big building site We have the product for you 1 Ventilateur Optimum

Similar documents
Venmar Ventilation inc. is North America s most important manufacturer of residential air quality equipment.

Attic Condensation. Presented by: Joan Maisonneuve Technical Services

Builder s Technical Sessions. Attic Ventilation. Presented by: Rob Kaethler. Presented in Partnership with: Insert your logo here

GUIDE TO GOOD VENTILATION

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

Good News at Home Hankey & Brown Inspection Service June 2013

Vent Supplement Ultra-80, -105, -155, -230 & -310

Section 42. Lead Paint Risk Factor NONE WATER HEATER STORAGE GAS

OFF-RIDGE VENTILATION PRODUCT BROCHURE

Bedroom 100. True or False: Space heaters are more energy efficient and inexpensive to heat large areas than central heating systems.

INSTALLATION AND SERVICE MANUAL

BUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS

BDM Direct Vent systems are for use with direct vent gas fired appliances.

CMHC HOME MAINTENANCE CHECKLIST

INSTALLATION INSTRUCTIONS TD75. Vented tumble dryer DOMESTIC. Carefully read the instructions for use before using the dryer.

INSTALLATION AND SERVICE MANUAL

Installation instructions for vented tumble dryer DOMESTIC. Dear Customer,

Innovative designs for the construction industry

Ventilation Standards

Innovative designs for the construction industry.

Innovative designs for the construction industry.

Do not use this vent pipe or fittings for venting incinerators of any kind.

ASX7-5-IOM-3 J

Back to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

VENTING VENTING OF INDIRECT GAS FIRED AND OIL FIRED HEATING APPLIANCES INDOOR GRAVITY VENTED UNIT HEATERS AND PACKAGED SYSTEMS

piping. COMBUSTION AIR CHAPTER 17

Ventilation for New Low-Rise Residential Buildings July 20, 2015

2006 Upgrade Kit FPX Wood Fireplaces

Ventis Direct Vent. Installation Instructions

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

AerFlow at ::rangehoods.com is a division of kitchen::accessories U N L I M I T E D

Inspection Checklist Mechanical Final

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

Spray Polyurethane Foam and Open-Combustion Appliances

BUILDER S PRE-INSPECTION CHECKLIST

Inspection Checklist Mechanical Rough in

Chapter FUEL GAS CODE*

SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT

Side by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions

ASX7-4-IOM-6 J

BUILDER S PRE-INSPECTION CHECKLIST

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

ce Is the Key Seasonal Home Maintenance Inspecting help keep live. help you. person to round: snow or debris. test button, which should then cause the

Direct Vent System Required

Energy problems in small apartment buildings

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Home Set-up and Maintenance. Maintenance

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

about your house Attic Venting, Attic Moisture, and Ice Dams Figure 1 Typical attic floor insulations

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Installation, Operation, and Maintenance Information

Home Maintenance Schedule

CARE & INSTRUCTION MANUAL

While most maintenance is seasonal, there are some things you should do on a frequent basis year-round:

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

101 EASY WAYS TO SAVE ENERGY AND MONEY.

Installation Instructions

INSTALLATION INSTRUCTIONS

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

Design Guide. Ecosmart Mini Duct Trunk and Outlet Design Guide for HVP50, HVP90 and HVP100 Air Handlers P/N 14013A

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

Insulating Unvented Attics With Spray Foam

Practical and Effective Approaches to Residential Ventilation for Production Builders

SAFETY AND INSTALLATION MANUAL MODEL 8100

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Use, Care, and Installation Guide

Hope Home Inspections LLC rd Ln E Sarasota, FL

101 EASY WAYS TO SAVE ENERGY AND MONEY TOGETHERWESAVE.COM

2015 MECHANICAL CODE REQUIREMENTS

PREPARED FOR: (Name of Client) CONCERNING: (Address of Property) BY: P Home. YOUR HOME CHECK 1305 FM 359, Suite G F

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

Principles of Attic Ventilation. Acomprehensive guide toplanning The BalancedSystem for attic ventilation

PelletVent Multi-fuel venting system. UL 641.

NC Mechanical Code. Land Use and Environmental Service Agency (Code Enforcement) Table of Contents

INSTALLATION AND SERVICE MANUAL

GUIDELINES FOR HIGHRISE BUILDING CONSTRUCTION PROJECTS (MECHANICAL VENTILATION)

Natural Gas Appliance Testing Action Guidelines (Non ESA/Low Income 5 )

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

VENTING GAS APPLIANCES NFPA 54 CODE

WM-4510HZD Installation Instructions

OFFICINE MINUTE VILLORBA - TREVISO

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

SILENT RANGEHOODS New Zealand s Quietest, Strongest & Most Efficient Rangehoods

2012 INTERNATIONAL FUEL GAS CODE VENTS

PROTECTING FIRE SPRINKLER SYSTEM PIPES FROM FREEZING IN CHAPTER FACILITIES

Hydronic Heating Solutions

CLe-series Dishwashers


APPUZO RANGE HOOD INSTALLATION

Building Department Informational Handout

101 Low-Cost /No-Cost. Home Energy-Saving Measures

INSTALLATION INSTRUCTIONS G2D93CT, G2D93CU, G2D95CT, & G2D95CU High Efficiency Multiposition Gas Furnace with System Sentry Control System WARNING

Hotte décorative Dekorativ emhætte Decorative Hood Dekor-Dunstabzugshaube Dekorativní odsavač Exaustor decorativo

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Heat or Energy Recovery Ventilation System

Transcription:

big building site We have the product for you 12 24 36 1 www.condor.pro

An ecological comfort whitout maintenance Optimum guarantee a first quality and reliable product. We are proud to present to our customers, CSA certified products under 252566 license. We also manufacture a full range of vent for residential, commercial, industrial and agricultural buildings. Optimum products are in galvanized steel, maintenancefree and ultra-durable with a baked paint. Our roof attic ventilator are continuously working with the wind by producing a chimney effect. Anti-gust position with deflectors design prevents infiltration regardless of bad weather or the wind direction. OP-A412 252566 www.condor.pro

Roof with limited elevation of the attic With restricted space in the attic, the air warms and humidifies quickly. To ventilate adequately, please ensure that there is no other opening than soffits and Optimum vent installed on the roof. Refer to the 1/150 standard for roofs with an angle of less than 2/12 or less than 6. OP-A412 3

Air Air Air Air Pitched roof soffits obstructed by insulation Attic vent Always ensure that soffits are kept clear to allow outside air to enter freely. Soffit and Optimum vent positioned correctly, produce a chimney effect eliminating excess heat and moisture from the attic. If soffits are blocked by insulation, use an attic vent to free them and allow sufficient air entry to ventilate properly. 4

Roof with an asymmetric slope A B 50 % 100 % It is important to leave only 50% open soffits on the short side of the roof to balance the chimney effect created naturally between the soffit and the vent. OP-A112 OP-A412 OP-A312 5

Regular shingle roof Ventilators for shingle roof produce no chimney effect. They only work by evaporation and represent a significant risk of water or snow infiltration. As soon as there is snow accumulation, they become completely covered and ineffective. The effectiveness of a Optimum ventilator is well above the ventilator for shingle roof on the market while eliminating the risk of infiltration of snow or water. It provides comfort with a cool ambiance in summer and warm in winter. OP-A412 6

Small roof attic ventilator for pitch roof The aesthetics of this vent offers all the benefits of a regular one! Due to its suitable design, it enhances the appearance and embellished the look by adapting to the frame of the booby hatch or a smaller building. The 3 fins design fits well with other vent already in place on your building. This attic roof ventilator provides the advantage of a attic cooler in summer and dry in winter. It prolongs the integrity of the structure. It promotes a suction and, with the help of wind, produces a chimney effect. The air in the attic is exchanged continuously at a frequency of 134 ft 3 /min, cover up an area of 300 ft 2. OP-A308 7

Roof provided with openings other than the soffits and ventilator You must seal any air input other than the soffits. These openings in the top of the wall adjacent to the roof, unbalance the air which must ideally enter from the bottom of the roof upwards. The air entering through these openings is immediately aspired by the ventilator, which limits the air exchange to the upper part of the roof only. 8

Regular roof vent with round base Whether to beautify your home or replacing your old turbine, a OP-T412 vent ventilation even when there is no wind. Eliminating noise and maintenance often caused by rusti by only changing the upper part of the vent. This model fits very well with the existing base. You will get excellent performance by improving the look of your home. You only have to remove the turbine, screw your Optimum instead and voila. OP-T412 9

Walls obstructing roof soffits When the wall structure reaches the roof and blocks any possible ventilation, we recommend using air inlets or special vent as RAC or RAP located on the edge of the roof. The air entering the attic will lead excess heat or humidity outwards. 10 OP-RAR OP-RAC

Mansard roof without adequate ventilation When soffits are blocked permanently, install air inlets. You can solve this problem by installing attic vents on edges of the roof. These vents are the ideal alternative to proper ventilation when the structure does not allow it. Make sure that the number of air inlets are conform to the National Building Code. OP-M96 11

Cathedral roof ventilation ducts for cathedral roof OP-C96 Ventilation ducts For a cathedral roof type, the Optimum system is essential. Its suction capacity allows a large exhaust flow of hot and wet air. Our Optimum Cathedral roofs vent is the only recommended system. Given its location, you are guaranteed a good operation at any times. An insulated duct is installed on the roof ridge length and efficiently ventilate between each truss of the roof. The aspirated air is evacuate by the Optimum vent. OP-C412 12

Roof cathedral type on trusses A cathedral type roof with trusses having an elevation of attic of 12 to 16 inches, you may install an Optimum vent on the ridge of the roof with a specific base. We must free soffits that ventilates the ridge of the roof and provide air circulation. Optimum vent ratio is 412 to 600 square feet of insulated ceiling. OP-F412 13

Ridge vent Our ridge vent is made of first quality galvanized sheet metal. It installs in length of 96 on the ridge of the roof. This system allows bleed air from the attic continuously reducing the accumulation of heat and moisture in the attic. OP-F96 14

One side cathedral type roof A B 50 % 100 % When the cathedral type roof covers only one side, it is necessary to restrict the entry of air of the open side to force a good ventilation. The vent positioned on the side A will force the air to enter through the soffits and will evacuate it outside. You may install a Optimum vent at all 600 square feet of insulated ceiling. several colors available on special order 15

Flat roofs with air inlet by parapets The positioning of the ventilators on a flat roof is of utmost importance. For flat roofs equipped with parapets air intakes : install Optimum ventilators in the center of the roof to push air circulation from parapets to the center of the roof. 16

Flat roofs without air inlet by parapets For roofs with no air intake: divide the roof by the required number of vent and install them at the center of these divisions. Depending on wind direction, a ventilator will serve as air inlet and the other will be used for evacuation. 17

Roofs with different levels 15 cm (6 ) For good performance, the fans must always be exposed to wind, so always be higher than the parapets. It is important to balance the height of vents. To optimize performance, always take the same model of ventilators on the roof. Different sized extension are sold separately. OP-P412 18

Multi Roof Exhaust Trap OP-Vent Deluxe OP-Vent The best way to manage your vents through a flat roof in a single opening. Practical and esthetic, this system minimizes air intakes and allows you to easily connect dryers, range hoods, fans, bathroom exhaust, etc, in a single unit. Optimum roof exhaust trap is designed for sloped roof OP-CT10 OP-CT6 OP-CT4 19

Coding Chart Base Type OP-A412 A - Angle Base For Sloped Roof P - Base For Flat Roof i - Isolated Base For Flat Roof R - Base With Folded Edge C - Exhaust 20 12-24 12 12-14 Number of wings 100-1 Fin 200-2 Fins 16-18 20-22 24 4 6 3 x10 12-24 12 12-14 16 300-3 Fins 400-4 Fins 500-5 Fins 600-6 Fins 700-7 Fins Base width 8 à 24 Base Width 4, 6, 10 Exhaust Exit Width 4 6 3 x10