SECURITY SYSTEM 4110DL. Programming Form Programming Form Programming Form 4110DL-PRV3 10/96

Similar documents
First Alert 1200C Installer Notes M. Leuck

ADEMCO VISTA-10P ADEMCO VISTA-10PSIA Security Systems

VISTA-20PMT. Programming Guide. This control is a certified SIA-compliant control that meets SIA specifications for False Alarm Reduction.

VISTA-100 Commercial Fire & Burglary Partitioned System

Safewatch Pro 3000EN Entrepreneur 3000EN Security Manager 3000EN

Property of Monitronics Inc

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Property of Monitronics Inc

ADEMCO LYNX XL SERIES Security System


ADEMCO VISTA SERIES VISTA-21iP / VISTA-21iPSIA Security Systems

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

ADEMCO 4110XM SECURITY SYSTEM. Installation Guide. N5478V5 7/96 Rev. C

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

FBII Security System. Programming Guide. Version 2.X. N9967PRV3 4/04 Rev. A

LYNX ,QVWDOODWLRQ,QVWUXFWLRQV. ALPHA DRAFT. June 5, 1998 N8889 5/98 OFF AWAY STAY AUX

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

6DIHZDWFK3UR Š 6HFXULW\0DQDJHU

/<1; 6HFXULW\6\VWHP ,QVWDOODWLRQDQG6HWXS*XLGH N8889V1 10/98 OFF AWAY STAY AUX

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

Safewatch Pro 3000 System Manual

Radionics D4112 Program Sheet

VISTA-128FB. Quick Start Guide. Commercial Fire & Burglary Partitioned Security System. with Scheduling.

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

ADEMCO LYNXR Series Security Systems

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide


Tomorrow s technology for today s security needs.

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

FBII Security System. Programming Guide. Version 2.X. N9938PRV3 4/04 Rev. A

SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES ZONE DESCRIPTIONS

GEM-P800 Programming Instructions

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

LYNX Touch Security System

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

AXI LED USER MANUAL (REV. 1.0)

FAI 1OC SECURITY. \\ PROFESSlONAL SECURITY SYSTEMS. This security system can support 6 EOLR wired zones N V2 12/95

CC408. Quick Reference Guide Solution 880

NESS 5000 SERIES DIALLER

2000 Series. Program Entry Guide. Control Panels

ITI Caretaker Basic Commands

RE6100 Series Helix Security and Automation Platform

Security System With Scheduling. User Guide. N5943-8V4 7/04 Rev A

$'(0&2 9,67$ 3DUWLWLRQHG 6HFXULW\ 6\VWHP 8VHU *XLGH N7003V3 5/04 Rev A

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

XR10 Command Processor Panel Programming Guide

USER'S GUIDE FA1220CV. 2-Partition Security System N7003-1V2 7/98

Content. 1. Introduction to the IDS Features Installation and Wiring End-of-Line Resistors/Tamper per Zone...

NetworX Series NX-6 CONTROL PANEL. Installation and Startup

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

HILLS Series LED Code Pad User Manual

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

VISTA-32FBPT. Commercial Fire and Burglary Partitioned Security Systems with Scheduling. User Guide /12 Rev. B

System Programming Guide

CC488. Quick Reference Guide Solution Ultima 880

ADEMCO VISTA-10P ADEMCO VISTA-10PSIA Security Systems

DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel

ADEMCO CONTACT ID REPORTING (revised )

VISTA-50P VISTA-50PUL

User's Manual 5120XM N8031 6/96

/14 Rev. A LYNX Touch L5210 Series

PROGRAMMING INSTRUCTIONS

Control/Communicator Installation Manual

Security System. User Guide for the LED Command Center

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

User's Manual VISTA-40 N7003V1 6/97

ADEMCO VISTA-48 SERIES

0$(6752 0$(6752. Programming Guide. 6 and 10 Zone Alarm Control Panel ,1752'8&7,21 +(;$ 352*5$00,1* 675($0/,1(' 6(&7,21 352*5$00,1* FIGURE 1 FIGURE 2

GEM-P800. Control Panel/Communicator. Installation Instructions

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

Security System. User s Guide for the Text Command Center

VISTA-128BP/VISTA-250BP/ VISTA-128SIA Enhanced Commercial Burglary Partitioned Security System With Scheduling User Guide K5895V5 4/09 Rev C

ADEMCO VISTA-12A ADEMCO VISTA-12E Security Systems

Series. NX-4-EUR Control Panel. Installation manual

Technical Manuals Online! - Keypad Programming. Basic Programming

PROGRAMMING INSTRUCTIONS

Quick Programmer s Manual

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

Table of Contents. All-In-One Wireless Security System V1.3. Programming Guide. Model # MG-6060 / MG-6030

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

INSTALLATION MANUAL & PROGRAM RECORD SHEET

Version 1.03 January-2002 USER S MANUAL

PowerWave-16. Users Operating and Programming Guide Version P/N Rev. B N.A July 2002

Control/Communicator

TABLE OF CONTENTS TABLE OF CONTENTS 1

Solution 6+6 Wireless - AE Installation Manual ISSUE 1.10

NetworX Series NX-4V2 Control Panel Installation and Startup

5HDG\*XDUG5 6HFXULW\6\VWHP 8VHU*XLGHIRU5HDG\*XDUG5. K5481-1V2 10/03 Rev. A OFF STAY ESCAPE AWAY ADD DELETE AUX STAY

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

**** **** A B ARMED FIRE FIRE C D READY OFF AWAY STAY 2 3 MAXIMUM TEST BYPASS PULL INSTANT CODE CHIME. First Alert READY. * 0 # Professional

Power Wave LCD Keypads. Users Operating and Programming Guide Version 2.00

Transcription:

SECURITY SYSTEM 4110DL Programming Form Programming Form Programming Form 4110DL-PRV3 10/96

4110DL PROGRAMMING FORM FIELD FUNCTION [ ] = Default Value SYSTEM OPTIONS (*20-*28) *20 MASTER SECURITY CODE [4] [1] [1] [0] Enter 4 digits, 0-9 (entry of all 4 is mandatory). *21 QUICK ARM ENABLE [0] 0 = no; 1 = yes. If enabled, [#] key can be used instead of security code when arming the system. *22 KEYSWITCH ENABLE [0] 0 = no, 1 = yes *23 FORCE BYPASS FUNCTION [0] 0 = no, 1 = yes. Allows all faulted zones to be bypassed by entering [Security Code] + [Bypass]. Zones that are bypassed by this function will be displayed after the bypass is initiated. *27 AUDIBLE EXIT WARNING [1] 0 = no, 1 = yes. If enabled, beeping will occur during exit time and will change from slow to rapid beeping during last 5 seconds of exit delay (Rev 6 and above only). *28 CONFIRMATION OF ARMING DING [0] 0 = no, 1 = yes. If selected, external sounder will sound for approx. 1 second at end of exit time or at time of kissoff of closing report, if programmed. *29 FIRE SOUNDER TIMEOUT [0] 0 = sounder timeout, 1 = no sounder timeout. Enter 0 if sounder timeout for fire zones is desired (uses time programmed in field *30). *30 ALARM SOUNDER TIMEOUT [1] Enter time for external sounder to shut off after alarm occurs. 0 = no timeout; 1 = 4 min; 2 = 8 min; 3 = 12 min Entry of a number other than one specified will give unpredictable results. -a-

PROGRAMMING HARDWIRE ZONES *31 ZONE 1 RESPONSE TYPE [1] *32 ZONE 2 RESPONSE TYPE [4] *33 ZONE 3 RESPONSE TYPE [3] *34 ZONE 4 RESPONSE TYPE [3] *35 ZONE 5 RESPONSE TYPE [9] *36 ZONE 6 RESPONSE TYPE [7] ZONE TYPES FOR PROGRAMMING FIELDS *31-37 0 = DISABLED (or Undefined) 6 = 24 HR (Silent) 1 = ENTRY/EXIT, Burglary 7 = 24 HR (Audible) 2 = not used 8 = 24 HR (Auxiliary) 3 = PERIMETER, Burglary 9 = FIRE (Fields *35 and *37 only) 4 = INTERIOR/FOLLOWER, 10 = INTERIOR W/DELAY, Burglary (To program, enter # + 10) 5 = TROUBLE BY DAY/ ALARM BY NIGHT, Burglary *37 ZONE 7 RESPONSE TYPE [6] Console Panic: Key B or & #. Only zone types 0, 6, 7, 8, 9 apply. *38 ENTRY DELAY [2] 0 = 0 sec ; 1 = 20 sec; 2 = 30 sec; 3 = 45 sec; 4 = 60 sec; 5 = 90 sec. EXIT Delay = ENTRY Delay + 15 sec *39 ZONE 3 RESPONSE TO OPEN [0] 0 = 400 ms nominal; 1 = 10 ms nominal DIALER PROGRAMMING (*40-*49) In fields 40, 41, 42, enter up to the number of digits shown. Do not fill unused spaces. Enter 0-9; #+11 for ; #+12 for #; #+13 for a pause. *40 PABX ACCESS CODE If fewer than 4 digits entered, exit by pressing (and press 41 if entering next field). To clear entries from field, press 40. *41 PRIMARY PHONE No. If fewer than 12 digits entered, exit by pressing (and press 42, if entering next field). To clear entries from field, press 41. Entry of a number other than one specified will give unpredictable results. -b-

*42 SECONDARY PHONE No. If fewer than 12 digits entered, exit by pressing (and press 43, if entering next field). To clear entries from field, press 42. Seconday phone number can be used for pager. See *49 (Rev 6 and above only). *43 SUBSCRIBER ACCOUNT No. Enter 0-9; #+11 for B; #+12 for C;#+13 for D; #+14 for E; [#+15 for F]. Enter as 4th digit, if 3+1 dialer reporting is to be used. If only 3 digits used, exit by pressing (and press 44, if entering next field). To clear entries from field, press 43. Examples: For Acct No. 1234, enter: 1 2 3 4 For Acct No. B234, enter: #+11 2 3 4 For Acct No. 123, enter: 1 2 3 * *44 REPORT FORMAT [0] 0 = 3+1, 4+1 ADEMCO L/S STANDARD 1 = 3+1, 4+1 RADIONICS STANDARD 2 = 4+2 ADEMCO L/S STANDARD 3 = 4+2 RADIONICS STANDARD 6 or undefined = 4+2 ADEMCO EXPRESS 7 = ADEMCO CONTACT ID REPORTING 8 = 3+1, 4+1 ADEMCO L/S EXPANDED 9 = 3+1, 4+1 RADIONICS EXPANDED *45 PHONE SYSTEM SELECT [0] If Cent. Sta. IS NOT on a WATS line: 0 = Pulse Dial; 1 = Tone Dial If Cent. Sta. IS on a WATS line: 2 = Pulse Dial; 3 = Tone Dial *46 SESCOA/RADIONICS SELECT [0] 0 = Radionics (0-9, B-F reporting); 1 = SESCOA (0-9 only reporting). Select 0 for all other formats. Entry of a number other than one specified will give unpredictable results. -c-

*47 15 SEC DIALER DELAY (BURG) [0] 0 = no, 1 = yes *48 PERIODIC TEST MESSAGE [0] 0 = none, 1 = 24 hrs; 2 = weekly (enter Test Code in field *64) (Initial report is sent 12 hrs. after exiting programming or downloading.) *49 SPLIT/DUAL REPORTING [0] TO PRIMARY PHONE No. TO SECONDARY PHONE No. 0 = All Backup Report Only 1 = Alarms, Restore, Cancel Other Reports 2 = All Reports except Open/Close, Test Open/Close, Test 3 = Alarms, Restore, Cancel All Reports 4 = All Reports except Open, Close, Test All Reports 5 = All Reports (Dual Reporting) All Reports TO PRIMARY PHONE No. To PAGING No. * 6 = All Reports except open/close Alarms, Open/Close, Troubles 7 = All Reports Alarms, Troubles 8 = All Reports Alarms, Open/Close, Troubles (6,7 & 8, Rev 6 and above only) * Can only be used if Primary Reporting is ADEMCO Contact ID. Touch tone codes sent to pager are: 1911 = alarm, 1001 = open, 1002 = close, 1811 = trouble ALARM REPORT CODES (*50-*59) *50 1st DIGIT OF Zn 95, Zn 96 (Keypad Panics) (95) (96) Enter 1-9, 0, B-F as described on next page. An entry of "0" will disable report. 2nd Digit of each (for expanded or 4+2 reporting) is same as for field *57. Zone 95 is Console Silent Panic (Key A or 1 & ). Zone 96 is Console Audible Panic (Key C or 3 & #). Entry of a number other than one specified will give unpredictable results. -d-

*51 ZONE 1 ALARM REPORT CODE *52 ZONE 2 ALARM REPORT CODE *53 ZONE 3 ALARM REPORT CODE *54 ZONE 4 ALARM REPORT CODE *55 ZONE 5 ALARM REPORT CODE *56 ZONE 6 ALARM REPORT CODE *57 ZONE 7 ALARM REPORT CODE (Console Panic: Key B or &#) *58 ZONE 8 ALARM RPT CODE (Duress) *59 ZONE 9 ALARM RPT CODE (Tamper) SYSTEM STATUS REPORT CODES (*60-*68) *60 TROUBLE REPORT CODE *61 BYPASS REPORT CODE *62 AC LOSS REPORT CODE (Sent at random delay up to 1 hour, Rev 6 and above; otherwise sent immediately) *63 LOW BAT REPORT CODE *64 TEST REPORT CODE *65 OPEN REPORT CODE *66 CLOSE REPORT CODE 2nd digit is automatically sent as the user number if expanded or 4+2 reporting is selected. *68 CANCEL REPORT CODE TO PROGRAM REPORT CODES FOR ALARM, SYSTEM STATUS, & RESTORE (*51 *74) For 3+1 or 4+1 Standard Format: Enter a code in the first box: 1-9, 0, B, C, D, E, or F. Enter "#+10" for 0, "#+11" for B, "#+12" for C, "#+13" for D, "#+14" for E, "#+15" for F. For Expanded or 4+2 Format: Enter codes in both boxes (1st and 2nd digits) for 1-9, 0, or B-F, as described above. For Ademco Contact ID Format: Enter any digit (other than "0") in the first box, to enable zone to report. This is an "enabling" code only and is not the actual report sent to the central office. Entries in the second box will be ignored. An entry of "0" in the first box for any report format will disable a report. An entry of "0" in the second box will result in automatic advance to the next field when programming. To send "0" as a digit, you must enter # + 10. Examples: For Code 3 (1 Digit), enter: 3 0 For Code 32 (2 Digits), enter: 3 2 For Code B2 (Hex) enter: #11 2 RESTORE REPORT CODES (*69-*93) *69 GROUP RESTORES for TROUBLE, [0] RF LOW BATTERY, BYPASS 0 = no (report for each restore], 1 = yes (report after all zones restored) Note: "1" not applicable to Contact ID reporting. *70 ALARM RESTORE REPORT CODE 2nd digit is automatically sent as the 2nd digit of the zone alarm report code programmed in *50-*59, if expanded or 4+2 reporting is selected. *71 TROUBLE RESTORE REPORT CODE -e-

*72 BYPASS RESTORE REPORT CODE *73 AC RESTORE REPORT CODE *74 LOW BAT RESTORE REPORT CODE *93 REPORTS PER ARMED PERIOD [0] 0 = 10 max total alarm + alarm restores; 1 = Unlimited DOWNLOAD INFORMATION (*94-*97) *94 DOWNLOAD PHONE No. Enter up to 12 digits, 0-9. Enter # + 11 for "*", # + 12 for "#", # + 13 for 2 sec. pause. Do not fill unused spaces. If fewer than 12 digits entered, exit field by pressing * (and press 95, if entering next field). To clear entries from field, press *94*. *95 RING DET COUNT FOR DOWNLOADING [0] [0=Disable Station Initiated Download]; 1-14=number of rings (1-9, #+10=10, #+11=11, #+12=12, #+13=13, #+14=14); 15=answering machine defeat (#+15=15) *96 INITIALIZES DOWNLOAD ID AND SUBSCRIBER ACCOUNT No. FOR FIRST TIME DOWNLOAD (THIS MUST BE DONE BEFORE FIRST DOWNLOAD. ONCE INITIALIZED, DO NOT RE-ENTER ANOTHER SUBSCRIBER ACCOUNT No. MANUALLY. THIS WOULD VOID THE *96 COMMAND.) *97 ZEROS ALL PROGRAM FIELDS TO EXIT PROGRAM MODE (*98 or *99) Press *98 or *99 if exiting programming, or next field number if continuing. *98 EXITS PROGRAMMING MODE Prevents re-entry by: [Master Code] + [Code] key + [0]. *99 EXITS PROGRAMMING MODE Allows re-entry by: [Master Code] + [Code] key + [0]. -f-

4110DL-PRV3 10/96 ALARM DEVICE MANUFACTURING CO. A DIVISION OF PITTWAY CORPORATION 165 Eileen Way, Syosset, New York 11791 Copyright 1996 PITTWAY CORPORATION