Inde-Pendants Family. 32L Cylinder with Ring Open Ceiling Types. Document No Installation instructions for 32L-CRxx-P-ID 32L-CRxx-P-D

Similar documents
Inde-Pendants Family. 32L Cylinder Plaster Trim, Grid and Drywall Ceiling Types. Document No

Installation Instructions

Fillmore Small Pendant Assembly and Installation Instructions

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

WARNING Risk of fire and electrical shock. DISCONNECT POWER AT ELECTRICAL PANEL before installing or servicing this product.

Owner s Guide and Installation Manual

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

CEILING FAN OWNER S MANUAL

IMPORTANT SAFETY INSTRUCTIONS:

Ceiling Fan Blade Arm Replacement

Step 1: Identify the parts of your shade (parts shown are not to scale)

IMPORTANT SAFETY INSTRUCTIONS:

Installation Manual. Models 99168, 99169, 99170

Damp Locations Wall & Ceiling Mount BEFORE YOU BEGIN

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

Service Manual 26 Self Trimming Fireplace with 3 Stage Remote

5AZR56XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5AZR56XX

SWIVEL HEAD WASTE AND OVERFLOW INSTALL

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

Owner s Guide and Installation Manual

ELSTON 52 CEILING FAN

ST. KITTS CEILING FAN

Pole Mounting System Installation & Certification Manual

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Preparation. Wiring. Downrod.

TOUCHDOWN 48 CEILING FAN

5Make electrical connections.

MILLENIUM MEMBRANE REPLACEMENT. Tools and Materials Required. Initial Preparation

Decorative Low Profile Integrated Kit

Owner s Guide and Installation Manual

BK AND BKT BLOWER ACCESSORY INSTALLATION INSTRUCTIONS

Service Manual 26 Self Trimming Export Fireplace with 3 Stage On/Off Remote

5YK60XXX Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 5YK60XXX

Type 2 Models. Owner s Guide and Installation Manual. English Español

60" Lyndon Patio. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

WARNING: ELECTRICAL GROUNDING INSTRUCTIONS

AFTER INSTALLATION DELIVER THIS MANUAL TO OWNER IMPORTANT SAFETY INSTRUCTIONS

TRUSTY PRODUCTS, INC.

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

5COM52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5COM52XXD

INSTALLATION INSTRUCTIONS

Undercounter Refrigeration

Bravo II. High Performance Multi-Purpose Speaker

SPRINGHILL 44 CEILING FAN

Installation Manual Mopar Engine Compartment Upgrade Kit

Installation Instructions for Vertical Blind

DP25 & DR25 RECESSED T-BAR INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

ITEM # , , PAWTUCKET CEILING FAN MODEL #40958, 40959, 40047

DPM-G DPM-CR DPM-W DPM-B INDOOR DOME PENDANT MOUNT INSTALLATION MANUAL

ITEM # SAIL STREAM CEILING FAN MODEL #40048

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET. Model Series FEATURES SPECIFICATIONS INSTALLATION

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

DAGNY LK. Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 110V~60Hz

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Downrod. Blades. Maintenance & Cleaning.

installation and operation manual for Hunter Ceiling Fans

52 CEILING FAN. Owner s Manual Models #50336, 50337

3DIR52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3DIR52XXD

5GFR52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5GFR52XXD

Installation Instructions

INSTALLATION INSTRUCTIONS. Vertical Blinds

INSTALLATION INSTRUCTIONS

CoolTouch TM control system

Torrena 42 Ceiling Fan

Table of Contents What to Expect with. Tools Needed. Mounting Options. Wiring. Downrod. Canopy.

Camarillo 52 Ceiling Fan

The Marine Throne. Model TMT S/37045/X-Series QUIET - FLUSH ELECTRIC TOILET. "all the comforts of home" FEATURES SPECIFICATIONS INSTALLATION

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Wall Control

INSTALLATION INSTRUCTIONS

HEATING CABLE RATINGS APPROVALS* Drexan Energy Systems, Inc. Kelowna, BC, Canada, V4V 1S5

Vari-Cyclone Ceiling Fans

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed.

3VNR52/42XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3VNR52XXD / 3VNR42XXD

INSTALLATION INSTRUCTIONS

installation and operation manual for Hunter Ceiling Fans

Cooktop Chimney Ventilation Hoods

Fluid Round Large 700 FMFLDRL_

DRAIN WATER TEMPERING INSTALL

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Mopar B-Body Condenser Kit with Drier

PERIOD ARTS FAN CO. Customer Service M-F 8am - 4pm (PST)

Innes. Instruction Manual A Kichler Decor ceiling fan. Includes our new TM

TILGHMAN CEILING FAN ITEM # MODEL #WCK44NWZ5L1. español p. 21 ATTACH YOUR RECEIPT HERE. Serial Number. Purchase Date

Model: EF34. Owner's Guide & Installation Manual

Table of Contents What to Expect with. Mounting Options. Tools Needed. Downrod. Blades

3MAVR60XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MAVR60XX

OP40R 40cm Remote Control Pedestal Fan

Installation Instructions

PARISIAN ARCHITECTURAL BRASSERIE PENDANT 9

62" LED SPYRA. Product images may vary slightly from actual product. INSTRUCTION MANUAL

Sunstruck Installation Manual

Instructions Apply For Model PHTT-6P-KFC. Panel Shelf Is Removed to install warming drawers

Table of Contents. What to Expect with. Mounting Options. Tools Needed

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

ARMITAGE CEILING FAN ITEM # MODEL #CC52WW5L. Español p. 17 ATTACH YOUR RECEIPT HERE. Purchase Date

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

Owner s Guide and Installation Manual

Transcription:

Inde-Pendants Family 32L with Ring Open Ceiling Types Installation instructions for 32L-CRxx-P-ID 32L-CRxx-P-D 510649-01 Document No. 510649-01

Supplied by Litecontrol 32L Inde-Pendants: with Ring (Open Ceiling Applications) Outlet Box Cover SCALE 1:5 (fixture) SCALE 1 : 5 J-box/Cable Kit Assembly with mounting hardware SCALE 1 : 5 Supplied by Contractor Ring (fixture) (30" Ring shown) SCALE 1 : 5 Standard 4 X 4 octagonal outlet box with mounting hardware Feed cord Wire nuts Tools Required Wire cutters/strippers Tape measure Marker Felco-type cable cutters 1/4" Socket with wrench or flat-head screwdriver Level 2 510649-01

J-box Installation 3 1 2 3 J-box 1/4-20 Stud J-box 4"x4" Octagonal Outlet Box (not included) Magnet J-box Cover Knockout Outlet Box Cover 1/4-20 Stud Outlet Box Hardware (not included) Wing Nut Bottom Plate #8 Sheet Metal Screw 1. The J-box (provided) installs on a standard 4x4 octagonal outlet box. The outlet box must be installed per code at the support location prior to J-box installation. 2. Install the provided Outlet Box Cover on the octagonal outlet box as shown using the screws provided with the outlet box. 3. Bring the wires out of the octagonal outlet box through the knockouts in the Outlet Box Cover. 510649-01 1. Remove the Bottom Plate of the J-box. 2. Remove knockouts from J-box top as needed. 3. Install electrical feed cord in the J-box. 4. Lift the J-box up while sliding the 1/4-20 Stud in the Outlet Box Cover through the center hole in the top of the J-box so that it fits tightly against the Outlet Box Cover. 5. Secure the J-box in place with the wing nut and make all wiring connections (see attached wiring diagrams). 6. Re-install the bottom plate using the two #8 screws. 1. Bring the J-box Cover up the cables until it presses against the bottom of the J-box. The J-box Cover will be held in place by the pre-installed magnets on the bottom of the J-box. Completed J-box installation should match Figure 1 on page 7.

Installation 4 1 2 3 Uplight Sub Assembly Lock Nut Outer Gripper Outer Gripper Uplight Sub Assembly 2" Felco-type Cable Cutters Lock Nut Outer Gripper 1. Once the J-box has been properly installed, lower the Uplight Sub Assembly to the desired fixture height by adjusting the outer grippers below it (adjust grippers by loosening lock nuts and pressing them against grippers) 2. Level the assembly Note: For configurations with no Uplight, there will only be 2 Outer Grippers. The minimum height from the ceiling is 12" (see step 8 for visual reference). The top of the Uplight sub assembly will be flush with the top of the cylinder after the fixture has been fully installed. 1. Measure 2" below the Uplight Sub Assembly and mark the location with a permanent marker 2. Cut the cables at the marked location using FELCO-TYPE CABLE CUTTERS. 1. Move the Uplight Sub Assembly and Outer grippers up and out of the way temporarily by loosening lock nuts and pressing them against the grippers Exterior Metallic Sheathing Coaxial Cable 4 5 6 Lock Nut Gripper Letters on bottom face of Uplight Sub Assembly Red Blue Blue 1" Plastic Interior Lock Nut Gripper Inner Aircraft Cable 1. Measure 1" from bottom of the cable and mark the location 2. Strip 1" of the metallic exterior and plastic interior off of the coaxial cable (using 16 gage wire strippers), leaving 1" of the inner aircraft cable exposed. (Left Image) 3. Twist and move the metallic exterior jacketing up so that 1/8" to 1/4" of the plastic interior is exposed. IMPORTANT: Do not let the exterior metallic sheathing and the inner aircraft cable touch. (Right Image) 510649-01 Cable 1. Match the letter indicators on the Uplight Sub Assembly with the letters on the to ensure correct fixture orientation. 2. Loosen the Gripper Lock Nuts 3. Feed the cables into their respective grippers as far as they'll go in 4. Check that the is level and adjust the cables accordingly before fully securing the gripper lock nuts. 1. Make the wiring connections as shown in the above image between the blue and red wires in the and Uplight Sub Assembly. If there is no uplight, no wiring is required to the Uplight Sub Assembly (no red wire connections). 2. Using three wire nuts, connect red wire with red wire, and each blue wire with respective blue wire according to the alignment between the and the Uplight Sub Assembly.

Installation 5 7 8 9 Flush with Surface X Outer Gripper Exterior Metallic Sheathing Plastic Interior Inner Aircraft Cable 8-32 Mounting Screw Void Outer Gripper with Ring Uplight Sub Assembly 1. Lower the Outer Grippers so that they are inside the voids and flush with Surface X. The Outer Grippers should not be exposed at all above the voids. Note: If the Outer Grippers come off of the Exterior Metallic Sheathing and are no longer making contact with it, secure them back on the cables by removing the cable from the gripper completely, removing the Outer Gripper, twisting/tightening the Exterior Metallic Sheathing, and putting the Outer Gripper back on the cable by completely loosening the plastic cap on the gripper and feeding the cable into the Outer Gripper while twisting the Outer Gripper. The Outer Grippers must be in contact with the Exterior Metallic Sheathing for the fixture to illuminate. 510649-01 1. 2. 3. Remove the 8-32 Mounting Screw from the. Lower the Uplight Sub Assembly onto the Reinstall 8-32 mounting screw thereby securing the Uplight Sub Assembly to the. For only fixture (left), the installation is now complete. Reverse instructions to uninstall fixture and J-box. For with Ring fixture (right), see Ring installation sheets to complete installation. Completed installation should match Figure 2 on page 7.

Ring Installation 6 1 2 Ring Labels Cable Gripper lock nut Gripper Joiner bracket Labels 1. Insert cables into grippers as far as they can go by first loosening the lock nut and inserting the cable fully. You will hear audible "clicks" which indicate that the cable is correctly inserted into the Align the labeled power over aircraft cables coming from the with the grippers in the ring 1. using their respective labels (+ or positive, - or negative and or unpowered). 510649-01 gripper. 2. If finer leveling is required, remove cable from gripper, trim as necessary (up to 0.5") and reinstall into gripper. 3. Tighten the lock nut and remove the labels on the ring and the cables. Completed fixture installation should match Figure 3 on page 8.

Figure 1 Completed J-box installation J-box Cover 7 Class 2 Powered Coax Cables Uplight Sub Assembly Outer Grippers with preinstalled wires Figure 2 Completed installation 1/16" Powered aircraft cables

Figure 3 Completed fixture installation 8 J-box Cover Class 2 Powered Coax Cables 1/16" Aircraft Cables Ring wiring instructions Make Class 2 connections between red wire in cylinder and red wire in uplight sub assembly (only for fixtures with uplight) Red Uplight Sub Assembly Blue Blue Make Class 2 connections between blue wires in cylinder and blue wires in uplight sub assembly

WIRING DIAGRAMS APPLICABLE FIXTURE TYPES: 32L-CRxx-P-ID 9 DRIVER "A" DIRECT DISTRIBUTION DRIVER STANDARD WIRING DRIVER "B" RING DRIVER GREEN: COMBINED GROUND DRIVER "C" INDIRECT DISTRIBUTION DRIVER ALTERNATIVE FIELD WIRING OPTIONS DRIVER "A" DIRECT DISTRIBUTION DRIVER SINGLE CIRCUIT SUPPLY WIRING DRIVER "B" RING DRIVER GREEN: COMBINED GROUND BLACK: COMBINED LOAD (+) WHITE: COMBINED LOAD (-) DRIVER "C" INDIRECT DISTRIBUTION DRIVER

ALTERNATIVE FIELD WIRING OPTIONS (CONT'D) 10 NIGHTLIGHT CIRCUIT WIRING GREEN: COMBINED GROUND BLACK: COMBINED LOAD (+) WHITE: COMBINED LOAD (-) Out of the 3qty total drivers/distributions present in the CR-ID Series fixtures, there are no restrictions with regard to final application driver/distribution pairing for Nightlight wiring. (eg. Driver #1 can be paired with Driver #2 OR Driver #3 to leave the remaining single circuit open to select for Nightlight operation of luminaire) In addition, either of the post-wiring circuits can be selected to act as the dedicated Nightlight portion in the end-product installation.

WIRING DIAGRAMS (NO UPLIGHT) 11 APPLICABLE FIXTURE TYPES: 32L-CRxx-P-D STANDARD WIRING (CAN ALSO BE USED IN NIGHTLIGHT APPLICATIONS) DRIVER "A" DIRECT DISTRIBUTION DRIVER GREEN: COMBINED GROUND DRIVER "B" RING DRIVER ALTERNATIVE FIELD WIRING OPTIONS DRIVER "A" DIRECT DISTRIBUTION DRIVER SINGLE CIRCUIT SUPPLY WIRING DRIVER "B" RING DRIVER GREEN: COMBINED GROUND BLACK: COMBINED LOAD (+) WHITE: COMBINED LOAD (-)

Label Positioning If fixture is damaged or additional assistance is needed, call the number on the label to speak with a Litecontrol representative 12

Ring Label Positioning If fixture is damaged or additional assistance is needed, call the number on the label to speak with a Litecontrol representative 13 CONTACT LITECONTROL MODEL: 32L LMA FOR REPLACEMENT PARTS DATE: 781-294-0100 CCT: 159392 I_ c (ffi us