FG-L Technical Data Sheet

Similar documents
FG-L P/N _C NSF. Certified. Technical Data Sheet. March 2017 H C K B. Item Part # Description Wiring Item #

F-L P/N _C NSF. Certified C A. Technical Data Sheet. March Item Part # Description Wiring Item # Item Part # Description Wiring Item #

FWG-L. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet P/N _D NSF. May Spanish

FIG-L P/N _F NSF. Certified January 2018 H C A L B. Technical Data Sheet

P/N _K NSF. Certified. Technical Data Sheet. March Spanish P/N Item Part # Description Wiring Item #

FWEL P/N _D NSF E D C H B A F. Certified January Technical Data Sheet. Item Part # Description Wiring Item #

FWG P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant F J G I. Technical Data Sheet. June Data sheet-excel FWG.

P/N _F NSF Certified June 2010

FIG P/N _K NSF. Certified March 2017 J A F E B I. Technical Data Sheet. Spanish P/N

FWG P/N _G. NSF Certified December Technical Data Sheet F J G I P/N _G. Item Part # Description Wiring Item #

P1NX-E P/N _G NSF. Certified. Technical Data Sheet. October 2016

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

PWWEE P/N _C NSF. Certified. Technical Data Sheet. October 2016

EXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

PWEE Technical Data Sheet

Excel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

RLNIE with INNOVATOR II

RL with INNOVATOR II No Heat Doors

P/N _G. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _G. Item Part # Description Wiring Item #

LNG P/N _H. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _H. Item Part # Description Wiring Item #

RM with INNOVATOR Doors

RLT with INNOVATOR Doors

M1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item #

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017

RMN with INNOVATOR Doors Technical Data Sheet

RLNI with P/N _J NSF. INNOVATOR Doors or. INNOVATOR III Doors. Certified. Technical Data Sheet. January 2018

RLTIM with P/N _H NSF INNOVATOR. Certified. & INNOVATOR III Doors Technical Data Sheet. January 2018

Freedom Line RFM. Certified. with INNOVATOR Doors. Medium Temperature Technical Data Sheet P/N _B NSF. Freedom Line merchandisers are top mount

Nosing Heater. Return Grill Heater

Engineering Plan Views

Freedom Line RFLNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

Freedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount

Freedom Line RFLN. Certified. with INNOVATOR Doors. or INNOVATOR III Doors Low Temperature Technical Data Sheet P/N _J NSF

LifeLine Premier RLNIE

Freedom Line RFMNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

LWU Technical Data Sheet

BEXD-8A. P/N _A NSF Certified P/N_ _A C B P E D K. Technical Data Sheet. November 2010

RLNIE P/N G. P/N _G NSF Certified. Technical Data Sheet. Warning: Terminal block NOT for case-to-case wire connection!

RL with INNOVATOR Doors

ISF and ISM. Low and Medium Temperature Remote and Self Contained Island Merchandisers. Installation & Service Manual IMPORTANT

MD Medium Temperature Self Contained Open Vertical Merchandisers

SSGB. EPH Certified to NSF-7 G B. Technical Data Sheet P/N _E. January Data sheet-excel SSGB

P/N _B September Field Installed Dual Temp Operation E P R Controlled (Evaporator Pressure Regulator)

MD Medium Temperature Self Contained Open Vertical Merchandisers

BCH Medium Temperature Merchandisers

OPTIONAL CONTROLLER. Kit P/N _A. December 2016 ANTI-CONDENSATE HEATER FOR REACH-IN GLASS DOORS. Spanish French

NFW, NCW, NFWG, NCWG, NFWE, NCWE

GSVM Medium Temperature Self Contained Open Vertical Merchandisers. Installation & Service Manual

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases

Installation & Service Manual

HGL- 1, 2 & 3 BS, TS. Bottom / Top Mount Low Temperature Remote and Self Contained Glass Door Merchandisers. Installation & Service Manual IMPORTANT

Medium Temperature Bulk Produce and Bakery Merchandisers

Low Temperature. Installation & Operation Manual IMPORTANT. Single Deck Wall & Island Merchandisers. Keep in store for future reference!

HGM-1, 2 & 3 BS, TS. Bottom / Top Mount Medium Temperature Remote and Self Contained. Installation & Service Manual. Glass Door Merchandisers

ON3.5EM-NRG ON3.5EM-NRG. Narrow Multi-Deck Merchandiser with Synerg-E End Cap (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT GENERAL NOTES:

L3MGB. THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases

Installation & Service Manual

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for

F-6 Multi-deck Frozen Food Wall Merchandisers

OPTIONAL MOTION ACTIVATED LED DIMMER CONTROL

EcoVision Door Manual

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases

Reach-in Merchandisers

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for future reference!

Installation & Service Manual

Self-Contained Medium Temperature Delicatessen, Dairy, Meat, Produce and Bakery Merchandisers

Glass Lids for Low Temperature Single Deck Wall & Island Merchandisers

Self-Contained MERCHANDISERS. February

Service Merchandisers

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL

RFLNS, RFMNS & RFLTM Freedom Line

6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA

6DMLH-NRG 6DMLH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT GENERAL NOTES

O3UM-NRG O3UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 10', 12' (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT

Self-Contained MERCHANDISERS. October

ISF and ISM Low and Medium Temperature Self Contained Island Merchandisers

Service Merchandisers

Installation & Service Manual

O5MH-NRG O5MH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT

O4ID O4ID. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) ENGINEERING REFERENCE SHEET NOTES

Ultra Low Front Rear Load Medium Temperature

O5M-NRG O5M-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

SERIES NAV S Display Merchandisers

O5DM-NRG O5DM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT Case Weight O5DM-NRG ---

Rear Roll-in Dairy Medium Temperature Free Standing or Suspended Merchandisers Installed in Walk-in Cooler Exterior Walls

EcoShine II Horizontal LEDs for Multi-Deck Merchandisers Shelf, Rail and Canopy

KRSCP Self-Contained Walk-In Unit Installation and Service Manual Addendum

ON4UM-NRG ON4UM-NRG. Narrow Multi-Deck Merchandiser 4', 6', 8', 12' (Dairy/Deli/Produce) SHIPPING WEIGHT GENERAL NOTES

OHMH-NRG OHMH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

O2.5UM-NRG O2.5UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 12' Case (Dairy/Deli/Meat/Produce/Seafood)

OIM OIM. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) REFERENCE NOTES FOR ENGINEERING DATA:

RFLN & RFMN Freedom Line

SM / SN Medium and Low Temperature Spot Merchandisers

SERIES NIM. Low Temperature Merchandisers PLEASE READ THIS MANUAL BEFORE USING THE PRODUCT

Low Temperature. Installation & Operation Manual. Keep in store for future reference. Single Deck Wall & Island Merchandisers P/N F

VNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES

Glass Doors, Hinged Bottom Mounts

EcoVision II Plus Door Upgrade for D6 Kysor Warren Multi-deck Merchandisers

Transcription:

FG-L Technical Data Sheet P/N 0523821_B A NSF Certified March 2016 G DOE 2012 Energy Efficiency Compliant H C K B E We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped. F J D L Item Part # Description Wiring Item # Fan Assemblies, and Thermostats A. 4W Standard Energy Efficient Fan Assembly (1) 0477653 Fan Motor, Evaporator (MO.4410544) 0252116 Fan Blade (FB.4780611) B. Optional Adjustable Refrigeration Thermostat (2) C. 0398557 Defrost Termination Thermostat (3) (Electric Defrost only) (CT.4440611) D. 0481370 Heater Switch (4) (Koolgas Defrost only) (CT.4440738) Heaters E. 208V Evaporator Defrost Heaters (5) 0462159 8 ft case (HE.4850603) 0444058 12 ft case (HE.4850571) F. 208V Drip Pan Defrost Heaters, Electric (6) 0462160 8 ft case (HE.4850636) 0444296 12 ft case (HE.4850572) 120V Drip Pan Defrost Heaters, Koolgas (7) 0465907 8 ft case (HE.4850622) 0465908 12 ft case (HE.4850623) Item Part # Description Wiring Item # Heaters (Continued) G. Nosing Anti-sweat Heaters (8) 0524419 8 ft case (HE.4851257) 0524421 12 ft case (HE.4851259) H. Return Grille Anti-sweat Heaters (9) 0524427 8 ft case (HE.4851251) 0524429 12 ft case (HE.4851253) J. Return Glass Anti-sweat Heaters (10) 0474778 8 ft case (GL.4987838) 0474779 12 ft case (GL.4987839) Glass Lid Parts are listed on page 5. Optional LED Fixtures and Power Supply K. 0501213 Power Supply (EP.4481861) (11) L. LED Fixture (12) NOTE: For LED lighting parts contact your Hussmann service representative at 1-800-922-1919. Please have your model and serial number available. Descriptions including size and color are at www.hussmann.com/serviceandparts. Datasheet-Excel FG-L Note: Revision B updated Refrigeration Data on page 3. 2016 HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 WWW.HUSSMANN.COM Spanish P/N 0538931

Engineering Plan Views PHYSICAL DATA Merchandiser Drip Pipe (in.) 1 1 /4 Merchandiser Liquid Line (in.) 3 /8 Merchandiser Suction Line (in.) 5 /8 02-2012 F / FG 3 in. (77 mm) Required Air Gap 41 ½ (1054) A B D 43 ⅞ (1114) 4 ¼ (108) Dimensions shown as inches and (mm). 41 ½ (1054) 4 ½ (115) 8 (203) 24 (612) Electrical Field Connection Electrical Stub Up Area 6 x 6 (152 x 152) Waste Outlet Wireway 26 ½ (673) NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD. 4 ¾ (120) Splashguard C FRONT Refrigeration Outlet Waste Outlet 10 ⅜ (263) 26 ¼ (665) 12 ⅛ (307) 30 ¼ (767) 31 ⅝ (804) 33 ½ (851) 42 (1065) 8 ft 12 ft General (A) Case Length (without ends or partitions) 96 3 /8 (2448) 144 1 /2 (3670) (Each end and insulated partition adds 2 in. (51 mm) to case line up.) Maximum O/S dimension of case back to front (includes bumper) 42 (1065) 42 (1065) Back of case to front of splashguard 33 1 /2 (851) 33 1 /2 (851) Back of case to O/S edge of front leg 30 1 /4 (767) 30 1 /4 (767) Distance between edges of external legs and center legs 41 1 /2 (1054) 41 1 /2 (1054) Distance between edges of center legs NA 43 7 /8 (1114) Distance between front legs and splashguard 3 1 /8 (82) 3 1 /8 (82) Electrical Service (Electrical Field Wiring connection point) (B) RH End of case to center of stub up area 84 1 /4 (2140) 132 3 /8 (3363) Back of case to center of stub up area 24 (612) 24 (612) Length of electrical wireway Wireway 26 1 /2 (673) 26 1 /2 (673) (C) RH End of case to LH end of wireway 90 1 /8 (2289) 138 1 /4 (3511) Waste Outlets (One each end) (D) RH End of case to the center of LH waste outlet 84 1 /4 (2140) 132 3 /8 (3363) RH End of case to the center of RH waste outlet 12 1 /8 (307) 12 1 /8 (307) Back O/S of case to center of waste outlets 31 5 /8 (804) 31 5 /8 (804) Schedule 40 PVC drip pipe 1 1 /4 (32) 1 1 /4 (32) Refrigeration Outlet Back of case to center of refrigeration outlet 26 1 /4 (665) 26 1 /4 (665) RH end of case to center of refrigeration outlet 8 (203) 8 (203) 2 of 8 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 FG-L Technical Data Sheet

Single Deck Wall Display with Glass Front and Lids DOE 2012 Energy Efficiency Compliant Hussmann refrigerated merchandisers configured for sale for use in the United States meet or surpass the requirements of the DOE 2012 energy efficiency standards. Excel FG-L FG-L 40 (1016) 24 ¾ (629) Case-to-Case Connection Refrigeration Outlet 9 (229) 3 ½ (89) Dimensions shown as inches and (mm). Open Close 15 ⅞ (404) 42 (1065) Load Limit 15 ¼ (388) Fan 3 in. (77 mm) Required Air Gap Coil 26 ¼ (665) 19 ⅞ (503) 30 ¼ (767) 31 ⅝ (804) 33 ½ (851) 33 ⅜ (848) 5 ⅞ (149) Optional PTM 35 ⅝ (905) 47 (1194) REFRIGERATION DATA Note: This data is based on store temperature and humidity that does not exceed 75 F and 55% R.H. Med FF IC Discharge Air ( F) +32 10 16 Evaporator ( F) +25 18 24 Unit Sizing ( F) +23 21 27 Btu/hr/ft * Med FF IC Parallel 130 180 210 Conventional 135 185 220 * Add 1.5 Btu/hr/ft for LED lighting. DEFROST DATA Med FF IC Frequency (hr) 24 24 24 Defrost Water (lb/ft/day) 0.25 0.29 0.3 (± 15% based on case configuration and product loading). Electric Med FF IC Temp Term ( F) 48 48 48 Failsafe (minutes) 30 50 60 Gas Duration (minutes) NA 15 18 Offtime Not Recommended Standard Defrost Thermostat Close on rise: close 48 F open 33 F CONVENTIONAL CONTROLS Low Pressure Backup Control CI/CO ** Med +28 F / +16 F FF 15 F / 27 F IC 21 F / 33 F NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability. Indoor Unit Only, Pressure Defrost Termination** Not Recommended **Use a Temperature Pressure Chart to determine PSIG conversions. Estimated Charge *** 8 ft 2.0 lb 32 oz 0.9 kg 12 ft 3.0 lb 48 oz 1.4 kg ***This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately 0.5 lb (8 oz / 0.2 kg). P/N 0523821_B HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 3 of 8

Excel FG-L Electrical Data 8 ft 12 ft Number of Fans 4W Evaporator 2 2 Amperes Watts 8 ft 12 ft 8 ft 12 ft Evaporator Fans 120V 50/60Hz Standard Energy Efficient 0.24 0.24 16 16 230V 50/60Hz Standard Energy Efficient 0.12 0.12 16 16 230V 60Hz Export 0.30 0.30 48 48 230V 50Hz Export 0.36 0.36 54 54 Anti-sweat Heaters (on fan circuit) 120V 50/60Hz Standard 0.34 0.52 41 62 230V 50/60Hz Export 0.18 0.27 41 62 Minimum Circuit Ampacity 120V 50/60Hz Standard Energy Efficient 0.78 0.96 230V 50/60Hz Standard Energy Efficient 0.50 0.59 230V 60Hz Export 0.68 0.77 230V 50Hz Export 0.74 0.83 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Return Glass Anti-sweat Heaters 120V 50/60Hz Standard 0.08 0.11 9 13 230V 50/60Hz Export 0.04 0.06 9 13 208V Electric Defrost 7.69 11.54 1600 2400 230V Export Electric Defrost 6.96 10.43 1600 2400 120V Koolgas Defrost 1.67 3.33 200 400 Standard Lighting None Optional Lighting LED 120V 50/60Hz 0.35 0.49 42 60 LED 230V 50/60Hz 0.18 0.26 42 60 4 of 8 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 FG-L Technical Data Sheet

Excel FG-L Product Data Recommended Usable Cube 1 (Cu Ft/Ft) AHRI Total Display Area 2 (Sq Ft/Ft) Shelf Area 3 (Sq Ft/Ft) 3.69 ft 3 /ft (0.34 m 3 /m) 3.02 ft 2 /ft (0.92 m 2 /m) 2.79 ft 2 /ft (0.85 m 2 /m) 1 AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft 3 /ft [m 3 /m] 2 Computed using AHRI 1200 standard methodology: Total Display Area, ft 2 [m 2 ]/Unit of Length, ft [m] 3 Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is none. ESTIMATED SHIPPING WEIGHT 4 Case Solid End 4 ft 6 ft 8 ft 12 ft (each) lb (kg) 670 (305) 1100 (506) 1120 (508) 1370 (623) 50 (23) 4 Actual weights will vary according to optional kits included. Glass Lid Replacement Parts S. 0524238 Top Glass B00147 (GL.4998375) T. 0524239 Middle Glass B00148 (GL.4998376) U. 0524240 Bottom Glass with Handle B00149 (GL.4998377) U T S P/N 0523821_B HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 5 of 8

Electric Defrost Standard 120V Neutral 120V Power 1 8 9 Brown Band Brown Band Fans Nosing Anti-Sweat Heater Return Grille Anti-Sweat Heater Refrigeration Thermostat (Optional) Defrost Termination Thermostat 2 3 Light Blue To Condensing Unit Dark Blue To Condensing Unit L1 208V Power From Defrost Contactors L2 Red 6 Drip Pan Heater 5 Red Electric Defrost Heaters Return Glass Anti-Sweat Heater Purple White 10 120V Power 120V Neutral WARNING All components must have mechanical ground, and the merchandiser must be grounded. Circled Number = Parts List Item Numbers 6 of 8 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 FG-L Technical Data Sheet

Gas Defrost Optional 120V Drip Pan Heater Koolgas Only Yellow Yellow Dark Blue 7 4 Heater Switch Dark Blue 120V Power 120V Neutral WARNING All components must have mechanical ground, and the merchandiser must be grounded. Circled Number = Parts List Item Numbers P/N 0523821_B HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 7 of 8

Excel FG-L Optional LED Lighting Wiring Diagrams Light Switch Black Input Output Power Supply 24VDC Red Blue LED Cable Tray 120 VAC from Wireway White 11 LEDs 12 F8GL LED Wiring Diagram Light Switch Black Input Output Power Supply 24VDC Red Blue LED Cable Tray 120 VAC from Wireway White 11 LEDs 12 F12GL LED Wiring Diagram 8 of 8 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 FG-L Technical Data Sheet