects or weathering. 221 U.S. EPA: The United States Environmental Protection Agency. 222 U.S. EPA PHASE II CERTIFIED: Any appliance certified by the U.S. EPA to meet the performance and emission standards set forth in Title 40 CFR, Part 60, Subpart AAA, Code of Federal Regulations. 223 WASTE PETROLEUM PRODUCT: Any petroleum product, other than gaseous fuels, that: 223.1 has been refined from crude oil, and 223.2 has been used, and 223.3 has been contaminated with physical or chemical impurities as a result of use. 224 WOOD BURNING APPLIANCE: Any fireplace, wood burning stove or heater, or pelletfueled wood heater, or any similar enclosed, permanently installed, indoor or outdoor device burning any solid fuel used for aesthetic or space-heating purposes, which has a heat input of less than one million British thermal units per hour (Btu/hr). 225 WOOD BURNING STOVE: An enclosed, wood burning appliance or heater capable of, and intended for space heating as described in Title 40 CFR Section 60.531 Code of Federal Regulations (i.e., wood stove or fireplace insert). 300 STANDARDS 301 EMISSION STANDARDS: Effective on the date specified in Section 302 wood burning appliances must be certified to be: 301.1 Not more than 7.5 grams per hour for a non-catalytic wood burning appliance and not more than 4.1 grams per hour for a catalytic wood burning appliance, as set forth in Title 40 CFR, Part 60, Subpart AAA or, 301.2 If a more stringent standard then is specified in Subsection 301.1 has been made effective at the time of installation by the amendment of 40 CFR, Part 60, Subpart AAA, then this more stringent certification standard must be met. 302 SALE AND INSTALLATION OF WOOD BURNING APPLIANCES: 302.1 Effective immediately upon adoption, the area known as Squaw Valley will comply with Sections 302.2.1 through 302.2.4 of this rule. 302.2 Effective January 1, 2009; 302.2.1 Any person selling, offering for sale, or installing new wood burning appliances shall distribute public awareness information with each wood burning appliance, in the form of pamphlets, brochures, or fact sheets on the following topics: Placer County APCD 225-5 Rules and Regulations

302.2.1.1 Proper installation, operation, and maintenance of the wood burning appliance, 302.2.1.2 Proper fuel selection and use, 302.2.1.3 Health effects from wood smoke, and 302.2.1.4 Weatherization methods for the home 302.2.2 No person shall sell, advertise, offer for sale, or supply, a new or used wood burning appliance unless it is one of the following: 302.2.2.1 A U.S. EPA Phase II Certified wood burning appliance, 302.2.2.2 A pellet-fueled wood burning heater, 302.2.2.3 A masonry heater, or 302.2.2.4 An appliance determined to meet the U.S. EPA particulate matter emission standard set forth in Title 40 CFR, Part 60, Subpart AAA Code of Federal Regulations, and approved in writing by the Air Pollution Control District. 302.2.3 For new installations only, of wood burning appliances, no person shall install an appliance unless it is one of the following: 302.2.3.1 A U.S. EPA Phase II Certified wood burning appliance, 302.2.3.2 A pellet-fueled wood burning heater, 302.2.3.3 A masonry heater, or 302.2.3.4 An appliance determined to meet the U.S. EPA particulate matter emission standard set forth in Title 40 CFR, Part 60, Subpart AAA Code of Federal Regulations, and approved in writing by the Air Pollution Control District. 302.2.4 For multiple unit residential developments; 302.3 Effective January 1, 2012; 302.2.4.1 Only EPA Phase II certified wood burning appliances or other allowable appliances, as specified in Subsection 302.2.3, above, may be installed, and 302.2.4.2 The appliances may only be installed in public areas. 302.3.1 No person, under any circumstances, shall install a wood burning appliance unless it is one of the following: 302.3.1.1 A U.S. EPA Phase II Certified wood burning appliance, 302.3.1.2 A pellet-fueled wood burning heater, 302.3.1.3 A masonry heater, or 302.3.1.4 An appliance determined to meet the U.S. EPA particulate matter emission standard set forth in Title 40 CFR, Part 60, Subpart AAA Code of Federal Regulations, and approved in writing by the Air Pollution Control District. Rules and Regulations 225-6 Placer County APCD

302.3.2 Except as otherwise stated in this rule, for single family residential use, a person may install and use more than one wood burning appliance as long as the total emissions from the appliances do not exceed the EPA Phase II emissions standards specified for a single non-catalytic wood burning appliance as set forth in Title 40 CFR, Part 60, Subpart AAA, Code of Federal Regulations. Pelletfueled wood burning heaters and masonry heaters are excluded from this condition. 303 SALE OR TRANSFER OF REAL PROPERTY 303.1 Effective January 1, 2012; 303.1.1 No person shall sell or transfer any real property which contains an operable free standing wood stove which is not EPA Phase II certified. 303.1.2 Prior to the sale or transfer of improved real property, the seller shall provide to the recipient of the real property, and the Placer County Air Pollution Control Officer, documentation of compliance with section 303.1.1 of this Rule. The Placer County Air Pollution Control District Board will approve a procedure to implement this Rule to become effective January 1, 2012. 303.1.3 Each property which contains a free standing wood burning stove may be subject to an inspection prior to sale or transfer by the District or other District approved agency, in order to verify compliance with this rule. 304 OPERATION OF WOOD BURNING APPLIANCES: 304.1 All wood burning appliances shall be installed and operated according to the manufacturer s specifications. No wood burning appliance shall be altered, installed, or disassembled in any way not specified by the manufacturer, or operated in any manner that could result in an additional emissions exceedance. 304.2 No person shall cause or allow readily visible smoke from a wood burning appliance to occur for a time exceeding three continuous minutes in any one hour period. Smoke created during a thirty minute start-up or shut-down period is exempt from this condition. Readily visible smoke is equated with an opacity of 20% or greater as designated by shade No. 1 on the Ringelmann Chart. 305 PROHIBITIONS: 305.1 No person shall cause or allow any of the following materials to be burned in a wood burning appliance: 305.1.1 Garbage, 305.1.2 Treated wood, 305.1.3 Plastic products, 305.1.4 Rubber products, 305.1.5 Waste petroleum products, 305.1.6 Paints and other coatings, 305.1.7 Solvents, 305.1.8 Coal, Placer County APCD 225-7 Rules and Regulations

400 ADMINISTRATIVE REQUIREMENTS: 305.1.9 Glossy or colored paper, 305.1.10 Plywood and composite wood products, 305.1.11 Non-seasoned or green wood, exceeding a 20% moisture content, 305.1.12 Any other material not intended by a manufacturer for use as fuel in a solid fuel burning device. 401 COMPLIANCE REPORT: Upon the request of the APCO, a manufacturer shall demonstrate that each wood burning appliance subject to the requirements of Section 301 meets the standards set forth in Title 40 CFR, Part 60, Subpart AAA Code of Federal Regulations. 500 MONITORING AND RECORDS 501 TEST METHODS: Compliance with the requirements of this rule shall be determined using the following test methods: 501.1 Air-to-Fuel Ratio: Air-to-fuel ratio shall be determined by EPA Test Method 28A. 501.2 Moisture Content: Moisture content of wood shall be determined by ASTM test method D4442-92. Rules and Regulations 225-8 Placer County APCD