CHEF BASE CABINETS Installation, Operation and Maintenance Instructions

Similar documents
CHEF BASE CABINETS Installation, Operation and Maintenance Instructions

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions

BACK BAR REFRIGERATION Installation, Operation and Maintenance Instructions

BOTTOM MOUNT REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

BOTTOM MOUNT REFRIGERATORS & FREEZERS Installation, Operation and Maintenance Instructions

User Manual. Commercial School Milk Cooler User s Manual. Commercial School Milk Coolers: MC34, MC49, MC58

REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions

REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Refrigerators. Technical Manual and Replacement Parts List FORM NO REV H MODEL SKTTR7FW MODEL SKC1220W

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

Technical Manual and Replacement Parts List. f Real Freezers

Installation and Operation Guide For

UNDERCOUNTER LABORATORY FRONT BREATHING REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Mega Top Sandwich Prep Table Manual

Chef Base Refrigerators

Installation and Operation Guide For MCF-49FD, MCF-23FD MCR-49FD, MCR-23FD

EQUIPMENT CARE AND CLEANING

Installation & Operation Manual

SERVICE MANUAL Undercounter Refrigerator Drawer Units

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

SERIES NAV S Display Merchandisers

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

INSTRUCTIONS FOR OPERATION AND CARE OF. P.O. Box 3527 City of Industry, CA, , U.S.A

IMPORTANT PLEASE RETAIN FOR YOUR RECORDS

Preparing the Cabinet

GCG-9. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-9-N13EB G-9-N13EB GCG-9-B13EB UPRIGHT COOLER

INSTALLATION and OPERATION INSTRUCTIONS

INSTALLATION and OPERATION INSTRUCTIONS

Installation & Operation Manual

Ui REFRIGERATOR SPEC SHEET

InstructIon Manual KrEs EQuIPMEnt stands

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

PLEASE READ THIS MANUAL BEFORE USING YOUR APPLIANCE. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE.

COMMERCIAL REFRIGERATOR AND FREEZER USER S MANUAL

COUNTER TOP REFRIGERATION MODEL SERIES HUBM-2RB/HUBM-2FB/HUBM-3.5RB/HUBM-3.5FB HUBM-2R/HUBM-2F/HUBM-3.5R/HUBM-3.5F

Technical Manual and Replacement Parts List. Cream Dispenser

RPI Industries, Inc.

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

Installation & Operations Manual for. BMG-HGP Model Bottom Mounted Full-Length Swing Glass Door Refrigerator Merchandisers. 4/17 Rev.

User Manual

INSTALLATION and OPERATION INSTRUCTIONS

OWNER S MANUAL STAINLESS STEEL REACH-IN SERIES. Model: ATF1 ATF2 ATF3 ATR1 ATR2 ATR3 ATF2 ATR2

!"#$%&'(&) !(*$%"'&!$() !"#$

TABLE OF CONTENTS FOR YOUR SAFETY

ref. com Owner s Manual for models: A Step Above the Standard Thank you for choosing EVEREST

Installation & Operations Manual for R-290 SERIES. BMG-HGP Model Bottom Mounted Full-Length Swing Glass Door Refrigerator Merchandisers 2/

PLEASE READ THIS MANUAL BEFORE USING YOUR APPLIANCE. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE.

Glass Door Merchandiser Refrigerator and Freezer

BMG-HGP & BMG-SLP Model Bottom Mounted Full-Length Glass Door Refrigerator Merchandisers

Manual is for the following models: G-26 GCG-26 GCG-26-C31N* G-26-C31N* GCG-26-C231N* GCG-26-CA31N* *G,I,M,7,J plug. Instruction Manual.

Sandwich/Salad Table Under-counter Refrigerator Worktop Refrigerator

RPI Industries, Inc.

GCG-26c. Instruction Manual. G-Series Cooler

Technical Manual and Replacement Parts List. Mobile Freezer

User Manual. Commercial Chest Freezer User s Manual 360CF5, 360CF8, 360CF14, 360CF18

Solid Door Top Mount Reach-In Freezer

User Manual. Commercial Reach-In Refrigerators: RF-1D, RF-2D, RF-3D. Commercial Reach-In Freezers: FZ-1D, FZ-2D

STRUCTURE ILLUSTRATION...3 IMPORTANT SAFETY INSTRUCTIONS 4 INSTALLATION INSTRUCTION..4 OPERATING YOUR REFRIGERATOR...5-6

Wax Base Heater & Dispenser

- 1 - Updated on 18 March, 2010

Outdoor and Indoor Electric Refrigerator Model COAR

RPI Industries, Inc.

COMMERCIAL REFRIGERATOR & FREEZER SERVICE MANUAL (SCL/SCLM)

GS-1. Instruction Manual. G-Series Cooler. Manual is for the following models: GS-1-N14NF GS-1-N14NG GS-1-N14NI COUNTERTOP COOLER

Installation & Operations Manual. Master-Bilt Products 908 Highway 15 North New Albany, MS Phone: (800) REV: LN PN

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Drop-In Refrigeration System

Installation & Operations Manual Master-Bilt Products 908 Highway 15 North New Albany, MS Phone: (800)

SERIES NIM. Low Temperature Merchandisers PLEASE READ THIS MANUAL BEFORE USING THE PRODUCT

Installation and Operations Manual for HORIZONTAL DISPLAY MERCHANDISERS

Glass Door Refrigerators

Service Manual Models CPH2 & CPH3

Installation & Operations Manual. Master-Bilt Products 908 Highway 15 North New Albany, MS Phone: (800) /17 Rev.

SPR7-OS SPR601-OS SCR600L-OS SPR601-OSRC SCR600L-OSRC SP6DSSTB-OS

RCM-77. Instruction Manual. G-Series Cooler. Manual is for the following model: RCM-77-N23EB. U.S. Patent No. 8,215,125 RECHARGEABLE COLD MERCHANDISER

Operation Manual and Parts Directory

Installation & Operations Manual

Instruction Manual. Bottle Cooler. Models HBC-50 (-S) HBC-65 (-S) HBC-80 (-S) HBC-95 (-S) hoshizakiamerica.com. Issued: Revised:

- 1 - Updated on 18 March, 2010

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

REF5-BB Undercounter Blood Bank Refrigerator

INSTRUCTION MANUAL (UNIT APPEARANCE MAY VARY FROM IMAGE) BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

User Manual / Installation Instructions

Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69

Installation & Operation Manual Undercounter & Prep. table units

G-10f/GCG-10f UPRIGHT COOLER

REFRIGERATOR SAFETY. Your safety and the safety of others are very important.

INSTALLATION & OPERATING INSTRUCTIONS MODEL #17900 KEGERATOR MANUAL

11 0 Wo o d c r e s t R o a d, C h e r r y H i l l, N J For Models: VR-1, VR-2, VR-3 VF-1, VF-2, VF-3

Owners Manual Refrigerated Air Dryer MHT SERIES

Commercial Refigerator Chef Bases Service Manual Please read this manual completely before attempting to install or operate this equipment!

BLG-HGP Model Bottom Mounted Full-Length Swing Glass Door Freezer Merchandisers

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

InstructIon Manual KBP PrEP table

Transcription:

CHEF BASE CABINETS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the Bill of Lading to ensure all crates and cartons have been received. Do not sign the freight bill clear until the freight has been properly inspected for damage. All units should be inspected for damage including concealed damage by uncrating immediately. If any damage is found, it should be reported to the carrier at once, noted on the Bill of Lading and a claim should be filed with the carrier. This equipment has been inspected and tested in the manufacturing facility and has been crated in accordance with transportation rules and guidelines. The manufacturer is not responsible for freight loss or damages. INSTALLATION The exterior top of the cabinet has been protected by a plastic covering. Peel this protective covering before installation. After removing the covering, clean the interior and exterior surfaces of the unit with soap and water and a rinse with clean water. Do not use chlorinated cleaners on the surfaces as they can cause corrosion. The refrigeration system located on the side of the unit requires free air access for proper operation. Allow a minimum of seven inches between the back of the cabinet and the wall. The equipment is designed to accept heat generating cooking equipment if the equipment is properly installed with legs (supplied by the cooking equipment manufacturer). A minimum clearance of 4 inches is required between the bottom of the cooking equipment heating element and the cabinet top. Failure to provide adequate clearance voids manufacturer warranty. Installation of a heat shield (supplied by others) is recommended for optimum performance. Confirm that the proposed electrical outlet has the correct voltage, frequency and current carrying capacity for the requirements of the unit. This information is noted on the data plate on the inside left wall of the unit. The unit should be isolated on a circuit. Do not use an extension cord to get power to the unit. Improper electrical installations will void the compressor warranty. To prevent shock and fire, be sure the unit is properly grounded. The temperature controller is located inside the refrigerated compartment in the back right top corner. The default temperature is set at normal. Adjust the temperature to fit your needs. It is not recommended that the cabinet be run colder than +34 F. 1

CAUTION! DO NOT SIT OR STAND ON TOP OF THESE CABINETS AND DO NOT USE THE DRAWERS AS A STEP. SERIOUS INJURIES CAN OCCUR. Install casters per the following diagram. Note: Install casters with brakes to the front of the cabinet. MAINTENANCE General Cleaning Beginning with the initial installation, the interior surfaces of the cabinet should be periodically cleaned with a solution of warm water and baking soda. This solution will remove any odors from spillage that has occurred. The exterior of the cabinet should also be cleaned frequently with a commercial stainless steel cleaner, glass cleaner or mild soap solution. Do not use chlorinated cleaners on the stainless steel surfaces. Note: do not use stainless steel cleaners or other solvent-based chemicals on the plastic parts (door handle or trim strips) as they can cause failure. Use mild soap and warm water on plastic parts. The door gaskets should be cleaned in place with a mild soap solution to extend their life. Condenser Coil Cleaning Prior to cleaning the condenser coil disconnect the unit from power. Periodic cleaning of the condenser coil will aid the heat transfer of the refrigeration system and increase its efficiency. To accomplish this, remove the front grill from the cabinet. The condenser coil is located behind the grill. Use a soft bristled brush to remove any dirt particles that are on the fins of the condenser coil. Use a vacuum cleaner or compressed air to remove the loosened particles. Replace the grill and reconnect the unit to power. Failure to clean the condenser coil can lead to performance loss and compressor failure. It is recommended a minimum of every three months. 2

TROUBLESHOOTING Problem Remedy Compressor will not start Check the power cord and make sure it is plugged in. Check the temperature controller. If it is in the OFF position, turn it clockwise to set a desired temperature. Poor performance Move the unit from direct sunlight. Move the unit away from heating devices. Install the unit in a well ventilated place, with at least 7 inches of clearance on all sides. Clean the condenser if heavy dust is collected. Clear contents from blocking the air duct. Check the temperature controller for incorrect setting. Check the refrigerant level, it may need to be charged. Check the door and be sure it is completely closed. Unit noisy Install the unit on a level surface. Maintain 7 inches of clearance from the wall. Check for loose part or mounting. Keep the tubing free from any contact to avoid rattle. Condensation on cabinet exterior and/or floor Reduce humidity where the unit is installed. Repair or replace the gasket on the door. 3

SPECIFICATIONS * Includes 5 inches for casters. ** Above specifications are subject to change without prior notice for quality improvement. *** Relative humidity should be kept between 30% - 60%, maintaining a dew point of +50 F or less. 4

5

Chef Base Drawer Structure Small drawers Tray Frame Assy small ITEM 6 Supporter Pan A ITEM 32 Door Gasket small ITEM 13 Door Assembly- small ITEM 10 Large drawers Tray Frame Assy big ITEM 5 Supporter Pan A ITEM 32 Door Gasket big ITEM 13 Door Assembly- big ITEM 9 Chef Base Drawer Rail Structure Crossbar Rail Right ITEM 4 Cabinet Rail Right ITEM 2 Crossbar Rail Left ITEM 3 Cabinet Rail - Left ITEM 1 6

Chef Base Internal Structure Evaporator Fan Motor ITEM 29 EVAP. DUCT (3F) 1 Fan ITEM 38 2 Fan ITEM 39 3 Fan ITEM 40 EVAP. FAN GUARD Small ITEM 35 Large ITEM 36 Large ITEM 37 REF-Thermostat Kit ITEM 20 Chef Base Machine Room Disassembly REAR COVER ITEM 34 SIDE MACHINE COVER ITEM 32 EVAPORATOR Small ITEM 16 Large ITEM 17 Drain Pan(Drip) INDICATOR ITEM 27 FRONT COVER ITEM 33 Chef Base Machine Room Condensing Unit Disassembly -2 CAPILLARY & SUCTION PIPE ASSY ITEM 19 Compressor ITEM 21 - ITEM 22 Dryer ITEM 18 Condenser - ITEM 14 - ITEM 15 Unit Base E2aporating pan (dish) Hot Pipe ITEM 15 Condenser fan motor Assembly ITEM 28 HARNESS COMP Compressor Type [SD162C-L1U] ITEM 24 HARNESS MAIN ITEM 23 HARNESS COMP Compressor type [SK1A1C-L1U2] ITEM 25 7

Chef Base Wiring Diagram [CB36, CB48, CB53, CB60, CB72] Chef Base Wiring Diagram [CB84,CB96] 8