(manual control) (ezi-slide control) INSET COAL EFFECT GAS CONVECTOR FIRE V1/100/B INSTALLATION & USER INSTRUCTIONS

Similar documents
GB IE INSTALLATION & USER INSTRUCTIONS. Model Number: V1/300/B (ez-slide control) HIGH EFFICIENCY INSET COAL EFFECT GAS CONVECTOR FIRE

ULTIMATE INSET LIVE FUEL EFFECT GAS FIRE MODEL 417 OWNER GUIDE

INSTALLATION & USER INSTRUCTIONS

OWNER GUIDE. Model 750. INSET LIVE FUEL EFFECT GAS FIRE Fitted with Harmony, Avignon or Style fascia. (GC No )

INSET LIVE FUEL EFFECT GAS FIRE

OWNER S GUIDE ETERNITY. MODEL 540C (GC No ) INSET BALANCED FLUE GAS FIRE

INSTALLER GUIDE COALFLAME & LIMOUSIN. MODEL BR627 (GC No ) INSET LIVE FUEL EFFECT GAS FIRE

INSTALLATION INSTRUCTIONS COMPACT GAS STOVE MODEL NUMBER 550

Sonnet Plus Anthem Genesis Soraya

Kalahari DECORATIVE FUEL EFFECT GAS FIRE

INSTALLATION & USER INSTRUCTIONS

Sonnet Plus Anthem Genesis Soraya

OWNER GUIDE. Anthem, Bolero, Camden, Minima, Victorian or Westminster fascia

OWNER GUIDE. Model 739 OPEN DECORATIVE GAS FIRE. (GC No )

GrateGlow THE ALL NEW CAPITAL COLLECTION. G20 at 20mbar convertible to G31 at 37mbar. For use in GB and le. Users Instructions

OWNER S GUIDE MODEL BR417 VA

Model BR660VA Heat Engine

INSTALLER AND OWNER GUIDE

OWNER GUIDE. Sunfire II Radiant. Radiant / Convector Gas Fire. Model 347 (G. C. Number )

INSTALLATION & USERS INSTRUCTIONS. FOR USE WITH NATURAL GAS 20 mbar For use in GB and IE

CRYSTAL FIRES. Inset Conventional Flue Fire. (BOSTON/MIAMI) Cf1 and MANHATTAN USER INSTALLATION AND SERVICING INSTRUCTIONS

EMBERGLOW CLASSIC RADIANT CONVECTOR GAS FIRE. Installation and Maintenance Instructions

Installation & Service Instructions

Emberglow COAL EFFECT BALANCED FLUE GAS FIRE

morsø PANTHER GAS STOVE

MODEL 466 Radiant / Convector Gas Fire Black Beauty

Plus Model BR645 VA (G.C )

ENIGMA II SLIMLINE. Owner's Manual INCLUDES USER, INSTALLATION & MAINTENANCE INSTRUCTIONS

Classic DECORATIVE FUEL EFFECT GAS FIRE. Installation, Maintenance & User Instructions

Model 341 Black Beauty Slimline

INSTALLATION AND OWNER GUIDE

COAL EFFECT BALANCED FLUE GAS FIRE

MODEL 466 Radiant / Convector Gas Fire Black Beauty

Windsor HE HIGH EFFICIENCY FUEL EFFECT GAS FIRE

Napoli BF COAL EFFECT BALANCED FLUE GAS FIRE

BLACK KNIGHT 2 - Classic Collection

Adorn, Dream, Masquerade, Excelsior, Classica, Icon or Visage

Mesina Fires GLASS FRONT VENTED Model No. M 70

ENIGMA II SLIDE CONTROL Owner's Book

Orchestra COAL EFFECT BALANCED FLUE GAS FIRE

Model 347 BLACK BEAUTY

Model 940 Inset live fuel effect gas fire

Homeflame Bauhaus, Homeflame Dream or Homeflame Harmony. (G.C. Number )

Model 741FS. Dream, Heritage or Opulent OWNER GUIDE. INSTALLER: Please leave this guide with the owner Baxi Heating U.K. Limited 2007.

Dovre 250 Cast Iron Gas Stove

INSTALLATION AND OWNER GUIDE

Model Apex Falcon, Titan & Zenit

ENIGMA HE Remote Control

INSTALLATION AND OWNER GUIDE

Full Depth Convector MC / SC

PARAGON FOCUS HE MULTI - FLUE SLIDE CONTROL

PARAGON 2000 Xtra SLIDE CONTROL Owner's Book

INSTALLER GUIDE. Model 754. INSET LIVE FUEL EFFECT GAS FIRE Fitted with. Artura fascia. (GC No )

INSTALLER S GUIDE. Model BG C-2. (GC No ) INSET LIVE FUEL EFFECT GAS FIRE. (Manufacturer ref. BR658VA)

INSTALLATION & USER INSTRUCTIONS INSET DECORATIVE GAS FIRE

Model 942 Inset live fuel effect gas fire

Model 956 OWNER GUIDE. This guide to be left with the owner INSET LIVE FUEL EFFECT GAS FIRE

Rivas Plus INSET LIVE FUEL-EFFECT GAS FIRES. Hand these instructions to the owner following installation, they must be retained for future reference.

INSTALLER GUIDE MODEL BR417 VA. (G.C ) Inset Live Fuel Effect Gas Fire with Ultimate. Front

Model 762 Inset live fuel effect gas fire

INSTALLER GUIDE. Anthem, Bolero, Camden, Minima, Victorian or Westminster fascia

PARAGON ONE REMOTE Owner's Book

INSTALLER AND OWNER GUIDE

5traxo INSTALLATION AND SERVICING INSTRUCTIONS MANDATORY REQUIREMENTS INSTALLATION

Model 941 INSET LIVE FUEL EFFECT GAS FIRE

Integra Convector Plus Manual

RADIANT / CONVECTOR GAS FIRE MODEL 426 (GC ) INSTALLATION & SERVICING INSTRUCTIONS INSTALLER: Please leave these instructions with the owner

STRATA BATTERY IGNITION RADIANT CONVECTOR GAS FIRE

Richmond Plus INSET LIVE FUEL-EFFECT GAS FIRES. Hand these instructions to the user after installation.

Owner s Manual INCLUDES. User, Maintenance, Service, and Installation Instructions Plus and 2000 Plus Extra Manual

Squirrel - Gas Stoves

GB IE. VALOR BOLERO (MODEL BR626) Inset Decorative Fuel Effect Gas Fires. For

INSTALLER AND OWNER GUIDE. Incorporating the VALOR FIRES. Adorn, Decadent, Dream, Eternal, Icon, Obsession or Visage

FULL DEPTH HE GAS FIRE

Broadway, Valor Landscape 2 Gas or Vermont fascia

Sonnet Plus Anthem Genesis Soraya

INSTALLER GUIDE. Amour, Aspect, Aspect Glass, Eclipse, Fascination, Landscape, Serenity, Tranquility or Visia

Baxi Wentworth Classic Baxi Kingston 2 Classic

Kalahari DECORATIVE FUEL EFFECT GAS FIRE

INSTALLER GUIDE. Incorporating the BAXI FIRES DIVISION. Adorn, Decadent, Dream, Eternal, Icon, Obsession or Visage

INSTALLER S GUIDE. MODEL 639 Open Decorative Gas Fire

INSTALLER AND OWNER GUIDE. Model 956 INSET MULTIFLUE GAS FIRE

INSTALLER AND OWNER GUIDE

INSTALLATION & USER INSTRUCTIONS FULL DEPTH RADIANT/CONVECTOR INSET GAS FIRE

MODEL 326 Radiant / Convector Gas Fire Sun~Fire

CRYSTAL FIRES VALENTINES BUILDING BECHERS DRIVE AINTREE RACECOURSE BUSINESS PARK LIVERPOOL MERSEYSIDE L9 5AY HEATRAVE S/L DECORATIVE INSET GAS FIRE

Model 348 Brava RADIANT / CONVECTOR GAS FIRE

Kalahari RC & Camber RC

OWNER GUIDE MODEL BR622 (GC ) INSET LIVE FUEL EFFECT GAS FIRE INCORPORATING. WITH ADORN, VISAGE, ELEGANT or ICON Front

USE & MAINTENANCE INSTRUCTIONS FOR NU-FLAME EVOLUTION PLUS GAS EFFECT FIRES (NATURAL GAS & LPG) FOR DECORATIVE PURPOSES ONLY

installation and user instructions

Model 347 Black Beauty 4 Oxysafe RADIANT / CONVECTOR GAS FIRE

PARAGON FOCUS 18 HE REMOTE

USE & MAINTENANCE INSTRUCTIONS FOR CHESNEYS ALCHEMY EVOLUTION PLUS GAS FIRES (NATURAL GAS ONLY) FOR DECORATIVE PURPOSES ONLY

NIGMA. Fuel Effect Gas Fire INSTALLATION, SERVICING AND USER INSTRUCTIONS. All instructions must be handed to the user for safekeeping

Owner s Manual INCLUDES. PARAGON 2016 & PARAGON 2016 Hi IMPORTANT

Model 347. Firelite 4 Oxysafe Regency 4 Oxysafe INSTALLER GUIDE. INSTALLER: Please leave this guide with the owner RADIANT / CONVECTOR GAS FIRE

installation and user instructions

Calibre COAL EFFECT BALANCED FLUE GAS FIRE

installation and user instructions

Transcription:

Model Number: V1/100/A V1/100/B (manual control) (ezi-slide control) INSET COAL EFFECT GAS CONVECTOR FIRE INSTALLATION & USER INSTRUCTIONS GB IE SUITABLE FOR USE ON NATURAL GAS (G20) AT 20mbar SUPPLY PRESSURE These instructions must be left with the appliance for future reference and for servicing information. The customer must be made fully aware of the appliance operational procedure before leaving this booklet with them. V1/100 Rev.3 (Sep 2012) VISION FIRES

CONTENTS TECHNICAL INFO 3 Appliance Information 3 Efficiency Information 3 Ventilation Requirements 3 INSTALLATION REQUIREMENTS 4 General Installation Conditions 4 Flue/Chimney Suitability and Inspection 4 Preparation of the Fireplace Opening 5 Fireplace Opening Size 5 Shelf Position 5 Fireguard Requirements 5 APPLIANCE INSTALLATION 6 Unpacking the Fire 6 Gas Connection 6 Preparing the Fireplace 6 Installing the Firebox 7 Fuel Bed Assembly 8 Fascia 11 Lighting the Appliance 12 Spillage Test 13 Review & Handover 13 SERVICING AND MAINTENANCE 14 Servicing 14 Removing the Burner Assembly 14 SPARES 15 USER GUIDE 16 General Information 16 Operating Procedure 17 Replacing the Battery (slide control only) 18 Ceramic Fuel Bed 18 Spillage Safety System 19 Cleaning 19 Fascia 19 2

TECHNICAL INFORMATION APPLIANCE INFORMATION This appliance should be used with Natural Gas (G20) only. Model: Gas Type Maximum Gross Input Minimum Gross Input Inlet Pressure Gas Connection Ignition V1/100/A - manual control V1/100/B - ezi-slide control G20 natural gas 6.85kW (23,400 Btu/h) 3.8kW (13,000 Btu/h) - manual control 2.9kW (9,900 Btu/h) - ezi-slide control 20mbar ±1.5mbar 8mm pipe Burner Injector Cat 82 074 Pilot Type NOx Classification 5 Piezo Electric - manual control Battery Spark - ezi-slide control Seagas P432D EFFICIENCY The efficiency of this appliance has been measured as specified in BS 7977-1 and the result is 59.7% Gross Efficiency. The gross calorific value of the fuel has been used for this efficiency calculation. The test data from which it has been calculated has been certified by B.S.I. The efficiency value may be used in the UK Government s Standard Assessment Procedure (SAP) for the energy rating of Dwellings. VENTILATION REQUIREMENTS In the UK, purpose made ventilation is not normally required for this appliance except in new build houses. However, if spillage is detected during commissioning of the appliance, this may mean there is insufficient ventilation. Additional ventilation may then be required. Please refer to any national ventilation requirements in this instance. In the ROI, it will be necessary to refer to I.S. 813 issued by the National Standards Authority of Ireland. Any air vent must not be restricted. 3

INSTALLATION REQUIREMENTS GENERAL INSTALLATION CONDITIONS In the United Kingdom it is law that all gas appliances are fitted by a competent person in accordance with the most up to date edition of the Gas Safety (Installation and Use) Regulations. Failure to install the appliance correctly could lead to prosecution. The installation must also be in accordance with all relevant parts of the Local and National Building Regulations, all relevant code of practice, and all applicable requirements of the following British Standards: BS EN 1856 Part 1 BS 715 - BS EN 1858 BS EN 1806 BS EN 1856 Part 1 BS 5440 Parts 1 & 2 BS 6461 Part 1 BS 5871 Part 2 BS 6891 Chimneys - Requirements for metal chimneys. Specification for metal flue boxes or gas fired appliances not exceeding 20kW. Chimneys - Components - Concrete flue blocks. Chimneys - Clay/ceramic flue blocks. Chimneys - Requirements for metal chimneys. Installation of Flues and Ventilation. Masonry chimneys & flues - Installation. Installation - Inset LFE gas fires. Gas pipework installation. FLUE/CHIMNEY SUITABILITY AND INSPECTION This appliance is for use with 225mm x 225mm conventional brick built chimneys and fabricated flues. Any chairbrick must be removed If the chimney has previously been used for solid fuel, the chimney must be swept before installation of the appliance. Minimum size of all flues: 125mm diameter or equivalent area. On 125mm diameter and precast flues the restrictor must be removed. Minimum effective height of all flue types: 3 metres. Single wall, twin wall or flexible flue liner must be stainless steel or aluminium and conform to BS EN 1856 Part 1. The flue system must conform to BS 5440 Part 1 in design and installation. The flue must not be used for any other appliance. Any dampers or register plates must be removed or locked in the open position. The appliance is fitted with a restrictor plate. After conducting a spillage test, if the smoke is not drawn fully into the flue, remove the restrictor plate and repeat the test. If a metal flue box (to BS 715) is used it must be totally insulated with a minimum of 50mm of suitable insulation. 4

INSTALLATION REQUIREMENTS PREPARATION OF THE FIREPLACE OPENING The appliance must be installed mounted on a non-combustible hearth. It must not be installed directly on any combustible material. The hearth must be at least 12mm thick with a periphery thickness of at least 50mm. It should be at least 700mm wide and project at least 300mm forwards from the fire opening. The appliance must be fitted into a non combustible opening. The area around the fire opening (where the appliance side and top flanges meet it) should be reasonably flat to ensure a good seal. If necessary, take appropriate measures to ensure this. The floor within the fireplace opening should be reasonably flat to ensure a good seal can be made at the bottom of the appliance. Any underfloor air supply to the fire opening must be sealed off completely. The appliance can be fitted with a non combustible fireplace surround or a proprietary fireplace surround with a temperature rating of at least 150 C. FIREPLACE OPENING SIZE When preparing the opening, please observe the following dimensions are met: WIDTH HEIGHT DEPTH MINIMUM OPENING SIZE 405mm 555mm 265mm MAXIMUM OPENING SIZE 457mm 575mm - SHELF POSITION The appliance can be installed below a combustible shelf as long as there is a minimum distance of 750mm from the top of the hearth and the shelf does not project more than 150mm. If the shelf projects more than 150mm then the distance between the top of the hearth and the shelf needs to increase by 15mm for every additional 25mm of projection beyond 150mm. FIREGUARD REQUIREMENTS A fireguard complying with BS 8423 should be fitted for the protection of children, the elderly, the infirm and pets. 5

APPLIANCE INSTALLATION UNPACKING THE FIRE Carefully remove the appliance from the carton, taking special care with any ceramic components. Remove all loose item packaging and check for all components which should include: 1 x Firebox with burner assembly 1 x Box containing ceramic components. 1 x Installation and User Instruction manual 1 x Loose parts pack including: 1 x Strip of floor sealing tape 1 x Inlet T connector 1 x Grommet for rear of firebox 4 x Woodscrews 6 x Fibre/wooden plugs 4 x Eyebolts 2 x Tension cables 2 x Cable adjusters 1 x Foam Seal 2 x Fascia fixing screws 1 x Battery (ezi-slide model only) GAS CONNECTION A concealed gas connection is recommended. If concealed pipework is required then steps must be taken to extend the supply line so that it enters the firebox through the supply hole at the bottom right hand side. The pipe should run through the supply hole and to the inlet T connector towards the front of the fire. Please ensure that the supply pipework does not encroach on the space required to fit the firebox into the fire opening. The inlet T connector features a valve for isolating the gas supply and a pressure test point. After installation, connect a suitable pressure test gauge to the pressure test point on the inlet T. With the fire lit check that the supply pressure is 20 ±1.5mbar. Disconnect the pressure gauge and check for gas soundness. PREPARING THE APPLIANCE Take the burner unit out of the fire box by removing the two screws and gently lifting away (Fig. 1). If the fire is an ezi-slide model then the slide mechanism must be disconnected first see page 14 of this manual for details. REMOVE 2 SCREWS Fit the foam seal to the rear of the firebox side and top flanges. Carefully measure and cut each piece ensuring that it is not overstretched and that there are no gaps where each piece of foam meet. A complete seal must be achieved around the three flanges. Fig. 1 6

APPLIANCE INSTALLATION INSTALLING THE FIREBOX There are two options of fixing the firebox into the fire opening/fireplace surround. Option 1 - Front Fixing Offer the firebox into the opening ensuring that the supply pipe is correctly positioned. When the firebox is in the intended position of installation make a mark through the holes indicated on Fig. 2. Carefully remove the firebox and drill and plug the fireplace where previously marked using a correctly sized masonry bit and the fibre plugs supplied. Re-position the firebox into the fireplace and secure using 4 woodscrews, tightening to seal the firebox to the fireplace. Option 2 - Cable Fixing Using Fig. 3, mark out the four positions indicated on the back of the fire opening. Drill each mark using a suitable masonry bit and fit the fibre plugs supplied. Securely screw the eye bolts into the plugs Position the firebox in front of the fire opening, allowing enough space behind the appliance for access to the fire opening and fitting of the cables. At this stage, if a concealed gas connection is required, feed the supply pipe through the hole at the bottom at the rear of the firebox. Locate the holes to the sides of the convection channel and fit the cables as shown in Fig. 4. Give the cables a sharp pull so that they grip the firebox. Thread the cables through the top eye bolts, then the bottom eyebolts, and then feed them into the holes at the bottom of the back face of the fire box (see Fig. 5). Fig. 2 Fig. 3 Fig. 4 FIXING LOCATIONS Reposition the firebox into the opening and push against the fireplace ensuring a seal against the foam strips on the rear of the firebox flanges. Fit a cable retainer over each cable and, pulling the cables taught, push the retainers into the holes that the cables run through. Tighten the screws in the cable retainers so that they clamp onto the cables. Hand turn the adjustment screws on the retainers to apply tension to the cables. 7 INITIAL CABLE RETENTION LOCATION

APPLIANCE INSTALLATION Do not over tighten the cables. Check that there are no gaps around the foam strips. Using the sealing tape supplied, create a seal between the bottom face of the firebox and the fireplace floor. Reposition the burner and secure with the two screws previously removed. Connect the supply line to the appliance. Turn on the gas supply and pressure test the pipework installation for soundness according to current standards. Fig. 5 FUEL BED ASSEMBLY Carefully unpack all of the ceramic components and position them onto the burner in the following sequence. Take the one-piece ceramic coal front and gently place it in front of the ceramic burner (factoryclamped to the burner tray). Then take the ceramic coal matrix and place it on top of the ceramic burner. Ensure that the matrix is touching the rear edges of the one-piece ceramic coal front. Fig. 6 Fig. 6 8

APPLIANCE INSTALLATION Take 5 of the large coals and position them as shown in Fig. 7 below. Fig. 7 Take 4 of the large coals and position them as shown in Fig. 8 below. Fig. 8 9

APPLIANCE INSTALLATION Take the two small coals and position them as shown in Fig. 9 below. Fig. 9 Take 3 of the large coals and position them as shown in Fig. 10 below. Fig. 10 10

APPLIANCE INSTALLATION Take the remaining two medium coals and position them as shown in Fig. 11 below. Fig. 11 Only use the coals that are supplied with this appliance. If replacement coals are required, use only a full genuine replacement set. If the appliance uses a slider control then reconnect the slider arm to the gas control pivot. FASCIA This appliance can be used with several different Vision Fires fireframes or frets. For full instructions on how to fit them please refer to the guide that is supplied with them. If the appliance uses a slide control then it is important that the adhesive control sticker (supplied with this fire) is fitted to the fascia as per instruction in the fascia fitting guide. 11

APPLIANCE INSTALLATION LIGHTING THE APPLIANCE Manual Control Open the gas isolation valve. Push the control knob and turn fully anti clockwise to the position marked P for Pilot. Hold the control knob here until the pilot lights. Hold for a further 10 seconds to allow a stable flame. Release the control knob and turn anti clockwise to the HI position to ignite the main burner. Turn the control knob clockwise to the LO position to switch the fire to its minimum heat setting. Push the control knob and turn clockwise to the P position to extinguish the main burner while leaving the pilot flame alight. Push the control knob and turn fully clockwise to the O position to extinguish the pilot flame. The appliance is now turned off. Ezi-slide Control Fit the PP9 battery (supplied) into position in the spark igniter box. Ensure that the + & - positions are aligned correctly. Open the gas isolation valve. Push the control lever fully down to the P position and hold there until the pilot lights. Hold for a further 10 seconds to allow a stable flame. Release the control lever and it will automatically raise to the LO position. The fire is now at minimum heat setting. Lift the control lever up to the HI position. You will feel a positive location check when the lever reaches this setting. Lift the control lever fully up to the O position to extinguish the pilot and main burner. The appliance is now turned off. 12

APPLIANCE INSTALLATION SPILLAGE TEST 1 Close all of the doors and window in the room of the appliance. Fig. 12 2 Ignite the appliance and set to HI position. 3 After 5 minutes hold a smoke match inside the fire (see Fig. 12. This should be positioned centrally, just underneath the convection channel at the top of the fire. In a successful installation all of the smoke should be drawn directly into the flue. If in doubt, wait a further 10 minutes and repeat the test. 4 If spillage still occurs and the flue restrictor is fitted then wait for the fire to cool, remove it and perform the spillage test again (see Fig. 13). 5 If spillage still occurs then there may be a problem with the flue. Disconnect the appliance and seek expert advice. 6 If the spillage test is successful then open all internal doors in the room. Keep all external doors and windows closed. Re-test again for spillage as instructed above. If there s an extractor fan in the vicinity of the appliance then test again with the extractor fan turned on and all interconnecting doors open. Fig. 13 REVIEW & HANDOVER Inspect the appliance and make any last minute adjustments to the ceramic positioning if required. Hand the instruction manual over to the customer and fully explain the operating procedure of the appliance. Advise the customer that they should read the User section of the manual fully before operating the appliance. Advise that there may be a slight odour during initial use and that this is normal. Inform the customer about the importance of servicing the appliance and that this should be performed by a competent person at least once a year. Point out the Warning Label to the user and ask them to read it and then remove it from the fire. 13

SERVICING & MAINTENANCE SERVICING Servicing should be carried out a least once a year by a competent person. Failure to do so will void the appliance warranty. Ensure that the fire is turned off and it is cool. The service should include a visual inspection of the chimney and fire opening for any debris. All ceramic components should be inspected and if necessary, should be replaced with a genuine full set. Check that the slots in the ceramic burner are free from soot and debris. Check that the electrode spark, pilot slot and air hole are free from soot and debris. Ensure that all ceramics components are correctly replaced as per the method in this manual. After servicing, always perform test for gas soundness and spillage. REMOVING THE BURNER ASSEMBLY Remove the fascia from the fire. For full instructions on how to do this, consult the manual that came with the fascia. Close the isolating valve in the inlet T connector and disconnect the burner. If the appliance features an ezi-slide control mechanism then disconnect the control linkage first (see Fig. 12). Fig. 12 Carefully remove the individual coals, followed by the ceramic matrix and then finally the one-piece ceramic front coals. Remove the two screws fixing the burner tray to the firebox (see Fig. 1 on page 6 For more details). Gently pull out the burner tray (including the ceramic burner. To refit the burner and ceramic components, consult pages 8-11. 14

SPARES Below you will find a list of all of the spares you may require for future service and maintenance purposes. ITEM Ceramic Coals (loose) Complete Set Ceramic Front Coal (one piece) Ceramic Matrix Ceramic Burner Brick Set Pilot Assembly Ezi-slide Slider Mechanism CODE VLS100-GL002-11D VLS100-GL002-11C VLS100-GL002-11B VLS100-GL002-11A VLS100-GL002-11E VLS100-P4-32D VLS100-GL-QK000 TECHNICAL INFORMATION 15

USER GUIDE IF YOU SMELL GAS Turn off gas supply immediately. Extinguish all flames. Do not smoke. Do not operate any electrical switches (on or off). Open doors and windows to ventilate the area. Call the Gas Emergency Service - consult your local telephone directory for information. GENERAL INFORMATION In the United Kingdom it is law that all gas appliances are fitted by a competent person in accordance with the most up to date edition of the Gas Safety (Installation and Use) Regulations. Failure to install the appliance correctly could lead to prosecution. The installation must also be in accordance with all relevant parts of the Local and National Building Regulations, all relevant code of practice, and all applicable requirements of the following British Standards. The appliance serial number can be located on the data badge which is positioned under the coal tray. If the chimney was used for solid fuel prior to installation of this appliance then it should be swept. A fireguard complying with BS 8423 should be fitted for the protection of children, the elderly, the infirm and pets. The appliance can be installed below a combustible shelf as long as there is a minimum distance of 750mm from the top of the hearth and the shelf does not project more than 150mm. If the shelf projects more than 150mm then the distance between the top of the hearth and the shelf needs to increase by 15mm for every additional 25mm of projection beyond 150mm. In the UK, purpose made ventilation is not normally required for this appliance except in new build houses. However, if spillage is detected during commissioning of the appliance, this may mean there is insufficient ventilation. Additional ventilation may then be required. In the ROI, it will be necessary to refer to I.S. 813 issued by the National Standards Authority of Ireland. Any air vent must not be restricted. 16

USER GUIDE If the appliance is fitted to a wall without a fire surround then any wall covering must be non combustible. Soft wall coverings such as wallpaper, blown vinyl are easily affected by heat and shouldn't be used unless a fire surround is fitted. Do not add extra ceramic pieces to the appliance as this can result in incorrect combustion. If any of the ceramic components become damaged then the complete ceramic set must be replaced with genuine manufacturer s parts. Do not burn paper or other materials on the appliance. Ensure that furniture and other combustible items are kept well clear of the fire. Never use aerosols or other flammable products near the fire when its in use. Always allow sufficient time after use for the fire to cool before cleaning. Servicing should be carried out a least once a year by a competent person. Failure to do so will void the appliance warranty. Please read the Servicing & Maintenance section of this manual for further information. If after installation, any home improvements are carried out such as installation of double glazing or extractor fans in adjoining rooms, etc. then a further spillage test should be carried out by a competent person. OPERATING PROCEDURE Manual Control The control knob is located behind the ash pan cover. Remove the ash pan cover to gain access. Push the control knob and turn fully anti clockwise to the position marked P for Pilot. Hold the control knob here until the pilot lights. Hold for a further 10 seconds to allow a stable flame. Release the control knob and turn anti clockwise to the HI position to ignite the main burner. Turn the control knob clockwise to the LO position to switch the fire to its minimum heat setting. Push the control knob and turn clockwise to the P position to extinguish the main burner while leaving the pilot flame alight. Push the control knob and turn fully clockwise to the O position to extinguish the pilot flame. The appliance is now turned off. 17

USER GUIDE OPERATING PROCEDURE Ezi-slide Control Open the gas isolation valve. Push the control lever fully down to the P position and hold there until the pilot lights. Hold for a further 10 seconds to allow a stable flame. Release the control lever and it will automatically raise to the LO position. The fire is now at minimum heat setting. Lift the control lever up to the HI position. You will feel a positive location check when the lever reaches this setting. Lift the control lever fully up to the O position to extinguish the pilot and main burner. The appliance is now turned off. It is recommended that for optimum efficiency the flue is primed for 20 minutes of operation. This can be achieved by running the appliance in its high (maximum heat) setting. If, for any reason, the fire extinguishes or is turned off then wait 3 minutes for the fire to cool before attempting to re ignite. REPLACING THE BATTERY (SLIDE CONTROL ONLY) The appliance requires one 9V PPS battery and is located behind the ash pan cover, under the fuel bed. If the battery needs replacing ensure that the + and - positions are aligned correctly. CERAMIC FUEL BED Cleaning of the ceramic coals and fuel bed is not recommended as they are fragile and my break. Light coatings of soot will be burnt off during normal operation of the fire. Do not expose any of the ceramic parts to water or cleaning agents. Damaged components must be replaced and can be ordered directly from the manufacturer. The address can be found on the rear page of this manual. If the ceramic components require replacing you should refer to the relevant section in this manual on pages 8-11. 18

USER GUIDE SPILLAGE SAFETY SYSTEM For safety, this appliance is fitted with an oxygen sensitive pilot system. This will cut off the gas supply to the appliance if the oxygen level in the room falls below its normal level. If this happens it usually indicates that there is a problem with the flue system. The fire must not be used and the problem corrected by a competent person. This device is not a substitute for an independently mounted carbon monoxide detector. CLEANING Ensure that the fire is cool before attempting any cleaning. Clean only the trims, fascia and metal parts. Do not clean the ceramic components. Use a lightly damp cloth to wipe away any dirt or marks from the metalwork. FASCIA This appliance can be used with several different Vision Fires fascia's or frets. For full instructions on how to fit them please refer to the guide that is supplied with them. Any fascia or fret to be used must conform to the following dimensions (Fig. 13). MINIMUM OPEN AREA OF FRET = 11,000mm² MINIMUM OPEN TOTAL OPEN AREA OF FRET & ASH PAN COVER COMBINED = 16,000mm² MAX HEIGHT 220MM Fig. 13 MINIMUM OPEN AREA OF ASH PAN COVER = 3,300mm² 19

VISION FIRES IMPERIAL POINT EXPRESS TRADING ESTATE STONE HILL ROAD FARNWORTH BOLTON BL5 9TN WWW.VISIONFIRES.CO.UK TEL: 01204 868 550