The Optimal Design of Prototype to Replace the Vapor Recovery Unit (VRU) Using Computational Fluid Dynamic Analysis

Similar documents
EXPERIMENTAL INVESTIGATION ON SHELL AND TUBE HEAT EXCHANGER USING SEGMENTAL AND DISC-DOUGHNUT TYPE BAFFLES

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Heat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a

Thermal Analysis of Concentric Tube Heat Exchanger Using Louvered Strip Inserts

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

Theoritical Analysis For Miniature Vapor Compression Cycle Performance Using Microchannel And Finned Tube Condenser

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Analysis of a Condenser in a Thermal Power Plant for Possible Augmentation in its Heat Transfer Performance

PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

Experimental Study And CFD Based Simulation of Closed Loop Pulsating Heat Pipe Using of Refrigerants (R-134a)

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

Effect of operating conditions on performance of silica gel-water air-fluidised desiccant cooler

TRANSACTIONS ON ADVANCEMENTS IN SCIENCE AND TECHNOLOGY (TASTONLINE)

How is the heat transfer?

IMPROVE THE EFFICIENCY OF HEAT EXCHANGER IN OIL COOLER.

PERFORMANCE ENHANCEMENT OF AIR CONDITIONER *

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Compression of Fins pipe and simple Heat pipe Using CFD

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

Design and Development of Water Cooled Condenser for Domestic Refrigerator

As we discussed early in the first chapter that heat can transfer through materials and the surrounding medium whenever temperature gradient exists

Keywords: Triple tube heat exchanger (TTHE), hot water, cold water, CFD simulation.

Global Journal of Engineering Science and Research Management

DESIGN AND ANLYSIS OF MODIFIED HYBRID SOLAR SYSTEM USING NANO FLUIDS

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Gandhinagar Institute of Technology Mechanical Engineering (Thermal Engineering) Semester II. Design of Heat Exchange Equipments [ ]

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Effect of the Use Pattern on Performance of Heat Pump Water Heater

Heat transfer and heating rate of food stuffs in commercial shop ovens

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

a Heat Exchanger using FEA Tool

THE EFFECTS OF HUMIDITY, COMPRESSOR OPERATION TIME AND AMBIENT TEMPERATURE ON FROST FORMATION IN AN INDUSTRIAL FRIDGE *

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

Performance of Shell and Tube Heat Exchanger under Varied Operating Conditions

Development and Application of Micro Channel Heat Exchanger for Heat Pump

Development of Small-diameter Tube Heat Exchanger: Circuit Design and Performance Simulation

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 12, 2016 ISSN (online):

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Experimental study of a novel dew point indirect evaporative cooler

Heat Exchangers. Heat Exchangers 1

Study of R161 Refrigerant for Residential Airconditioning

Performance Study of Triple Concentric Pipe Heat Exchanger

A Novel Heat Recovery System for High Temperature and High Humidity Gas Qing Hao1, a, Meng Si2, b

Measurement of internal pressure and thermal performance in a closed-loop oscillating heat-pipe with check valves (CLOHP/CV)

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger


Design of solar adsorption refrigeration system with CPC and study on the heat and mass transfer performance

Application of Evaporative Cooling in the Building Ventilated by a Solar Chimney

1st City Issues Tongji International Symposium City & Real Estate Risk Management 2010

Mechanical Engineering Department Sheet (1)

SCIENCE CHINA Technological Sciences

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Mallikarjun 1, Anandkumar S Malipatil 2

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

Structure Improvement and Flow Field Analysis of Condenser in Freeze drying Equipment

Thermal Performance of a Loop Thermosyphon

Waghmare Tushar Ramrao, D.S.Nakate

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Enhancement of COP using Nanoadditives in Domestic Refrigerator

Enhancement of COP in Vapour Compression Refrigeration System

A Method of Heat Exchange Structure Optimization of the Cricoid Plastic Parts

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Effect of Inclination Angle in Heat Pipe Performance Using Copper Nanofluid

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Internal flow Patterns of the Horizontal Heat Mode Closed-Loop Oscillating Heat Pipe with Check Valves (HHMCLOHP/CV)

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Enhancement of Round Tube and Flat Tube- Louver Fin Heat Exchanger Performance Using Deluge Water Cooling

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

APPLICATION OF CFD SIMULATIONS FOR LOCATING OUTDOOR UNITS ON HIGH RISE TOWER Basant Kumar Gupta 1, Anand Patil 2

seasons in regions with hot, humid climates. For this reason, a dehumidification system with a radiant panel system needs to be developed. In a former

0Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe

A study of Transient Performance of A Cascade Heat Pump System

Design Optimization of Variable Geometry Microchannel Heat Exchangers

The Experimental Study and Simplified Model of. Water Mist Absorbing Heat Radiation

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Development of Bionic Air Cooler Used in High Temperature Coal Mine

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump

Energy and Exergy Analysis of an Ejector-Absorption Refrigeration Cycle with Using NH3-H2O as the Working Fluids

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852

An Experimental Study on Evacuated Tube Solar Collector for Heating of Air in India Avadhesh Yadav, V.K. Bajpai

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Experimental Study on Performance of Double pipe Length on Instantaneous Air Source Heat Pump Water Heater. Yin Shaoyou 1, a

ANALYSING THE EFFECTIVENESS OF THE HEAT EXCHANGER BY INCREASING OVERALL HEAT TRANSFER COEFFICIENT

Experimental Analysis on Effect of Design Parameters on the Performance of Single Loop Pulsating Heat Pipe

Induction heating with the ring effect for injection molding plates

A Study on the 2-D Temperature Distribution of the Strip due to Induction Heater

Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump ABSTRACT 1. INTRODUCTION

Design and Realization for the Environmental Protection Type of Pig-Farm Model Based on the Sensor Technology

Falling Film Heat Exchangers for Solar Water Heaters

Effect of Height Difference on The Performance of Two-phase Thermosyphon Loop Used in Airconditioning

1, 2

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

Analysis of CPU cooling using liquid with different type of heat sinks

Transcription:

The Optimal Design of Prototype to Replace the Vapor Recovery Unit (VRU) Using Computational Fluid Dynamic Analysis Nattadon Pannucharoenwong 1, Totsaphon Chabuanoi 2 and Chatchai Benjapiyaporn 2*, Snunkhaem Echaroj 3 1 Department of Mechanical Engineering, Faculty of Engineering, Thammasat University 12120 Thailand. 2 Department of Mechanical Engineering, Faculty of Engineering, Khon Kaen University 40002 Thailand. Abstract This paper presents design and compared heat transfer efficiency of different shell and tube type heat exchanger as a technology for replacing the Vapor Recovery Unit (VRU). The Computational Fluid Dynamic (CFD) analysis was performed by the commercial software ANSYS-FLUENT 14.5 to calculate temperature of inlet and outlet of each heat exchanger. The results shows temperature of outer surface of tube U-tube heat exchanger decrease more than fixed tube sheet heat exchanger. Additionally, the temperature of pentane inside U- tube heat exchanger decrease more than fixed tube sheet heat exchanger. The U-tube heat exchanger might be an ideal choice to replace the VRU system. Keywords Vapor Recovery Unit (VRU), heat exchanger, U- tube heat exchanger, Fixed tube sheet heat exchanger, Computational Fluid Dynamic INTRODUCTION Vapor of fuel oil is considered as volatile organic compounds (VOCs) that have an effect on human skin, eyes and the respiratory system. One of the most hazardous VOCs is emitted from benzene which have been known to cause leukemia [1]. Besides the effect on human health, VOCs can increase ozone in atmosphere. So it is important to control ozone and benzene level to a minimum. For this research we will use the concept of a Vapor Recovery Unit to reduce pollution by controlling vapor emission level in the range of 10 to 35 mg/l. According to the currently regulation, VOCs release from oil terminal must not be more than 17 mg/l. For this reason most we must install Vapor Recovery Unit (VRU) in every oil terminal. Now the installation cost is about 40-50 million baht per system. Currently, the Petroleum Authority of Thailand have idea to design and build VRU by themselves. From conducting a literature review, Chasik Park et al.[2] has collected research relate to design of heat exchanger, Li Shi et al.[3], Enxi Lu et al.[4], Bin Gao et al.[5], Ming Pan et al.[6] has designed and constructed of pototype heat exchanger for performance testing, Guo-Yan Zhou et al.[7], Jian Wen et al.[8],aniket Shrikant Ambekar et al.[9], Sirous Zeyninejad Movassag et al.[10], Ender Ozden et al.[11], Farhad Nemati Taher et al.[12], Jie Yang et al.[13], Najla El Gharbi et al.[14], Mustapha Mellal et al.[15] use Computational Fluid Dynamics (CFD) simulate working for find performance of heat exchager, Jian-feng Zhou et al.[16], Jian-Feng Yang et al.[17], Lu Ma et al.[18], Koichi Nakaso et al.[19], Jian Wen et al.[8], Yonghua You et al.[20], Yonggang Lei et al.[21] has changed design parameters and use numerical simuration compare performance of heat exchanger, Mohsen Amini et al.[22], Salim Fettaka et al.[23], Hassan Hajab dollahi et al.[24], Jie Yang et al.[25], Kai Wang et al.[26] have optimized design parameters of heat exchanger with total cost and performance are objective function This research will reduce cost and size of the equipment for installation of the vapor recovery device by using heat transfer principle to condense oil vapor to liquid. The designed Vapor Recovery Unit (VRU) can be used to control VOCs before being released into the environment. Therefore, the first objective of this paper is to design a shell and tube type heat exchanger to install at VRU system and use theoretical calculation in combination of ANSYS- FLUENT 14.5 program. The second objective is to analyze the design using ANSYS- FLUENT 14.5 according to heat transfer theories. The last objective is to analyze the obtained results using fixed tube sheet heat exchanger and U-tube heat exchanger models. MATERIAL AND METHODS Designing the Heat Exchanger using the Governing equations. In designing a heat exchanger, we studied about the possibility and the limits of the VRU system as shown in Figure 1. So, the equations used were 1 8 as following. Mass flow rate: m ρav ρv (1) Where ṁ = Mass flow rate (kg/s), ρ = Density of substance (kg/m 3 ), A = Area (m 2 ), v = Velocity (m/s 2 ), V= Volume flow rate (m 3 /s) Log mean temperature: ΔT 1 = T hot,in - T cold,out ΔT 2 = T hot,out T cold,in (2) ΔT lm = (ΔT 1-ΔT 2)/(ln(ΔT 1/ΔT 2)) 1623

Overall heat transfer coefficient: 1 U d d ) d o o ln( 1 1 d d i h h 2k d di h o i h o (3) o od w id i Where U o = Overall heat transfer coefficient (W/m 2 C), h o = Outside fluid film coefficient (W/m 2 C), h i = Inside fluid film coefficient (W/m 2 C), h od = Outside fouling factor coefficient (W/m 2 C), h id = Inside fouling factor coefficient (W/m 2 C), k w = thermal conductivity of tube wall material(w/m C), d i = Tube inside diameter (m), d o = Tube outside diameter (m) Rate of net heat transfer: Where Q mcpδt ml AUoΔT lm (4) Q dot = Rate of net heat transfer (kj/s), ṁ = Mass flow rate (kg/s), c p = Specific heat of substance (kj/kg K), L = Latent hear of substance (kj/kg), U o = Overall heat transfer coefficient (W/m 2 K), ΔT lm = Log mean temperature ( C) Surface area of tube: At πd o L (5) Where A t = Surface area (m 2 ), d o = Tube outside diameter (m), L = Length of tube (m) Number of tube: A Nt (6) A t Velocity: m V (7) π 2 4 ρd i Where v = Velocity (m/s), ṁ = Mass flow rate (kg/s), ρ = Density of substance (kg/m 3 ), d i = Tube inside diameter (m) FINDING PARAMETERS AND CONDITIONS A water-water 1 2 pass shell and tube heat exchanger is designed considering the data in the following Table 1. Figure 2a show using SOLIDWORK program design fixed tube sheet heat exchanger. Figure 2b show using SOLIDWORK program design U-tube heat exchanger. Figure 2c show the tube arrangement of heat exchanger. Table 1: Data for design of shell and tube heat exchanger. Property Unit Value Shell side fluid-hot pentane T HI o C 40 T HO o C 18 Density kg/m 3 3.87946 Specific heat capacity kj/kg K 1.732838889 Viscosity kg/ms 11700000 Conductivity W/m K 0.04 Fouling factor m 2 K/W 0.0002 Flow rate kg/s 0.003879463 Tube side fluid-cold water T CI o C 12 T CO o C 25 Density kg/m 3 998.46 Specific heat capacity kj/kg K 4.1904 Viscosity kg/ms 0.0012394 Conductivity W/m K 0.5836 Fouling factor m 2 K/W 0.0002 Flow rate kg/s 0.029268063 Where A = Area (m 2 ), A t = Surface area (m 2 ) 1624

(a) Fixed tube sheet heat exchanger. (b) U-tube heat exchanger. (c) Tube arrangement Figure 1. Design by using SOLIDWORK program: (a) fixed tube sheet heat exchanger. (b) U-tube heat exchanger. (c) Tube arrangement of heat exchanger. Table 2: Inner and outer diameter for Copper tube Nominal Outside diameter (OD) Inside diameter (ID) [in(mm)] size [in (mm)] Type K Type L Type M 5/8 3/4 (19.05) 0.652(16.561) 0.668(16.967) 0.690(17.526) 3/4 7/8 (22.225) 0.745(18.923) 0.785(19.939) 0.811(20.599) 1 9/8 (28.575) 0.995(25.273) 1.025(26.035) 1.055(26.797) (a) U-tube heat exchanger design (b) Fixed tube sheet heat exchanger design Figure 2. (a) U-tube heat exchanger design (b) Fixed tube sheet heat exchanger design For Copper tube, we use type L Copper tube ¾ inches size due to the fact that Type L has a thinner pipe wall section, and is used in residential and commercial water supply and pressure applications listed in Figure 2a shows U-tube heat exchanger design, Figure 2b shows fixed tube sheet heat exchanger design. RESULTS Optimization of heat exchanges were performed to decide which type of heat exchanger is most effective for Results of heat exchanger from simulation Use ANSYS- FLUENT 14.5 Software simulation compare that the fixed tube sheet heat exchanger and U-tube heat exchanger while inlet temperature of water is approximately 25 o C and the inlet temperature of Pentane is approximately 40 o C. The results in Figure 3a show the temperature of outer surface of tube fixed tube sheet heat exchanger. Figure 3b show the temperature of outer surface of tube U-tube heat exchanger. It is observed from Figure 3 that temperature of outer surface of tube U-tube heat exchanger decrease more than fixed tube sheet heat exchanger. Figure 4 demonstrated temperature of fuel vapor along the shell and tubes inside the two different heat exchangers. It can be 1625

observed that the temperature of vapor inside the U-tube model reduced faster compared with fixed tube sheet model. This indicate the superior condensation efficiency of the U-tube model compared with the fixed tube sheet model. might be an ideal choice to replace VRU system because the U- tube heat exchanger can condensed all Pentane vapor into oil. ACKNOWLEDGEMENTS The researchers would like to thank the Petroleum Authority of Thailand Phra Khanong, Energy Management and Conservation Office (KKU EMCO), Khon Kaen University for providing facilities for this research. Additionally, researchers would like to thank Faculty of Engineering Thammasat University for providing research funds. (a) Fixed tube sheet heat exchanger (b) U-tube heat exchanger Figure 3. Temperature of outer surface of tube: (a) Fixed tube sheet heat exchanger (b) U-tube heat exchanger (a) Fixed tube sheet heat exchanger REFERENCES [1] Snyder, R., Leukemia, and Benzene, 2012, International Journal of Environmental Research and Public Health., 9(8): pp. 2875-2893. [2] C, Park., H, Lee., Y, Hwang., and R, Radermacher., 2015, Recent advances in vapor compression cycle technologies, Int. J. Refrig., vol. 60, pp. 118 134. [3] L. Shi and W. Huang, 2014, Sensitivity analysis and optimization for gasoline vapor condensation recovery, Process Saf. Environ. Prot., vol. 92, no. 6, pp. 807 814. [4] E. Lu, H. Zhang, and X. Zhu, 2000, A novel design for vapor recovery units, Comput. Chem. Eng., vol. 24, no. 2 7, pp. 1317 1322. [5] B. Gao, Q. Bi, Z. Nie, and J. Wu, 2015, Experimental study of effects of baffle helix angle on shell-side performance of shell-and-tube heat exchangers with discontinuous helical baffles, Exp. Therm. Fluid Sci., vol. 68, pp. 48 57. [6] M. Pan et al., 2013, New insights to implement heat transfer intensification for shell and tube heat exchangers, Energy, vol. 57, pp. 208 221. (b) U-tube heat exchanger Figure 4. Temperature of vapor inside tube (a) Fixed tube sheet heat exchanger (b) U-tube heat exchanger CONCLUSIONS AND DISCUSSION The simulation from ANSYS- FLUENT 14.5 Software to compare U-tube heat exchanger and fixed tube sheet heat exchanger. The result show the temperature of pentane inside tube of U-tube heat exchanger decrease more than fixed tube sheet heat exchanger, which lading to lower pentane condensation efficiency in fixed tube sheet heat exchanger than U-tube heat exchanger. Therefore, U-tube heat exchanger [7] G. Y. Zhou, J. Xiao, L. Zhu, J. Wang, and S. T. Tu, 2015, A Numerical Study on the Shell-Side Turbulent Heat Transfer Enhancement of Shell-and-Tube Heat Exchanger with Trefoil-Hole Baffles, Energy Procedia, vol. 75, pp. 3174 3179. [8] J. Wen, H. Yang, G. Jian, X. Tong, K. Li, and S. Wang, 2016, Energy and cost optimization of shell and tube heat exchanger with helical baffles using Kriging metamodel based on MOGA, Int. J. Heat Mass Transf., vol. 98, pp. 29 39. [9] A. S. Ambekar, R. Sivakumar, N. Anantharaman, and M. Vivekenandan, 2016, CFD simulation study of shell and tube heat exchangers with different baffle segment configurations, Appl. Therm. Eng., vol. 108, pp. 999 1007. [10] S. Zeyninejad Movassag, F. Nemati Taher, K. Razmi, and R. Tasouji Azar, 2013, Tube bundle replacement for segmental and helical shell and tube heat exchangers: Performance comparison and fouling investigation on 1626

the shell side, Appl. Therm. Eng., vol. 51, no. 1 2, pp. 1162 1169. [11] E. Ozden and I. Tari,2010, Shell side CFD analysis of a small shell-and-tube heat exchanger, Energy Convers. Manag., vol. 51, no. 5, pp. 1004 1014. [12] F. Nemati Taher, S. Zeyninejad Movassag, K. Razmi, and R. Tasouji Azar, 2012, Baffle space impact on the performance of helical baffle shell and tube heat exchangers, Appl. Therm. Eng., vol. 44, pp. 143 149. [13] J. Yang, L. Ma, J. Liu, and W. Liu, 2014, Thermalhydraulic performance of a novel shell-and-tube oil cooler with multi-fields synergy analysis, Int. J. Heat Mass Transf., vol. 77, pp. 928 939. [14] N. El Gharbi, A. Kheiri, M. El Ganaoui, and R. Blanchard, 2015, Numerical optimization of heat exchangers with circular and non-circular shapes, Case Stud. Therm. Eng., vol. 6, pp. 194 203. [15] M. Mellal, R. Benzeguir, D. Sahel, and H. Ameur, 2017, Hydro-thermal shell-side performance evaluation of a shell and tube heat exchanger under different baffle arrangement and orientation, Int. J. Therm. Sci., vol. 121, pp. 138 149 [16] J. F. Zhou, S. W. Wu, Y. Chen, and C. L. Shao, 2015, Semi-numerical analysis of heat transfer performance of fractal based tube bundle in shell-and-tube heat exchanger, Int. J. Heat Mass Transf., vol. 84, pp. 282 292. [17] J. F. Yang, M. Zeng, and Q. W. Wang, 2015, Numerical investigation on combined single shell-pass shell-andtube heat exchanger with two-layer continuous helical baffles, Int. J. Heat Mass Transf., vol. 84, pp. 103 113. [18] L. Ma et al., 2017, Numerical study on performances of shell-side in trefoil-hole and quatrefoil-hole baffle heat exchangers, Appl. Therm. Eng., vol. 123, pp. 1444 1455. [19] K. Nakaso, H. Mitani, and J. Fukai,2015, Convection heat transfer in a shell-and-tube heat exchanger using sheet fins for effective utilization of energy, Int. J. Heat Mass Transf., vol. 82, pp. 581 587. [20] Y. You, A. Fan, X. Lai, S. Huang, and W. Liu, 2013, Experimental and numerical investigations of shellside thermo-hydraulic performances for shell-and-tube heat exchanger with trefoil-hole baffles, Appl. Therm. Eng., vol. 50, no. 1, pp. 950 956. [21] Y. Lei, Y. Li, S. Jing, C. Song, Y. Lyu, and F. Wang, 2017, Design and performance analysis of the novel shell-and-tube heat exchangers with louver baffles, Appl. Therm. Eng., vol. 125, pp. 870 879. [22] M. Amini and M. Bazargan, 2014, Two objective optimization in shell-and-tube heat exchangers using genetic algorithm, Appl. Therm. Eng., vol. 69, no. 1 2, pp. 278 285. [23] S. Fettaka, J. Thibault, and Y. Gupta,2013, Design of shell-and-tube heat exchangers using multiobjective optimization, Int. J. Heat Mass Transf., vol. 60, no. 1, pp. 343 354. [24] H. Hajabdollahi, M. Naderi, and S. Adimi, 2016, A comparative study on the shell and tube and gasket-plate heat exchangers: The economic viewpoint, Appl. Therm. Eng., vol. 92, pp. 271 282. [25] J. Yang, A. Fan, W. Liu, and A. M. Jacobi, 2014, Optimization of shell-and-tube heat exchangers conforming to TEMA standards with designs motivated by constructal theory, Energy Convers. Manag., vol. 78, pp. 468 476. [26] K. Wang, X. C. Tu, C. H. Bae, and H. B. Kim, 2015, Optimal design of porous baffle to improve the flowdistribution in the tube-side inlet of a shell and tube heat exchanger, Int. J. Heat Mass Transf., vol. 80, pp.865 872. 1627