INSTALLATION INSTRUCTIONS

Similar documents
INSTALLATION INSTRUCTIONS

Thermostatic shower valve with 2 way diverter, brass faceplate and handles - V51

Thermostatic shower valve with 3 way control, brass faceplate and handles - V52

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

THERMOSTATIC SHOWER CONCEALED VALVE - TWIN WITH DIVERTER & TRIPLE WITH DIVERTER

Beautifully Traditional

Beautifully Traditional

CONCEALED THERMOSTATIC SHOWER MIXER VALVE installation & aftercare instruction

CONCEALED THERMOSTATIC TOUCH SHOWER MIXER VALVE Installation & Aftercare Instructions (1) (2) PLEASE READ BEFORE INSTALLATION

Varsity Concealed Shower System

Kinetic. Logic. Astin. THERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions. Please retain for future reference

Technical Specifications: Your product has a high quality finish and should be treated with care to preserve the visible surfaces.

Beautifully Traditional

Traditional Rigid Riser With Eight Inch Rose

X A M G3/4 G3/

Beautifully Traditional

Installation Instructions & Maintenance Guide 6 Refit Nuts (19) and tighten.

Dual Control Concealed & Exposed Thermostatic Shower Valve

METRO BATH FILLER MOUNTED CHR

BLADE BATH SHOWER MIXER DECK MOUNTED CHR WITH KIT INSTALLATION INSTRUCTIONS P BS-E A/2

MBSY110P+ BASIN MONOBLOC WITH CLICK CLACK WASTE

Installation Instructions

Installation Instructions. Starck

COX714DC. Dual Control Sensor Kitchen Mixer chrome

Beautifully Traditional

Installation Instructions. Hansgrohe S 15721XXX

Wave. BATH SHOWER MIXER MONOBLOC With Kit Deck Mounted

Concealed Twin & Triple Thermostatic Shower Valve with Diverter. Installation & Operating Guide

Thermostatic Bar Valves

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

UB110DNC/L/U/B BASIN MONOBLOC WITH NO POP-UP WASTE BASIN MONOBLOC TALL WITH NO POP-UP WASTE UB112DNC/L/U/B INSTALLATION INSTRUCTIONS

Self-help Temperature Adjustment

Varsity Exposed Shower Systems

Twin & Triple Exposed Thermostatic Shower Valve Installation & Operating Guide

METRO BASIN MONO MIXER CHR

Enzo Concealed Shower Mixing Valve

RM530WC+ DIAL EXPOSED THERMO SHOWER VALVE INSTALLATION INSTRUCTIONS

Inta City Concealed Shower Mixing Valve CT80010CP

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve. Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C,

Mio Concealed Shower Mixing Valve MI40010CP

Inta City Shower Mixing Valve CT20010CP

Telo Shower Mixing Valve TL10016CP

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

GENERAL FITTING GUIDE THERMOSTATIC BAR SHOWER MIXER with RIGID RISER KIT

MIDAS. Installation instructions 110/220

Deluge Concealed Shower Mixing Valve DL40010CP

Puro Mini Dual Control Shower Mixer PU90010CP

Francis Pegler Memento Single Sequential Exposed Thermostatic Shower

Deluge Shower Mixing Valve 10045CP

Dream DCV. Thermostatic Dual control mixer valve range. Installation guide

Plus Bath Shower Mixing Valve CP and PL30020CP

EXPOSED BATH SHOWER MIXER INSTRUCTION MANUAL W INST 300. Please note: Tap heads shown is for illustration purposes only.

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter

Kiko Concealed Shower Mixing Valve KK80010CP

Aquamixa. Thermo. Thermostatic shower valve with manual bath fill

OWNER S GUIDE SEQUENTIAL THERMOSTATIC SHOWER VALVE. 150mm Inlet Pipe Centres. Shower Control. Handles and. may differ depending.

Thermostatic Bar Valve

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

Installation Instructions and User Guide Thermostatic Recessed Dual Control Shower Valve

Enzo Safe Touch Thermostatic Shower EZ20011CP & EZ20012CP

Thermostatic bar mixer valve with adjustable head Installation guide

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve with Integral Diverter

Quartz. Thermo. Concealed shower valve with adjustable head. Quartz Thermo installation guide page 1

Enzo and Enzo Deluxe Safe Touch Thermostatic Shower EN10031CP & EN10035CP

Kiko Bath Shower Mixing Valve KK90015CP

ARIN THERMOSTATIC SHOWER SYSTEM

Thermostatic Bar Valve THE QUALIFICATIONS INSTALLATION INSTRUCTIONS

Avensys Avensys FIN EST SLO RUS UAE

s y ens Av Avensys FIN EST RUS SLO RUS UAE

MK 8706 / MB 8706 CONCEALED THERMOSTATIC SHOWER VALVE INSTALLATION GUIDE

TREVI BLEND SINGLE LEVER SHOWER VALVES. INSTALLER After installation pass to user for future reference

Bar valve with fixed and adjustable shower heads. Installation guide. Midas Plus installation instructions Page 1

Installation Instructions and User Guide Thermostatic Recessed Dual Control Shower Valve

Blueberry Kitchen Sink Tap

Cinnamon Kitchen Sink Tap

AIRE. Thermostatic bath shower mixer. Installation and Operating Instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Please tape down. NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW

TYNE. Installation and Operating Instructions. Thermostatic bath shower mixer. Installers please note these instructions are to be left with the user

Thermostatic Bar Valve THE QUALIFICATIONS INSTALLATION INSTRUCTIONS

HW3 Handwash Installation and Operating Instructions

Thermostatic Concealed Shower Valve

X62 Tap Range. Please keep these instructions for future reference

Avensys Avensys FIN EST SLO RUS UAE

METIS. Installation instructions. Riser rail kit INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER.

Installation Instructions and User Guide Thermostatic Recessed Three Control Shower Valve with Stopcock & Two outlet Diverter

Express Thermo Shower Mixer Set With Handset THE QUALIFICATIONS INSTALLATION INSTRUCTIONS

Installation Instructions and User Guide Thermostatic Recessed Three Control Shower Valve with Integral Twin Stopcocks

Please tape down. NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW

AQ150:Midas 10/9/15 14:50 Page 1 AQ150. Thermostatic bar mixer valve with adjustable head. Installation guide

CEILING FED RISER RAIL KIT. Installation Guide. tritonshowers.co.uk/digital

Thermostatic exposed shower valve and bath/shower mixer systems Installation guide

Monza Easyfit Kitchen Sink Mixer

Shower Panels with a Thermostatic Sequential Control

Quartz. Digital. Concealed with adjustable height and fixed head. Quartz Digital concelaed adjustable/fixed installation instuctions page 1

900 Quadrant Steam Shower Cabin with 6 Body Jets

Transcription:

INSTALLATI INSTRUCTIS Trent Thermostatic Two Outlet Concealed Shower Valve, Fixed Shower Arm, Handset & Holder with Hose - TF3S Options: urlington has 2 different style handles for your selection, when using these additional handles the indices will need to be utilised from the original handles. Anglesey irkenhead NOT INCLUDED IN THE OX Options: urlington has a shower head of 3 different sizes for your selection. NOT INCLUDED IN THE OX Important We recommend that this product is installed by a qualified professional contractor. Such as a plumber who is certified by NVQ (National Vocational Qualification) or SNVQ (Scottish National Vocational Qualification) Level 3 Please check this product immediately to ensure that it has not been damaged and is complete. efore installation, please make sure this product is the correct model and you have all the parts required for installation and using. This valve is a mixing device and therefore requires the water supplies to be reasonably balanced, otherwise we recommend a pressure reducing valve to be fitted. Please flush the water system to ensure that no metal swarf, solder, and other impurities can enter the valves. Turn off water supply before commencing work, this should be done at the isolating valves of inlet feeds if fitted or main stopcock. Please read these instructions carefully and keep it for future reference. Conditions for the use of thermostatic mixing valve The thermostatic valve has been designed to be compliant with the relevant UK standards applicable to this type of product governed by TMV2 standards and WRC. The valve is tested against S EN 1111. The valve will operate under low pressure but it is recommended that the cold water supply is at least 2 meters from the outlet of the shower valve. This thermostatic valve is suitable for use with all water systems up to a maximum operating pressure of 5.0 bar, (beyond which we recommend pressure reducing valves to be fitted.) The valve is provided with two outlets, which are controlled by two flow control cartridges. Commonly used for a main shower head or a flexible shower kit. An independent, flexible hot and cold water supply pipe is recommended for use to easy maintenance. If installing a shower pump always install the pump before the shower valve. The list below shows the recommended limits for correct operation; Low Pressure Maximum Static Pressure ar 10 Flow Pressure, Hot & Cold - ar 0.2 to 5 Hot Supply Temperature - C 55 to 65 Cold Supply Temperature - C Equal to or less than 25 The ritish urns Association recommends 37 to 37.5 C as a comfortable bathing temperature for children. In premises covered by the Care Standards Act 2000, the maximum mixed water outlet temperature of 43 C. 1-6

395 G1/2" Ø18 G1/2'' 155.4 87.4 185.4 Dimension Ø60 10 236.37 274.6 Ø60 95 162.3 75~90 G3/4 226 280 Ø62 Ø38 80 385.9 80 G3/4 13.3 6.5 G3/4 120 48.3 G1/2 Parts Identification MAIN OUTLET (SHOWER-FIXED HEAD) FLOW CTROL COLD INLET RAWL PLUG G1/2 42.6 SLEEVE WATER FLOW CTROL HANDLE ACK PLATE FIXING LUGS CAP SPRING FILTER RING CHECK VALVE HOT INLET (ATH/FLEXILE HEAD) FIXING SCREW FLAT JOINTER NUT SLEEVE SCREW METAL LOCK THERMOSTATIC TEMPERATURE CTROL HANDLE DECORATIVE HEAD 2-6

Installation HOT WATER FEED (flexible/pipe) COLD WATER FEED (flexible/pipe) 2x 2x PROTECTIVE SLEEVE 1 ref. 110mm ADHESIVE TAPE 3 2 WALL 4 5 INLET PIPE 3-6

WALL INLET PIPE SHOWER HANDSET ELOW HOSE CE END TAIL 6 7 SHOWER HOOK WALL PLUG SCREW ELOW HOSE NUT END 8 9 The valve should be installed in accordance with the water bye-laws. For further details refer to the latest copy of Water ye-laws guide or your local water authority. Note: Please check for any hidden pipes and cables before drilling holes in the wall. The fitting of isolation valves is required as close as is practicable to both hot and cold water supply inlets. 1. Put the valve (make sure the two protective sleeves are protecting the chrome section) onto the wall and mark the position of the fixing lugs (X2). 2. Make sure the valve is set back from the front face of the wall by the appropriate depth to allow for plasterboard, tiling and filling etc. (min. 75 to max. 90mm) 3. Mount the valve to the wall using suitable fixings (see Fig 1). 4. Inlets and outlets are all tapped 3/4. Make all the pipe work connections using a thread sealer. Don t use the tapered threaded adaptors. 5.Two outlets are recommended for use, one is for a main shower head, the other is for a flexible shower kit. The pipe connection is recommended as the diagram above (see Fig 1). That will be convenient for taking off the valve for easy maintenance. 6. Turn on supplies and test all connections for water tightness. (if necessary, the filter and check valve need to be cleaned) 7. Then install the plasterboard and tile the wall. 8. Remove the adhesive tape film on the backside of back plate. Paste the back plate on the wall. (see Fig 2) 9. Apply a narrow bead of silicone sealant around the back edge of the back plate and carefully press into position. 10. Mount the handles into position (see Fig 3). 11. Install the shower arm on the wall, put the shower head onto the shower arm (see Fig 4 & 5). 12. Connect the elbow with the other outlet (see Fig 6). 13. Seperatelly connect the hose with the shower handset & the elbow (see Fig 7 & 8). 14. Make sure the shower hook at a suitable position, fix it onto the wall (see Fig 9). 4-6

90 Operation 1. Turn the water flow control handle to increase/decrease the water flow and turn on/off. 2. Turn the temperature control handle to increase/decrease the water temperature. WATER FLOW CTROL HOT 270 COLD TEMPERATURE CTROL WATER FLOW CTROL Temperature Setting 90 The temperature control handles on this product are factory set and should require no adjustment. However, if for any reason the handles and/or the cartridge is removed it is important the following procedure is followed. SPINDLE METAL LOCK 2 1 1 ) Remove the temperature control handle, metal block as the page 2 diagram. 2 ) Rotate the exposed thermostatic spindle (clockwise for cold, and anti-clockwise for hot), until the maximum desired showering temperature is set. The suggested maximum pre-set temperature is 42 C (see Fig 1). 3 ) Without any move at the spindle, replace the metal block so that limit stop up to the right hand side of the limit stop on the cartridge (see Fig 2). 4 ) Then refit the temperature control handle. Maintenance * After a long time usage of thermostatic valve, there will be some waste debris from the water pipe on and around the check valve or thermostatic cartridge, which will affect the flow and sensitivity of automatical temperature adjustment. Please take out the thermostatic cartridge, and clean the cartridge strainer. * To avoid damage, please remove all chrome parts before any maintenance takes place. Maintenance (Filter & Check valve) CHECK VALVE RING FILTER CHECK VALVE RING A) Cutoff the Hot & Cold supply at the isolating valve. ) Disconnect the hot & cold water supply from the valve. C) Use a suitable screwdriver to remove the fixing screws. D) Fetch out the valve, and take out the filter, check valve. E) Clean the filter and check valve with clean running water, FILTER dry and lightly grease the seals. (only use silicone grease) F) Put back all of the parts in sequence. 5-6

Maintenance (Thermostatic Cartridge) THERMOSTATIC RING LOCATING LUG The concealed thermostatic cartridges should give trouble free service, but in the event of failure, servicing is straight forward. A) Remove the cartridge retaining ring. ) Pull out the thermostatic cartridge. C) Wash the thermostatic cartridge with clean running water, dry and lightly grease the seals (only use silicone grease). D) Put back the thermostatic cartridge (The locating lug should be sit inside the socket of housing), then tighten the retaining ring. Commissioning & Annual Test The installation of thermostatic mixing valves must comply with the requirement of the Water Supply (Water Fittings) Regulations 1999. TMV2 approve valve must be tested once a year, to check if it is out of the original maximum temperature set. 1. Prepare a calibrated thermometer. 2. Adjust to maximum water temperature. 3. Allow water running 5 seconds for stability, measure the mixed water temperature at the outlet. The mixed water temperature at the outlet should never exceed 42 C for showers. The mixed water temperature at the outlet should never exceed 46 C for bath filler. Note: 46 C is the maximum mixed water temperature from the bath tap. The maximum temperature takes account of the allowable temperature tolerances inherent in thermostatic mixing valves and temperature losses in metal baths. It is not a safe bathing temperature for adults or children. The ritish urns Association recommends 37 to 37.5 C as a comfortable bathing temperature for children. In premises covered by the Care Standards Act 2000, the maximum mixed water outlet temperature is 43 C. IF NOT, then the adjustment of the temperature is necessary following the Temperature Setting 4. Close the isolating valve at the Cold water supply. While the flowing is residual, and the water temperature has no any change obviously from the initial maximum temperatue set. 5. Reopen the Cold supply, retest the water temperature. if also having no change obviously. Then the valve is working correctly, no further service work is required. Trouble Shooting 1. Output water temperature does not correspond with temperature set Cause: Thermostat has not been adjusted base on the existing home water system Remedy: Adjust the thermostat, refer to Temperature Setting procedure. Cause: Hot Water temperature too low. Remedy: Adjuster the water heater, increase hot water temperature to 65 C 2. Crossflow, cold water being forced into hot water pipe, or vice versa, when valve is closed Cause: check valves dirty or leaking Remedy: Clean the check valves or exchange if necessary 3. Very low flow or no flow Cause: Supply pressure inadequate Remedy: Check hot and cold feeds. If a pump has been installed, please check to see if the pump is working. (the valve will shut down if either the cold or hot water supply fails) 4. Water will not run hot enough when first installed Cause: Wrong maximum temperature setting Remedy: Adjust the maximum temperature, refer to Temperature Setting procedure. Cleaning We do NOT recommend you use any household cleaners to clean the product. ecause these cleaners change substance or formula too frequently. So product should be always cleaned only with soapy water and rinsing with clean water and drying with soft cloth. 6-6