SUPPLEMENT TO OPERATION MANUAL Modular Air Handling Units CAIRplus ECOTWINcool

Similar documents
CAIRplus ECOTWINcool SUPPLEMENT TO OPERATION MANUAL

Product Brochure Air Handling Units with Double-Plate Heat Exchanger CAIRplus SX ECOTWIN cool. Energy efficiency through adiabatic cooling

Product Brochure Modular Air Handling Units CAIRplus. Multiflow liquid-coupled energy recovery system

We have some on stock... GEA MultiMAXX Prompt. Unit Heaters Data & Facts. GEA Heat Exchangers / HVAC Systems

PART 1 - GENERAL 1.1 WORK INCLUDED

DATA & FACTS Clean Rooms DencoHappel Air Shower. Active Air Shower for Personnel in Clean Rooms

Product brochure For a good working environment under extreme conditions Intelligent air treatment with CAIRplus Air Handling Units

WATER WITH QUALITY. Hygienic Water Treatment for Humidification Systems. Humidification and evaporative cooling

Für Compacting alle Einsatzgebiete. Raumlufttechnik. High Pressure Humidifier and Airwasher Type HPH. Power Screw Type CPS. der dischargeoffinedust

LTG High Pressure Humidifier and Airwasher

INTELLIGENT HUMIDIFICATION. Two adiabatic humidification methods intelligently combined Condair DL. Humidification and evaporative cooling

HX-30/40 and HX-30/40 S Glass and Dishwashers

EUQA Humidifier, for circulated water

APPLICATION BROCHURE Chillers and Heat Pumps Hydraulics Manual. Suggestions for the hydraulic integration of chillers and heat pumps

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

IntrCooll. Cool large buildings at 80% lower running costs

LQQA Humidifier, for circulated water

Double Intelligence Two adiabatic humidification methods intelligently combined. Humidification and Evaporative Cooling. humidity.

Humidifier CERTO. How today s room humidifiers work

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

LQQA Humidifier, for circulated water

R07. Answer any FIVE Questions All Questions carry equal marks *****

DATA & FACTS Clean Rooms CGx Air Outlet for Ceiling Installation. For Clean Air and Maximum Protection

PART 1 - GENERAL 1.1 WORK INCLUDED

Softcool evaporative cooling

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

HIGH-PRESSURE ATOMIZING SYSTEM. Humidification and adiabatic cooling. Energy efficient Reduces cooling load Multiple zone capabilities

CAIRfricostar CAU Controller with Remote Control SUPPLEMENT TO OPERATION MANUAL

OPERATION MANUAL Modular Air Handling Units CAIRplus. Solutions with Maximum Flexibility

Cool, Clean and Comfortable Nortec HP-Series. Adiabatic In-Duct High Pressure Humidification System... Simply Awesome

Getting Rid of Scale. Nortec RS Series Steam humidifier with patented scale management. Humidification and Evaporative Cooling

MELA dem Everything you need for water treatment

ORBIT WING THE BENEFITS SUMMARISED A COMPARISON. MICRO DROP duct humidifier Additional standards:

RC411 Operator Manual

Drying systems for grain and oil seeds. Schmidt-Seeger Eco Dry, Eco Cool, Eco Dry Flex.

ADVANCE TECHNOLOGIES FOR ADIABATIC COOLING AND HUMIDIFICATION Nortec Humidity, Inc. Fred Valentini Direct Room Systems Regional Manager Randall

FUNCTION DESCRIPTION. Air - Humidifier / Air - Washer

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

.4 Section Ductwork Low Pressure Metallic to 500 Pa..3 ANSI/ARI 640 Commercial and Industrial Humidifiers.

3. Before switching the equipment on, make sure that the model plate data conforms to that of the electrical and water distribution network.

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

HYGIENE AND SERVICE. The Pur water treatment system

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Armstrong Cool-Fog Systems

GEA Modular Air Handling Units. Solutions with maximum flexibility GEA CAIRéäìë. Operation Manual

CONDAIR ME. In-duct evaporative humidifier and cooler Very low energy operation. Humidification and Evaporative Cooling

High-Pressure Atomizing System

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

1.3 REFERENCES A. ANSI/NFPA 70 - National Electrical Code. B. ARI Commercial and Industrial Humidifiers.

Product Brochure Low-profile air handling units ATpicco. Modular configuration with highly efficient energy recovery

Menerga Adconair Various solutions one heat recovery system

READ AND SAVE THESE INSTRUCTIONS

AL-KO HYGRO-OPT MEMBRANE HUMIDIFIER THE NATURAL ROUTE TO AMBIENT HUMIDITY

testo Leakage detector for refrigerants Bedienungsanleitung Instruction manual

EVAPORATIVE COOLING AND HUMIDIFICATION. High-Pressure System Wetted Media System

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

Küba SF blastfreezer. High-performance air cooler for blast chilling and shock freezing

Installing the Vacuklav 40-B / 44-B

GEA Air Handling Units Modular configuration. Integrated refrigeration with optimized energy efficiency GEA CAIRplus.

Press Release. How can the efficiency of the dryer section be increased? Dryer Section All Paper Grades. Heimbach wherever paper is made.

Performance Rating of Commercial and Industrial Humidifiers

Window Kit Installation Instructions

EFFICIENT COOLING. Evaporative Cooler Condair ME. Humidification and Evaporative Cooling

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.

Equipment Layout Manual. For Cooling Towers, Evaporative Condensers & Closed Circuit Coolers

METAL FINISHING WATER CONSERVATION. Presented by Mark Gentili

PREMIUM KITCHEN MIXER TAP. PREMIUM KITCHEN MIXER TAP Assembly, operating and safety instructions IAN

BYPASS AND POWER HUMIDIFIER OWNER S MANUAL

Technical information for installation and operation

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Operating Manual. Reverse Osmosis Water Purifier. MELAdem 55

CARE & INSTRUCTION MANUAL

CONDAIR ESCO. Live steam humidifier with 100% steam tight rotary valve. Humidification and Evaporative Cooling

Series 6, Vertical Floor-Mount Units

PRESSURE FOG HIGH ATOMIZING HUMIDIFICATION SYSTEM

EqUIPMENT LAYOUT MANUAL

Evap WTW INSTALLATION INSTRUCTIONS D

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS

HE360 Humidifier Installation Kit

Chapter 5 Inspection and maintenance

GEA Air Handling Units Modular configuration. Solutions with maximum flexibility GEA CAIRplus SX. Product Brochure

READ AND SAVE THESE INSTRUCTIONS

Vapor Condensers Schwakos

Glass and Dishwashers AMX / AUX Series

INFORMATION ABOUT YOUR HUMIDIFICATION SYSTEM FOR FRUIT AND VEGETABLES DISPLAY

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

MAKE YOUR BUSINESS SMILE! PRODUCT PRESENTATION

A SYSTEM FOR HIGH-PERFORMANCE HUMIDIFICATION

Systemfilter Operation manual GB

Virtu 40 series. Coffee machine

Evaporative Cooling. HEVAC Association. Humidity Group. an alternative and supplement to mechanical cooling

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series

EN 1508 OPERATION MANUAL. Steam humidifier Condair RS. Humidification and Evaporative Cooling

AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS

Functional sections of air handling units

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

Product Brochure Unit heaters for retail and industrie MultiMAXX. Flexible, powerful, diversified

lindab we simplify construction Lindab Modular air handling units Service and maintenance manual

Transcription:

SUPPLEMENT TO OPERATION MANUAL Modular Air Handling Units CAIRplus ECOTWINcool

Table of Contents Overview of units and packaged content... 3 Adiabatic cooling... 3 Design features... 4 Fan arrangement... 4 Hood (protective hood of the air humidifier assembly)... 5 Various hood sizes... 5 Nozzle employed... 6 Solenoid valve employed... 7 Controls... 7 Maintenance... 7 Copyright note Disclosing, copying, distributing or taking any action in reliance on the contents of this document is strictly prohibited without express prior consent. Violations entail liability for any damages or other liability arising. All rights in relation to patents, utility patents or design patents are reserved. 2 PR-2013-0100-GB Subject to modifications R1-05/2016

Overview of units and packaged content Return air Exhaust air Supply air Outside air Fig. 1: Indirect adiabatic cooling with double-plate heat exchanger Adiabatic Cooling The air handling units CAIRplus for an air flow rate of 3,000 to 23,000 m³/h can be delivered ex factory with adiabatic cooling. Return air is humidified up to saturation. The coolness resulting from evaporation is then transferred to the supply air via an energy recovery system. Then the cooled supply air can be cooled down further to the desired temperature or dehumidified in the downstream cooler battery. The ECOTWINcool double-plate heat exchanger allows energy-saving adiabatic cooling with directly sprayed heat exchanger plates. The heat exchanger surfaces of the energy recovery system are also used as evaporation surface. Completely separate intake and return air flows are a prerequisite for this process. Epoxide-coated and additionally sealed heat exchangers are therefore used. In the interior, special fine atomizer nozzles humidify the return air at a pressure of 4-6 bar, so that the surfaces of the double-plate heat exchanger are uniformly wetted and operation without a booster pump is possible. Since no circulation water is used, the operation is properly hygienic. With efficiencies of up to 75 percent, very high cooling capacities are achieved based on the saturation temperature. PR-2013-0100-GB Subject to modifications R1-05/2016 3

Design features Plate-type heat exchanger Epoxy resin coating Additionally sealed foldings Tested for leaks Condensate tray for model "V" Permeate from reverse osmosis unit is corrosive The tray is therefore made of 1.4509 Humidifier segment The duct bend engages in the plate-type heat exchanger so that no water precipitates on the units walls Material 1.4509 Chamber models The humidified air does not come into contact with the ECOTWIN-V humidification chamber's internal skin Internal skin made of Aluzink or RAL9002 is sufficient the chamber must not be especially sealed. Trap A trap must be provided on site Especially for a suction return fan, a ball trap should be provided Water quality Feed water from the tap contains lime and salts which can lead to depositions. Water treatment is therefore necessary Up to a conductivity of 500µS/cm, softening is usually sufficient For higher conductivities, a reverse-osmosis unit is required Water pressure The adiabatic cooling works for water pressures of 4-6 bar, whereby a pressure of 5 to 6 bar should be aspired Fan arrangement Return fan intake Supply fan intake the ideal arrangement for plants where high leak tightness is required the ideal arrangement for plants where high pressure differentials prevail Return fan - pressure Supply fan - suction intake there is the danger of backflows, where water gets into the fan chamber. Plan sufficient clearance for plug fans. possibly employ both fans for intake Return fan intake supply fan exhausting occasionally used in plants with inferior exhaust air quality, such as kitchens this design is only practicable, however, if the system pressures are not very high the danger of leakage is not as great because of prevailing negative pressure in the damp area. be sure to pay special attention to the large differential pressure in the heat exchanger area. 4 PR-2013-0100-GB Subject to modifications R1-05/2016

Hood (protective hood of the air humidifier assembly) Hood Nozzle fitting Fig. 2: Hood The hood ensures that the humidified air or the osmosis water only remains in the heat exchanger and does not get into the rest of the air conditioning unit. Various hood sizes CAIR type Number of nozzles Nozzle pitch NW [each] Height NH [each] NH: Number of nozzles in height NW: Number of nozzles in width TH: Nozzle distribution in height TB: Nozzle distribution in width TWM:Middle nozzle distribution for two hoods Total TW [mm] TWM [mm] Height TH [mm] Interior height [mm] Interior width [mm] Number of hoods next to each other 064052 3 2 6 194 0 81 161 582.5 1 064064 3 2 6 194 0 118 236 582.5 1 064096 3 3 9 194 0 144 431 582.5 1 096052 4 2 8 226 0 81 161 902.5 1 096064 4 2 8 226 0 118 236 902.5 1 096096 4 3 12 226 0 144 431 902.5 1 128064 6 2 12 191 0 118 236 1147.5 1 128096 6 3 18 191 0 144 431 1147.5 1 128128 6 4 24 191 0 228 911 1147.5 1 160096 6 3 18 247 305 144 431 740 2 160128 8 4 32 185 243 248 991 740 2 188096 8 3 24 220 278 170 511 880 2 188128 8 4 32 220 278 248 991 880 2 220128 10 4 40 208 266 248 991 1040 2 252128 10 4 40 240 298 248 991 1200 2 PR-2013-0100-GB Subject to modifications R1-05/2016 5

Height Front view of the hood Fig. 3: Front view of a hood Height Fig. 4: Front view of two hoods Nozzle employed This is a nozzle with a ¼ inch screw thread. 1.4404 is employed as material Nozzle wrench width 12 6 PR-2013-0100-GB Subject to modifications R1-05/2016

Solenoid valve employed Suited for use in partly aggressive liquid media Material: stainless steel 1.4408 The solenoid valve is mounted by the manufacturer Connected currentless Connection ½ inch Voltage 230V IP 65 class Ambient temperature -10 to 50 C Operating pressure max. 10 bar Power 20VA Fig. 5: Solenoid valve/symbol Controls The activation of adiabatic cooling is done by opening of a solenoid valve. Requirements for activation are: Cooling demand is present The saturation temperature of the return air must lie at least 4 C below the outside temperature Partial-load operation is executed by cycling the solenoid valve. ON [sec] OFF [sec] Tab. 1: Overview of nozzle cycling Nozzle cycle Power [%] Consumption [%] 100 0 100 100 30 15 93 67 30 30 85 50 15 30 70 33 0 100 0 0 Maintenance Maintenance intervals Inspection before/after cooling season Cleaning The maintenance intervals depend on the quality of the water used. For permeate from reverse-osmosis units, the maintenance intervals can be longer than when using softened water. Generally, the units should undergo inspection before and after every cooling season. Especially check for any deposits on the plate heat exchanger as well as on the nozzle. If deposits have formed on the plate exchanger, then the function of the water treatment should be examined. Deposits on the nozzles can almost always be eliminated in an ultrasonic bath. The 3-part nozzle is previously taken apart. PR-2013-0100-GB Subject to modifications R1-05/2016 7

DencoHappel is a global company with expertise in air treatment, air conditioning and air filtration. Our nearest sales and service teams will be glad to discuss ideas and develop creative and effective solutions with you. www.dencohappel.com