Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU

Similar documents
Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU

Fire dampers. For diverse applications

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Prodotti > Protezione dal fuoco e dal fumo > Serranda tagliafuoco > Type FK-EU

K*, R* Ventilation grilles

Type TDF-SilentAIR WITH VERY LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH FIXED AIR CONTROL BLADES

Type EK-EU FOR MECHANICAL SMOKE EXTRACT SYSTEMS AND AS AN ADDITIONAL SUPPLY AIR INLET, ALSO FOR NATURAL SMOKE AND HEAT EXHAUST SYSTEMS

Kezdőlap > Termékek > Tűz és füst elleni védelem > Füstmentesítő csappantyúk > Típus EK-EU. Típus EK-EU

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Design ceiling swirl diffusers > Type ADD. Type ADD

Homepage > Products > Control systems > Demand-based room control with X-AIRCONTROL > Sensors > X-SENS X-SENS

Homepage > Products > Decentralised ventilation Systems > Vertical devices > Type FSL-V-ZUS. Type FSL-V-ZUS

Ceiling diffusers. Type DLQL

Type VDW WITH LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH INDIVIDUALLY MANUALLY ADJUSTABLE AIR CONTROL BLADES

Ceiling swirl diffusers

Ceiling swirl diffusers

Air distribution for clean rooms. Clever and flexible.

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

Units for suspended ceilings

Homepage > Prodotti > Sistemi di ventilazione decentralizzata > Dispositivi verticali > Type FSL-V-ZUS. Type FSL-V-ZUS

Type RM-O-3-D. Duct smoke detector used to prevent smoke from spreading through the ducts of ventilation and air conditioning systems

Compact. Efficient. TROX.

Dual certification! Air handling units for potentially explosive atmospheres

Units for suspended cei lings

Compact. Efficient. TROX.

Fire damper ETPR Instructions for Installation, Operation and Maintenance 10/2016

Decentralised ventilation

Air distribution systems. Opticlean OC-Q...

SECTION AIR DUCT ACCESSORIES

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

Circular Fire Damper Cartridge

Chilled Ceiling Elements

ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB

Passive chilled beams

VL120. Multi blade smoke evacuation damper 120' C-NT-V24-A 01/2016

Life Safety Dampers Selection and Application Manual

Fan Coil Unit CULTRA

DACC Health Sciences Building Air Handler Assessment/Study

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

Intumescent Fire Dampers

Air distribution systems. Rectangular displacement outlet VA-RN... with adjustment device VA-RV...

Decentralised ventilation units

Air distribution systems. Opticlean OC-Q... DS 4136 E /1

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

Resolair 62 and 66. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 1,200 4,300 m³/h

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

Ceiling displacement outlet non-adjustable Q-DN... adjustable Q-DV...

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

Ceiling air diffuser INDULTHERM INDULTHERM-e

Rectangular displacement outlet VA-RN... with adjustment device VA-RV...

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

ECOSMART TWINFANS. (EST-X/R/B) 1 phase, Direct Drive, Run & Standby For External, Roof Mounted and Internal use Installation and Maintenance

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

ACCUBLOC high performance Heat Recovery

Smoke Master SMIA Compact pressurisation and smoke exhaust system

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

COOLflow 4E PRODUCT RANGE

EASYAIR COMPACT DEVICE THE EASY WAY OF AIR HANDLING.

FEATURES AND BENEFITS

TUNNEL FANS STANDARD AND HOT SMOKE

Decentralised Ventilation Systems

Orion-Opus LØV-R with Sirius

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

BSK-RPR Fire Damper. Additional operating instructions according to

Bevent Rasch BSKC6. - Fire /06/17

Fire protection unit

Ceiling air diffuser INDULTHERM INDULTHERM-e

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking

CONDOR. Supply air ceiling QUICK FACTS

INSTRUCTIONS. Duct Mount Kit Q900. Description. Operation

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

KLIMA Active Chilled Beams

IFE Level 3 Certificate in Passive Fire Protection

DUCT SYSTEMS CHAPTER 6

Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS

Prescriptive Requirement for Smoke Control

ECOSMART XTRACTOR. (ESX-X/R/B) 1 phase, Direct Drive For External, Roof Mounted and Internal use Installation and Maintenance.

Smoke extraction duct of sheet steel

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

Orion-PTV LØV-R with Sirius

Able to respond to smoke alarms for the protection of escape routes and areas with sleeping risk (ADB)

Orion-LØV LØV-R with Sirius

THE SMOKE MUST GO. Consulting - Project Planning - Supply - Installation - Service

Filter Technology from A to Z. Filter units and filter elements from TROX

Actionair. Hot/Shield PTC. BROCHURE UPDATED* High Operating Temperature Smoke Management and Fire Dampers

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC

Cooling Strip Model SPB

FIRE & SMOKE DAMPERS. Meeting tomorrow's requirements for fire and smoke protection today.

WHHR Midi & Midi Lite

Installation Manual: PAD100-DUCTR Analog Addressable Duct Detector

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

DUCT SYSTEMS CHAPTER 6

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

SERIES BM. Concealed Fan Convector

Transcription:

Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES Small circular fire damper for the isolation of duct penetrations between fire compartments, available in ten nominal sizes Nominal sizes: 100 315 mm Low differential pressure and sound power level Optional stainless steel casing or powder-coated casing for increased corrosion protection Can also be used as an air transfer unit Integration into the central BMS with TROXNETCOM Universal installation options Optional equipment and accessories Electric actuator 24 V/230 V Release temperature 72/95 C Duct smoke detector RM-O-3-D

APPLICATION Application Fire dampers of Type FKRS-EU, with CE marking and declaration of performance, for the isolation of duct penetrations between fire compartments in the event of a fire To prevent the propagation of fire and smoke through ductwork to adjacent designated fire compartments Special characteristics Declaration of performance according to Construction Products Regulation Classification to EN 13501-3, up to EI 120 (v, h, i o) S Building inspectorate licence Z-56.4212-991 for fire resistance properties Complies with the requirements of EN 15650 Tested to EN 1366-2 for fire resistance properties Hygiene complies with VDI 6022 part 1 (07/2011), VDI 3803 (10/2002), DIN 1946 part 4 (12/2008), and EN 13779 (09/2007) Corrosion protection according to EN 15650 in connection with EN 60068-2-52 Closed blade air leakage to EN 1751, class 3 Casing air leakage to EN 1751, class C Low differential pressure and sound power level Any airflow direction Integration into the central BMS with TROXNETCOM e o Classification Class of performance to EN 13501-3, up to EI 120 (v, h, i o) S e o Nominal sizes 100, 125, 150, 160, 180, 200, 224, 250, 280, 315 L: 400 mm DESCRIPTION Variants With fusible link

With spring return actuator With cover grilles both ends as air transfer unit with general building inspectorate licence: Z-19.18-2128 Parts and characteristics Dry mortarless installation into solid walls and ceiling slabs, lightweight partition walls, fire walls, and shaft walls using an installation block Installation with wall face frame on the face of solid walls Release temperature 72 C or 95 C (for use in warm air ventilation systems) Approved installation orientation from 0 to 360 Attachments Limit switch for damper blade position indication Spring return actuator for 24 V AC/DC or 230 V AC supply voltage Network module for the integration with AS-i or LON networks Accessories Circular installation block ER Square installation kit TQ Wall face frame WA Installation kit GL Cover grille Flexible connectors Extension piece Useful additions Duct smoke detector RM-O-3-D Duct smoke detector with airflow monitor RM-O-VS-D Construction features Rigid circular casing suitable for push fitting into cut circular holes without additional drilling and chiselling being required Spigot connections with lip seal on both ends, suitable for ventilation ducts according to EN 1506 and EN 13180 plus non-standard but commercial nominal

sizes 180, 224 and 280 Suitable for the connection of flexible connectors or cover grilles The release mechanism is accessible and can be tested from the outside One inspection access panel Remote control with spring return actuator Materials and surfaces Casing: Galvanised sheet steel Galvanised sheet steel, powder-coated RAL 7001 Stainless steel 1.4301 Damper blade: Special insulation material Special insulation material with coating Other components: Damper blade shaft made of galvanised steel or stainless steel Plastic bearings Seals of elastomer The construction variants with stainless steel or powder-coated casing meet even more critical requirements for corrosion protection. Detailed listing on request. Standards and guidelines Construction Products Regulation EN 15650:2010 Ventilation for buildings Fire dampers EN 1366-2:1999 Fire resistance tests for service installations Fire dampers EN 13501-3:2010 Fire classification of construction products and building elements EN 1751:1999 Ventilation for buildings Air terminal devices Maintenance

The functional reliability of the fire damper must be tested at least every six months; this has to be arranged by the owner of the ventilation system; functional tests must be carried out in compliance with the basic maintenance principles stated in EN 13306 and DIN 31051. If two consecutive tests, one 6 months after the other, are successful, the next test can be conducted one year later. A functional test involves closing the damper blade and opening it again; with a spring return actuator this can be done via remote control Fire dampers must be included in the regular cleaning schedule of the ventilation system. For details on maintenance and inspection refer to the installation and operating manual TECHNICAL INFORMATION FUNCTION Construction with fusible link Functional description In the event of a fire, fire dampers shut automatically to prevent the propagation of fire and smoke through ductwork to adjacent designated fire compartments. In the event of a fire, the damper is triggered at 72 C or at 95 C (use in warm air ventilation systems) by a fusible link. The release mechanism is accessible and can be tested from the outside. Construction with spring return actuator Functional description The spring return actuator enables the motorised opening and closing of the damper blade; it can be activated by the central BMS. In the event of a fire, the damper is triggered thermoelectrically at 72 C or 95 C (use in warm air ventilation systems). As long as power is supplied to the actuator, the damper blade remains open. If the supply voltage fails, the damper closes (power off to close). Motorised fire dampers can be used to shut off ducts. The torque of each actuator is sufficient to open and close the damper blade even while the fan is running. The spring return actuator is fitted with limit switches that can be used for capturing the damper blade position. Schematic illustration of FKRS-EU with fusible link

1 Casing 2 Fusible link 3 Damper blade with seal 4 Inspection access (12 mm) 5 Lip seal 6 Handle with interlock and damper blade position indicator 7 Release mechanism Schematic illustration of FKRS-EU with spring return actuator 1 Casing 2 Temperature sensor 3 Damper blade with seal 4 Inspection access (12 mm) 5 Lip seal 6 Spring return actuator 7 Thermoelectric release mechanism

Schematic illustration of the FKRS-EU as air transfer unit, with fusible link and cover grille 1 Casing 2 Fusible link 3 Damper blade with seal 4 Inspection access (12 mm) 5 Cover grille 6 Handle with interlock and damper blade position indicator 7 Release mechanism

TECHNOLOGY Nominal sizes Casing length Volume flow rate range Differential pressure range 100 315 mm 400 mm Up to 770 l/s or up to 2770 m³/h Up to 1500 Pa Operating temperature At least 0 50 C ** Release temperature Upstream velocity* 72 C or 95 C (for warm air ventilation systems) 8 m/s with standard construction; 10 m/s with spring return actuator * Data applies to uniform upstream and downstream conditions for the fire damper ** Temperatures may differ for units with attachments

QUICK SIZING Volume flow rate at differential pressure Δpst < 35 Pa L WA [db(a)] 25 35 45 25 35 45 Nominal size V mm l/s m³/h 100 22 35 43 79 126 157 125 40 65 87 144 234 315 150 70 105 150 252 378 540 160 80 125 180 288 450 648 180 105 165 235 388 587 847 200 140 210 295 504 756 1062 224 170 245 345 612 882 1242 250 215 315 445 774 1134 1602 280 280 405 570 1008 1458 2052 315 360 525 735 1296 1890 2646 The Easy Product Finder allows you to size products using your project-specific data. You will find the Easy Product Finder on our website. SPECIFICATION TEXT Circular fire dampers for the isolation of duct penetrations between fire compartments. Tested for fire resistance properties to EN 1366-2, with CE marking and declaration of performance according to the Construction Products Regulation. Ready-for-operation unit, which includes a fire-resistant damper blade and a release mechanism. For mortar-based installation and dry mortarless installation into solid walls and ceiling slabs, mortar-based installation into non-load-bearing solid walls with flexible ceiling joint, mortar-based and dry mortarless installation into lightweight partition walls with cladding on both sides, lightweight fire walls and lightweight shaft walls, and dry mortarless installation on the face of solid walls. For dry mortarless installation in lightweight partition walls with metal support structure and flexible ceiling joint; for dry mortarless installation in solid walls and ceiling slabs when using a fire batt; in lightweight partition walls with metal support structure and cladding on both sides. Casing length 400 mm, for the connection to ducts made of non-combustible or combustible materials. Thermal or thermoelectric release at 72 C or 95 C (warm air ventilation systems).

Constructions with spring return actuator for opening and closing the fire damper independent of the nominal size and even while the ventilation system is running, e.g. for a functional test. Simple construction for dry mortarless installation with installation kit: ER, TQ, GL, WA Special characteristics Declaration of performance according to Construction Products Regulation Classification to EN 13501-3, up to EI 120 (v, h, i o) S e o Building inspectorate licence Z-56.4212-991 for fire resistance properties Complies with the requirements of EN 15650 Tested to EN 1366-2 for fire resistance properties Hygiene complies with VDI 6022 part 1 (07/2011), VDI 3803 (10/2002), DIN 1946 part 4 (12/2008), and EN 13779 (09/2007) Corrosion protection according to EN 15650 in connection with EN 60068-2-52 Closed blade air leakage to EN 1751, class 3 Casing air leakage to EN 1751, class C Low differential pressure and sound power level Any airflow direction Integration into the central BMS with TROXNETCOM Materials and surfaces Casing: Galvanised sheet steel Galvanised sheet steel, powder-coated RAL 7001 Stainless steel 1.4301 Damper blade: Special insulation material Special insulation material with coating Other components: Damper blade shaft made of galvanised steel or stainless steel Plastic bearings Seals of elastomer Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-07-26 TROX GmbH

Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU The construction variants with stainless steel or powder-coated casing meet even more critical requirements for corrosion protection. Detailed listing on request. Technical data Nominal sizes: 100 to 315 mm Casing length: 400 mm Volume flow rate range: up to 770 l/s or 2770 m³/h Differential pressure: up to 1500 Pa Operating temperature: at least 0 50 C ** Release temperature 72 C or 95 C (for use in warm air ventilation systems) Upstream velocity: 8 m/s with standard construction; 10 m/s * with spring return actuator Note: * Data applies to uniform upstream and downstream conditions for the fire damper ** Temperatures may differ for units with attachments ORDER CODE Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-07-26 TROX GmbH

Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU Type FKRS-EU Fire damper Accessories 1 No entry: none Construction No entry: standard construction 1 Powder-coated casing 2¹ Stainless steel casing 7 Coated damper blade ER TQ WA GL Circular installation block Square installation kit Wall face frame Installation kit for flexible ceiling joint Accessories 2 1 7 Powder-coated casing and coated damper blade 2 7¹ Stainless steel casing and coated damper blade W² With fusible link 95 C (only for use in warm air ventilation systems) Country of destination No entry: none S0 AS Attachments Z00 ZL08 DE Germany Other destination countries upon request Nominal size [mm] ¹ Only up to DN 200 when a fire batt system is used ² W can be combined with all constructions listed under 100 125 150 160 180 200 224 250 280 315 Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-07-26 TROX GmbH

Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU Type FKRS-EU Fire damper Construction No entry: standard construction 1 Powder-coated casing 7 Coated damper blade 1 7 Powder-coated casing and coated damper blade Country of destination DE Germany Other destination countries upon request Nominal size [mm] 100 125 150 160 180 200 224 250 280 315 Accessories 2 AA Attachments Z00 Z03 TROX GmbH Online-Services Service-Hotlines Heinrich-Trox-Platz D-47504 Neukirchen-Vluyn Tel.: +49 (0)2845 202-0 Fax: +49 (0)2845 202-265 Order-Status (My TROX NET) TROX Academy Catalogue Download Your contact partner Online fault report BIM Sales Germany and technical consulting +49 (0)2845 202-0 Contact Technical service +49 (0)2845 202-400 Contact Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-07-26 TROX GmbH