Multi Boiler Guide. Kit #

Similar documents
USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

B-40/B-41 Modulating Temperature Controller

prestige Control Application Supplement - TriMax

prestige Control Application Supplement - ACVMax

prestige Control Application Supplement - TriMax

USER'S INFORMATION MANUAL

prestige Control Application Supplement WARNING

Control Application. Supplement - ACVMax

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

ENVI Boiler Controller

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

- Data Brochure Universal Reset Module 423

MODEL EM-10 ELECTRIC BOILER CONTROL OPERATION AND INSTRUCTION MANUAL

- Data Brochure Universal Reset Module 422

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

prestige Control Application Supplement - Type 5 MCBA WARNING

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

USER'S INFORMATION MANUAL

ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY (Corporate Sales) 85 Middle Road

ENVI Boiler Controller

- Data Brochure Boiler Control 274

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

Boiler Demand Mix 1 Demand Mix 2 Demand DHW Demand Setpoint Demand

prestige Control Application Supplement - Type 5 MCBA WARNING

Service Manual Models:

Installation & Operation Manual

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

- Essay Control Functions and Benefits

Cascade Sequencer. Control Installation and Operation Instructions. Infinite Energy Boiler Manual. Also read and follow: CS-IOM-1

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Service Manual Models:

Rev This manual covers the following models: T771. Mounting and Battery Installation

DHW / Setpoint Demand WWSD Modulation Boiler Output (x10,000 BTU/hr) External Input Signal Offset / Priority Override

- Data Brochure Boiler Control 264e

Electronic Pellet Burner Controller NPBC-V3M

Service Manual. w/con X US Interface Models: Series: & WARNING

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Parameter guide 95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER WARNING WARNING

Concert TM Boiler Control

Service Manual Models:

Heatronic 4000 IO Heatronic /04 en-us. Features. 4 boiler control, DHW, BACnet and Modbus. Installation/Operating instructions (IO)

Models CHB/CCB APPLICATION GUIDE WALL MOUNTED GAS BOILER

Service Manual Models:

Electronic Pellet Burner Controller NPBC-V3-1

Service Manual Models: Series 100 & 101

- Data Brochure Universal Reset Control 364

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

TEC Controller Multiple Compressor Heat Pump with Reversing Valve & Mixed Air Control, Application Application Note

Dual Mixing Application

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 11/10/08

ARM SERIES Switching Relays With Priority

TEC Controller Single Compressor Heat Pump with Reversing Valve Control, Application Application Note Building Technologies

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

prestige Indirect Water Heater (IDWH) Sensor Application Supplement WARNING

TEC Controller Unit Conditioner - Two-Pipe Fan Coil Cooling or Heating, Application Application Note Building Technologies

- Data Brochure Boiler Control 268

95M-200. Gas-Fired Direct Vent Modulating Hot Water Boiler. Control Manual And Troubleshooting Guide. P/N , Rev.

MG & SG SERIES BOILERS

heat interface units A BOILER WITHOUT A FLAME

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions

TEC Controller Terminal Box Controller (VAV) - with Hot Water Reheat, Application Application Note Building Technologies

The Universal Reset Control 363 is a microprocessor based control designed to maximize the comfort and efficiency provided by a hydronic

Service Manual. w/con X US Interface Models: WARNING

Installation Manual WARNING. Add-on Controller Installation Kit NPE-180A/210A/240A

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

TEC Controller Terminal Box Controller (VAV) - Series Fan Powered with Hot Water Reheat, Application Application Note

Product Manual SZ2161. Description The SZ2161 is a microprocessor-based controller designed for water source heat pump plant control applications.

AQUAS POOL PACKAGE INSTALLATION INSTRUCTIONS FOR MODELS: AP AQUAS Pool Package

TABLE B Remote Wire Connection

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

Copper-fin II/IIE Boiler and Water Heater Service Manual Models:

TEC Controller Heating & Cooling Heat Pump with Internal Reversing Valve & Mixed Air Control, Application 2072

Service Manual Models:

Project Name: Location: Engineer: Contractor: I. GENERAL

SC-3 Controller INSTALLATION AND OPERATING INSTRUCTIONS FOR GAS-FIRED, OIL FIRED AND DUAL FUEL HOT WATER HEATING PLANTS. SC-3 Applications CONTENTS

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

- Data Brochure Boiler Control 264

Instructions. Easy-wire terminal strip Microprocessor-operated. Easy remote sense. Self-checking program. Diagnostic/status LED s

Quickheat 30 weather compensated boiler control

AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252

ER65-DRW Controller. Heating Applications. Product Bulletin. Heating Controller

NURO. Boiler Controller. Advanced User s Guide NURO. Advanced User s Guide. NURO Boiler V Controller. Advanced User s Guide Rev.

- Data Brochure Addendum

Platinum Touch/Rotem One Touch

Service Manual. w/con X US Interface Models: Beginning with Serial # WARNING

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

PEERLESS PUREFIRE Installation, Operation, and Maintenance Instructions Supplement - PF-460 NOTICE. Exhaust Vent/Air Intake Size

Trinity Tft/Lx Model #s: Tft60-399/Lx Version Date:

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502*

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

Condensing Boiler RS100 Controller Training Program

Service Manual Models: 1.0, 1.3, and 1.5

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

Transcription:

Multi Boiler Guide Kit # 550002186 Technical Support @ 800-325-5479 Phone: (315) 797-1310 Fax: (866) 432-7329 e-mail: info@ecrinternational.com web site: www.ecrinternational.com Information and specifications outlined in this manual in effect at the time of printing of this manual. Manufacturer reserves the right to discontinue, change specifications or system design at any time without notice and without incurring any obligation, whatsoever. P/N 240008959, Rev. C [03/2013]

1 - Multiple Boiler Operation MULTIPLE BOILER GUIDE System Setup Boiler control can be applied for multiple boiler systems in cascade setup. System sensor input is available on low voltage terminal block to measure cascade system supply temperature. CH & DHW pump outputs are available on managing boiler. When CH supply temperature is calculated based on outdoor sensor, only one outdoor sensor is needed. Sensor is connected to managing boiler and calculates CH setpoint for cascade system. In case of cascade in combination with domestic hot water tank DHW pump can be connected to pump output of managing boiler control. Thermostat must be wired to managing boiler. Cascade boiler pump connections System configuration for handling DHW store or central heating demand. All boilers handle either DHW storage or CH heating demand at one time. Figure 1 - Typical Multiple Boiler Piping DHW Pump CH/System Pump 12"/305mm Maximum Separation System Temperature Sensor Size common piping per maximum heat capacity of entire system Limit length to 5' (1.6m) All internal primary loop ball valves closed 3/8"/10mm Open End Wrench 2

MULTIPLE BOILER GUIDE 2 - Setting Boiler Address Argus Link Connection And Power Switch S4: All boilers must be connected in parallel to Argus Link terminals on low voltage terminal block. Maximum wire length is 100' (30m) for 22 gauge, 150' (45m) for 18 gauge. Maintain polarity of wires between each boiler. Managing boiler control provides power for communication. Managing boiler S4 switch has to be in ON position (away from S4 marking). All dependent boiler S4 controls must be in OFF position (slider towards from S4 marking). NOTICE S4 switch is shipped in ON position from manufacturer. Turn OFF on all dependent boilers. Figure 2 - Control Module S4 Switch S4 Switch ON OFF 3

Figure 3 - SSC/VLT Multiple Boiler Wiring OUTDOOR SENSOR MULTIPLE BOILER GUIDE SYSTEM SENSOR UPTO16 BOILERS MANAGINGBOILER BOILER#1 DEPENDENTBOILER BOILER#2 DEPENDENTBOILER BOILER#16 Figure 4 - ECR97 Multiple Boiler Wiring 4

MULTIPLE BOILER GUIDE Menu option: Menu option found in installer display menu of each individual boiler. Press menu and enter buttons on user interface simultaneously for 5 second to enter Installer menu. See figure 5. boiler_ address Parameter Value Boiler Operation Function of system sensor input 0 (default) No cascade boiler No function 1 1st boiler (MANAGING) System sensor 2 2nd boiler (dependent) No function 3 3rd boiler (dependent) No function 4 4th boiler (dependent) No function One boiler is MANAGING (Boiler Address: 1) and all other boilers work as dependent (address 2..16). Each boiler should have its unique address. Manually program each boiler's address. 16 16th boiler (dependent) No function Once boiler is defined as dependent (addresses 2..16) display will show boiler supply temperature and boiler status. Use managing display (Boiler Address = 1) and managing boiler controls to determine demands for heat or DHW and show system temperature. Figure 5 - User Interface 5

MULTIPLE BOILER GUIDE 3 - Cascade Heating only Managing Boiler Boiler is set as Managing (address = 1), controller of this boiler will drive cascade. CH mode of managing boiler applies to all other boilers. It is only required to set CH mode on managing boiler. Outdoor temperature sensor connected to MANAGING boiler is outdoor sensor for cascade operation System sensor connected to MANAGING boiler is control sensor for cascade supply temperature. Thermostat connected to MANAGING boiler is CH heat demand input for cascade system. Managing boiler calculates required boiler setpoint to achieve requested cascade setpoint. Managing boiler provides calculated setpoint to all dependent boilers. Power of dependent boilers is Proportional Intergral Derivative (PID) controlled on basis of calculated setpoint and dependent boiler supply temperature. CH Mode Set CH mode at managing boiler. CH Setpoint For Boilers When system temperature is not high enough, setpoint for all boilers will be adjusted. Boiler setpoint will be increased when system temperature is below cascade setpoint and decreased when it is above cascade setpoint temperature. This is determined as following: PID-control loop over system temperature calculates adjustment of boiler setpoint. When system temperature is above cascade setpoint, calculated boiler setpoint will be decreased by a maximum of -10ºC (-18ºF). In case system temperature is below cascade setpoint, calculated boiler setpoint to all boilers will be increased by a maximum of 20ºC (36ºF). Calculated boiler system setpoint will be limited at 85ºC (185ºF). PID calculation does not start immediately, delay period allows system to stabilize. Delay period is calculated by multiplying Start Time delay setting with Start Modulation Delay Factor (settable). Delay period is limited to 60 minutes. Setting Start Modulation Delay to 0 disables this function. Dependent Boiler Dependent boiler (address = 2-16) always receives its setpoint from managing boiler. Firing rate of ALL boilers is PID controlled by individual boiler. Individual boiler calculated setpoint is received from managing boiler to control boiler supply temperature. Managing boiler will operate in cascade system similar to a dependent boiler, except it will also control external pumps and analyze data collected by system and outdoor sensors. Maximum dependent boiler temperature is fixed at 91ºC (196 F). 4 - Cascade Domestic Hot Water Connections: Wire external tank thermostat to DHW T-T input on managing boiler terminal block. Pump for DHW operation is connected to managing boiler DHW pump high voltage terminals. Settings: Set DHW setting, in Installer menu of managing boiler control, as follows: Set DHW mode at 2. Set DHW Boiler Assign to ALL in Installer CASCADE menu of managing boiler. Control functions as described in boiler's Installation, Operation and Maintenance Manual, when demand for DHW is detected. Dependent Boiler Dependent boilers (address =2-16) receive DHW setpoint from managing boiler. 6

MULTIPLE BOILER GUIDE 5 - Cascade Start/Stop Sequence Following sequence of operation occurs if there is call for heat (CH or DHW) boilers will start as following: Starting Boilers 1. Do not open manual gas shut off valve before purging all air from system. 2. Do not start boiler if water is leaking. Fix all leaks immediately. 3. When demand for CH is present and system temperature is below Cascade CH Setpoint - (minus) Start Boiler Differential setting, first boiler will start. 4. Managing boiler sends calculated setpoint to dependent boilers. Power of boilers is PID controlled on basis of Calculated Setpoint and Supply Temperature. 5. Managing boiler waits for 3 minutes (Default) before next boiler can start. 6. When firing rate of all boilers is 80% (Default, can be adjusted by changing Next Boiler Start Rate setting) or greater and system temperature is below Cascade CH Setpoint, next boiler starts. Start Delay Time starts over. 7. Managing boiler checks power of all operating boilers. If power of all boilers is above 80% rate and wait time has elapsed, Managing boiler starts next boiler. 8. Cycle will continue until conditions below are met. be adjusted). If system termperature is below this point no boilers are stopped. All boilers are stopped when system temperature is above Cascade Setpoint + (plus) Stop Boiler Differential. 6 - Cascade Boiler Rotation Rotation Interval setting allows user to select frequency lead boiler will be rotated. Rotation Interval=5 start sequence is as follows (x is last boiler): Days Day 0-1 Day 1-2 Day 2-3 Day 3-4 Day 4-5 Start/Stop sequence 1-2-3-4-5..x 2-3-4-5..x-1 3-4-5..x-1-2 4-5..x-1-2-3 5..x-1-2-3-5 When Rotation Interval = 0 boiler rotation is not active. If one boiler is assigned DHW demand, this boiler will always be last boiler in start/stop queue. Stopping Boilers When one boiler is below 30% (Default, can be adjusted by changing Next Boiler Stop Rate setting) last boiler is stopped. See Stop Delay Time period below. When power of one boiler is below 30% next boiler is stopped. Boilers are allowed to stop when system temperature is above Cascade Setpoint + Stop Boiler Differential (can 7

MULTIPLE BOILER GUIDE 7 - Error handling 7.1 Freeze Protection Frost protection function for cascade relates to system sensor temperature. When system sensor value is below 10 C (50 F), internal and CH pump of managing boiler start. Display shows freeze protection. When there is CH call for heat, freeze protection will be overridden and control will start for CH. Managing Boiler Once cascade freeze protection is activated managing boiler will operate as individual boiler in freeze protection mode. If boiler supply temperature drops below 5 C (41 F) burner starts at minimum firing derate and continues firing until lowest of both supply and return temperatures are above 15 C (59 F). After burner is switched off, internal and CH pumps run for post purge period. Loss Of Cascade Communication Loss of cascade communication is detected by dependent boilers. Individual boilers will show error on display when communication is lost. Boiler will go to permanent heat demand operation and use Cascade Setpoint. Set parameter per boiler. Managing boiler error When managing boiler is in error mode this boiler is not used anymore for cascade system. However dependent on error code pumps connected by managing boiler still can be controlled for cascade system. Cascade system can NOT operate with following errors: A04 - Gas valve relay error, A05 - Safety relay error E27 - Water pressure error, E31 - Low water cutoff. Dependent Boiler If supply temperature of dependent boiler drops below freeze protection function, this boiler also starts and will operate like individual boiler. 7.2 Emergency Mode Open/Shorted System Sensor When system sensor is open or shorted all boilers will go to permanent heat demand operation and use Emergensy Setpoint. Managing boiler display shows EMERGENCY MODE and system sensor error. Emergency mode is default active for each boiler, however individual boiler can be switched off via Permit Boiler Emergency Mode setting in User Menu of effected boiler. When not permitted only freeze protection is active. 8

Specific Parameters Level (Default) Value Range C F C F Permit Boiler Emergency Mode [-] 1: User yes yes/no Cascade CH Setpoint [ºC/ºF] 1: User 80 160 40..93 104..200 Boiler Address [-] 2: Installer 0 0..15 0..15 Cascade Emergency Setpoint [ºC/ºF] 2: Installer 45 113 20..65 68..149 Start Delay Time [min] 2: Installer 3 1..15 Stop Delay Time [min] 2: Installer 3 1..15 Start Boiler Diff [ºC/ºF] 2: Installer 5 9 0..20 0..36 Stop Boiler Diff [ºC/ºF] 2: Installer 2 18 0..20 0..36 Calculated setpoint Max offset down [ºC/ºF] 2: Installer 4 36 0..20 0..36 Calculated setpoint Max offset up [ºC/ºF] 2: Installer 10 18 0..20 0..36 Start Modulation Delay Factor [-] 2: Installer 5 0=disabled 1..60 Next Boiler Start Rate [%] 2: Installer 80 10..100 Next Boiler Stop Rate [%] 2: Installer 30 10..100 Rotation Interval [days] Boilers for DHW [-] MULTIPLE BOILER GUIDE 2: Installer 1 0..30 0=disabled 2: Installer all All,1..16 System Pump - Post Pump Time [sec] 2: Installer 30 seconds 1 90 Not available 9

NOTES 10

Date Service Performed Company Name & Tech Initials Company Address & Phone # 11

Technical Support @ 800-325-5479 Phone: (315) 797-1310 Fax: (866) 432-7329 e-mail: info@ecrinternational.com web site: www.ecrinternational.com Installer Information Name: Address: Phone: Email: