LSFG-8 LOW SOUND & SLSFG-10 SUPER LOW SOUND TOWER FEATURES

Similar documents
Engineering Specifications for HXV Closed Circuit Hybrid Cooling Tower

Series 5000 Industrial Modular Cooling Tower. Series 5000 Cooling Tower. engineering Data

Fibreglass reinforced polyester (FRP) water collection basin with sloping base and smooth internal finish with rounded corners for easy cleaning.

Michigan State University Construction Standards. COOLING TOWERS Page SECTION COOLING TOWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION COOLING TOWERS

Efficient, Long Lasting Evaporative Condensers

SECTION COOLING TOWERS

Reliable products with long-term, low cost of ownership

Series 1500 Cooling Tower Specification

QuadraFlow Cooling Tower

Un-Used Series CXV Evaporative Condenser

POWER TOWER SERIES Fiberglass Construction 45 to 540 Tons

CROSSFLOW FILM FILL PACKAGE COOLING TOWER. Number TYH SERIES LOW NOISE - ENERGY SAVINGS. Thermal-Cell Sdn Bhd ( M)

CROSSFLOW REPLACEMENT FILL KITS. Replacement Fill Kits Specifically Designed for All Types of Crossflow Cooling Towers (BAC, Marley, etc.

NEWIN Centrifual Fan Forced Draft Cooling Tower Product Introduction

/ Aquatower Fiberglass Cooling Tower /

A. Codes and Standards that are Standard at the University:

VTL Open Cooling Towers... B98. Benefits... B100. Construction Details... B102. Custom Features and Options... B103. Accessories...

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

ENGINEERING DATA AND SPECIFICATIONS. Marley Aquatower FIBERGLASS CROSSFLOW COOLING TOWER

Baltimore Aircoil RCF CLOSED CIRCUIT COOLING TOWERS. ...because temperature matters COUNTERFLOW INDUCED DRAFT

Product Introduction...E11. Benefits...E13. Construction Details...E15. Custom Features & Options...E19. Accessories...E23. Structural Support...

ICT Cooling Towers. Stainless Steel Basins and Fiberglass Casings Available. Advanced Features In Induced Draft, Counterflow Towers.

Compass Series Open Cooling Towers

CXVB Evaporative Condenser TABLE OF CONTENTS E112 ENGINEERING DATA CXVB EVAPORATIVE CONDENSERS E144 STRUCTURAL SUPPORT CONSTRUCTION DETAILS

Bulletin 241B. Mark owned by the Cooling Technology Institute

What is a Closed circuit Cooling Tower (CCT)?

Closed Circuit Cooling Towers

Evaporative Condensers

Mr. GoodTower Service Center

Aquatower STEEL COOLING TOWER. engineering data and specifications

Product Introduction...D85. Benefits...D87. Construction Details...D89. Custom Features & Options...D91. Accessories...D93. Engineering Data...

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Maximum Capacity and Highest Quality to the. Lowest Shipping Costs! Engineered to Deliver the. Worldwide Market - with the.

DESCRIPTION WATER COOLING TOWER TAS/TASF (*) SERIES

STAINLESS STEEL EVAPORATIVE CONDENSER

Product Introduction...E35. Benefits...E37. Construction Details...E39. Custom Features & Options...E41. Accessories...E44. Engineering Data...

DESCRIPTION OF COOLING TOWERS SERIES TAT

Presenters. Brett Alexander. Mihir Kalyani. Troy Reineck

XLP2 Evaporative Condensers

Product Introduction...D33. Benefits...D35. Construction Details...D37. Custom Features & Options...D39. Accessories...D41. Engineering Data...

Privately held company

Product Introduction...D9. Benefits...D11. Construction Details...D13. Custom Features & Options...D15. Accessories...D18. Engineering Data...

What is Cooling S.Sen

COOLING TECHNOLOGY INSTITUTE

Temptek Auxiliary Equipment

Section (CSI ) I-Series Drum & Tube (04/23/10) Indirect-Fired Heating & Ventilating

ENGINEERING AND SPECIFICATIONS. Marley MC FLUID COOLER

Operation & Maintenance of Cooling Tower

Evaporative Condensers

Closed Circuit Hybrid Cooling Towers. Product Introduction...E61. Benefits...E63. Construction Details...E65. Custom Features & Options...

DIVISION 15 MECHANICAL

hinged tops or hinged doors.

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL

Direct Fired Heater Model AD Specification

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

SECTION STEAM CONDENSATE PUMPS

Since its founding in 1976, EVAPCO,

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

CTI Sponsored Educational Program

Evaporative Cooling products

Table of Contents INTMPE OVERVIEW ANSI B73.1 ANSI B73.1M API-610

Bulletin 241-E Metric C E R T I F I E D E N I S O Mr. GoodTower

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Available in Capacities from 208 to 2,050 Ammonia Tons!

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

How about Savings in Time, Money, Energy and Longer Life?

Industrial Fans & Blowers

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

SB Series Brazed Plate Heat Exchanger Installation Manual

AUXILIARY EQUIPMENT FOR ALL YOUR NEEDS

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

BECAUSE TEMPERATURE MATTERS: MAINTAINING COOLING TOWERS

Cooling Tower Designs

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

96% COMMERCIAL INDUSTRIAL HEATER. Condensing Gas Water Heating System. Thermal Efficiency

INDIRECT GAS-FIRED AIR HEATER

ENGINEERING DATA AND SPECIFICATIONS. MH Fluid Cooler

AT, MT & ES Series Super Low Sound Fan

Maintain. a TOWER of POWER. Part One How to. Don t let out of site, out of mind prevent you from keeping cooling towers running efficiently

1600 Series Rotating Suction Screen

Closed Circuit Coolers Technology for the Future, Available Today

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

1.1 This section applies to air handling units for HVAC Systems.

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

AMERICAN COOLAIR CORPORATION. Greenhouse Ventilation Systems. Farm Products Division

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

JCseries EVAPORATIVE CONDENSER. engineering data

RCF Closed Circuit Cooling Tower RCC Evaporative Condenser OPERATION & MAINTENANCE MANUAL

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

SPRING cooling tower parts reference guide OEM PARTS FOR MARLEY COOLING TOWERS AND FLUID COOLERS

FAN IMPELLERS & FAN CASINGS

Lenntech. Tel Fax Engineering Data & Specifications

Bid Opening Date: 1:30 PM, Thursday, November 16, 2017 (Not Changed)

WA Series Super Low Noise Space Saving Energy Saving

C13-Series Engineering Guide

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

Smarter Washing Solutions AGGST RM 150

Transcription:

The

Leaders in All-Fiberglass Cooling Towers REYMSA s success is the result of 35 years of experience in cooling towers. We have been putting ideas into action by researching and developing the latest technology, therefore we are proud to offer the Low Sound Series for sound sensitive applications. Keep the peace and reduce your impact on others, use Low Sound Tower Series from REYMSA. THERMAL PERFORMANCE CERTIFIED BY THE COOLING TECHNOLOGY INSTITUTE REYMSA s complete line of LSFG-8 & SLSFG-10 models towers are certified by the CTI in accordance to Standard STD-. LSFG-8 LOW SOUND & SLSFG-10 SUPER LOW SOUND TOWER FEATURES All FRP Seamless One piece construction. Corrosion resistant. UV Protection for extended life. Fiberglass-Reinforced-Polyamide adjustable pitch blades. One piece seamless basin design. Fixed distribution nozzles with variable flow rates. Self extinguish PVC fill & PVC drift eliminator. Low and Super Low sound. Sickle fan blades for reduced sound. Low RPM motor. Triple-pass PVC air inlet louvers. No moving internal parts. Single or multiple fan configurations with common sump. Light weight. Stable thermal composition. Minimal maintenance.

ALL FIBERGLASS SUPERIOR ADVANTAGES Corrosion resistant. Major longevity, life expectancy of 30 plus years. No risk of water leakage, a unique seamless, one piece construction. Better appearance, aesthetically superior to other cooling towers. UV (Ultra Violet) inhibitor Gel-Coat applied on the Exterior and Interior surfaces gives superior protection against harsh environmental conditions and aggressive chemical treatment. FRP is not affected by the corrosive sediments collected in the basin. Most metal tower manufactures (galvanized and stainless steel) require frequent draining, flushing and cleaning of the sediment to try to prevent corrosion. Greater resistance to a wide spectrum of ph s, total dissolved solids, chlorides and sulfates from the water treatment. Capable of enduring a much higher concentration of chlorides in the water than "any" steel (galvanized and /or stainless) cooling tower. REYMSA all fiberglass cooling tower is a perfect partner for Pulse Power non-chemical water treatment applications that handle up to a 400 ppm chloride concentration in the recirculation water. These application would mean more cycles of concentration and less water loss due to bleed off or blow-downs.

DIRECT DRIVE FAN MOTOR FEATURES Eliminates the use of pulleys, belts, bearing and couplings and the associated cost, time and inconveniences of maintaining them. Increases reliability and greatly reduces risk of failure, with only one moving part. REYMSA uses the best fan on the market, manufactured using cast aluminum hubs and adjustable pitch air foil sickle blades molded with fiberglass reinforced polyamide, which is spark and corrosive resistant, able to resist high vibration levels and high temperatures. Ambient operating air temperatures may fluctuate from 50 F to 250 F. Fan Motors: REYMSA exclusively uses Marine rated motors in all models cooling towers, Marine rated motors exceed the characteristics of the standard Cooling Tower Duty motors. REYMSA Fan Motors are NEMA Premium Efficient, TEFC, 1.15 service factor, 100% cast iron construction for SEVERE DUTY, INVERTER DUTY, and MARINE DUTY applications, EPOXY PAINT, inpro/ seal vbx bearing isolators on both ends of the shaft, brass drain and breather, 6-60 hz variable torque.

THE MOST RELIABLE HOT WATER DISTRIBUTION SYSTEM Hot water manifold manufactured of PVC with welded branches tested at 100 psig., to assure reliability and prevent water leakages that affect the tower efficiency, due to wearing of union gasket as other manufacturers do. NON CLOGGING SPRAY NOZZLES Fixed, non-clogging orifice nozzles, 2 ½", N.P.T., largest in the market, manufactured in ABS plastic, able to handle up to 180 F water temperature, with interchangeable internal devices so that water is efficiently and uniformly distributed across the entire fill surface. Nozzle body has threaded connection and it is easy to remove. 2½" N.P.T. ABS-Spray Nozzles with interchangeable internal devices HIGHEST SURFACE TO VOLUME RATIO PVC FILL FOR SMALLER FOOTPRINT By having the highest specific surface area ft2/ft3, our fill provides the most surface area for heat transfer for all HVAC and most Industrial applications. The PVC compounds used in our fill have outstanding resistance to weather and are nearly impervious to chemical degradation by alkali, acids, grease, fats, oils and biological attack. Also has excellent fire rating due to its self-extinguishing characteristics and meets or exceeds Cooling Technology Institute (CTI) PVC materials standard 136.

EASILY REMOVABLE AIR INLET LOUVERS Our triple pass PVC air inlet louvers are designed to minimize direct sunlight to the water, reduce splash out and reduce noise while having low pressure drop that results in less fan motor energy consumption. The potential of algae growth is reduced, therefore reducing water treatment and maintenance cost. Additional characteristics are its durability by being corrosion-free and impervious to chemical attacks. PVC is specially formulated for UV and fire resistance, non-combustible and self extinguishing. EASY MAINTENANCE AND CLEANING ACCESS Wide and easily accessible for monitoring or cleaning. Removable Access Door Removable Air inlet Louvers A COMPANY FOUNDED IN 19 WHO REALLY UNDERSTANDS THE IMPORTANCE OF HAVING SATISFIED CUSTOMERS TO BUILD LONG TERM RELATIONSHIPS ALL COOLING TOWERS ARE ASSEMBLED AND TESTED PRIOR TO SHIPMENT

EASY AND ECONOMICAL ASSEMBLY AND INSTALLATION Assembly is simply bolting the fan cylinder to the one piece, body/basin section. There are no gaskets required. The reduced footprint of our induced draft, counterflow design requires less structural base support and frequently less piping than the crossflow towers. OPTIONAL EQUIPMENT Access ladder. Stainless steel handrail. Stainless steel non-skid catwalk. Vibration switch. Sound / air deflectors. Automatic Sand Filtration System Basin Sweeper piping for water filtration. Basin heaters and control panel. Electric water level controller and valve. Fire Sprinkler System.

OPTIONAL DESIGNS WITH CUSTOMIZED COMPONENTS OR COLORS FOR SPECIAL APPLICATIONS Special fills for industrial applications with bigger flutes, vertical design or for higher than 130 F water temperature. Tower casing construction with flame retardant resin according to the ASTM- E Standard. Special Colors, Designs or Configurations LOW & SUPER LOW SOUND MODELS SINGLE FAN DOUBLE FAN QUADRUPLE FAN LSFG-8-60610 to LSFG-8-812125 SLSFG-10-606103 to SLSFG-10-812125 LSFG-8-714203 to LSFG-8-816215 SLSFG-10-714203 to SLSFG-10-816215 LSFG-8-1414403 to LSFG-8-1615 SLSFG-10-1414403 to SLSFG-10-1615

CONSTRUCTION DETAILS 1 2 3 4 5 6 7 8 10 11 9 12 13 1. Fan Section 2. Plenum 3. Drift Eliminator 4. Lifting Eyes 5. Spray Nozzle Manifold 6. Hot Water Inlet 7. Body Section 8. Cellular Fill 9. Air Inlet Louvers 10. Basin Section 11. Water Make up 12. Cold Water Outlet 13. Mounting Holes 14. Overflow (back side) 15. Drain (back side) 16. Purge (back side)

LSFG-8 SERIES MODEL LSFG-8-606103 LSFG-8-606105 LSFG-8-606175 LSFG-8-707103 LSFG-8-707105 LSFG-8-707175 LSFG-8-708103 LSFG-8-708105 LSFG-8-708175 LSFG-8-708110 LSFG-8-709103 LSFG-8-709105 LSFG-8-709175 LSFG-8-709110 LSFG-8-709115 LSFG-8-808103 LSFG-8-808105 LSFG-8-808175 LSFG-8-808110 LSFG-8-808115 LSFG-8-810103 LSFG-8-810105 LSFG-8-810175 LSFG-8-810110 LSFG-8-810115 LSFG-8-810120 LSFG-8-812105 LSFG-8-812175 LSFG-8-812110 LSFG-8-812115 LSFG-8-812120 LSFG-8-812125 LSFG-8-714203 LSFG-8-714 LSFG-8-714275 LSFG-8-816203 LSFG-8-816 LSFG-8-816275 LSFG-8-816210 LSFG-8-816215 LSFG-8-822275** LSFG-8-822210** LSFG-8-822215** LSFG-8-822220** LSFG-8-827275** LSFG-8-827210** LSFG-8-827215** LSFG-8-827220** LSFG-8-1414403 LSFG-8-1414405 LSFG-8-1414475 LSFG-8-1603 LSFG-8-1605 LSFG-8-1675 LSFG-8-1610 LSFG-8-1615 LSFG-8-1622475 LSFG-8-1622410 LSFG-8-1622415 LSFG-8-1622420 LSFG-8-1627475 LSFG-8-1627410 LSFG-8-1627415 LSFG-8-1627420 ENGINEERING DATA DIMENSIONS WEIGHT *NOMINAL L W H SHIPPING OPERATING TONS 167 167 167 175 175 175 127 127 127 1890 1890 1890 2553 2553 2553 4674 4674 4674 9349 9349 9349 4415 4415 4415 5624 5624 5624 95 95 95 95 95 95 10818 10818 10818 27 27 27 79 97 111 87 111 129 90 117 136 150 92 121 141 155 189 93 122 158 194 128 153 171 211 242 134 151 176 224 259 280 171 218 252 186 245 290 318 389 312 345 432 507 306 357 454 529 346 438 509 369 4 566 624 761 624 690 864 1013 613 714 909 1057 * A Nominal TON is defined as 3 GPM of water cooled from 95 F to 85 F with a 78 F entering wet bulb. ** Modular sections to be assembled for higher tonage requirements. Minimum two modules. Contact your Rep for proper selection. 1. All dimensions, weights and capacities are in inches, pounds and gallons. Physical dimensions of each tower are approximate and are subject to change. 2. All double and quadruple models have double fittings and connections.

SLSFG-10 SERIES MODEL SLSFG-10-606103 SLSFG-10-606105 SLSFG-10-606175 SLSFG-10-707103 SLSFG-10-707105 SLSFG-10-707175 SLSFG-10-708103 SLSFG-10-708105 SLSFG-10-708175 SLSFG-10-708110 SLSFG-10-709103 SLSFG-10-709105 SLSFG-10-709175 SLSFG-10-709110 SLSFG-10-709115 SLSFG-10-808103 SLSFG-10-808105 SLSFG-10-808175 SLSFG-10-808110 SLSFG-10-808115 SLSFG-10-810103 SLSFG-10-810105 SLSFG-10-810175 SLSFG-10-810110 SLSFG-10-810115 SLSFG-10-810120 SLSFG-10-812105 SLSFG-10-812175 SLSFG-10-812110 SLSFG-10-812115 SLSFG-10-812120 SLSFG-10-812125 SLSFG-10-714203 SLSFG-10-714 SLSFG-10-714275 SLSFG-10-816203 SLSFG-10-816 SLSFG-10-816275 SLSFG-10-816210 SLSFG-10-816215 SLSFG-10-822275** SLSFG-10-822210** SLSFG-10-822215** SLSFG-10-822220** SLSFG-10-827275** SLSFG-10-827210** SLSFG-10-827215** SLSFG-10-827220** SLSFG-10-1414403 SLSFG-10-1414405 SLSFG-10-1414475 SLSFG-10-1603 SLSFG-10-1605 SLSFG-10-1675 SLSFG-10-1610 SLSFG-10-1615 SLSFG-10-1622475 SLSFG-10-1622410 SLSFG-10-1622415 SLSFG-10-1622420 SLSFG-10-1627475 SLSFG-10-1627410 SLSFG-10-1627415 SLSFG-10-1627420 ENGINEERING DATA DIMENSIONS WEIGHT *NOMINAL L W H SHIPPING OPERATING TONS 167 167 167 175 175 175 127 127 127 1890 1890 1890 2553 2553 2553 4674 4674 4674 9349 9349 9349 4415 4415 4415 5624 5624 5624 95 95 95 95 95 95 10818 10818 10818 27 27 27 82 94 105 93 111 132 97 117 140 159 101 122 148 171 194 103 124 153 200 108 131 161 191 222 240 134 171 200 238 265 298 182 214 256 248 304 350 401 329 387 458 495 345 406 483 528 369 437 519 406 491 598 677 778 660 776 921 1000 690 812 5 1057 * A Nominal TON is defined as 3 GPM of water cooled from 95 F to 85 F with a 78 F entering wet bulb. ** Modular sections to be assembled for higher tonage requirements. Minimum two modules. Contact your Rep for proper selection. 1. All dimensions, weights and capacities are in inches, pounds and gallons. Physical dimensions of each tower are approximate and are subject to change. 2. All double and quadruple models have double fittings and connections.

R www.reymsa.com R REYMSA COOLING TOWERS, INC. 1 World Trade Center, Millenium Industrial Park Laredo, Tx. 78045 Phone (210) 579-4837 Fax (210) 745-1513 Toll Free Number 1-866-445-2043 sales@reymsa.com