MANUAL CLEANING IS A VERY IMPORTANT PART OF THE

Similar documents
ULTRASONIC (SONIC) CLEANING ENHANCES THE INSTRUMENT

STERILIZATION IS A KEY RESPONSIBILITY OF THE INSTRUMENT

STERILIZATION IS A KEY RESPONSIBILITY OF THE INSTRUMENT

DEVICES THAT HAVE NOT BEEN ADEQUATELY CLEANED CANNOT

Decontamination. CIS Self-Study Lesson Plan Lesson No. CIS 244 (Instrument Continuing Education - ICE)

THE BASICS OF DECONTAMINATION

When you sterilize an instrument set, you know what the standards are.

2015 Myco Industries, Inc Fax:

Instructions for Use Spinal Punches IFU

CLEANING INSTRUCTIONS

CLEANING AND HANDLING OF WRIGHT INSTRUMENTS

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

GETINGE CLEAN DETERGENT RANGE GET MAXIMUM PERFORMANCE VALIDATED

Integra Salto Talaris and Integra XT Non-Sterile Device Reprocessing. Instructions for Use. 4. Manual Cleaning Instructions

THE ULTRASONIC DISRUPTION OF ORGANIC SOIL ON COMPLEX INSTRUMENTATION

Accessories. Maybachstraße. Symmetry Fax: Revised 10/15

Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

The Principles, The Process, and The Results:

Surgical Instrument Cleaning Process

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

Recommendations for cleaning, decontamination and sterilisation. devices

RECOMMENDATIONS FOR CLEANING DEVICES

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

FLASH PAK STERILIZATION CONTAINER SYSTEM

Cleaning & Sterilization

CONVENTUS CAGE TM - DR Procedure Instruments Instrument Tray. Equipment Cleaning and Sterilization

Made in USA. Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216, USA (904)

Processing instructions for the Ligamys suture forceps

Operating / User Manual

IMPORTANT INFORMATION ON THE DEPUY SYNTHES

MARSHALLTOWN MEDICAL AND SURGICAL CENTER LAUNDRY/LINEN SERVICES. SUBJECT: Infection Control POLICY NO: 106

Instructions for care, maintenance, cleaning and sterilization of Smith & Nephew orthopaedic devices

User Guide for Reprocessing of the SUPER VIEW Wide Angle Viewing System Sterilizable Components and Accessories

Technical Data Monograph. Reliance Vision Single Chamber Washer/Disinfector

SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System

Rigid Reusable & Single use Sigmoidoscopes, Anoscopes, and Accessories ENGLISH 1. Perform reprocessing immediately after each use.

EMAX 2 PLUS AND XMAX CLEANING AND STERILIZATION BASKET. Mechanical/Automated Cleaning and Sterilization Guide in a Variety of Applications

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

Aesculap Implant Systems

V. Mueller. V. Mueller Reusable Devices: Cleaning and Sterilization Guide USA. Rx Only

INSTRUCTIONS FOR USE & STERILIZATION FOR INSTRUMENTS

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches

INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES

Presenter: Malcolm McLaughlin Date: 04/04/2019. A Review of Medical Device and Optical Critical Cleaning

Call our hotline at for all your instrument care and detergent questions. Medline Super Concentrates

WORLD LEADERS IN ADVANCED SURGICAL INSTRUMENT REPROCESSING TECHNOLOGY

I.F.U Re/Processing Reusable Medical Devices

Disclosure. Today. Why are we here today. The College of Clean The Foundation Part 1. This is why you are here today. Watch this short video 3/26/2015

Technical Data Monograph. AMSCO 3052 Single-Chamber Washer/Disinfector AMSCO 5052 Single-Chamber Washer/Disinfector

Instructions for Use: Endoplus Modular Handle Assemblies, Multi-Use Scissors Inserts, Reusable Inserts

MARSHALLTOWN MEDICAL AND SURGICAL CENTER ENVIRONMENTAL SERVICES. SUBJECT: Room Cleaning Occupied Room (All Areas) PROCEDURE NO: 032

HOMES AND SENIORS SERVICES. APPROVAL DATE: April 2004 REVISION DATE: March 2016 REVISION DATE: March 2017 REVIEW DATE: November 2018

TRAINING AND EQUIPMENT MANUAL 311 PERSONAL PROTECTIVE EQUIPMENT FIREFIGHTER PROTECTIVE CLOTHING CLEANING PROCEDURES EFFECTIVE: OCTOBER 2007

Cleaning and disinfecting

For routine maintenance of polished granite installations with a cleaner and protector:

SUGGESTED POLICY FOR THE MONITORING AN ULTRASONIC CLEANER DAILY

DZ5080 US Index01 19/09/07 10:50 Page 2

WORK IN THE DISINFECTION ROOM WITH WASHER-DISINFECTORS

CLEANING OF INSTRUMENTS

STERITITE INSTRUCTIONS FOR USE

CARE & CLEANING GUIDE. Bathroom & Kitchen Products

Lower Your Costs. Expand Your Flexibility.

Aesculap Implant Systems

SUBJECT: Monitoring the performance of a sonic cleaners and/or automatic washers cleaning ability for lumens/cannulated items daily.

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

Washroom care programs

Glass and Dishwashers 402/452/502. (original instructions) (incl. Australian /502) Starting from Serial No.:

U S E R G U I D E. Home Respiratory Equipment Cleaning Guide. Health Information

Caution: Federal U.S. law restricts this device to sale by or on the order of a physician.

Developing the Solutions For You. Veterinary 2018 VETERINARY PRODUCT CATALOG

ENDOSCOPE DECONTAMINATION : Where are we now!

Device Reprocessing Checklist Scoring Matrix 1=low 5=high

Cleaning and Sterilisation for Burs, accessories and filling material

Lower Your Costs. Expand Your Flexibility.

Operations and Safety Manual

Jennings Street School

Processing (cleaning, disinfection and sterilization) of instruments from Smith & Nephew Orthopaedics AG

Sterile Processing. Knowledge, Skills, Competencies. Terri Goodman, PhD, RN

Cleaning and Sterilization for Instruments & Posts

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

Cleaning Telemonitor & Accessories

Steam Sterilization and Sterility Assurance in Health Care Facilities ANSI/AAMI ST79. Suzanne Latta, CSPDT. Education Materials Coordinator

Manual Cleaning? SOBECC Round Table: Manual and Automated Cleaning Methods th July 2012

L eather Care & Cleaning

Technical Data Monograph. The Instrument Protection Properties of Prolystica Enzymatic Presoak and Cleaner and other Enzymatic Products

Instrument Cleaning Chemistries Automated Washing Process

CARE & CLEANING GUIDE. Bathroom & Kitchen Products

Processing Instructions. Cleaning so easy.

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

How To Clean Stainless Steel Sink Step By Step Guideline

OXYGEN CONCENTRATORS Information For Our Customers

Guidelines for Cleaning, Disinfecting and Sterilizing Medela Healthcare Products REPROCESSING GUIDE. Precious life Progressive care

ON TRACK Reprocessing In-service / Competency for CF/PCF/GIF Endoscopes (EVIS, EXERA, EXERA II)

UNSIGNED HARDCOPY NOT CONTROLLED

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE

PERFORM Operating Document

ASSESSMENT REPORT ENDOZIME INSTRUSPONGE

Transcription:

CRCST Self-Study Lesson Plan Lesson No. CRCST 160 (Technical Continuing Education - TCE) Sponsored by: by Robert Glover, AS, CRCST, CIS Sterile Processing Aide Riverside Hospital, Va. Manual Cleaning LEARNING OBJECTIVES 1. Discuss the need and importance of manual cleaning 2. Describe the appropriate cleaning solution and cleaning implements for the manual cleaning process 3. Describe manual cleaning techniques MANUAL CLEANING IS A VERY IMPORTANT PART OF THE decontamination process, and it is often performed incorrectly. Device labeling specifies cleaning methods, which have been validated by the manufacturer and are regulated by the US Food and Drug Administration (FDA). The medical device manufacturer s instructions for use (IFU) must be followed. All medical devices entering the healthcare facility must be cleaned before use, disinfection or sterilization. New and repaired devices may have manufacturing soils on them, and must be decontaminated upon receipt. Also, loaned instrumentation must be decontaminated and sterilized because it is not known how the instrumentation was processed at another facility, and also because the devices were transported in an uncontrolled environment. This lesson addresses these and other factors, as well as the steps that lead to successful manual cleaning. OBJECTIVE 1: DISCUSS THE NEED AND IMPORTANCE OF MANUAL CLEANING Because medical procedures require a wide range of reusable devices and instrumentation, each item presents unique challenges that must be considered before reprocessing can take place. Central Service (CS) technicians should possess technical and critical thinking skills and a comprehensive understanding of potential challenges; this includes being aware of proper cleaning procedures and the delicacy and complexity of medical devices and instruments. The IFU will provide pertinent information regarding instrument/equipment disassembly, precautions, inspection points, types of detergents to use if an item can be submerged, and more. For example, most power equipment cannot be submerged because it would result in equipment malfunction. It is the responsibility of each technician to protect the patient and community by consistently delivering safe medical devices. Instruments should be manually cleaned, per the IFU, prior to mechanical cleaning and whenever the manufacturer states that manual cleaning is the cleaning process of choice. Even instrumentation perceived as clean may harbor gross soil and pathogens that could infect the technician This series of self-study lessons on CS topics was developed by the International Association of Healthcare Central Service Materiel Management (IAHCSMM). Purdue University s Extended Campus and IAHCSMM both offer grading opportunities. Earn Continuing Education Credits: Online: Visit www.iahcsmm.org for online grading at a nominal fee. By mail: For written grading of individual lessons, send completed quiz and $15 to: PEC Business Office, Purdue University, Stewart Center Room 110, 128 Memorial Mall, West Lafayette, IN 47907-2034. Scoring: Each quiz graded online at www.iahcsmm.org or through Purdue University, with a passing score of 70% or higher, is worth two points (2 contact hours) toward CRCST re-certification (12 points). Subscription Series: From January 1 to June 30 each year, Purdue Extended Campus offers an annual mail-in or online self-study lesson subscription for $75 (six specific lessons worth 2 points each toward CRCST re-certification of 12 CE). Call 800.830.0269 for details. For More Information: IAHCSMM provides online grading service for any of the Lesson Plan varieties. Purdue University provides grading services solely for CRCST and CIS lessons. Direct any questions about online grading to IAHCSMM at 312.440.0078. Questions about written grading are answered by Purdue University at 800.830.0269.

CRCST Self-Study Lesson Plan or patient; therefore, it is only appropriate that each soiled instrument be targeted with proper cleaning methods and handled with the utmost care before further processing. The efficacy of the cleaning process is heavily reliant upon vigilant manual cleaning and inspection because a medical instrument cannot be successfully disinfected or sterilized without the removal of bioburden. The goal of manual cleaning is to remove residual soil after the pre-cleaning process by applying friction with the appropriate cleaning tools and solutions. OBJECTIVE 2: DESCRIBE THE APPROPRIATE CLEANING SOLUTION AND CLEANING IMPLEMENTS Manual cleaning is performed in the decontamination area and should be done as soon as possible to prevent debris from drying on the instrument and also to prevent the development of biofilm. Biofilm is an extracellular, slimy film produced by bacteria that adheres to instrument surfaces and can begin forming within minutes. If instruments were not pre-cleaned/soaked at the point of use, they may contain dried gross soil and biofilm, which will make the cleaning process more difficult. Once instruments are received in the decontamination area, they should be sorted and the manual cleaning process should begin. A three-sink arrangement is needed; the first is a wash sink with water and detergent or enzymatic cleaner. The cleaning solution should be clean and changed when it appears soiled, which may be after one use. The middle sink is used to rinse the items. After an item is cleaned, it must be thoroughly rinsed to remove debris and detergent residue. Rinse water should be changed frequently to prevent the buildup of cleaning chemicals and debris that may reattach to the item being rinsed. The final sink is used for a treated (critical) rinse water to prevent instrument spotting and remove minerals, dissolved solids and some microorganisms that are present in untreated water. Instruments should be rinsed with cold water to remove pre-soak chemicals (if used), prevent coagulation of blood and help remove gross debris. Instruments that can be submerged should be soaked in the appropriate cleaning solution. There are two basic types of cleaning chemicals: enzymatic products and detergents. Enzymatic detergents are commonly used since they are low-foaming and formulated to facilitate the breakdown of biomolecules (any molecule present in living organisms, including large macromolecules). Essentially, enzymes are proteins that act as catalysts to speed up chemical reactions. Protease is an enzyme responsible for the breakdown of blood, feces, mucous and albumin. Lipase breaks down fatty deposits such as bone marrow and adipose tissue. Amylase breaks down starch and lipase-dissolved fats. Multi-enzymatic cleaners contain several or all of these enzymes. These enzymes require the correct temperature and dilution to work optimally. Water temperature is usually between 900 and 1400 F; it is important to follow the enzymatic cleaner s IFU for its specific temperature range. If the water temperature is too cold, it will inactivate the enzyme. Too hot temperatures will cause the enzymes to break down. Detergents contain emulsifiers, surfactants and chelating agents. When used properly, they penetrate and remove soil from instruments and keep soil in suspension. Detergents are designed for specific tasks and should be selected based upon the specific cleaning need. While using the correct enzyme or detergent is important, the correct detergent or enzyme dilution is also important. If too much is used, it can be difficult to rinse off and may leave a residue. If too little is used, the cleaning solution may not be effective. Again, prolonged cleaning delays should be avoided to prevent debris from drying and biofilm from forming. Cleaning solutions work best when gross soil has not dried. Pre-soak dampening agents are available and, when used, allow for much more efficient cleaning. NeutralpH cleaning agents are the most suitable for cleaning instruments; however, it is important to check the chemical s IFU to ensure the correct ph for the detergents is being used. If uncertainty arises regarding proper cleaning practices for a medical instrument or device, the manufacturer can provide additional detailed information to assist with cleaning. Technicians should always follow the manufacturer s IFU. Water quality is a very important part of the cleaning solution as it can impact the effectiveness of the detergent or enzymatic cleaner, or leave residue on the instrumentation. Using certain methods to treat water to clean instruments can help ensure that water impurities, mineral deposits, dissolved gases, particles and organic and non-organic chemicals are not present and do not compromise the cleaning process. If treated (critical) water is not used, the contaminants will affect the acidity/alkalinity and conductivity, create an imbalance of halogens and dissolved gases, and perhaps even contain algae, bacteria or parasites. Treated water can be derived from several processes: granular activated charcoal, filters, distillation, deionization and reverse osmosis. Granular activated charcoal is a form of carbon that is processed to have small, low-volume pores that increase the surface area; this allows purification via adsorption or chemical reactions. Filters are produced by manufacturers to reduce the presence of sediments, odor and contaminants. Distillation removes gases, distilled solids and organic materials. Organic materials consist of pyrogens (substance

CRCST SELF-STUDY LESSON PLAN that produces a fever), bacteria and endotoxins (toxins in bacteria that are released when the cell disintegrates). Deionization removes total dissolved solids using ion exchange resins that control the electrical charge of ions in the water. It is important to note that this method of water purification does not remove organic particles. Reverse osmosis removes minerals and a large percentage of dissolved solids and organics, including salt, bacteria, pyrogens, endotoxins halogens, and transitional and earth metals. Note: Dissolved gases will still be present. Cleaning Tools Industry guidelines stress the importance of choosing the correct size and type of cleaning tools for cleaning a medical device or instrument. The most common cleaning tools found in the decontamination area are brushes, cleaning cloths and sponges. Brushes are either disposable or reusable. Disposable brushes are discarded after one-time use. Reusable brushes are cleaned after each use and disinfected or sterilized at least once a day. When inspecting a brush, technicians should be critical of worn, frayed bristles, kinks and overall cleanliness. Kinks inhibit the cleaning process by preventing the brush bristles from making proper contact with the instrument s interior walls. Twisted stainless steel-style brushes are used to clean lumens. The twisted stainless steel-style handles come either looped or non-looped. A looped-end handle permits hanging and allows for faster drying. A non-looped end brush allows the technician to pull the entire brush through the lumen. Antibacterial bristles are available and are resistant to the growth of bacteria, yeasts and molds; however, they do not fully prevent them from forming. Cleaning cloths must be clean and low-linting or lint-free to prevent cross contamination and reduce the risk of fibers being left on instruments. These should be changed regularly or whenever they become visibly soiled or stained. Sponges can also be used, but because they are impossible to clean and sterilize, only single-use sponges should be used. Sponges should also be replaced at least daily or if visibly soiled. Some sponges are impregnated with detergents and must be used according to their manufacturer s IFU. OBJECTIVES 3: DESCRIBE MANUAL CLEANING TECHNIQUES Wearing the correct personal protective equipment (PPE) while working in the decontamination area is a basic requirement for any type of cleaning process. Properly-used PPE protects the technician from splashes and aerosols during the manual cleaning process. Cannulated instruments (suctions, sleeves, sheaths, etc.) can appear to have a clean exterior, but may harbor residual gross soil from surgical procedures inside the lumened area. It is suggested for all cannulas to be soaked vertically to ensure that lumens have complete contact with the cleaning solution; however, if horizontal soaking is the only option, lumens should be submerged and the lumen should be filled with the soaking solution. To internally clean a cannula, the correct brush must be chosen to remove all gross soil. Brushes are provided in different configurations, materials, lengths and diameters to accommodate instrumentation, and choosing the proper brush depends upon the type of instrument being cleaned, the type of gross soil present and, above all, the manufacturer s recommendations. To properly remove gross soil, the brush must have the proper diameter to contact and exert friction within the internal walls. A brush that is too small will not contact all internal surfaces, rendering the instrument soiled. If a brush that is too large is used, it will either not fit into the lumen or will cause damage to the device or bristle breakage. Twisted metal-tip brushes are the preferred choice for cleaning flat surfaces and instrument exteriors. Brushes with a protective cover on the tip are the appropriate choice for cleaning lumens so they do not scratch the interior of the lumen. Fan-tipped brushes contact surfaces of the very end of the lumen, which makes them effective for cleaning a closed-ended lumen. Brush length should be long enough to extend though the instrument, but short enough to maintain user control. To brush the internal cannula, the brush should extend through the cannula until it exits the other end (pushing through the lumen in a twisting motion multiple times to help reach all surfaces within the lumen walls and ensure the exit of gross soil). Brush bristles should be inspected for cleanliness and any debris should be removed so it is not reintroduced into the instrument before being pulled back through the lumen. This process should be repeated until the bristles come out clean. If gross soil is present on the brush, it should be removed before pulling the brush back through the lumen. Broken bristles are an extremely hazardous fomite. If they go unnoticed during assembly, they may end up inside the patient during surgery. After the cannula is brushed, it should be flushed with the cleaning solution and followed by rinse water flushes. The toothbrush-style brush is intended for more rigorous cleaning, such as for external surfaces and hinged instruments; a brush with nylon toothbrush bristles is softer and more flexible, and is the preferred choice for cleaning soft metal instruments. Hinged instruments have box locks, serrations, jaws and ratchets that must be thoroughly cleaned. Hinged instruments should always be placed in the sink in the fully opened position. This allows for more efficient cleaning, even in difficult-to-clean areas such as box locks and serrations.

CRCST Self-Study Lesson Plan Multi-part instrumentation must be disassembled. Brushing should be done in a to-and-fro motion underwater to prevent the occurrence of aerosols. Some instrumentation has movable parts that should be articulated or moved during the cleaning process to ensure all surfaces are thoroughly cleaned. The surface should be continually inspected to ensure all debris is removed. Some instrumentation, such as a lens or plastic-coated device, has fragile surfaces that cannot withstand the rigors of a brush. Clean, low-linting cloths or singleuse sponges should be used to clean these surfaces. Once the instruments have been cleaned, they must be rinsed in accordance with the IFU. Typically, they are first rinsed in tap water, followed by a rinse in treated (critical) water. Drying is the next step for a completely manually-cleaned instrument. Clean, lintfree or low-linting cloths should be used to completely dry the item. For lumened items or complex instruments that are difficult to dry with a cloth, instrument air should be used. Some lumened devices are fragile, so it is important to review the IFU for forced air limit of pressure. It is important to note that some instruments, such as flexible endoscopes and robotic instruments, have an upper limit of pressure. After using the pressure nozzle, it should be wiped, disinfected and allowed to dry before the next use. After manual cleaning, the instrumentation should be inspected to ensure the removal of debris and identify any damage (e.g., broken instrumentation, staining, loose screws). Lighted magnification should be used for visual inspection for fine, delicate and complex instrumentation. Damaged instruments should be tagged for repair or replacement. If one s facility performs cleaning verification for manuallycleaned instruments, that process will be performed before the instruments are passed to the preparation and packaging area. At times, instrumentation may become stained or rusty. These defects may be removed with a stain and rust remover, after the manual cleaning process. Using a stain and rust remover will restore the luster to the stainless-steel instrument. A soaking solution should be prepared according to the stain and rust remover s IFU. Note: It is important to follow the dilution and soak time exactly to prevent damage to the instrument. This solution removes hard water deposits, rust scale, discoloration, mineral and detergent buildup. After soaking the instrument, it should be inspected to ensure the stain has been removed. If so, it should be re-cleaned and sent on to the preparation and packaging area. If the rust and stain cannot be removed, the problem should be brought to the attention of the supervisor who can help determine whether the instrument should be sent for repair or replaced. Some IFU include a low-level disinfection process before certain instruments are passed onto the clean side. CONCLUSION Cleaning is an important part of the sterilization process. The medical device manufacturer s IFU must be diligently followed to prevent damage to the device and ensure all surfaces are thoroughly cleaned. All components of the cleaning process are important, beginning with the cleaning solutions and cleaning implements to be used. CS technicians must have the skills and knowledge to perform cleaning functions that results in a clean medical device. RESOURCES Association for the Advancement of Medical Instrumentation. ANSI/AAMI ST79:2017, Comprehensive guide to steam sterilization and sterility assurance in health care facilities. International Association of Healthcare Central Service Materiel Management. 2016. Central Service Technical Manual, 8th Edition, Chapter 8. IAHCSMM ACKNOWLEDGES THE FOLLOWING CS PROFESSIONALS FOR THEIR ASSISTANCE IN THE CIS LESSON PLAN SERIES Linda Breadmont, CRCST, ACE Deborah Bunn, BS, MS, CRCST, CIS, CHL, ACE Gwendolyn Byrd, CRCST, CHL CIS, CFER, GTS Michelle Clark, CRCST, CSPDT Ava Griffin, BSN, RN, CNOR Susan Klacik, BS, CRCST, ACE, CIS, FCS Susan Ober, MSN, MBA, RN, CNOR, CRCST Christina Poston, CRCST, CIS, CHL, BA ED Donna Serra, CRCST, CHL Kelly Swails, MA, CHL, CRCST, CST Cindy Turney Smith CRCST, CBSPT WANT TO BE AN AUTHOR? IAHCSMM is seeking volunteers to write or contribute information for our CRCST Self-Study Lessons. Doing so is a great way to contribute to your own professional development, to your Association, and to your Central Service department peers. IAHCSMM will provide guidelines and help you with the lesson to ensure it will be an enjoyable process. For more information, please contact Natalie Lind (natalie@iahcsmm.org).

CRCST Self-Study Lesson Plan Quiz - Manual Cleaning Lesson No. CRCST 160 (Technical Continuing Education - TCE) Lesson expires May 2021 Sponsored by: 1. Medical device labeling is regulated by: a. The US Food and Drug Administration b. The Association for the Advancement of Medical Instrumentation c. The Department of National Labeling d. The Occupational Safety and Health Administration 2. All medical devices entering the healthcare facility must be cleaned before use, disinfection or sterilization. a. True b. False 3. Which of the following should be followed when cleaning a medical device? a. Instructions from a colleague b. Instructions for use provided by the manufacturer c. Best judgement d. Past practice 4. Why does manual cleaning need to be performed as soon as possible upon entering the decontamination area? a. To allow Central Service technicians to complete their work before the end of their shift b. To allow the loaned instrument representative to promptly pick up their loaned instruments c. To prevent the formation of biofilm d. To prevent hand fatigue and blisters 5. After cleaning, an instrument should be thoroughly rinsed to remove: a. Lint and paper b. Debris and detergent residues c. Fingerprints and biofilm d. Biofilm and lint 6. Water quality is important because: a. It reduces the amount of detergent required, thereby, reducing cost b. It helps remove biofilm c. It makes it easier to brush instruments d. It can impact the effectiveness of the detergent or enzymatic cleaner or leave a residue on instrumentation 7. The technique used to clean lumened devices is: a. Using a clean, low-linting cloth and rubbing the lumen until it is cleaned b. Using a metal brush and pushing it through the lumen c. Using the correct sized brush to ensure it contacts all surfaces of the lumen and exerts adequate friction to remove debris d. Using an available brush and brushing in a circular motion 8. Which of the following brushes is appropriate for cleaning lumens? a. A reusable brush that is changed every other day b. A brush with only a few broken bristles c. A disposable brush that is changed daily d. A brush that fits the diameter of the lumen 9. When cleaning a lumen: a. The lumen should be brushed in a way that contacts all surfaces and until the brush bristles come out clean b. The lumen should be brushed with the correct sized brush until the bristles are just beginning to fray c. The lumen should be brushed by contacting all surfaces, and at a minimum three times d. A lint-free brush should be used that makes contact with all sides of the lumen 10. Why should instruments be rinsed with cold water before cleaning? a. To prevent brush bristles from breaking b. To remove pre-soak chemicals c. To prevent rust and discoloration d. To comply with the detergent s instructions for use 11. Which of the following is not acceptable to use for drying? a. A clean, lint-free cloth b. Instrument-grade air c. A clean, low-linting cloth d. Canned air 12. When using instrument air, it is important to do which of the following to prevent damage to fragile items? a. Check the instructions for use for upper limits of forced air limit of pressure b. Ensure the correct connector is used c. Ensure the correct pressure is selected if using a suction machine to dry d. Ensure the canned air instructions for use for pressure match the lumen s instructions for use 13. Which of the following cleaning agents is appropriate for cleaning medical devices? a. A neutral-ph cleaner b. Abrasives c. A highly acidic cleaner d. Phenol 14. Which of the following is not considered treated/critical water? a. Distillation b. Deionization c. Reverse osmosis d. Tap water 15. After the application of a stain and rust remover, the instrument should be: a. Steam sterilized to cure the product b. Re-cleaned c. Dried using a clean, dry cloth d. Dried using instrument-grade air REQUEST FOR ONLINE SCORING (payment and scoring made directly online at www.iahcsmm.org) REQUEST FOR PAPER/PENCIL SCORING (please print or type information below) m I have enclosed the scoring fee of $15. (please make checks payable to Purdue University. We regret that no refunds can Name be given) m Check here if you have a change of address Mailing Address (be sure to include apartment numbers or post office boxes) m Check here if you wish to have your results emailed to you DETACH QUIZ, FOLD AND RETURN TO: Purdue University PEC Business Office Stewart Center, Room 110 128 Memorial Mall West Lafayette, Ind. 47907-2034 800.830.0269 City State Zip Code ( ) Daytime telephone IAHCSMM Membership Number Email Address If your name has changed in the last 12 months, please provide your former name. Purdue University is an equal access/equal opportunity institution.