Long lasting unit provided by heavy-duty, corrosion-resistant, galvanized steel construction.

Similar documents
Helps reduce cycle time and increase productivity with advanced SPRAY-CURE technology.


CORAYVAC Helps Reduce Energy Bills and Improve Comfort

STR-Series Indirect-Fired Air Turnover Units

BANANZA. B-Series Direct-Fired Heating, Cooling And Pressurization Systems. Equipment Specifications

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE COOLING-ONLY 100% OUTSIDE AIR VERSION Telephone:

ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE HEATPUMP 100% OUTDOOR AIR VERSION Telephone:

Combat. DF-Series Direct-Fired Heating, Cooling and Pressurization Systems. Equipment Specifications

Installation, Operation & Service Manual

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

Cabinet Heaters. Over 91.5% NET Efficient! Quality in Any Language TM. Ideal for industrial and commercial applications

GLOBAL FINISHING SOLUTIONS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

SECTION 7: OPTIONAL HEATER ACCESSORIES. Step Reflector Joint Installation. Step Reflector Joint Detail. FIGURE 19: Reflector Joint Detail

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

NRG Control WARNING. Energy Saving Control for Combat Warm Air and Blackheat Radiant Heating Equipment Installation, Operation and Service Manual

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

System Control. Installation, Operation & Service Manual WARNING. Installer

Equipment Specifications

Heating safely with gas-fired infrared heaters

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

TIO THE LEADER SPRAY BOOTH APPLICATIONS

Suggested Specifications Prestige Excellence 110

Fuel Conversion Kit Instructions

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS

Direct Fired Heater Model AD Specification

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

LARGE CAPACITY HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS

GAS-FIRED HIGH INTENSITY INFRARED HEATERS

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

Direct Gas-Fired Make-Up Air

Power Flame Incorporated

Engineering Submittal Data PPRTH Patio Radiant Tube Heaters.

Indirect Gas-Fired Make-Up Air

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

MODEL ADF/ADFH 300 and 500 INDOOR/OUTDOOR DIRECT-FIRED GAS HEATING/MAKEUP AIR SYSTEM FOR INDUSTRIAL & COMMERCIAL APPLICATIONS

Flame relay units are necessary in most industrial combustion systems. These flame relay models are capable of meeting most application needs.

AFUE 95% Heating Input 50,000 to 200,000 Btuh

WATER-TUBE POOL HEATERS

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

CB/CF. Series CONDENSERS AND CONDENSING UNITS. Features:

ELITE SERIES Downflow - High Efficiency Blower Motor

ADF/ADFH 300 and 500

The H Series. Pure and Simple Solutions. HTLV Space Heating

INSTALLATION, OPERATION & MAINTENANCE MANUAL INDIRECT GAS-FIRED DUCT FURNACE

WATER-TUBE POOL HEATERS

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

A. Product Data: Include rated capacities, furnished specialties and accessories.

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

1.03 DELIVERY, STORAGE, AND HANDLING Heater will be stored to secure against damage and handled per manufacturer s recommendations.

Modular Heating & Ventilating Unit Model IGX-HV

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

SECTION AIR DOORS

2012 Catalog Version AUG 2012 Noritz America Corporation. All rights reserved.

Design Specifications for Panda 900A Car Spray Booth

INFRARED RADIANT TUBE HEATER

EZ TANKLESS EZ 101 & 202 OPERATION & INSTALLATION MANUAL

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Air Make-Up Units. Product Line Overview & Capabilities

MERIT SERIES Downflow

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA

PROBUILDER SERIES TM 36 Clean Face Gas Fireplaces

Power Flame Incorporated

Elite. Unit Heaters. Installation and Commissioning Manual. Tubular Unit Heaters Elite Range

Air Replacement Systems

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

CLEARANCES TO COMBUSTIBLES

ACCELERATE YOUR CURING TIME

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

C1210ES Tankless Water Heater

BEACON/MORRIS RBD SERIES INFRARED RADIANT HEATER

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

KIC Air Curtains. Technical Guide

Crossover. Hybrid Water Heater. High Efficiency. Advanced Heating & Hot Water Systems.

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Up To 99% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY

7 sizes: 55,000, 80,000, 110,000, 155,000, 199,000, 285,000 & 399,000 Btuh. One of a kind design from the inside, out!

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

INFRARED RADIANT TUBE HEATER RSTP15C NATURAL GAS RSTP17C

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu

Field Start-Up Sheet Direct Fired Gas Equipment

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

DIVISION FINNED WATER-TUBE WATER HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

CLIMATE CONTROL PRODUCT GUIDE

Air Replacement Systems

INFRARED RADIANT TUBE HEATER

RIELLO ARRAY. High Efficiency Condensing Boiler MBH.

Omega II SUBMITTAL DATA. Pre Engineered Packages. Products by: COMBUSTION RESEARCH CORPORATION PROJECT: LOW-INTENSITY INFRARED HEATING SYSTEMS

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

NESCO LIMITED PAINTING SYSTEM DIVISION SHOT BLASTING PRETREATMEN PAINT BOOTH ABOUT US: PAINT BOOTH

Photo courtesy of U.S. Navy. ARID-Dry. Restoration and Construction Drying Equipment Mobile Desiccant Dehumidifiers Temporary Humidity Control

DIVISION FINNED WATER-TUBE BOILERS

Transcription:

BANANZA 100% Thermal Efficient, Direct-Fired, Make-up Air Systems For Ventilation, Heating and Curing in Paint Booths and Finishing Areas SPRAY-CURE B-Series Helps reduce cycle time and increase productivity with advanced SPRAY-CURE technology. Can facilitate improved operation and paint job quality through pressurization. Can meet shop space demands with array of configurations. Long lasting unit provided by heavy-duty, corrosion-resistant, galvanized steel construction. Easy maintenance of blower, motor, drives and burners with large access panels. Heaters are listed to ANSI Z83.25/CSA 3.19 direct gas-fired process air heaters. Helps reduce energy costs due to 100% thermal efficiency. 1.800.255.3416 www.bananza.com CANADA: 100% OUTSIDE AIR ONLY

BANANZA B-Series with SPRAY-CURE Designed for the unique needs of the finishing market, BANANZA B-Series air handlers with SPRAY-CURE technology help maintain a pressurized condition in the finishing facility or paint booth. Introducing a controlled amount of fresh, tempered air, can keep dirt and debris out, helping reduce finishing time while improving productivity, operation and finishing quality. The air handlers are sized and designed according to the exhaust rate requirements of the paint booth or finishing facility. SPRAY-CURE units help enhance the performance of the exhaust and filtering system. During the curing cycle, super-heated air is circulated to speed cure time and improve efficiency of the finishing process. Air handlers utilizing recirculation, can deliver high temperatures in cure mode and aid in reduced fuel usage. Additional energy savings can be realized by the unit s 100% thermal efficiency. Proper booth pressurization in the finishing facility or paint booth, helps minimize heat loss. Model B-650 B-1000 B-2000 B-3000 B-4000 B-5000 CFM 4,000-10,000 7,000-14,000 12,000-25,000 25,000-40,000 35,000-47,500 45,000-60,000 Output [MBH]* NG 432-800 456-1,404 1,296-2,700 2,700-4,320 3,780-5,130 4,860-6,480 LPG 346-800 605-1,210 1,037-2,160 2,160-3,456 N/A N/A * 1MBH = 1,000 Btu/h. Output range indicates range at maximum temperature. 100% Thermal Efficient in Curing of Paint, Coatings and Finishes for: Automotive Paint Booths Industrial Components and Parts Finishing RV, Truck, Boat/Marine Paint Booths and Buildings Cabinets and Woodwork Finishing and Varnishing Aircraft Parts Finishing and Paint Hangars Furniture Finishing and Varnishing

SPRAY-CURE Remote Panels to Meet a Variety of A variety of pre-engineered controls help customize the BANANZA unit's operation for a specific process. Remote Panel Basic II (Cure) Basic II (Spray) Digital Dual #1 Used for Curing Paint Yes No Yes Used for Spraying Paint No Yes Yes Discharge Air Temperature F ( C) 120-170 (48.9-76.7) 55-90 (12.8-32.2) 60-90 (15.6-32.2) / 80-180 (26.7-82.2) Discharge temperature remains constant Single analog temperature selection dial. Two temperature selection dials with digital display. Fan ON/OFF Switch Burner ON/OFF Switch Light ON/OFF Switch Yes Yes No SPRAY-CURE Mode Selector Switch No No Yes Indicator Lights Other Controls No No Adjustable speed controls for exhaust fan in spray and cure mode. Burner Flame Modulated by discharge temperature contro Nema 1 Enclosure FAN ON/BURNER OFF Mode FAN ON/BURNER ON Mode FAN/BURNER ON - Spray Mode FAN/BURNER ON - Cure Mode Blower can operate without burner. Air handler Air handler operates continuously, supplying heated make No Yes Yes Yes No Yes

Applications Dual #2 Digital 60-160 Deluxe Digital 55-90 (12.8-32.2) / 120-170 (48.9-76.7) selected on temperature selection dial. wo analog temperature selection dials. 60-160 (15.6-71.1) Single temperature selection dial with digital display. 60-90 (15.6-32.2) / 80-180 (26.7-82.2) Two temperature selection dials with digital display. Yes No Yes Adjustable purge and cure timers. overned by remote temperature selector. Adjustable speed control for exhaust fan and booth pressure gauge. Optional: burner lockout indicator light, remote reset push button and check filter indicator light. Adjustable speed controls for exhaust fan in spray and cure mode and booth pressure gauge. Adjustable timers for purge, cure and cool down. Optional: burner lockout indicator light, remote reset push button and check filter indicator light. perates continuously, supplying make-up air. p air and maintaining constant discharge temperature.

Installation Options BANANZA B-Series air handlers with SPRAY-CURE technology are available in flexible configurations, helping allow for mating to various finishing facilities or paint booths. Units can be mounted indoors or outdoors (building rooftop or side wall locations) and can be used with down draft, semi-down draft and cross draft spray booths. These units can be ideal for retrofit and replacement of old or inefficient units. Paint prep stations can also utilize direct-fired make-up air. Roof Mounted, Horizontal, Bottom Discharge Roof Mounted, Horizontal, Bottom Discharge Booth Mounted, Horizontal, Bottom Discharge Ceiling Suspended, Horizontal, End Discharge Pad Mounted, Horizontal, Top Discharge Pad Mounted, Upright, Side Discharge

Thank you for your business! Installation Code and Annual Inspections: All installation and service of BANANZA equipment must be performed by a contractor qualified in the installation and service of equipment sold and supplied by Bananza and conform to all requirements set forth in the BANANZA manuals and all applicable governmental authorities pertaining to the installation, service, operation and labeling of the equipment. To help facilitate optimum performance and safety, Bananza recommends that a qualified contractor conduct, at a minimum annual inspections your BANANZA equipment and perform service where necessary, using only replacement parts sold and supplied by Bananza. Further Information: Applications, engineering and detailed guidance on systems design, installation and equipment performance is available through BANANZA representatives. Please contact us for any further information you may require, including the Installation, Operation and Service Manual. This product is not for residential use. This document is intended to assist licensed professionals in the exercise of their professional judgment. Bananza 1100 Seven Mile Road NW Comstock Park, MI 49321 Telephone: +1.616.726.8800 Toll Free: 800.255.3416 Fax: +1.616.726.8807 www.bananza.com 2012 Roberts-Gordon LLC All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any means graphic, electronic, or mechanical, including photocopying, recording, taping, or information storage and retrieval systems without written permission of Roberts-Gordon LLC. Printed in U.S.A. BNSCBNA 0412 Rev A