Michael J. Caron, Test Engineer. Lee R. Senne, Test Technician. Kent L. Erickson, Dynamics Division Manager

Similar documents
Engineering Report Vibration Test for Intertek Testing Services Prepared by Approved by 9725 Girard Avenue South Minneapolis, MN 55431

SmartSensor 105 & Advance NEMA External Ice

Vibration tests on a TNAML Luminaire

/Mar/2014 Rev A

OPERATION MANUAL Model 8011 & mA

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

OCTOBER 4, 2013 C.O.C #213041B VITA 46 VPX CONNECTORS QUALIFICATION TESTING HYPERTRONICS CORPORATION

TABLE OF CONTENTS. 1.0 INTRODUCTION Scope References Test Specimen Description Summary 1

ENVIRONMENTAL TEST REPORT

OPERATION MANUAL MODEL & ACCELEROMETER

MODEL 834M1 ACCELEROMETER

New Sensing products of Meggitt Group. Moscow - October the 23 rd

ISO/TS TECHNICAL SPECIFICATION

CA 134. Piezoelectric accelerometer. IECEx NEPSI TIIS KGS. » From the Vibro-Meter product line» Vibration monitoring over a wide temperature

WYLE LABORATORIES, INC. Huntsville Facility

23" PANEL MOUNT INDUSTRIAL MONITOR REVISION C PRODUCT RELIABILITY TEST REPORT

MODEL 4000A & 4001A ACCELEROMETER

PERFORMANCE EVALUATION TEST REPORT. Rendered to: GREENFIELD MANUFACTURING COMPANY. PRODUCT: Hanger Screws

Qualification Test Report LC Duplex Adapter For LC Cutouts

CERTIFICATE of QUALITY TEST

OPERATION MANUAL MODEL 8102 ACCELEROMETER

OPERATION MANUAL MODEL 805 ACCELEROMETER

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

DRAFT TANZANIA STANDARD

OPERATION MANUAL MODEL 4610 ACCELEROMETER

Sunlight Supply, Inc.

Test Report. Appliance EMF Testing

17" UNIVERSAL MOUNT INDUSTRIAL MONITOR REVISION E, F & G PRODUCT RELIABILITY TEST REPORT

TABLE OF CONTENTS. 1.0 INTRODUCTION Scope References Test Specimen Description Summary 3

WH-1404, Rev. Feb 97

NATIONAL TECHNICAL SYSTEMS

halt & hass systems

Effect of Foundation Embedment of PWR Structures in SSI Analysis considering Spatial Incoherence of Ground Motions

Intrinsically Safe Transmitters, Option Code 2n

APPLICATION FOR OSHPD SPECIAL SEISMIC CERTIFICATION PREAPPROVAL (OSP)

OPERATION MANUAL MODEL 3255A ACCELEROMETER

Mar11 Rev B

LASER DIODE NX8316XC nm FOR LONG HAUL 2.5 Gb/s InGaAsP MQW-DFB LASER DIODE TOSA DESCRIPTION APPLICATION FEATURES

Operations Manual. Motion Detector Module Model ZS10

Fibrlok II 2529 Universal Optical Fiber Splice

Environment Test Report

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

Mar11 Rev C

CNBOP-PIB Standard Fire Protection

1.0 INTRODUCTION 2.0 CLASSIFICATION CRITERIA

In-Situ Roll Balancing A Revolutionary Method for Improving Dryer Section Performance

Test Report to AS/NZS :2015. Report No. T160402_S

1N4001 THRU 1N4007 1N4001 THRU 1N SILICON RECTIFIER. Features:

1022 R/T Remote Monitor

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

OPERATION MANUAL MODEL mA

DUST TEST REPORT. :Gold Apollo Co., Ltd. Company Model Name :A27. Date of Received :APR. 19, 2006 Date of Tested :APR. 19, 2006

GP2Y1010AU0F. Compact Optical Dust Sensor. Description. Compliance. Applications. Features GP2Y1010AU0F. 1. Compliant with RoHS directive (2002/95/EC)

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES

Hazardous Area Ringdown Telephone

Product Training Module: Inertial Measurement Unit 6-D Motion Variant 6DF Series. Copyright 2013 Honeywell International Inc. All rights reserved.

OPERATION MANUAL MODEL 805M1 ACCELEROMETER

LASER DIODE NX7637BF-AA

Report No 288/ Part 1 of 2 This report consists of 22 pages. Maxitone ZAMT Type A Addressable Sounder. See Assessment Summary for details

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

Warning Caution. Safety Precautions (Be sure to read these precautions before using our products.)

Warranty Registration

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

SLIP RESISTANCE TESTING OF ENDURO-MESH PANEL

Product Specification JUL07 Rev. F. 1. Scope : 2. Applicable Documents: 3. Requirements : 1 of Contents. 2.1 AMP Specifications :

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

The information contained in this document is the property of Meggitt Sensing Systems and is proprietary and/or copyright material.

July 22, Stewart Audio Inc. Brian Mccormick Po Box 4058 Mountain View, CA File SV17764 / Project 09CA34798

TEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota

NX8601BF-AA. Data Sheet R08DS0109EJ0100 Rev.1.00 Apr 19, 2013 LASER DIODE DESCRIPTION FEATURES

PERFORMANCE TEST REPORT. Rendered to: EVERBLOCK SYSTEMS, LLC. PRODUCT: Modular Block Product

HM-4201-RTCM High-Temp Real Time Clock Module

MODEL ACCELEROMETER

Test Report Garvan Enterprises Limited

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

condition monitoring WP4086 Condition Monitoring System The WP4086 CMS System surveys vibrations with up to 8 external accelerometers

FUNDERMAX GMBH FIRE TEST REPORT

ARLINGTON COUNTY, VIRGINIA

WP4086 Condition Monitoring System

USB 3.0 Plug & Receptacle

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

805QS Pressure Switch-Transmitter

QUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY

AN10943 Decoding DTMF tones using M3 DSP library FFT function

ISO INTERNATIONAL STANDARD. Rotating shaft vibration measuring systems Part 1: Relative and absolute sensing of radial vibration

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

15203B 25203B 35203B Uniaxial Biaxia Triaxial

PQS Independent type-testing protocol

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

RENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

HALT & HASS Systems.

FEBL8511_REFBOARD_Manual-01 ML FC. REFERENCE BOARD Manual for UV Sensor (QFN)

We Identify and S.T.O.P. Your Noise Problems

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT

Vibration Services. Centre Spatial de Liège. Advanced Technologies Space Instruments Test Services. Analysis. Test. Model Adaptation.

Transcription:

Engineering Report 49820-1 Vibration Test for Crystal Group Inc. Prepared by Michael J. Caron, Test Engineer Lee R. Senne, Test Technician Approved by Kent L. Erickson, Dynamics Division Manager This document shall not be reproduced, except in full, without express written authorization of Environ Laboratories LLC. In the event this document is provided to the customer in any format that may be modified or copied in any part, no modifications, changes, or additions to this report, nor any summary hereof, shall be permitted in any manner. All original content of this document shall be considered one entire report. Environ Laboratories LLC shall not be liable to the customer or to any third party for unauthorized modification or misuse of this document. Transmittal of technical data (as applicable): ITAR/EAR related content; this document may contain technical data within the definition of the International Traffic in Arms Regulations (ITAR) or Export Administration Regulations (EAR) and is subject to the export controls law of the U.S. Government. Transfer of this data by any means to a foreign person or foreign entity, whether in the United States or abroad, without an export license, ITAR exemption, or other approval from the U.S. Department of State or Bureau of Industry and Security is prohibited. 9725 Girard Avenue South Minneapolis, MN 55431 952-888-7795 FAX 952-888-6345 800-826-3710 www.environlab.com Testing Cert 1719.01

Revision history Revision Total number of pages Date Description -- 9 August 18, 2014 Original ENVIRON LABORATORIES LLC Page i of i

Prepared for: Crystal Group Inc. Attention: Mr. Brent Sievers Test dates Start: 12/19/2013 Completion: 12/19/2013 Environ test number: 49820-1 Purchase order number: 489273 Purchase date: 12/12/2013 Vibration Test 1.0 Abstract 1.1 Object Subject one Thin Client Custom 1U Embedded Server to a Vibration Test as specified in the customer email dated December 9, 2013, which references MIL-STD-810G, dated October 31, 2008, Method 514.6, as requested in Crystal Group Inc. purchase order 489273, dated December 12, 2013. 1.2 Conclusions Upon completion of the Vibration Test the test unit remained intact and appeared to have incurred no visible evidence of damage or degradation as a result of the test. The test unit was operated and monitored by a representative of Crystal Group, inc. throughout the course of testing. 2.0 Unit(s) tested Table 2-1: Units tested Manufacturer Device Model/part number Crystal Group Inc. One (1) Thin Client Custom 1U Embedded Server Rugged Thin Client Serial number 13111262 The results of this test apply only to the units identified in this Engineering Report by device identifier and model / part number, or serial number. ENVIRON LABORATORIES LLC Page 1 of 9

3.0 Test requested Subject one Thin Client Custom 1U Embedded Server to a Vibration Test as specified in the customer-supplied email dated December 10, 2013. Random background Frequency (Hz) Power spectral density (g²/hz) 10 0.008646 100 0.03353 300 0.03353 2000 0.003353 In addition, the following sinusoidal tones were superimposed over the random background: Frequency (Hz) Excitation (g peak) 4.3 0.1094 17.2 1.72 34.4 2.5 51.6 1.5 Overall acceleration: Duration: 5.495 grms 1 hour in each of three mutually perpendicular axes ENVIRON LABORATORIES LLC Page 2 of 9

4.0 Instrumentation, procedure, and results 4.1 Instrumentation All instrumentation is calibrated regularly by instruments directly traceable to the National Institute of Standards and Technology, and in accordance with MIL-I-45208A, ANSI/NCSL Z540.3-2006, and ISO/IEC 17025: 2005. Table 4-1: Instrumentation list Equipment Number Description Manufacturer Model Number Last Calibration Due Calibration Range 204-537 Signal Conditioner / Power Supply Endevco 104/109 8/26/2013 8/26/2014 1 Hz to 20 khz 480-124 Accelerometer PCB Piezotronics 352A73 1/7/2013 1/7/2014 0 to 1000 g; 2 Hz to 10 KHz 480-141 Accelerometer PCB Piezotronics 352C41 7/17/2013 7/17/2014 0 to 500 g; 0.5 Hz to 10 KHz 480-174 ICP Accelerometer PCB Piezotronics 352C34 9/12/2013 9/12/2014 0.5 Hz to 10000 Hz 503-139 Vibration Exciter Unholtz-Dickie 560 N/A N/A 5 to 2000 Hz; 6000 force lbs 503-157 Vibration Amplifier Unholtz-Dickie MA130-70-2 N/A N/A 5 to 2000 Hz 503-168 Vibration Shaker Unholtz-Dickie T509 N/A N/A 5 to 3000 Hz; 7000 ft-lbs 503-215D Vibration Controller Vibration Research Corporation VR9500 1/29/2013 1/29/2014 N/A ENVIRON LABORATORIES LLC Page 3 of 9

4.2 Procedure The test unit was connected for operation and secured to a fixture plate, which was coupled to the vertically oriented exciter. A control accelerometer was cemented to the fixture plate, and the operational test unit was subjected to testing in the Z-axis. The test unit was next secured to the horizontally oriented slip plate, and then finally rotated 90 degrees on the slip plate, and testing was conducted in the Y and X-axes, respectively. 4.3 Results Upon completion of the Vibration Test, the test unit remained intact and appeared to have incurred no visible evidence of damage or degradation as a result of the test. The test unit was operated and monitored by a representative of Crystal Group, inc. throughout the course of testing. The test unit was returned to Crystal group, Inc. Test setup photographs and vibration graphs follow. ENVIRON LABORATORIES LLC Page 4 of 9

Photograph 4-1: Test unit identification label Photograph 4-2: Test unit secured to the fixture plate and ready for testing in the Z-axis. The control accelerometer is visible, cemented to the fixture plate. Applied motion is up-and-down as this photograph is viewed. ENVIRON LABORATORIES LLC Page 5 of 9

Photograph 4-3: Test unit secured to the slip plate and ready for testing in the Y-axis. The control accelerometer is visible, cemented to the slip plate. Photograph 4-4: Test unit secured to the slip plate and ready for testing in the X-axis. The control accelerometer is visible, cemented to the slip plate. Applied motion is front-to-back as this photograph is viewed. ENVIRON LABORATORIES LLC Page 6 of 9

Customer: Crystal Group, Inc. Job#: 49820 Data: C:\VibrationVIEW\Data\2013-12\421322013Dec19-1040-0009.vrd Test: C:\VibrationVIEW\Profiles\49820.vrp Data stored on Dec 19, 2013 11:41:24 Crystal Group inc. - Z-Axis Small Rugged Thin Client - End of Test Acceleration Spectral Density 1x10 0 Acceleration Spectral Density (G²/Hz) 1x10-1 1x10-2 1x10-3 1x10-4 1x10-5 1x10-6 R1 BR Control 5 10 100 1000 2000 Frequency (Hz) Test level schedule: Duration Level 1) 1:00:00 100 % (SoR) ** Test started Dec 19, 2013 10:40:33, running for 1:00:51 ** Current level: 1, running at 100 % for 1:00:00 of 1:00:00 ENVIRON LABORATORIES LLC Page 7 of 9

Customer: Crystal Group, Inc. Job#: 49820 Data: C:\VibrationVIEW\Data\2013-12\421322013Dec19-1303-0008.vrd Test: C:\VibrationVIEW\Profiles\49820.vrp Data stored on Dec 19, 2013 14:04:22 Crystal Group inc. - Y-Axis (long)small Rugged Thin Client - End of Test Acceleration Spectral Density 1x10 0 1x10-1 Acceleration Spectral Density (G²/Hz) 1x10-2 1x10-3 1x10-4 1x10-5 1x10-6 R1 BR Control 5 10 100 1000 2000 Frequency (Hz) Test level schedule: Duration Level 1) 1:00:00 100 % (SoR) ** Test started Dec 19, 2013 13:03:37, running for 1:00:45 ** Current level: 1, running at 100 % for 1:00:00 of 1:00:00 ENVIRON LABORATORIES LLC Page 8 of 9

Customer: Crystal Group, Inc. Job#: 49820 Data: C:\VibrationVIEW\Data\2013-12\421322013Dec19-1410-0008.vrd Test: C:\VibrationVIEW\Profiles\49820.vrp Data stored on Dec 19, 2013 15:11:47 Crystal Group inc. - X-Axis (lat) Small Rugged Thin Client - End of Test Acceleration Spectral Density 1x10 0 1x10-1 Acceleration Spectral Density (G²/Hz) 1x10-2 1x10-3 1x10-4 1x10-5 1x10-6 R1 BR Control 5 10 100 1000 2000 Frequency (Hz) Test level schedule: Duration Level 1) 1:00:00 100 % (SoR) ** Test started Dec 19, 2013 14:10:57, running for 1:00:50 ** Current level: 1, running at 100 % for 1:00:00 of 1:00:00 ENVIRON LABORATORIES LLC Page 9 of 9