T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

Similar documents
Lo-Carbon T-series Window & Roof Models

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Lo-Carbon Quadra SELV

Lo-Carbon SELV Tempra

Lo-Carbon Quadra Centrifugal Fan

Centrif Duo & Centrif Duo Plus

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Silhouette Installation and Wiring Instructions

SUPER T WALL FANS. Installation and Wiring Instructions

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

HR200WK Through the wall Heat Recovery Ventilator

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan

Lo-Carbon Quadra Centrifugal Fan

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

VA100 SELV 12 RANGE. Installation and Wiring Instructions IPX7

Vent-Axia Svara Multifunctional app controlled fan. Important Information 2 Installation and Wiring Instructions 3-11 Accessories 12 Pin Code 12

Long Case Axial Fan. Installation and Wiring Instructions V/1/50Hz & V/3/50Hz

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

Installation and Wiring Instructions

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

Installation & Operating Instructions

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Sentinel Kinetic MVHR RANGE

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR

irconcentre.co.uk airooncentre.co.uk

Installation & Operating Instructions

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

FLUEBOOST. flueboost 350 gas fire model

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

Simply Silent Contour 4 (100mm) Axial Extraction Fan

Xpelair Simply Silent TM Contour Fan

Lo-Carbon PoziDry Pro

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter

Xpelair Simply Silent DX150

POWER SHOWERS Models 4500M 5002M 4500T 5002T

BLOW DRY & GO HAIR KIT

Lucci Designer Hi Flow Exhaust Fan

100 FLUEBOOST

CLASSIC-100. Instruction leaflet. Instruction leaflet

UBBU60LFA. Built-under Fridge Manual for Installation, Use and Maintenance IM UBBU60LFA_

PERFORMANCE SHOWER PRODUCTS

Appliance Operation Manual

nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or

GEH9026G Cooker Hood

User Manual for your GEH6017 & GEH9017 Cooker Hood

Xpelair Simply Silent TM DX100 Fan

60cm Integrated Turbo Extractor

HEAVY DUTY BRASS SHOWER PUMPS

Copperad. Copperad Fan Convectors (November 2005 onwards) Installation, Operation and Maintenance Instructions To be retained by the user

Thermostatic Concealed Shower Valve

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS

Aqua & Instantaneous Electric Shower Installation Instructions SERVICE POLICY

Blueberry Kitchen Sink Tap

EH0533 Indoor Climate Control

Cinnamon Kitchen Sink Tap

Technical data. Bathroom/shower room installations. Water services (WRAS approved)

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Glass Chimney Hood. Installation & User Instructions Please keep for future reference

IMPERIAL FIRES CAST 1 / 2 INSTRUCTIONS IMPERIAL FIRES LTD. SAXON BUSINESS PARK HANBURY ROAD STOKE PRIOR BROMSGROVE B60 4AD

air pump 2700/4500 ? 2YEAR GUARANTEE UK AIRPUMP _33435 CASC /10/ :16 Page 1

USER MANUAL. PEDESTAL FAN (16 Inch)

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER

JUNEAU JUN. 08/51193/0 Issue 0

60cm Chimney Extractor

STREAMLINE OVERSINK. Fitting Instructions and User Guide _iss_05.indd 1 15/09/ :46:30

OWNERS INSTRUCTION MANUAL

Saturn Booster PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USE AND KEEP THEM FOR FUTURE REFERENCE

Xpelair Simply Silent DX100

6000, 8000, & 15000

Chmney Hood - Model: H91PK H91PX H101PK H101PX. COOKER HOOD - User instructions

INSTANTANEOUS ELECTRIC SHOWER

Xpelair Simply Silent DX100B

Grant Spira 6-26kW and 9-36kW Wood Pellet Boilers

(SP4) SP420 (SP5) SP520 (SP9) SP920 AUS/NZ. 08/50019/5 Issue 5

DOMINATORPLUS ELECTRIC RANGE APPLIANCES INSTALLATION and SERVICING INSTRUCTIONS

This appliance has been CE-marked on the basis of compliance with the Low Voltage and EMC Directives for the voltages stated on the data plate.

WELCOME BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH

BT16.4SS-HK BT19.4SS-HK Cooker Hood

Monza Easyfit Kitchen Sink Mixer

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

Chapter 3 Cooling, heating and ventilation systems

Artisan Thermostatic Bath Filler

User Manual for your Baumatic TEL06SS Cooker Hood

9 inch and 12 inch Axial Fans Models MV230P, MV230AR and MV300AR Instructions for installation, maintenance and safe use.

BWT6.3GL Cooker Hood 60 cm Glass chimney hood

Xcell 270 Longlife DC wholehouse heat recovery unit

Ireland. Australia. New Zealand

Transcription:

T-SERIES Window & Roof Models Installation, Set-up and Operating Instructions Stock Ref. Nos. WIRED 456165A (9" WW) 456168A (9" RF) 456173A (12" WW) 456176A (12" RF) WIRELESS 456169A (9" WW) 456172A (9" RF) 456177A (12" WW) 456180A (12" RF) 230V/1/50Hz READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS READ AND SAVE THESE INSTRUCTIONS (Community Design Nos. 000112507-0001-0004 & 000112065-0001)

READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS IMPORTANT 1. THE FAN MUST BE SITED AND CONNECTED IN ACCORDANCE WITH CURRENT IEE REGULATIONS (UK) OR THE APPROPRIATE STANDARDS IN YOUR COUNTRY. 2. THIS APPLIANCE IS NOT SUITABLE FOR INSTALLATION IN A SHOWER CUBICLE OR ENCLOSURE AND MUST BE SITED AWAY FROM ANY SOURCE OF WATER SPRAY, AND MUST BE OUT OF REACH OF A PERSON USING A FIXED BATH OR SHOWER. 3. SITE AWAY FROM DIRECT SOURCES OF HEAT IN EXCESS OF 50ºC OR LESS THAN 10ºC. 4. WHEN THE FAN IS INSTALLED IN A ROOM CONTAINING A FUEL BURNING APPLIANCE, THE INSTALLER MUST ENSURE THAT AIR REPLACEMENT IS ADEQUATE FOR BOTH THE FAN AND THE FUEL BURNING APPLIANCE. 5. IF THE FAN CAN BE USED TO SUPPLY AIR INTO THE ROOM THE INSTALLER MUST ENSURE THAT THE FAN INTAKE IS LOCATED AT LEAST 600MM AWAY FROM ANY FLUE OUTLET. 6. IT IS RECOMMENDED THAT THE CONNECTION TO THE CONNECTOR SOCKET IS MADE WITH FLEXIBLE CABLE FOR EASY MAINTENANCE. 7. WIRING SHOULD BE VIA A SWITCHED SPUR WITH A 3 AMP FUSE (UK ONLY). 8. DOUBLE POLE SWITCH WITH A MINIMUM CONTACT SEPARATION OF 3MM OR PLUG AND SOCKET SHOULD BE LOCATED OUTSIDE OF A ROOM CONTAINING A FIXED BATH OR SHOWER. 9. THIS APPLIANCE MUST BE EARTHED. 10. READ THESE INSTRUCTIONS FULLY BEFORE COMMENCING INSTALLATION. 11. THE APPLIANCE IS NOT INTENDED FOR USE BY YOUNG CHILDREN OR INFIRM PERSONS WITHOUT SUPERVISION. 12. YOUNG CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE APPLIANCE. 13. A SHORT CIRCUIT OF THE AIR FLOW SHOULD ALWAYS BE AVOIDED BY SITING THE FAN AS FAR AWAY AS POSSIBLE FROM AND OPPOSITE TO THE MAIN SOURCE OF AIR REPLACEMENT. B1/ 2 B1/ 2 Fig. 1 SPEED CONTROLLER CONNECTION SOCKET (WIRED VERSION ONLY) POWER SUPPLY/ RECEIVER UNIT CONNECTOR SOCKET MOTOR BODY HOUSING HOUSING INDOOR GRILLE ROOF COWL SHUTTER ACTUATOR IMPELLER BASE OUTER GRILLE SECTION 2

FAN DIMENSIONS Before commencing work, study the tables shown in figures C1/ C2 to ensure fan will fit in position proposed. NB: Allow a minimum of 54mm above fan casing for withdrawal of connector socket. Please note that for all Roof Fan installations a suitable sealing compound must be used to seal the exterior roof cowl assembly to the glass/or roof plate, to ensure a weatherproof seal. D1 THICKNESS OF GLASS Fans can be fitted in most types of glass and fixing thickness up to 32mm, with the screws provided. When fixing thickness exceeds 32mm, the unit should be secured with Extended Fixing Rods. If the unit is to be installed in a location exposed to severe wind turbulence or in non-vertical panes, thicker glass will be required consult your nearest Vent-Axia Sales, Service and Distribution Centre. C1 C2 SIZE 9 12 A 39mm 41mm B 150mm 177mm C 304mm 381mm D 302mm 378mm EØ 260mm 337mm F 20mm 20mm G 54mm 54mm SIZE 9 12 A 136mm 171mm B 150mm 177mm C 304mm 381mm D 302mm 378mm EØ 260mm 337mm F 20mm 20mm G 400mm 500mm D1 PREPARATION FOR INSTALLATION E1 Place fan unit, impeller downwards, on a flat surface. Unscrew the grille-securing screw located at the top of the grille. E2 Remove grille. Partially unscrew the two safety catch screws on the face of the housing E3 Depress the side catches. E4 Lift off the housing. E5 Release the Power Supply/Receiver Unit catch, located at the bottom left of the motor body housing assembly. E5a Lift the Power Supply/ Receiver Unit until the second catch engages. Slide the speed controller connection socket from the housing (wired version only). E6 Ease back the motor support safety catch, located to the left of the connector socket opening. Rotate motor body housing anti-clockwise until the bayonet catch disengages. E7 Withdraw motor body housing and place with the impeller downwards. 3

E1 E2 E3 E4 E5a E5 E6 E7 4

INSTALLATION F1 From the inside: Fit the spigot through the fixing hole, with the connector socket cut out at the top. Ensure that the rubber seal is correctly located over the four lugs on the spigot. F2i WINDOW From outside: Place the outdoor grille assembly with the louvres slanting downwards, and the Vent-Axia logo at the top of the grille, over the projecting spigot. F2ii ROOF From outside: Place the exterior roof cowl over the projecting spigot. Use a suitable sealing compound between the cowl and the glass/or roof plate. F3i/ ii Secure the outdoor grille or roof cowl, using the fixing screws supplied. Then tighten the screws in turn to give an even pressure around the hole. F4a/ b Refit the motor body housing assembly and turn clockwise until the locking catch is engaged. Take care not to trap the mains supply cable or the speed controller socket cable (wired version only). F5 Release the Power Supply/Receiver Unit locking catch and lower until the catch engages in the lower position, fix the controller socket into position (wired version only). F6 Lift the black rubber gasket on the Power Supply/Receiver Unit and switch the three-position switch to the required running option, then replace the gasket seal. F7 If a speed controller is being used refer to the relevant Speed Controller Fitting and Wiring instructions. F8 Refit the housing ensuring that no internal wires are trapped between the housing and base. F9 Engage the two side catches. Tighten the two side catch screws. F10 Replace the indoor grille with the louvres slanting upwards, with the Vent-Axia logo at the bottom of the grille, and secure with the retaining screw. F1 F2i F2ii 5

F3i/ ii F4a F5 F4b F7 FOR SPEED CONTROL F6 F9 REFER TO THE RELEVANT FITTING AND WIRING INSTRUCTIONS SUPPLIED WITH THE WIRED/ WIRELESS CONTROL. F10 6 F8

TYPICAL ROOF INSTALLATIONS USING VENT-AXIA ACCESSORIES A (A) ROOF LIGHT All T-Series roof models are designed to fit directly into horizontal and sloping glass including wired cast and sealed double glazing up to 32mm thick. For materials of greater thicknesses extended fixing rod sets are available, allowing the unit to be fixed through a spacing of up to 370mm. Rod thread: 3.5mm Maximum fixing thickness: 370mm B (B) PITCHED ROOF All T-Series roof models may be installed in fixing plates with zinc or lead weathering apron (provided by others), fitted directly to a tiled or slated roof to provide a water-tight installation. A suitable sealing compound should be used between the weathering apron and the exterior unit seal The illustration shows a T-Series roof model fitted with a direct mount spigot and flexible ducting. C (C) CORRUGATED ROOF All T-Series roof models are suitable for fixing through corrugated sloped and vertical cladding using a suitable soaker flange. The soaker flange consists of a replacement sheet with a flat section to carry the unit. A suitable sealing compound should be used between the plate and the exterior unit seal. D (D) FLAT ROOF All T-Series roof models may be installed through solid roofs using a roof plate assembly and, if required, an eggcrate grille or louvred grille in the ceiling below. Alternatively, if ventilation is from a suspended ceiling, single spigots and flexible ducting may be used to connect the unit and extract grille. Roof plate assemblies are manufactured in high impact thermoplastic. A suitable sealing compound should be used between the plate and exterior unit seal. 7

WIRING THE CONNECTOR SOCKET Ensure that the supply (Voltage, Frequency and Phase) complies with the rating label. This appliance must be earthed. F11 Remove the top cover from the connector socket by undoing the 2 retaining screws. F12 Lift up lever and slide out top cover. F13 Loosen cable clamp screws and pass the cable through the clamp. (It may be necessary when using some 3-core cables to reverse the cable clamp to ensure that the cable is securely retained. For ease of wiring, the terminal block may be removed from the connector housing. F14 Tighten cable clamp screws evenly, ensuring a secure grip on the outer sheath of the cable. F15 Slide the top cover back on and secure with the 2 retaining screws. F16 Fit connector socket and push down on the lever to lock it in position. Fig 2 Using an On/Off switch: Connect the mains supply to the fan connector socket. Fig 3 Auxiliary sensor switching: Connect the mains supply to the fan connector socket. F11 F13 F12 F14 F16 F15 Fig. 2 (Wired version only) Please refer also to the speed controller fitting and wiring instructions. 8

Fig. 3 (Wired version only) Please refer also to the speed controller fitting and wiring instructions. ISOLATE FROM THE POWER SUPPLY PRIOR TO ANY MAINTENANCE AND CLEANING USER INSTRUCTIONS At intervals appropriate to the installation, inspect and clean the fan to ensure there is no build up of grease or dirt on the impeller or the motor. The motor is fitted with sealed for life bearings and does not require lubrication. DISMANTLING G1 From the inside, remove the connector socket by lifting up the lever gently with a finger, unplug the controller cable (wired version only). G2 Unscrew the indoor grille retaining screw and remove the grille. G3 Partially unscrew the two side catch screws on the housing and depress the two side catches. G4 Remove the housing. G5a Release the Power Supply/Receiver Unit catch, located at the bottom left of the motor body housing assembly. G5b Lift the Power Supply/Receiver Unit until the second catch engages. Slide the controller socket from the housing (wired version only). G6 Release the motor body housing assembly locking catch located to the left of the connection socket opening and rotate the motor body housing assembly anti-clockwise until the bayonet catches disengage. G7 Withdraw the motor body housing assembly and put to one side, with the impeller facing upwards. G8 Remove the impeller with a sharp pull away from the motor. G9 Unscrew the outdoor grille retaining screw and remove the grille. CLEANING IMPORTANT: Keep all electrical components away from water. G10 Wipe the motor, housing assembly and roof cowl (if fitted) with a damp cloth. G11 Wash all non-electrical components in warm water and detergent. 9

REASSEMBLY - ALLOW THE COMPONENTS TO DRY BEFORE REASSEMBLY G12 Replace the outdoor grille with the louvres slanting downwards, and the Vent-Axia logo at the top of the grille. Tighten the retaining screw located at the bottom of the grille. G13 Align the impeller with the locating pins on the motor shaft and refit the impeller with a sharp push. G14a/b Refit the motor body housing assembly and turn clockwise until the locking catch is engaged. Take care not to trap the speed controller socket cable (wired version only). G15 Release the Power Supply/Receiver Unit locking catch and lower until the catch engages in the lower position, fix the controller socket into position (wired version only). G16 Refit the housing ensuring that no internal wires are trapped between the housing and base. G17 Engage the two side catches. Tighten the two side catch screws. G18 Replace the indoor grille with the louvres slanting upwards and the Vent-Axia logo at the bottom of the grille, then secure with the retaining screw. G19 Replace the connector socket, push firmly into position and press the black locking peg down flush with the top of the connector socket. Plug the controller cable connector into the socket (wired version only). RECONNECT THE MAINS SUPPLY AND SWITCH THE UNIT ON. G2 G1 G3 G4 G5a G5b G6 G7 G8 G9 10

G10 G11 G12 G13 G14a G15 G14b G16 G17 G18 G19 11

VENT-AXIA SALES CENTRES ENGLAND & WALES NATIONAL CALL CENTRE SCOTLAND Newton Road, Crawley West Sussex Telephone: 0141 429 1166 RH10 9JA Fax: 01293 565169 Telephone: 01293 530202 REPUBLIC OF IRELAND Fax: 01293 565169 Vent-Axia Ventilation Ltd. 921 Western Road Industrial Estate NORTHERN IRELAND Naas Road, Dublin 12. Telephone: 02890 402220 Telephone: (01) 450 4133 Fax: 01293 565169 Fax: (01) 450 4570 Did you find these instructions easy to use? We value your comments, contact us via : Email: info@vent-axia.com The Vent-Axia Guarantee Applicable only to products installed and used in the United Kingdom. For details of the Guarantee outside of the United Kingdom contact your local supplier. Vent-Axia guarantees this product for two years from the date of purchase against faulty material or workmanship. In the event of any part being found to be defective, the product will be repaired, or at the Company s discretion the product will be replaced without charge, provided that the product: 1). Has been installed and used in accordance with the instruction given with each unit. 2). The electricity supply complies with the rating label. 3). Has not been misused, neglected or damaged. 4). Has not been modified or repaired by any person not authorised to do so by Vent- Axia. IF CLAIMING UNDER THE TERMS OF THE GUARANTEE Please return the complete product, carriage paid to your original supplier by post or in person. Please ensure that it is adequately packed and accompanied by a letter clearly marked Guarantee Claim stating the nature of the fault and providing proof of the date and source of purchase. As part of the policy of continuous product improvement Vent-Axia reserve the right to alter specifications without notice Head Office: Fleming Way, Crawley, West Sussex RH10 9YX Tel: 01293 526062 Fax: 01293 551188 Internet site at: www.vent-axia.com 428208C 0205 12