The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

ID50series. intelligent fire alarm panels

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

ID3000 intelligent. fire alarm panel

ID2000. intelligent fire alarm panel

ID3000 intelligent. fire alarm panel

ZXSe Range Data Sheet

intelligent fire alarm ID60series panels

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

DXc Control Panels. DXc1. DXc2. DXc4. Single Loop Control Panel, 230Vac, 2 sounder circuits. Dims 260 x 390 x 147mm (H x W x D)

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

ID2000. operating manual

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide

Components Brochure DX CONNEXION

user manual Document No , Revision 03 November 2015

Document No Issue 4 user manual

Advanced FireAlarm Panel 1-4Loop

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

Intelligent Security & Fire Ltd

The EN54 Part 2 & 4 Fire System

Consultant Specification AGILE Wireless Fire Detection System

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

The EN54 Part 2, 4 and 13 Fire System

Installation, Operating and Maintenance Manual

System 800 Addressable Fire Detection & Alarm System

Excel-EN Conventional Fire Control Panel

Vigilant MX4428 Fire Alarm System

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

Laptop / PC Programming Manual

Document No Issue 02 operation & installation manual. ZXr-A ZXr-P

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Intelligent addressable fire alarm control panel

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Intelligent 2 & 4 Loop Fire Alarm Control Panels

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

SOLO Single Loop Addressable Fire Control Panel

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

OPERATION AND INSTALLATION MANUAL

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL

GE Security Vigilant Fire & Life Safety. Easy. V-Series Intelligent Life Safety Systems

HART XL High Sensitivity Smoke Detection

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Product Catalogue. Intelligent Control Equipment for Life Safety. Issue 1

Touch Screen 1 loop Addressable Fire Alarm Panel

Product Data Sheet. Remote Terminals. Features:

Written by: A.C. Amended by G.G. Checked by: JBJ/PB Approved by:jbj

C E R T I F I C AT LPCB I O N B O A R D P R E V E N T L O S S. Cooper Fire Systems

Addressable and Conventional Fire Protection

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Intelligent Single Loop Fire Alarm Control Panel

Conventional & Twin-wire Fire System

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

ZSC100 Gas Detection and Alarm System Controller

Sita200plus. 200detectors. Single loop analogue addressable System

AFP-300/400 OPERATORS MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3

Fire control panel detect 3004 plus and accessories

DCS-100. intelligent damper control & monitoring system

AFP-400 Analog Fire Panel MEA E. City of Chicago Class 1: 1291E Class 2: 1792E GENERAL FEATURES. A Pittway Company

MX4428. Addressable Fire Alarm System. Features. Advantages & Options

INTELLIGENT FIRE ALARM CONTROL PANEL

TrueAlarm Fire Alarm Systems

Intelligent Security & Fire Ltd

Solution F2. Fire Alarm Control Panels one step ahead.

FC700A Fire detection control unit

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

Addressable Fire Alarm Control Panel

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

5000 INSTALLATION GUIDE

Surveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above

HART XL High Sensitivity Smoke Detection

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

5000 Series Rack Panels

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

TX7004. Intelligent Addressable Fire Alarm Control Panel Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

The Kentec driver connects to the Kentec Syncro range of fire detection panels. Available for Commander and ObSys.

Precept Marine Control Panel Application Guide

Intelligent Security & Fire Ltd

HS-5100, HS-5200, HS-5400 ANALOGUE ADDRESSABLE CONTROL PANELS. User Manual. Approved Document UI-ELAN-02 Revision 03

SmartTerminal AS7240. Installation and Operation Guide MAN2990-1

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

good things in small packages

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

System 57. An advanced World of intelligent gas detection system management

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Fire control panels FC360

DS7400Xi Addressable Control/ Communicator

CATALOG NUMBER. Features. Description

Fire control panels FC726 FC726-XA

Saxon Range 1-8 Zone Convertional Control Panels

SALES SUPPORT DOCUMENT

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

SmartAlarm Annunciator

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S :111

Conventional Fire Detection

Transcription:

ID2000 2-8 loop Intelligent ire Alarm Panel Section: Intelligent ire Alarm Panels GENERAL The NOTI IER ID2000 intelligent fire alarm panel offers a technically sophisticated range of facilities and functions whilst remaining easy to install, program and operate. Modern styling and a variety of aesthetic options are sure to win over facility owners and architects. It has been 3 rd party certified to the current EN54 standards part 2 and 4. A full range of intelligent sensors, advanced detection products, input and output devices, repeaters, mimic drivers, printers and other peripherals complement the ID2000 to bring you the most complete and versatile fire alarm system in the market place. The ID2000 panels can be networked together in a Master / Slave network, extending the total capacity of the system to fit the medium to large applications. The ID2000 is designed in a modular fashion to allow for a wide range of applications, facilitating installation and servicing whilst making the ID2000 very easy to tailor to the requirements of the application. EATURES Intelligent eatures ü Certified to EN54 parts 2 and 4 ü Up to 198 devices per loop (99 sensor and 99 modules) ü Expandable from 2 to 8 loop capacity ü Adjustable sensor sensitivity ü Drift compensation ü Network options Master / Slave ü 10 separate levels of sensitivity for alarm and pre-alarm per point ü Configurable day / night sensitivity adjustment ü Addressable device LED blink control ü Automatic or Manual Loop Learn options ü Automatic device high test at configured time of day ü Walk Test function by zone for efficient commissioning ü On screen test tally (tested / untested count) for devices in zone walk test ü Configurable walk test time limit ü Autoprogram option ü 600 event history file ü Duplicate address fault monitoring ü 2 optional user configurable communication ports ü Dual pulse rate capability for outputs ü Pulsing loop powered sounders capability with steady override ü Non-alarm non-latching addressable device support for lower priority functions ü Variety of Mounting options 990-005, Issue 3 17 April 2003 ü Automatic time control functions by day of week for Control-by-Event (CBE) ü Time of day and day of week exclusions for CBE ü Remote reset output capability for peripheral equipment ü Configurable rapid response from manual call points (less than 3 seconds) ü 80 Zone capacity per panel ü Zone sub-division to cells for CBE ü Coincidence detection configurable by zone or cell for CBE ü ire and fault verification delays configurable by address ü Pre-defined device type characteristics ü Output device test activation by address ü Selective event log display or print by date and time ü Automatic daylight saving time change (configurable) ü ull configuration edit capability from panel or PC ü Multiple options for RS232 port protocol PC Support Tool ü DOS compatible for low specification laptop computers. ü Spreadsheet fashion display for ease of use. This document is not intended to be used for installation purposes. Every care has been taken in the preparation of this document but no liability can be accepted for the use of the information therein. Design features may be changed or amended without prior notice. or more information, contact NOTI IER. Charles Avenue, Burgess Hill, West Sussex, RH15 9U. United Kingdom Phone: +44 (1444) 230300 ax: +44 (1444) 230888 ISO9001 Design, Manufacture and Supply to Quality Management Systems Certified to ISO9001:1994 Quality Systems Certificate No. 154 Assessed to ISO9001 Page 1 of 7 990-053

ü Integrated context sensitive help file. ü Cut and paste editing functions. ü ile management options such as copy and rename. ü Integrated terminal emulation option for real time editing and monitoring, with print to file or printer option. ü Split screen terminal emulation diagnostics. ü Support for serial or parallel printers. ü Site specific installation information embedded into configuration file. ü Authentication requirement for copy protection. User Interface MUTE BUZZER STATUS: NORMAL FRI 19-FEB-99 14:48:40 NOTIFIER ID2000 ALARM SYSTEM DISABLEMENT TEST EARTH ACCEPT POWER SUPPLY SYSTEM POWER DISABLE/TEST EVACUATE SILENCE RESOUND ü 16 to 80 expandable zone indications. ü Optional integral thermal printer. ü Clear and concise fascia layout. ü Software adjustment of timekeeper clock speed. ü Programmable passcode or optional user interface door for access restriction. ü Intuitive operation. ü Configurable Zone and Individual Point location text Modern Housing 7 8 9 4 5 6 1 2 3 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 PRE-ALARM DISABLED SOUNDER DELAY ACTIVE ü Choice of 5 cabinet sizes with expansion capability ü Stylish moulded covers with high security option ü Back Boxes supplied separately ü Primary electronics supplied in chassis format for ease of installation RESET ID2000 CONTROL PANEL Complies With EN54-2/4 1997 Period of Manufacture 1999 ü Optional lockable glazed door for access restriction Optional secondary RS232 port (isolated) ü Graphics System Interface ü Paging System Interface ü 80-column Printer Interface Optional RS485 port (isolated) Analogue Loop Devices Support ü Type A1, A1R and B2 Heat Sensors ü Low-Profile Optical Sensors ü Low-Profile Ionisation Sensors ü Loop Powered Beam Detectors ü Manual Call Points ü Analogue Input Modules ü Analogue Output Modules ü Loop Powered Sounders ü Very Intelligent Early Warning Sensors (VIEW ) ü Self Optimising Optical, Thermal Multi-Sensors (OptiPlex) ü Hostile-ARea Smoke Head Sensors (HARSH ) ü Intrinsically safe Intelligent Optical smoke sensors (HAZARD ) VIEW Sensor ü Revolutionary Point Laser detection ü Advanced AWACS algorithms differentiate between smoke and non-smoke signals ü 99 VIEW sensors per loop capability ü 9 levels of alarm sensitivity from 0.1% to 3.24% per metre obscuration, per sensor ü 9 levels of pre-alarm sensitivity from 0.07% to 1.63% per metre obscuration, per sensor ü Multi-device algorithm, uses nearby sensors in alarm determination ü Maintenance alert ü Addressable operation pinpoints the fire location ü No moving parts to fail or filters to change OptiPlex Sensor ü Self optimising Optical, Thermal sensing technology combined in one sensor. ü 5 smoke sensitivity levels, two self-optimising with heat only output. HARSH Sensor ü Operates as standard optical sensor in dirty environments, with no loss of smoke detection performance ü Dual filters for immunity to nuisance alarms ü Resistant to problems associated with water droplets, visible dust and fibres ü Intake fan motor, power availability and filter state fully monitored HAZARD Sensor ü BASEE A approved to EEx ia IICT5. ü Zone 0 hazardous enviroment installations. System Modules The ID2000 is a flexible modular control panel, built from various option modules. Choose the combinations best suited to the particular application. Each module is supplied with required mounting screws, connection cables, washers etc. and installation instructions. Page 2 of 7 990-053

Basic Equipment kits Note: Yuasa battery sizes are referenced unless otherwise stated. 020-628-xxx ID2000 Basic Equipment Kit Includes main chassis assembly, with hinged display, Base PCB containing two loop interfaces, icroprocessor PCB containing relevant software and spare fuses. 020-628 Basic Equipment kit - Language Group 0 020-628-001 B a s i c Equipment Kit - Language Group 1 020-628-002 B a s i c Equipment Kit - Language Group 2 020-628-003 Basic Equipment Kit - Language Group 3 Extension chassis 020-469-009 Extension Chassis Kit. Zone 17-80 Includes extension chassis with LED display board for zones 17 to80 to indicate fire and fault / disablement / test. Will also accept integral printer. 020-470-009 Extension chassis with PRN2000 Printer Module Kit Includes extension chassis with integral printer fitted. The RS232 card is not required. Uses 1 panel COMMS port. 020-471 PRN2000 Printer Module Kit Includes thermal printer with power supply unit and roll of thermal paper. May be fitted to extension chassis kit 020-469-009 or used as a spare. The RS232 card is not required. Uses 1 panel COMMS port. Power supplies & accessories 020-484 PSU 2.5A Assembly Kit Includes complete power supply unit assembly, interconnection cables and spare fuses. Mounts behind the basic equipment chassis and charges up to 38Ah batteries. 020-579 Universal Power Supply Kit. 4.5A or 7A user selectable. Includes complete power supply unit assembly, interconnection cables and spare fuses. Mounts inside any deep back box kit or the remote battery / PSU enclosure kit and charges up to 130Ah battery capacity. PSU DTP / Booster required in main chassis. 020-543 PSU DTP/ Booster Kit Includes complete PSU interface unit assembly, interconnection cables and spare fuses. Mounts behind the basic equipment chassis. Essential for use with 7A PSU. 020-548 PSU 7A Status Indication Kit This optional unit includes complete assembly and interconnection cables. Mounts on the side of the externally mounted Power Supply Unit Kit and gives status indication of the PSU. 020-541-009 78Ah Remote Battery / PSU Enclosure Kit Floor mounted only back box with extra depth for additional battery space. Powder coated in RAL 7021 extra fine texture. Includes power in connectors. Will hold batteries up to 78Ah. Compatible with PSU7A (020-579). PSU not included. Dimensions 680mm(w) x 510mm(h) x 240.5mm(d) Expansion boards 020-588 Dual Loop Module Kit (LIB) Includes PCB for additional 2 loops, and plug in cable connector. Max. three modules per panel. Maximum of 512 input devices per panel using standard LIBs. 020-478 Isolated RS232 Module Kit Includes PCB for isolated RS232 port for OEM interface, 80 column printer etc. Uses 1 panel COMMS port. 020-479 Isolated RS485 Module Kit Includes PCB for isolated RS485 port for peripherals such as repeaters. Uses 1 panel COMMS port. Page 3 of 7 990-053

Repeaters & Mimic panels 002-450 IDR-2A Active Repeater Includes enclosure with electronics carried on the enclosure door. Requires external 18-32V dc. power supply and panel to be fitted with RS485 card 020-479. Finished in RAL 7021 extra fine texture. Optional Bezel kit, 020-600-009. Dimensions 253.5mm(w) x 165mm(h) x 50mm(d) 002-451 IDR-2A Passive Repeater Includes enclosure with electronics carried on the enclosure door. Requires external 18-32V dc. power supply and panel to be fitted with RS485 card 020-479. Finished in RAL 7021 extra fine texture. Optional Bezel kit, 020-600-009. Dimensions 253.5mm(w) x 165mm(h) x 50mm(d) 020-573 IDR-MD Mimic Control PCA Kit. This comprises a Mimic Driver board and two Mimic termination boards, each mounted on a discrete metal chassis. Up to eight Mimic Driver boards can be driven by one Control board. 020-574 Mimic Driver & Termination Board PCA Kit This comprises a Control board and a Termination board co-located on one metal chassis. The Control board contains the processor and memory, and the Termination board allows connection of power, RS485 and other external signals. The Control board communicates with up to eight Mimic Driver boards. Product literature and tools 020-605 DOS Based PC Support Tool Kit Includes Off-line Configuration software and electronic manuals on a floppy, interconnection cable assembly and installation instructions. Back box & enclosure options 020-472-009 Standard Back Box Kit Basic back box powder coated in RAL 7021 extra fine texture. Includes power in connectors. Will hold batteries up to 12Ah. Suitable only for 16 zone version. Compatible with internal PSU2.5A or external PSU7A. Dimensions 500mm(w) x 400mm(h) x 122mm(d) 020-473-009 Extended Back Box Kit Single extended height back box powder coated in RAL 7021 extra fine texture. Includes power in connectors. Will hold batteries up to 17Ah. Suitable for use with single extension. Compatible with internal PSU2.5A or external PSU7A. Dimensions 500mm(w) x 620mm(h) x 122mm(d) 020-474-009 Extended Deep Back Box Kit Single extended height back box with extra depth for additional battery space, powder coated in RAL 7021 extra fine texture. Includes power in connectors. Will hold batteries up to 38Ah. Suitable for use with single extension. Compatible with internal and external PSU s. Dimensions 500mm(w) x 620mm(h) x 220mm(d) 020-475-009 Double Extended Back Box Kit Double extended height back box powder coated in RAL 7021 extra fine texture. Includes power in connectors. Will hold batteries up to 17Ah. Suitable for use with dual extension. Compatible with internal PSU2.5A or external PSU7A. Dimensions 500mm(w) x 840mm(h) x 122mm(d) 020-476-009 Double Extended Deep Back Box Kit Double extended height back box with extra depth for additional battery space, powder coated in RAL 7021 extra fine texture. Includes power in connectors. Will hold batteries up to 38Ah with chassis fitted. Suitable for use with dual extension. Compatible with internal and external PSU s. Dimensions 500mm(w) x 840mm(h) x 220mm(d) 020-508-009 Standard Extension Back Box Kit Basic back box powder coated in RAL 7021 extra fine texture. Will hold batteries up to 17Ah. Dimensions 500mm(w) x 220mm(h) x 122mm(d) 020-509-009 Deep Extension Back Box Kit Deep back box with extra depth for additional battery space, powder coated in RAL 7021 extra fine texture. Will hold batteries up to 38Ah. Dimensions 500mm(w) x 220mm(h) x 220mm(d) 002-439 Multi-Mount Enclosure Will accept any 2 standard modules / isolators, a single CMX-10R, a Serial Nion or a MRM-1 mains relay. Finished in RAL 7021 extra fine texture. Page 4 of 7 990-053

Covers & bezels options 020-038-009 Bezel Standard Semi-flush mount bezel for standard height back box. Finished in RAL 7021 extra fine texture. 020-039-009 Bezel Extended Semi-flush mount bezel for extended height back box. Finished in RAL 7021 extra fine texture. 020-040-009 Bezel Double Extended Semi-flush mount bezel for double extended height back box. Finished in RAL 7021 extra fine texture. 020-480-009 Main Cover Kit Includes moulding, hinges for user interface door, push clip fasteners, Notifier label and hex fixing tool. Finished in RAL 7021 extra fine texture. Moulding adds 31mm to overall depth of back box. RAL 7021 extra fine texture. Moulding adds 31mm to overall depth of back box. 020-514-009 Extension Cover High Security Kit Includes moulding, hinges for user interface door, high security fasteners and printer slot covering label. Finished in RAL 7021 extra fine texture. Moulding adds 31mm to overall depth of back box. 020-515 High Security Tool For use with the high security fasteners on the high security moulded covers 020-513-009 and 020-514-009. 020-485-009 Extension Cover Blanking Plate Kit Blanking plate kit for extension cover moulding where no extension chassis is required. May be used for customisation such as mounting of plant switches. Finished in extra fine texture. 020-513-009 Main Cover High Security Kit Includes moulding, hinges for user interface door, high security fasteners and Notifier label. Finished in RAL 7021 extra fine texture. Moulding adds 31mm to overall depth of back box. 020-481-009 Extension Cover Kit Includes moulding, hinges for user interface door, push clip fasteners and printer slot covering label. Finished in 020-482 Main User Interface Door Kit Lockable user interface door kit for additional primary display level 2 access restriction and tamper resistance. 020-483 Extension User Interface Door Kit Lockable user interface door kit for tamper resistance to extension interface. Page 5 of 7 990-053

Controls and Indicators Led Status Indicators ü IRE ü AULT ü DISABLEMENT ü TEST ü EATH AULT ü POWER SUPPLY AULT ü SYSTEM AULT ü POWER ü PRE-ALARM ü SOUNDER DISABLED ü SOUNDER AULT ü DELAY ACTIVE ü DAY MODE ü REMOTEOUTPUT DISABLED ü REMOTEOUTPUT AULT ü REMOTEOUTPUT OPERATED Membrane Switch Controls ü MUTE BUZZER ü ACCEPT ü EVACUATE ü SILENCE ü RESOUND ü RESET Membrane Programming and Selection Keys ü 10-Key Numeric Key-pad ü,,, Navigation Arrows Panel Specifications Primary Input Power ü 230V, 50Hz ( used at 5A Recommended, 5A mains spur) Sounder Outputs ü 2 Sounder outputs @ 1A each Sounder / Volt-free Outputs ü 2 Sounder / Volt-free output contacts rated 30V 1A. Relay Outputs ü ire Relay Output @ 30V 1A. ü ault Relay Output @ 30V 1A. Auxiliary Power Output ü 2 Auxiliary Outputs rated @ 26-28V 1A Each Total Auxiliary Output ü Total Sounder and auxiliary power dependent on power supply option selected (please refer to Notifier s see PSU Specifications) Battery Space ü 12Ah with standard back box ü 17Ah with extended / doubleextended back box ü 38Ah with extended deep / doubleextended deep back box ü 78Ah with Remote Battery / PSU Enclosure ü and Pushbuttons ü Pushbutton LCD Display : ü Alphanumeric 80 Character (2 x 40) Back-lit Display Keyswitch ü Level 2 Access Code Keyswitch Panel capacity ü 2 to 8 Loops per panel ü 80 Zone LED indication options on Extended Panel cabinets ü 99 Intelligent Sensors per loop ü 99 Addressable Monitor/Control Modules per loop Page 6 of 7 990-053

ID2000 SERIES CONTROL SYSTEM Master / Slave Network ID2000 Series Double Extended Panel ID2000 Series Panel ID2000 Series Extended Panel IDR-2P Repeater Panel STATUS: NORMAL IDR-2A Repeater Panel FRI 19-FEB-99 14:48:40 NOTIFIER ID2000 ALARM SYSTEM STATUS: NORMAL FRI 19-FEB-99 14:48:40 NOTIFIER ID2000 ALARM SYSTEM MUTE BUZZER ACCEPT EVACUATE SILENCE RESOUND 1 RESET 2 4 MUTE BUZZER ACCEPT EVACUATE SILENCE RESOUND 1 RESET 4 7 2 3 5 6 8 9 DISABLE/TEST 1 2 3 4 5 6 DISABLEMENT PRE-ALARM TEST DISABLED SOUNDER POWER SUPPLY DELAY ACTIVE 7 8 9 10 11 12 13 14 15 ACCEPT EVACUATE SILENCE RESOUND 1 RESET ID2000 CONTROL PANEL Complies With EN54-2/4 1997 Period of Manufacture 1999 SYSTEM POWER 8 3 6 9 MUTE BUZZER ACCEPT EVACUATE SILENCE RESOUND RESET 0 16 MUTE BUZZER PRE-ALARM TEST DELAY ACTIVE DISABLEMENT PRE-ALARM DISABLEMENT COMMUNICATIONS LOSS FRI 19-FEB-99 14:48:40 NOTIFIER ID2000 ALARM SYSTEM EARTH 5 7 STATUS: NORMAL 0 3 2 4 5 6 7 8 9 SYSTEM POWER DISABLE/TEST 1 2 3 5 4 6 TEST DISABLED EARTH SOUNDER POWER SUPPLY DELAY ACTIVE 7 8 9 10 11 12 13 14 15 16 ID2000 CONTROL PANEL Complies With EN54-2/4 1997 Period of Manufacture 1999 SYSTEM POWER IDR-2P PRE-ALARM TEST DELAY ACTIVE DISABLEMENT COMMUNICATIONS LOSS POWER SYSTEM IDR-2A 0 DISABLE/TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 PRE-ALARM DISABLEMENT TEST DISABLED EARTH SOUNDER POWER SUPPLY DELAY ACTIVE ID2000 CONTROL PANEL Complies With EN54-2/4 1997 Period of Manufacture 1999 SYSTEM POWER Call Point VIEW Sensor Fire NOT IN USE HORS SERVICE BUITEN GEBRUIK FUORI SERVIZIO AUSSER BETRIEB FUERA DE SERVICIO 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 VIEW Sensor 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 Heat Sensor Control Relay Output Door Holder (Externally Powered) CAUTION DE-ENERGIZE UNIT PRIOR TO SERVICING Optical Sensor Duct Sensor MULTI Sensor HARSH Sensor Sounder Control Unit Short Circuit Isolation Module MODULE ACTIVE Fire Call Point NOT IN USE HORS SERVICE BUITEN GEBRUIK FUORI SERVIZIO AUSSER BETRIEB FUERA DE SERVICIO Loop Powered Sounder Ionisation Sensor Loop Powered Sounder Base and Sensor Conventional Detector Interface CAUTION DE-ENERGIZE UNIT PRIOR TO SERVICING Beam Detector (Externally Powered) Loop Powered Sounder Base and Sensor Conventional Detectors COMPATIBLE SLC DEVICES Model CPX-551E CPX-751E SDX-551E SDX-751E HPX-751E FDX-551E FDX-551HTE FDX-551RE LPX-751 SDX-751TEM IDX-751 LPB-500 LBP-620 M500KAC/GB M500KACW MMX-1E MMX-101E MMX-102E Description Standard Ionisation Sensor Low Profile Ionisation Sensor Standard Optical Sensor Low Profile Optical Sensor HARSH Optical Sensor Type A1 Thermal Sensor Type BS Thermal Sensor Type A1R Thermal Sensor VIEW high sensitivity intelligent sensor OPTIPLEX Multi-criteria smoke & heat sensor HAZARD intrinsically safe optical sensor Loop Powered Beam Detector (TX/RX pair) Loop Powered Beam Detector Manual Call Point Weatherproof Manual Call Point Monitor Module Mini Monitor Module Micro Monitor Module MMX-10 ZMX-1E CMX-2E PS2-CMX CMX-10R ISO-X MRM-1(/DIN) B501 B524IE B524IEFT B254RE B524FTXE ANS4 ANSE4 ABS4 ABSE4 IBS3 AWS3/R AWS3/W White 10 Way Monitor Module Conventional Zone Monitor Module Control Module (Monitored or Relay) Control Module With PSU and 2 Bell Circuits 10 Way Relay Module Standard Isolator Module Mains Relay Module Standard Sensor Base Sensor Base With Standard Isolator Sensor Base With FET Isolator Sensor Base With Relay Output HARSH Sensor Base Addressable Loop Powered Sounder Addressable Externally Powered Sounder Addressable Loop Powered Sounder Base Addressable Externally Powered Sounder base Addressable Loop Powered Base Sounder with Built-in Sensor Base Addressable Loop Powered Wall Sounder Red Addressable Loop Powered Wall Sounder Some devices may be under development. Contact NOTIFIER for device availability. Page 7 of 7 990-053