Eurosmart FIN EST SLO RUS UAE Eurosmart Design & Quality Engineering GROHE Germany

Similar documents
Linear FIN EST SLO RUS UAE Lineare Design & Quality Engineering GROHE Germany

Eurosmart Cosmopolitan. Eurosmart Cosmopolitan. Design & Quality Engineering GROHE Germany /ÄM /10.11

Grohtherm 1000 Cosmopolitan. Grohtherm 1000 Cosmopolitan. Design & Quality Engineering GROHE Germany /ÄM /06.12

EUROSMART DESIGN + ENGINEERING GROHE GERMANY /ÄM /

Grohtherm 1000 Cosmopolitan. Grohtherm 1000 Cosmopolitan. Design + Engineering GROHE Germany /ÄM /01.14

Avensys Avensys FIN EST SLO RUS UAE

s y ens Av Avensys FIN EST RUS SLO RUS UAE

Avensys Avensys FIN EST SLO RUS UAE

Grohtherm Grohtherm 1000

Grohtherm Grohtherm 1000

Grohtherm Wireless! Installation Instructions Pumped High Pressure

GROHTHERM 3000 COSMOPOLITAN DESIGN + ENGINEERING GROHE GERMANY /ÄM / GB

Grohtherm Wireless! Installation Instructions Pumped

Eurodisc SE. Eurodisc SE

Vitalio System. Design + Engineering GROHE Germany /ÄM /04.14

GROHE Red Duo. Design + Engineering GROHE Germany /ÄM /04.14

RAINSHOWER SYSTEM SMARTCONTROL 360 DUO MODEL # Product Specifications. Product description

ESSENCE PROFESSIONAL PULL DOWN SINK MIXER MODEL # Product Specifications. Product description

TEMPESTA COSMOPOLITAN 100MM 4 FUNCTION HAND SHOWER MODEL # Product Specifications

Thermostatic Deck-Mounted Bathtub Mixer Installation Guide

MK 8706 / MB 8706 CONCEALED THERMOSTATIC SHOWER VALVE INSTALLATION GUIDE

Francis Pegler Memento Single Sequential Exposed Thermostatic Shower

book : T95548.FM Seite 1 Montag, Oktober 11, :01 AM

TREVI BLEND SINGLE LEVER SHOWER VALVES. INSTALLER After installation pass to user for future reference

Technical Specifications: Your product has a high quality finish and should be treated with care to preserve the visible surfaces.

RAINSHOWER SMARTCONTROL DESIGN + ENGINEERING GROHE GERMANY

Installation Instructions & Maintenance Guide 6 Refit Nuts (19) and tighten.

Parenzo Range. Basin Mixer, Bath Filler & Bath Shower Mixer. Assembly instructions

GROHE RED MONO Made in Germany

EXPRESS EASY CONTROL.

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

INSTALLATION INSTRUCTIONS

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter

Installation Instructions

Wave. BATH SHOWER MIXER MONOBLOC With Kit Deck Mounted

Decade Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Installation and converting instructions to another gas type T4530, T4650

Smile Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Thermostatic Bath Shower Mixer. Without shower kit.

Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow performance.

LD200 / RLD400 LD200-G /RLD400-G

Installation, Operating and Maintenance Guide

Installation Instructions / Warranty

Installation Instructions. Hansgrohe S 15721XXX

1/7 INSTALLATION INSTRUCTIONS. Rough Installation

MINIATURE THERMOSTATIC VALVE

Multiplex drain/overflow Visign M5. Instructions for Use from 06/2015. en_int

Artisan Thermostatic Bath Filler

INSTALLATION INSTRUCTIONS

INSTRUCTION MANUAL GAS HOB. Model:GH600

INSTALLTION FOR THERMOSTATIC VALVES

Blitz Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Installation, Operating and Maintenance Guide

Installation Instructions

BLADE BATH SHOWER MIXER DECK MOUNTED CHR WITH KIT INSTALLATION INSTRUCTIONS P BS-E A/2

INSTALLATION INSTRUCTIONS

Kiko Bath Shower Mixing Valve KK90015CP

Enzo and Enzo Deluxe Safe Touch Thermostatic Shower EN10031CP & EN10035CP

INSTALLATION AND USER MANUAL

Installation manual Washer extractor

1/7 SPOUT INSTALLATION

Floor Standing Bath Shower Mixer. Fitting instructions. Please keep these instructions for future reference and request of replacement parts.

WARNING FOR YOUR SAFETY FOR YOUR SAFETY. Outback Patio Heaters. Patio Heaters

Laundry Kit With flexi-neck faucet and storage cabinet

Installation Instructions / Warranty. Massaud

Enzo Concealed Shower Mixing Valve

INSTALLATION AND USER MANUAL

Installation Instructions / Warranty

Installation Instructions and User Guide Thermostatic Recessed Dual Control Shower Valve

TIMES SQUARE TWO-HANDLE THERMOSTAT

INSTALLATION INSTRUCTIONS

Product Description and Measurements. Thank You. Prior To Installation Steps. Waterfall Faucet Installation

Product Aftercare Guide

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

Pisa Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve. Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C,

Installation Instructions / Warranty

Installation Instructions. Starck

Installation and User Guide

Faucet Series. Installation Guide. Service Hotline Total Free (China) (America)

Cube Triplel Concealed Thermostatic Shower. Telephone Product Specification. Cleaning

Installation Instructions Flute Tap Range

BATH DRAIN. Tools Required T01-G INSTALLATION INSTRUCTIONS K-18355T/K-10164T/K-98171T K-17758T/K-45606T

X62 Tap Range. Please keep these instructions for future reference

SHOWER WATER HEATER MODEL X-SLIM 35 EC / X-SLIM 45 EC OPERATION AND INSTALLATION INSTRUCTIONS

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve with Integral Diverter

INSTALLATION INSTRUCTIONS

model DZ9030 PL SLO Downloaded from manuals search engine

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

Thermostatic Concealed Shower Valve

EcoStyle Dual Concealed Thermostatic Shower. Telephone Product Specification. Cleaning

Installation Instructions / Warranty

Plus Bath Shower Mixing Valve CP and PL30020CP

Thermostatic mixing valves with interchangeable cartridges

Inta City Concealed Shower Mixing Valve CT80010CP

INTA ION MODERN BAR / BATH SHOWER MIXER CP

Mio Concealed Shower Mixing Valve MI40010CP

Puro Mini Dual Control Shower Mixer PU90010CP

Installation Instructions Model: EB Single-Lever Lavatory Faucet

FOR INSTALLING AND USING

Transcription:

25 098 Eurosmart 25 105 D...1 I...5 N...9 GR...13 TR...17 BG...21 RO...25 GB...2 NL...6 FIN...10 CZ...14 SK...18 EST...22 CN...26 F...3 S...7 PL...11 H...15 SLO...19 LV...23 RUS...27 Eurosmart E...4 DK...8 UAE...12 P...16 HR...20 LT...24 Design & Quality Engineering GROHE Germany 99.148.131/ÄM 217798/02.12

25 098 25 105 Please pass these instructions on to the end user of the fitting! I

II

GB Application Can be used in conjunction with: Pressurised storage heaters, thermally and hydraulically controlled instantaneous heaters. Operation with low-pressure displacement water heaters is not possible. New Water Regulations This GROHE fitting with shower is equipped with single nonreturn valve. Please ensure installation complies with New Water Regulations covering backflow protection. It must also be installed in accordance with local bye-law requirements. Installation Flush piping system prior and after installation of fitting thoroughly (Consider EN 806)! Bathtub rim mounting Use mounting set to install the fitting, see fold-out page III, Fig. [1]. Refer to the dimensional drawings on fold-out page I. The cold water supply must be connected on the right and the hot water supply on the left. Open cold- and hot water supply and check connections for watertightness! Check fitting for correct function, see Fig. [2]. Function of automatic diverter (A), see Fig. [3]. Pulling the lever will release water delivery. Water will emerge from the bath outlet first. Pull diverter knob = to divert flow from bath outlet to shower outlet Flow is diverted automatically from shower outlet to bath outlet when the fitting is closed. Flow rate limiter This fitting is fitted with a flow rate limiter, permitting an infinitely individual variable reduction in the flow rate. The highest possible flow rate is set by the factory before dispatch. The use of flow rate limiters in combination with hydraulic instantaneous water heaters is not recommended. For commissioning see Replacing the cartridge point 1 to 3, Fig. [4] and [6]. Maintenance Inspect and clean all parts, replace if necessary and grease with special grease. Shut off cold and hot water supply! I. Replacing the cartridge, see fold-out page III, Fig. [4]. 1. Lever out plug (B). 2. Remove set screw (C) using a 3mm Allen key and pull off lever (D). 3. Screw off cap (E). 4. Unscrew threaded ring (F) with socket spanner 36mm. 5. Change complete cartridge (G). Specifications Minimum flow pressure 0.1 bar Maximum operating pressure 10 bar Test pressure 16 bar Assemble in reverse order. If static pressure is greater than 5 bar, fit pressure reducer. Observe the correct installation position! Avoid major pressure differences between cold and hot water supply. Flow rate at 0.1 bar flow pressure with flow straightener: approx. 11 l/min Temperature - Hot water inlet (maximum): 80 C - Recommended (energy saving): 60 C Water connection cold - right hot - left Make sure that the cartridge seals engage in the grooves on the housing. Screw in and tighten threaded ring (F). II. Diverter assembly with non-return valve, see fold-out page III, Fig. [5]. 1. Lever out cap (H). 2. With 7mm socket spanner, unscrew and remove nut (J) and diverter knob (K). 3. With 19mm open-ended spanner, remove nipple (L). 4. Pull out non-return valve (M). 5. With 12mm Allen key, remove outlet nipple (N). 6. Remove spindle (O) with spring (P). Assemble in reverse order. III. Flow straightener, see fold-out page II. Unscrew and clean flow straightener (46 164). Assemble in reverse order. Replacement parts, see fold-out page II ( * = special accessories). Care Dear Customer, We want to ensure that you get long-lasting satisfaction and pleasure from your GROHE fitting. Therefore, please read the following care instructions because damage to the surface and underlying material resulting from improper treatment is not covered by warranty. Do not use any abrasive sponges or scouring agents for cleaning. We also advise you not to use cleaning agents containing solvent or acid, limescale removers, household vinegar and cleaning agents with acetic acid in them. They are aggressive to the surface - and will leave your fitting dull and scratched. As the formulations of commercially available cleaning agents frequently change, we cannot guarantee they will provide the gentle care our fitting deserves. Clean the fitting with a little soap and a moist cloth only, then simply rinse off and wipe dry. You can avoid lime spots by drying the fitting each time it is used. If lime deposits do occur, remove them with GrohClean, our environment-friendly cleaning liquid. GrohClean is specially formulated to clean the surface of our fittings gently. GrohClean is available from your supplier. 1

1 2 30mm 30mm 3 54 D A C E 3mm 36mm B 5 7mm H J F 19mm K G L P O 6 N 12mm M 1.5mm 1.5mm III