Original Perfusor & Infusomat

Similar documents
Proven Quality Made in Germany

Perfusor fm. Instructions for Use. Software PFAE

M E D I C A L D E V I C E S

Sapphire TM. Bring Home The Future Of Infusion Care. Ambulatory Infusion System. > Intuitive, easy-to-use touch screen design

Syringe Pump. User Manual

TPCA TM PATIENT CONTROLLED ANALGESIA SYRINGE PUMP


Infusion System. Infusion and Syringe Pumps

Ambulatory infusion pump for continuous, intermittent, TPN or PCA delivery.


Alaris Syringe module FAQs

ila ACTIVVE SYSTEM PLATFORM

Vernay-QM Series Disposable Pumps

Efficiency at Hand. Digital Radiography GF50 Series CT-GF EN. Tube 300kHU (210kJ) 150kHU (105kJ)

Getinge WD14 Tablo Tabletop washer-disinfector. Fast and with high-throughput

The Professional Choice

HOMEPUMP ECLIPSE* Ambulatory Infusion System PATIENT INFORMATION

GETINGE WD14 TABLO A GOOD-LOOKING TABLETOP WASHER-DISINFECTOR. Always with you

SN-50 Serial Syringe Pump User Manual. Version: 2.6

CONTENTS. III. OPERATING INSTRUCTIONS... pg 7 LOADING DISPOSABLE SET (Figure 4)... pg 9. IV. INDICATORS AND ALARMS... pg 10

Clinician Information

EM-MED. EmTherm. warming. cabinets

SECTION L MONITORING EQUIPMENT

T34TM AMBULATORY SYRINGE PUMP

Technical Update TAA.TU rev. 1

ATMOS Surgical Suction

Alaris Syringe Module v9

The Professional Choice

ACCUVAC Pro Experience in Great Shape Professionals Demand Nothing Less

Directions for Use. Alaris System. Alaris Products. Supports Guardrails Suite MX (v8) August RATE (ml/h) RATE (ml/h) CHANNEL SELECT PAUSE

Alaris Syringe Module v9

Getinge WD14 Tablo Tabletop washer-disinfector

Just as flexible as your plans The Bosch Modular Fire Panel 5000 Series

SEPTIC FLUID ASPIRATOR MEDAP-VENTA SP 26 N MEDAP-VENTA SP 26 A

GETINGE WD15 CLARO 1 GETINGE WD15 CLARO THE CLEAR CHOICE IN WASHER-DISINFECTORS. Always with you

alpha.line FIRST CHOICE FOR SMALL AND MEDIUM FORMATS Member of the technotrans group

Description of the CADD-Prizm VIP Pump

ADRIA intelligent room system

Product overview. Alarm indicator, operator and display panels

stationary dose rate measuring systems

Section. 3: CADD Pump. Updated: June 20, Section Author(s): sstafford & jhval

V Series Infusion Pump User Manual. Version 0.2

Fire control panel detect 3004 plus and accessories

Directions for Use Alaris System (with PC Unit, Model 8000)

Affordable wireless monitoring without compromise

Zoom Microplate Washer and Washer-Dispenser. Reliable Solutions for Your Daily Work

DS User Manual

SMART BASIC BASIC-IR DAYLIGHT

PD240 NEW GENERATION WIDE SEARCH AREA HAND HELD METAL DETECTION SET FEATURES

Modular Fire Panel 5000 Series Just as flexible as your plans

IQ8Control C Fire Alarm Panel

PR / MP I Laboratory / Medicine

ACCUVAC Lite Simply Strong Suction Made Easy

NEW GENERATION COMPACT HAND HELD METAL DETECTION SET

Medical Refrigerators

Nellcor Bedside SpO 2 Patient Monitoring System, PM100N

Temperature Control Systems

Mercury Vapor Monitor VM-3000

Speed and Frequency Seite 1 von 7

SISTEMAS PARA PRUEBAS DE ESTERILIDAD

TopLine Active protection of patients and nursing staff

Nedap Cow Positioning with integrated Heat Detection and Health Monitoring

Huminator II. Precision Humidity Generator. ww.testo.in

PD240 NEW GENERATION WIDE SEARCH AREA HAND HELD METAL DETECTION SET

CLEO VERSATILITY IN VITAL SIGNS

. ATP. Ultra-fast and reliable. CONSIS pouch packagers.

qube mini Overview

SYRINGE PUMP OPERATING MANUAL

in mobility Gentle & precise cleaning of sensitive Very quiet air-cooled system Large operating distance (up to 250 mm) Laser class 4 product

PD140N NEW GENERATION COMPACT HAND HELD METAL DETECTION SET. Threat Detection through Electromagnetics. NIJ Compliant.

Getinge WD15 Claro Washer-disinfector

Sensistor ISH2000 Hydrogen Leak Detector

Light is simple Compact Monsun The LED damp-proof luminaire range for challenging lighting tasks.

Innova new M2 and M3 series

PG 8535 Perfect Reprocessing

XTREMA PWD ASEPTIC POWDER FILLING & STOPPERING MACHINE

Oxygen measuring device Operating manual

E-pro. Time adaptor with E-Pro Stick for thermostatic valves

Plasma Thawer. model WPFD. Comformity with: GMP CNT JACIE FACT. WPFD Plasma Fast Thawer Medical Device - CEE 93/42

Post-operative wound drainage High-vacuum drainage Low-vacuum drainage Gravity drainage

SpotOn Temperature Monitoring System. SpotOn. Temperature Monitoring System. Model 370 Installation and Service Manual

MEMS Accelerometer ICs. AMR Magnetic Sensor ICs. Gas Flow Modules. Differential Pressure Sensors. Tilt Modules. Current Sensors

G 7823 PG Washer-disinfectors for hospitals and central sterilisation departments

Cl inician Training Packet

EL-OEM-3 OEM Packaged Voltage Data Logger

Zoom HT Microplate Washer. The Fastest Microplate Washer For The Life Sciences

Your Health, our Technology AWD655. Instrument Washer Disinfector

Deep Freezers. Freezers. Biomedical Refrigeration I FR / MF

DEEP FREEZERS AND PLASMA STORAGE FREEZERS. Biomedical Refrigeration I FR / MF TECHNOLOGY FOR LIFE

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

Omni (K) PATIENT MONITOR

DEKO 190 Ward washer-disinfector

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

WHA 3000V Hot Air Station

Affordable wireless monitoring without compromise

VM-3000 Mercury Vapor Monitor

ATMOS Bronchial Suction

CSF. Contact Shock Freezers. Blood Management Solutions. B Medical Systems CSF Range

RIGID DC LIQUID CHILLER

Drying and heating chambers

Transcription:

Original Perfusor & Infusomat Your solution for every application System capable, user-friendly, reliable.

fm system workstations The entire spectrum of fluid management One system for all requirements leading in application, operation and documentation. High flexibility in adapting to different tasks and ambient conditions. Flexible pump operation with a selection of 5 different types. Central management of up to 18 infusion pumps. Easy settings, status and trend monitoring, clear display of fluid balance. Prevention of medication errors by simplified, safe entries via bar code scanner and compileable drug list specific to the ward. Easy adaption to Patient- Data-Management and Hospital-Information Systems. Optimised propofol dosing Greater efficiency for i.v. anaesthesia: In OTCI mode (Optimised Target Controlled Infusion), an optimised pharmacokinetic algorithm automatically controls the level and maintenance of the required delivery rates. Please ask for more information about fm system workstations!

Original Perfusor accessories A system for safety Original Perfusor and Omnifix syringes with their excellent performance complement the outstanding delivery characteristics of Perfusor syringe pumps. Optimized start-up characteristics and consistent delivery are guaranteed always. Original Perfusor infusion lines with luer-lock connectors always ensure safe hook-ups to the system. A large selection of syringes and infusion lines for specific applications. PRO-SET solutions for the infusion regimen Configure your own complete, ready-to-use infusion systems from a broad range of products: Infusion lines available in various models. Infusion filters (0.2 mm and 1.2 mm) for lipid emulsions and mixed solutions Manifold stopcocks and customised sets. Back-check valves, safety connectors and ports. Please ask for your specific PRO-SET solution!

Flexibility and mobility: Perfusor compact and Perfusor compact S Leading-edge technology in a compact design Easy syringe change, automatic size-recognition and proper fixation. Excellent start-up characteristics, high accuracy of the set delivery rate and flow consistency even at low infusion rates. Appropriate delivery rate adjustment without the need for interruption of the delivery. Bolus application at the touch of a key with simultaneous display of the delivery volume. Innovative pressure sensor Short reaction time during occlusion for every syringe size. Automatic bolus reduction for re-starts with more accurate dosage following a pressure alarm. Perfusor compact The handy syringe pump for the use on all wards. Stackable mobile units that lock together Mobile performance packages consisting of up to 3 Perfusor compact units which lock together for safe transportation, allowing uninterrupted continuation of infusion therapy during patient transportation. Battery operation for up to 80 hours The Perfusor compact can be battery operated. The inexpensive AA batteries can be exchanged easily. Perfusor compact S Wide selection of syringes and very low delivery rates for the special requirements in paediatrics and neonatology. Performance data Perfusor compact and Perfusor compact S Model, Classification Syringe pump, CF, defibrillation-proof, protection class II, IIb (complies with CE/MPG). Syringe selection Perfusor compact: 20 and 50 ml. Perfusor compact S: 2/3, 5, 10, 20, 30 and 50/60 ml, user-specific configuration possible. Delivery rate Perfusor compact: 0.1...99.9 ml/h. Perfusor compact S: 0.01...200.0 ml/h (depending on the syringe size used). Accuracy Accuracy of the set delivery rate: typ. ± 2%, (measurement time >1h and delivery volume > 2 ml). Bolus parameters Bolus rate Perfusor compact: 800 ml/h. Bolus rate Perfusor compact S: 1-1200 ml/h. Function spectrum Delivery volume pre-setting: 0.1 to 999.9 ml. Perfusor compact S: Time pre-selection: 00:01 to 99:00 h. Perfusor compact S: Automatic calculation of the delivery rate based on volume over time. Standby infusion pause: pre-set values remain stored. Display Display: syringe type/size, delivery rate, current infusion, infused volume, pressure alarm, alarm sources, mains/battery operation/capacity. Safety system Automatic recognition of syringe size/fixation. Occlusion alarm pressure limits selectable: 0.3/0.6/1.2 bar. Automatic reduction of the bolus volume following pressure alarm. Perfusor compact S: Data Lock keys are blocked. Pre-alarms; 3 min. before syringe is empty, 30 min. before battery is discharged. Visual and acoustic alarms with interruption of pump operation: incorrect syringe insertion / fixation, occlusion, end of delivery, empty syringe, battery discharged. Alarm reminders in case of no input. System alarm signals a defect/delivery failure. Staff call connection. Interfaces RS 232, MFC-Plug-in contact for fm system workstations. Mains Integrated power supply, rated voltage 230/240 and 100/110 V, 50/60 Hz ~ Power consumption: 12 VA. External extra-low voltage: 12 V DC. Battery operation Battery type: 4 x 1.5 V DC alkaline-manganese, (non- rechargeable). Battery operating time > 80 h at 10 ml/h. Optional battery pack, rechargeable. Battery operating time >10 h at 10 ml/h, re-charge time >16 h. Dimensions (W x H x D): 190 x 100 x 120 mm. Weight 1.5 kg approx.

Precision and variety: Perfusor fm Safety and operating convenience for all applications Allows simple and fast syringe exchange with automatic fixation. Wide range of syringes to select from. Identification of the size in use. The integrated text display with operator guidance prompts provides all information necessary for making safe entries. Shorter alarm reaction times in case of system occlusion and automatic bolus reduction prevent incorrect dosing. High delivery performance, large range of settings The ultimate in accuracy for delivery rates and flow consistency. Excellent start-up characteristics for infusions with accurate dosages, starts even at low infusion rates. Perfusor fm With an outstanding performance spectrum to face the challenges of anaesthesia and intensive care medicine. TIVA mode for effective anaesthesia Drug parameters can be entered directly. Delivery rates are calculated automatically based on the entered values for patient body weight. Quick adjustment of dosage without interrupting infusion. Drug-specific or volumetric bolus, freely selectable bolus parameters. Flexibly adaptable, expandable by modular options Syringe selection and function spectrum can be configured to meet specific user needs. Easy to extend performance spectrum with updating/ upgrading of performance parameters using PC programs. Modular expansion saves the need for specially dedicated pumps: PCA module History module for treatment analysis. Can be integrated into fm system workstation solutions. Perfusor fm with PCA Module Free selection between PCA and standard functions. Hierarchy system for safe therapy management. Individual parameter settings and reports on the course of therapy. Performance data Perfusor fm and PCA module Model, classification Syringe pump, CF, defibrillation-proof, protection class I (complies with CE/MPG). Syringe selection 10 ml Omnifix, 20/50 ml Original Perfusor syringes (additional syringes available on request). Delivery rate 0,01...200,0 ml/h. Accuracy Accuracy of the set delivery rate: typ. ± 2%, (measurement time >1h, min. 2 ml). Bolus parameters Bolus volumes: 0.1...50.0 ml. Bolus delivery rate: 1.0...1800.0 ml/h. Interval times: max. 99 h 59 min. Application parameters Selectable modes: ml, μg or mg. PCA-module Concentration: 0.001 999.9 μg or mg/ml. Bolus: 0.1...9.9 ml. 1), Lockout time: 1 min... 4 h. Initial bolus: 0...20.0 ml. 1),, Basal rate: 0...20.0 ml. 1) Dosage limitation: 0...500 ml 1)., Observation interval: 1 8 h. Function spectrum Delivery volume pre-setting: 0.1 to 999.9 ml. Time pre-selection: max. 99 h 59 min. Automatic calculation of the delivery rate: based on volume and time pre-selection. Dose rate calculation: automatic calculation of the delivery rate, ml/h based on the entry of drug concentration in conjunction with the desired dosage, selectable in μg, mg, IE, mmol, body weight and time-based, e.g. mg/kg/min. Standby pause: max. 99 h 59 min, pre-set values remain stored. Display Delivery rate, current infusion, infused volume/time, dose, mains/battery operation, battery capacity, h/min. up to 9 drug names. Functions/operator guidance and alarm causes in plain text. Safety system Automatic syringe fixation by pressing a button. Automatic recognition of syringe size: 10/20/50 ml. Occlusion alarm pressure limits: 9 adjustable levels from 0.2 1.0 bar. Automatic reduction of the bolus volume following pressure alarm. Data lock: keys are blocked. Visual and acoustic alarms with interruption of pump operation: signals delivery failure in case of system defects, syringe alarm, pressure alarm, stand-by alarm, battery alarm. Pre-alarms: 3 min. before syringe is empty or battery is discharged. Staff call connection. Interfaces RS 232: MFC-Plug-in contact for fm system workstations. Service Integrated service programme: for application-specific configuration of function spectrum and technical diagnosis. Mains/battery Rated voltage: 200/230/240 V ~, 50/60 Hz, external extra-low Operation voltage: 12 VA. Battery type: NiCd, battery operating time: > 3.5 h at 25 ml/h. Re-charge time: > 16 h. Dimensions (W x H x D): 360 x 110 x 170 mm. Weight: 3.5 kg approx. 1) value given in ml/μg/mg depending on the concentration

Safety and economy: Infusomat fms Broad performance spectrum, easy settings Infusion rates and drug parameters can be entered directly. Delivery rates are calculated automatically based on volume and time pre-selection or on the values entered for patient body weight. Fast adjustment of delivery rate and dose without the need to interrupt the delivery. Freely selectable bolus applications can be administered at the touch of a key. Switching between a primary and a secondary infusion in piggyback mode. History function for clinical course analysis. The most important parameters are always visible The large display and the ergonomic design of the user interface make adjustments and monitoring easier. Operator guidance prompts provide all information for safe operation. Infusomat fms Use Original Infusomat infusion line for the highest accuracy of the set delivery rate and maximum consistency even over long periods. Simple set change, high degree of safety Proper placement into the securing fasteners. A flow clamp prevents free flow when the pump door is opened. The air detector minimises the risk of air infusion. Adjustable pressure limits result in a reduction of the bolus volume and shorter alarm reaction times in case of system occlusion. Flexibly adaptable, modular expandable Function spectrum can be configured to meet the user s specific needs. Easy to extend performance spectrum with updating/ upgrading of performance parameters using PC programs. Can be integrated in fm system workstation solutions. Performance data Infusomat fms Model, classification Volumetric infusion pump: CF, defibrillation-proof, protection class I (complies with CE/MPG). Delivery rate 0.1...999.9 ml/h. Accuracy Accuracy of the set delivery rate typ. ± 5% over a 96-h period with Original Infusomat infusion line. Bolus parameters Bolus volumes: 0.1 99.9/500.0 ml. Bolus delivery rate: 1 999.9 ml/h. Interval times: max. 99 h 59 min. Function spectrum Delivery volume pre-setting: 0.1 to 9999.9 ml, Time pre-selection: max. 99 h 59 min. Automatic calculation of the delivery rate: based on volume and time pre-selection. Dose calculation: automatic calculation of the delivery rate, ml/h based on the entry of drug concentration in conjunction with the desired dosage, selectable in μg, mg, IE, mmol, body weight- and time-based, e.g. mg/kg/min. Standby pause: max. 24 h, set values remain stored. Piggyback: sequential delivery of primary and secondary infusion by switch-over. History: time-based storage of 350 actions for therapy analysis. Display Delivery rate, current infusion, infused volume/time, dose, mains/battery operation, battery capacity. Up to 9 drug names. Functions/operator guide and alarm causes in plain text. Safety system Deactivation of drip control: in conjunction with volume pre-selection. Flow clamp: prevents free flow when pump door is open. Air detector: minimizes risk of air infusion. Selectable occlusion alarm pressure settings, Infusomat fms: 0.4/0.8/1.2 bar, Infusomat P: 0.6/1.2 bar. Data Lock: keys are blocked. Visual and acoustic alarms with interruption of pump operation: signals delivery failure in case of system defects, syringe alarm, pressure alarm, stand-by alarm, battery alarm. Keep-Open Rate (KOR): for a delivery rate >10 ml/h = 3 ml/h; for a < 10 ml/h = 1 ml/h. Staff call connection. Interfaces RS 232: MFC-Plug-in contact for fm system workstations. Service Integrated service programmme: use-appropriate configuration of function spectrum and technical diagnosis. Mains/battery Rated voltage: 200/230/240 V ~, 50/60 Hz Operation External extra-low voltage: 12 V. Battery type: NiCd; attery operating time at max. delivery rate: 3.5 h, Re-charge time: >16 h. Dimensions (W x H x D): 140x240x200 mm, Weight: 3.1 kg approx.

Original Infusomat accessories A system for safety Original Infusomat infusion line is perfectly matched to both the peristaltic pump and its integrated safety system. As a result, the outstanding performance characteristics of the Infusomat fms ensure high delivery accuracy and consistency and, most importantly, optimal functioning over long periods.

Braunostat organizer systems Customised configuration, universal adaptability Braunostat W/D systems are easily adapted to conventional ward equipment like stands, rails or ceiling units. The modular components can be universally combined with each other, are easy to assemble and can be quickly adapted to changing conditions. For stationary and mobile applications Universal Braunostat U infusion stand for holding up to 3 infusion pumps. Braunostat B bedside infusion tripod for holding up to 3 syringe pumps or 1 volumetric infusion pump. Please ask us for more product information!

B. 02. 05. 07/3 Nr. 606 1880 B. Braun Melsungen AG 34209 Melsungen Germany Tel +49 (56 61) 71-0 www.bbraun.com