QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

Similar documents
ARROWHEAD ALARM PRODUCTS Ltd. 344b Rosedale Rd, Albany, Auckland. Ph Fax v1.0

Power Wave. 8 Zone Control Communicator. Crow Electronic Engineering P/L. Ver:8.54. Installation & Programming Guide.

Elite Version. 8 Zone Control Communicator. Installation & Programming Guide. Proudly Designed and Manufactured in New Zealand

16 ( Ver: Installation & Programming Guide. Power Wave 16 Zone Control Communicator. Crow Electronic Engineering (Australia) Pty Ltd

Installation & Programming Guide

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Power Wave Zone Alarm Panel V8.5. Installation Manual

(Updated Defaults) (Covers Ver: 8.64 and above)

Installation & Programming Guide. ELITE S LITE Version. (8/16 Zone Control Communicator) Arrowhead Alarm Products Ltd

Voice Board. Installation and Programming Guide. Runner 4/8,PowerWave 4/8/16 &, Elite64. Add-on Board For Storing Recorded Voice Messages

Wolf Guard Touch Keypad GSM Wireless alarm system User s Manual

INSTRUCTIONS CONTROL PRODUCTS INITIAL SET-UP. Innovative Technologies in Custom Electronic Design & Manufacturing

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

NESS 5000 SERIES DIALLER

CHEAT SHEET: SPECTRA V2.1

Automatic Phone-Out Home Monitoring Systems

Version 1.03 January-2002 USER S MANUAL

Installation & Programming Guide

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

INSTALLATION MANUAL PC56O. Version 1.OA

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

CC408. Quick Reference Guide Solution 880

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

User Manual (LS-GSM-006)

MK9 series CarePhone. Installers Mauual

Intelligent Wireless GSM Alarm System

rvm4c Installation Guide Remote Video Module

Elite S Version 8-16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

PowerWave-16. Users Operating and Programming Guide Version P/N Rev. B N.A July 2002

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Contents. Glossary

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

GSM RFID VOICE Alarm System

MOBILE CALL GSM Alarm System User s Manual

Solution Ultima Series Operators Manual ISSUE 1.00

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

Control Panel. Operators Manual TO SUIT AS216 KEYPAD. AS216-OM-6.2. Advanced Digital Controls

PERMACONN PM1030 Includes DI300. Installation Manual

Auto Dialer. Manual E-921APQ E-921GPQ

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00


Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

System Introduction. 1.1 Specifications S E C T I O N 1

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

Sentry 4 Zone Alarm Panel User Manual

System. For a better understanding of this product, please read this user manual thoroughly before using it.

MiniAlarm Plus. Model MA-5000

Solution 844 Operators Manual ISSUE 1.10

RUNNER 8/64. 8/64 Zones Control Panel. Program Summary Guide

Installation & Operations Manual

ADE Gen4. Speech Dialler Engineering Information. Description. Features

CC488. Quick Reference Guide Solution Ultima 880

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

TRX MAINS CONNECTION DIAGRAM

QUICK USER MANUAL. Alarm Control Panel. The full user manual and other manuals are available on

VAP304 PRO INSTALLATION & OPERATION MANUAL

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

User s Information Guide R2A

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

Quick Installation Manual LED 99-Zone Autodial Wireless Alarm System

Ultra-8D. ControlPanel. Operators Manual. Advanced DigitalControls CP108-0M-V1

Solution Ultima 862 Operators Manual ISSUE 1.10

Control/Communicator Installation Manual

Content. 1. Introduction to the IDS Features Installation and Wiring End-of-Line Resistors/Tamper per Zone...

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

Intruder alarm system Operating Instructions

ACP10 & ACP50 Security Systems

DYGIZONE GJD910 Lighting Controller & Enunciator

Fusion Alarm System USER GUIDE

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

LS800S Intruder Alarm System. Engineering Manual

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Security Alarm System Owner's Guide 8 sector CDS Dialler 8-24 sector Control Dialler 8-24 sector Control Securitel Version 1.0 lcopm.

PiSector GSM Cellular Wireless Alarm System

External Wireless Sounder

Refrigerator/Freezer Guard Models VM605, VM605E. Property Guard Models VM610, VM610E. Temperature Monitor and Alarm

ITI Caretaker Basic Commands

EC-P Zone Intruder Alarm System

Destiny Destiny Owners Manual

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

AXI LED USER MANUAL (REV. 1.0)

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

MODEL 5100 BROADBAND ALARM COMMUNICATOR INSTALLATION & USER S GUIDE PRODUCT ID #

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

2G & 3G GSM Door Contact Alarm

MEDI-CALL UNIT INSTALLATION MANUAL. Medi-Call V2.0 - V2.7 Installation Manual

SA 2650 Kit User Manual

IDS816 User Manual H Issued January 2009

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

M800, M800iD Plus, M1000 and M3000. User's Guide

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

Solution 6+6 Wireless - AE Installation Manual ISSUE 1.10

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

Proudly Designed and Manufactured in New Zealand. By Arrowhead Alarm Products Ltd

ICP-CC408 ICP-CC408 EN. Control Panel. User s Guide

Memcom Emergency Telephone

Transcription:

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

PROGRAMMING STARTS Entering Installer mode If you want to get into program mode press <PROGRAM> followed by your installer code, default set to 000000 and <ENTER> to confirm. Exiting Installer Mode Press the <PROGRAM> button, then <ENTER>. Changing/Adding user codes The panel has the ability to have up to 100 user codes. They can have a 1 to 6 digit code. User Codes are stored in at Address 1, slots 1 to 100. To change codes you must be in Installer or Client mode, then press <PROGRAM> <1> <ENTER> then the slot you wish to change i.e. <1> and then <ENTER>, the keypad will flash back the existing code (default code is 1 2 3). Now key in your new code i.e. (4 5 6) and press <ENTER> the new code will be then flash back. P 1 E 1 E [ ][ ][ ][ ][ ][ ] E (This is the master code default code= 123) P 1 E 3 E [ ][ ][ ][ ][ ][ ] E P 1 E 5 E [ ][ ][ ][ ][ ][ ] E P 1 E 7 E [ ][ ][ ][ ][ ][ ] E P 1 E 9 E [ ][ ][ ][ ][ ][ ] E Changing Installer code There is only one installer code, this is for you to remember. As default it is 000000. You must be in Installer mode to change the code, press <PROGRAM> <25> <ENTER> <1> <ENTER> (then put in your new code) and <ENTER>. P 25 E 1 E [ ][ ][ ][ ][ ][ ] E P 1 E 2 E [ ][ ][ ][ ][ ][ ] E P 1 E 4 E [ ][ ][ ][ ][ ][ ] E P 1 E 6 E [ ][ ][ ][ ][ ][ ] E P 1 E 8 E [ ][ ][ ][ ][ ][ ] E P 1 E 10 E [ ][ ][ ][ ][ ][ ] E Changing Entry delay s Zone 1 is set at 20 seconds by default. This is how long the panel gives you to get in and disarm it after a sensor has been tripped. Each sensor has its own delay from 0 to 9999 seconds. If you have to pass a sensor to get to the keypad then it should have a delay. In Installer Mode press <PROGRAM> <144> <ENTER> (then select the zone you wish to change 1-8) and <ENTER> (then put in the new time 0-9999) and <ENTER>. P 144 E 1 E [ ][ ][ ][ ] E P 144 E 2 E [ ][ ][ ][ ] E (zone 1 default delay is 20 seconds). (zone 2 default delay is 0 seconds). Changing Exit delay This is how long you have to get out of the house before the panel goes into alarm mode. You can have from 0 to 255 second selected below. In Installer Mode press <PROGRAM> <60> ENTER <1> <ENTER> (then put in the new time 0-255) and <ENTER>. P 60 E 1 E [ ][ ][ ] E (the default time is 30 seconds). Output Reset Times This is how long the sirens will sound before turn off automatically. Time is in seconds. In Installer Mode press <PROGRAM> <40> <ENTER> (then the output you wish to change 1 or 2) and <ENTER> (now put in the new reset time 0-9999) and <ENTER>. P 40 E 1 E [ ][ ][ ][ ] E P 40 E 2 E [ ][ ][ ][ ] E (output 1 default reset time is 300 seconds). (output 2 default reset time is 300 seconds). Page 2

TESTING When you have finished the programming options, a quick test is required to confirm all hardware and software is working correctly. Run through the steps below and tick the box if it operates successfully. Make sure no one is moving around the house, as this could affect the test. 1. The keypad should not have any zone lights on. The ready light should be on steady. Are all the lights right? yes if no there could be a wiring problem check your work. 2. Get someone else to walk in front of the sensors, the corresponding zone 1 or 2 should come on. Do they come on at the right time? yes if no there could be a wiring problem check your work. 3. Now test all the user codes. Start by typing in user code 1 followed by enter, the keypad should start beeping as it arms, then type it in again, the keypad should go quiet as it disarms. Repeat this test for all user codes. Do all of the codes arm and disarm the panel? yes if no go back and check the user code slots, to see weather the right codes has been entered. 4. Next to press the ARM button, to see if there is enough time to get out of the house, before the exit delay beeps stop. Can you get out before the beeps stop? yes if no you will need to extend the exit delay. 5. Now with the panel ARMED see if you can get back inside to the keypad and disarm the alarm before the sirens go off. Can you disarm before the sirens go off? yes if no you will need to increase the entry delay times. 6. The final test is to make sure the sirens and strobe go off after the entry delay has finished. So arm the alarm, wait for the beeps to stop then move in front of a sensor, the keypad should start beeping again and as soon as the entry delay is up the sirens and strobe will go off, once checked enter a user code to disarm and turn of the sounders. Does the external siren work? yes Does the external strobe work? yes Does the internal siren work? yes if no to any of these check wiring and polarity of devices. The alarm panel is now ready for general use Are you happy with the installation? yes Sign here. Date. / / Page 3

DIALLER SETUP - FOR MONITORING STATION Your Elite S-Lite Controller is equipped with an on board dialler, capable of communicating in contact id. If you are required to connect to a central monitoring station you will need to complete the following steps. Contact a monitoring station of your choice, they will issue you an account number and telephone number. Name of monitoring station Contact phone number Your Account number [ ][ ][ ][ ] Telephone number 1 [ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ] Telephone number 2 [ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ] (this is optional) Step 1: Step 2: Step 3: Step 4: Connect across the incoming phone line between the street and the first jack point. Enable the dialler. In Installer Mode press <PROGRAM> <175> <ENTER> <1> <ENTER> (then turn ON option 1) and <ENTER>. P 175 E 1 E 1 E Account number. In Installer Mode press <PROGRAM> <62> <ENTER> <1> <ENTER> (then put in the 4 digit account number) <ENTER>. i.e. P 62 E 1 E 1234 E (the new account code would be 1234) Phone number 1, In Installer Mode press <PROGRAM> <181> <ENTER> <1> <ENTER> (now key in your given phone number 1) and <ENTER>. I.e. P 181 E 1 E 095551234 E (the new phone number 1 would be 095551234) Phone number 2, In Installer Mode press <PROGRAM> <181> <ENTER> <2> <ENTER> (now key in your given phone number 2) and <ENTER>. I.e. P 181 E 2 E 095554321 E (the new phone number 2 would be 095554321) Step 5: Prepare for dialler test. First we will temporarily disable sounders. In Installer Mode press <PROGRAM> <25> <ENTER> <9> <ENTER> <1> <2> <ENTER> (outputs 1 & 2 have been disabled until an Arm cycle has taken place). P 25 E 9 E 1 2 E Step 6: Step 7: Step 8: Exit program mode by pressing and holding <PROGRAM> Testing. Press the <ARM> button the exit delay will start. When it stops walk in front of each detector, then go back to the keypad to see if LED s 1 & 2 are now flashing and the keypad is squealing. As soon as the entry delay has finished, the panel should start dialling out. You wont be able to hear it dial out, but if you pick up a phone in the house it should not have a dial tone. Leave the panel for about 2 minutes then key in a user code i.e. <1 2 3> followed by <ENTER>. The panel should now be disarmed. Confirming. Now contact the monitoring station and ask them if they received 3 different monitoring messages from your account code. They should be: Alarm activation on zone 1. Alarm activation on zone 2. Alarm restored. Dialler Setup is Complete Page 4

DIALLER SETUP - FOR PERSONAL MONITORING If you don t want your alarm to be monitored by a security company, but still wish to know if any activations occurs, then the Domestic Dial option could be for you. If a phone number on your Elite S-Lite Controller s is set to Domestic Dial, when an activation occurs that number will be called and siren tone will be played down the line to you. Then you need to acknowledge it by pressing the # key on the phone. Telephone number 1 [ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ] Telephone number 2 [ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ] Telephone number 3 [ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ] Telephone number 4 [ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ] With the Elite S-Lite you can report both Formats Contact ID and Domestic Dial on the same job. As each phone number is setup independently. Step 1: Step 2: Connect across the incoming phone line between the street and the first jack point. Enable the dialler. In Installer Mode press <PROGRAM> <175> <ENTER> <1> <ENTER> (then turn ON option 1) and <ENTER>. i.e. P 175 E 1 E 1 E Step 3: Phone number 1 to 8, In Installer Mode press <PROGRAM> <181> <ENTER> <1-8> <ENTER> (now key in your phone number) and <ENTER>. i.e. P 181 E 1 E 021555123 E (the new phone number 1 would be 021555123) Step 4: Phone number 1 to 8 Reporting Format. In Installer Mode press <PROGRAM> <182> <ENTER> <1-8> <ENTER> (now turn ON option 2) and <ENTER>. i.e. P 182 E 1 E 2 E (phone number 1 is now set to Domestic Dial). Step 5: Maximum Dial Attempts. Each phone number set to Domestic Dial will need dial attempts changed. In Installer Mode press <PROGRAM> <184> <ENTER> <1-8> <ENTER> <3> <ENTER>. i.e. P 184 E 1 E 3 E (phone number 1 now has maximum dial attempts set to 3). Step 6: Reporting Options. Each phone number set to Domestic Dial will need 2 reporting options turned off. So in Installer Mode press <PROGRAM> <176> <ENTER> <4> <ENTER> <0> and <ENTER>. Then <PROGRAM> <176> <ENTER> <5> <ENTER> <0> and <ENTER>. i.e. P176 E 4 E 0 E (mains fail, reporting on domestic dial has been turned off). i.e. P176 E 5 E 0 E (mains restore, reporting on domestic dial has been turned off). Step 7: Step8 : Exit program mode by pressing and holding <PROGRAM> Testing. With the phone learnt into slot 1 on hand, Arm the panel and wait for the exit delay to finish. Then walk in front of a PIR, the entry delay should start, followed by the sirens sounding. Disarm the panel to make the sirens stop. The phone should now be ringing, answer it and listen. A siren tone should play for 3 seconds on 2 seconds off. While the tone is off press and hold the # key to acknowledge the call, the alarm panel will then hang up. (if the # key will not hang up the panel try a different key) Page 5

HARDWARE CONFIGURATION Screw PCB down in these points. PCB fits here CUT THIS SUPPORT OFF POP OUT CABLE CLAMP FOR MAINS LEAD. Cable Entry Point 17 volt AC power leads BATTERY GOES HERE WIRE 230V MAINS IN HERE. INSIDE VEIW OF PLASTIC CABINET Removing back from keypad. E16LED KP End view of Keypad Carefully slide a flat blade screwdriver into slots to remove back. Page 6

5 Year Warranty Thank you for purchasing another quality Arrowhead Product. We guarantee to replace or repair Arrowhead Manufactured product found to be faulty due to defective materials or workmanship for a period of 5 years from date of purchase. The customer shall as soon as practicable after the discovery of any such defect or fault, return the goods or defective parts thereof, to Arrowhead Alarm Products. Freight to and from our stores is your care. The company shall not be liable for any direct or consequential loss or damage attributed to the fault. Nor shall the company be liable for any personal injury of any kind attributable to the fault. The customer will keep the company indemnified against any such claim. Any attempt by the customer to repair the goods with out written permission by the company could void the Warranty. Page 7

TELEPHONE WIRING OPTION 1: Standard analogue line SILICONE FILLED CRIMPS ESL CONNECTION DIAGRAM PHONE LINE OFF THE STREET TELEPHONE WIRING OPTION 2: with high speed internet (broadband) SILICONE FILLED CRIMPS PHONE LINE OFF THE STREET WITH ADSL ENABLED ADSL FILTER NOT SUPPLIED IN KIT LINE ADSL MODEM DSL008 ADSL LINE FILTER PHONE HOUSE PHONES In Lin Out Lin Dat ELITE S-LITE V908.12 AC AC Red Blk 17VAC TELEPHONE WIRING OPTION 3: with Voice over IP System IP-MODULE NOT SUPPLIED IN KIT Internet Router Internet Connection VoIP phone lines will Not work with the Alarm System. IP-MODULE KEYPAD 1 RECEIVER Clk Neg Pos Gnd 12V 1 2 3 4 Outputs Gnd 12V 1 C 2 3 C 4 Tmp Gnd 2k2 2k2 12 Volt SLA Battery P N 230V AC Input EXTERNAL Optional Radio Receiver Connects here: RX-16 MF349 v090618 (303, 433 & 915MHz) INTERNAL PIR 2 PIR 1 Lin Dat Clk Neg Pos 12 0V C D Keypad Terminal Block ANT ON 1 2k2 E16LED KP 2k2 0v 12v EOL TAMPER EOL RELAY EOL TAMPER LED STROBE SIREN SS-1C SATELLITE SIREN PIEZO SIREN 0v 12v EOL TAMPER EOL RELAY Zone 1 Passive Infra-Red Detector Zone 2 Passive Infra-Red Detector RESISTOR COLOUR CODES: 2K2 = = RED, RED, RED, GOLD. 4K7 = = YELLOW, VIOLET, RED, GOLD. 8K2 = = GREY, RED, RED, GOLD.