WH231/WR231. General Features. Operational Information. Discharge 11 gpm at 40 psig (0.69 lps at 28 m) 7.8 gpm at 80 psig (0.

Similar documents
ELECTRICAL DH VERSUS DR SERIES OPTIONS LISTED IN THE ONLINE AND PRINT CATALOG FOR ENVIRONMENT ONE DH071/DR071 STATIONS. WHICH DO YOU SELECT?

D-Series Wetwell/Drywell Grinder Pump Station with Wired Level Sensor. Typical Specifications. Semi-Positive Displacement Type Grinder Pump Stations

Installation and Operation Manual

Engineered Basins Affordable, effective pressure sewer system Rocky, hilly, wet and flat topography Dependable, reliable and cost effective

STANCOR Oil-Minder Simplex & Duplex Pump and Control Systems

IH091: Home Wastewater Disposal System Installation Instructions & Warranty Information

C1210ES Tankless Water Heater

E/One Sentry Advisor

Centro-Matic Automated Lubrication Systems System Controls

Section K CHLORINATION EQUIPMENT

SIMPLEX WEATHERPROOF CONTROL PANELS

DIESEL Engine Fire Pump Controllers Features

C1050ES Tankless Water Heater

FTA550 JOCKEY PUMP CONTROLLERS

ONQUEST. Featuring... Condensing Water Heater. Requires no tank linings or heat exchanger linings. Requires no anodes of any type. 10- year warranty.

Setup & Operation Index

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

We ve Got Panels Under Control.

Drawing Submittal Package

CHAPTER 20 SERVICE EQUIPMENT

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES

940ES Tankless Water Heater

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

SN Series - Safety Shower Heaters Tankless Water Heating Solutions

Custom Pump Controls. The Custom Controls Solution Provider. A New Generation. Complete Management. Page 2

KGP(X) Grinder Pumps HP Grinder Pump, 3 Phase (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve.

940ES Tankless Water Heater

FTA550F JOCKEY PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

AquaSaver DISPOSER CONTROL CENTER Installation Manual. Model AS-101K

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

Oxygen (O2) Single-Point Gas Detection System

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Drawing Submittal Package

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Specifications. STEALTH Simplex, Wall Mount For SGV, OGP & OGV Grinder Pumps Control Panels & Accessories.

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

TABLE 1. Specifications: Dimensions: 6¼ x 9 5/8 x 2 ¾

Technical Data Submittal Document

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

QUICK SHIP Products. Available for Same/Next Day Shipment at NO ADDITIONAL CHARGE!

PRODUCT CATALOG SURFACE PUMPS RESIDENTIAL & LIGHT COMMERCIAL. franklinwater.com

FDF Foam Pump Controllers Features

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

Easy to use, initiate test with the push of a button No additional tools required Provides visual alert to abnormal power conditions

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

254 Nanometer Germicidal UV Disinfection Systems

(EE1500, EE2000, EE2500, EE3000)

Low Water Cutoff (LWCO) IQ Option Card p/n , for Hot Water Boilers

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

5. CONDENSATE PUMPS/UNITS

Annunciation, Remote Monitoring, Control Industrial Control Panels

Series. Access Power Controllers. Installation Guide

Tankless On Demand Electric Water Heater

1. Read all instructions before proceeding with the installation. Improper installation may void warranties.

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

GPF Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FOR

Residential Gas Tankless Water Heater

KEENER GRINDER PUMPS

VetPro Solo Installation

Special Provision No. 682S27 June This Special Provision refers to the following standards, specifications or publications:

CALL FOR TENDER - MUNICIPALITY OF THE DISTRICT OF CLARE LITTLE BROOK, N.S.

Tankless Condensing High Efficiency Water Heaters with Built-In Pump

B. Shop Drawings: List of legends and description of materials and process used for premarking wall plates.

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

AM SELECT DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES VOLTAGE. Item # Quantity C.S.I. Section AM15

WH101F & WR101F Typical Installation Instructions & Warranty Information. Simplex Station

Enclosed Scroll Air Compressor System SES 3-5 HP

Gfci Self Test Duplex 20A 125V WH

Using the DewTrak II Dew Point/ Humidity Transmitter

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Conquest. Condensing Gas Water Heater. 199 to 300 MBH 100 Gallon Tank 15-year Warranty. PVI.com

Phase-Adaptive Power Module

AccuBrine automated brine maker Technical Specifications

Piggyback Mechanical Float Switch. Piggyback Vertical Mechanical Float Switch. Piggyback Diaphragm Switch. Accessories

Tankless Condensing High Efficiency Water Heaters

POWERSEWER ENGINEERED PRODUCTS. franklinengineered.com

ECS Pre-Engineered Nitrogen Generator. ECS Pre-Engineered Wall Mount Nitrogen Generator PGEN-3/(PGEN-3E) PGEN-5/(PGEN-5E)

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Technical Data Submittal Documents

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

SpaceKeeper Console (SKC)

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

Dräger Polytron 8000 Stationary gas detector (EC)

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

DEMA 813 PROBELESS DEMAMaster TM INSTALLATION INSTRUCTIONS

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

CS1000. Single Pole Plugs & Connectors up to 400A, 1000VAC Featuring: Silver-Nickel, Butt-Style Contacts. Locking Pin. Finger Guard (IP2X)

ECS Protector Nitrogen Generator PGEN-40FK/PGEN-50FK/PGEN-60FK PGEN-40M/PGEN-50M/PGEN-60M

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

Transcription:

WH231/WR231 General Features The model WH231 or WR231 grinder pump station is a complete unit that includes: the grinder pump, check valve, polyethylene tank, controls, and alarm panel. The lower portion of the tank has a smaller diameter, tapered down to a dish-shaped bottom. These design features reduce the retained volume and promote scouring, which will minimize odor and corrosiveness. Rated for flows of 850 gpd (3218 lpd) 237 gallons (874 liters) of capacity Standard outdoor heights range from 55 inches to 92 inches The WH231 is the hardwired, or wired, model where a cable connects the motor controls to the level controls through watertight penetrations. The WR231 is the radio frequency identification (RFID), or wireless, model that uses wireless technology to communicate between the level controls and the motor controls. Operational Information Motor 1 hp, 1,725 rpm, high torque, capacitor start, thermally protected, 120/240V, 60 Hz, 1 phase Inlet Connections 4-inch inlet grommet standard for DWV pipe. Other inlet configurations available from the factory. Discharge Connections Pump discharge terminates in 1.25-inch NPT female thread. Can easily be adapted to 1.25-inch PVC pipe or any other material required by local codes. Discharge 15 gpm at 0 psig (0.95 lps at 0 m) 11 gpm at 40 psig (0.69 lps at 28 m) 7.8 gpm at 80 psig (0.49 lps at 56 m) Patent Numbers: 5,752,315 5,562,254 5,439,180 NA0059P01 Rev B Accessories E/One recommends that the Uni-Lateral, E/One s own stainless steel check valve, be installed between the grinder pump station and the street main for added protection against backflow. Alarm panels are available with a variety of options, from basic monitoring to advanced notice of service requirements. The Remote Sentry is ideal for installations where the alarm panel may be hidden from view.

E/One Sentry TM Alarm Panel Protect Plus Package Description The E/One Sentry panels are custom designed for use with Environment One grinder pump stations. They can be configured to meet the needs of your application, from basic alarm indication to advanced warning of pending service requirements. E/One Sentry panels are supplied with audible and visual high level alarms. They are easily installed in accordance with relevant national and local codes. Standard panels are approved by UL, CSA, CE and NSF to ensure high quality and safety. The panel features a corrosion-proof, NEMA 4X-rated, thermoplastic enclosure. A padlock is provided to prevent unauthorized entry (safety front). Standard Features Includes all features of the basic configuration of the E/One Sentry panel, including circuit breakers, 240 or 120 VAC service, terminal blocks and ground lugs, audible alarm with manual silence, manual run feature and run indicator, redundant Start function with high level alarm, safety front, conformal-coated board and overload protection. Includes all of the features of the E/One Sentry Protect package, including a Trouble indication that shuts down the pump temporarily in the event of an unacceptable operating condition (brownout, system overpressure, run dry), as well as: Predictive status display module Pre-alarm indication for major operating parameters Alarm indications for major operating parameters Hour meter, cycle counter and alarm delay LCD display and user-friendly interface Inner cover (dead front) Contact group dry and Remote Sentry Optional Features Generator receptacle with auto transfer GFCI Main service disconnect NA0079P01 Rev. B Please consult factory for special applications.

OLD / NEW WIRE COLOR MAP PIN FUNCTION 2000S EXTREME 1 MANUAL RUN RED BROWN 2 L1 BLACK RED 3 L2 WHITE BLACK 4 GND GREEN GRN/YEL 5 ALARM FEED ORANGE YELLOW 6 ALARM RETURN BLUE BLUE

OLD / NEW WIRE COLOR MAP PIN FUNCTION 2000S EXTREME 1 MANUAL RUN RED BROWN 2 L1 BLACK RED 3 NEUTRAL WHITE BLACK 4 GND GREEN GRN/YEL 5 ALARM FEED ORANGE YELLOW 6 ALARM RETURN BLUE BLUE