Cooktop Low-Profile Ventilation Hoods

Similar documents
PRO VENTILATION HOOD USE AND CARE GUIDE CLEANING, MAINTENANCE, AND MORE

C OOKTOP V ENTILATION H OODS USE &CARE INFORMATION

Warming Drawer Use & Care Guide

Imperial. Read Before Starting Installation!

Imperial. Cal. Products, Inc. Installation Instructions & Warranty Information. 425 Apollo Street Brea, CA

Multifunction Cooktop Use & Care Guide

Owner and Maintenance Guide for M Line Range Hoods with M600/M1200 Blowers

Imperial Cal Products, Inc.

2 Finding Information

NEW UNDER-CABINET HOOD INSERT DESIGN GUIDE

Use, Care, and Installation Guide

UNDER CABINET RANGE HOOD

NEW CEILING-MOUNTED HOOD DESIGN GUIDE

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

COPPER INSERT INSTALLATION INSTRUCTIONS, USE AND CARE GUIDE

UNDER CABINET RANGE HOOD. This manual is made with 100 % recycled paper.

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

XOE30 XOE36 READ AND SAVE THE INSTRUCTIONS FOR RESIDENTIAL COOKING ONLY

Barcelona Collection. Use and handling instructions Mode d emploi et d entretien Instrucciones de uso y mantenimiento

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )


User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the

Owner and Maintenance Guide Models Equipped with K250 Blower

User s Manual ISLAND SERIES TABLE OF CONTENTS RA-7630SS RA-7636SS RA-7642SS RA-7648SS. Table of Contents. Safety Information...

Bosch ventilation use and care manual DPH36652UC - DPH30652UC

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

Table of Contents. Safety Information Content Checklist Measurements Preparation Installation

User s Manual WS-68N30SS WS-68N36SS WS-68N42SS

User s Manual WS-3230SS WS-3236SS WS-3242SS WS-3248SS

IVI WARNINGS: Must be followed carefully to avoid personal injury. [VL

CLEANING & MAINTENANCE For performance, appearance, and health reasons, clean filter, fan and grease-laden surfaces. Use only a clean cloth and mild d

Use and Care & Installation Guide

READ AND SAVE THESE INSTRUCTIONS

Cooktop Chimney Ventilation Hoods

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

Pro Ventilation Hood Liners

Professional Built-In Hoods

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Euro-style Range Hood ESH5200

WS-5530SS WS-5536SS WS-5542SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

APPUZO RANGE HOOD INSTALLATION

User s Manual. NOTE: This unit does not support ducted operation. For ducted operation, please refer to model WS208L30SS or WS208L36SS

User s Manual WS-5830SS WS-5836SS WS-5842SS

READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

WARNINGS: Must be followed carefully to avoid personal injury. IMPORTANT: Must be followed carefully to avoid damage or incorrect installation.

User s Manual HI30SS HI36SS HI42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

ISLAND MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

AerFlow at ::rangehoods.com is a division of kitchen::accessories U N L I M I T E D

Use, Care, and Installation Guide

Wall Mounted Hoods. Use & Care Page 6. Installation Instructions Page 4. Warranty & Registration Page 9

Viking Use & Care Manual

Integrated Hood Liner

INSTALLATION GUIDE Fryer Module

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

Section 1 - Safety Information Section 2 - Installation: Wall Mount Hoods Section 3 - Installation: Island Mount Hoods

GE Monogram. Owner s Manual. Downdraft Vent System.

Model KER222. BEST BY BROAN P.O. Box 140 Hartford, WI ENGLISH...3 FRANÇAIS...12 ESPAÑOL

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

Integrated Hood Liner

Features and specifications are subject to change at any time without notice. Visit wolfappliance.com/specs for the most up-to-date information.

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

Use, Care, and Installation Guide

Thermedor ' A.A.,,,i,.._g,o.,.

INSTALLATION GUIDE Steamer Module

Model U102I ENGLISH...2 FRANÇAIS...15 ESPAÑOL A. BEST BY BROAN, P. O. Box 140, Hartford, WI 53027

user manual Model #: BLZ-WVH-42

user manual Model #: BLZ-HOOD

Use, Care, and Installation Guide

RANGE HOOD. Model SEH5636G. FELIX STORCH, INC. 770 Garrison Avenue Bronx, New York

Installation Instructions Preference Wall Mount Range Hood

Viking Use & Care Manual

Use & Care Manual. Professional Indoor & Outdoor Hoods. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

READ AND SAVE THESE INSTRUCTIONS Installer: Leave this manual with homeowner.

USE & CARE GUIDE Gas Cooktops

Installation Instructions. Millennia Island (Ceiling Mount) Range Hoods. Models: DHI361, DHI421, DHI482 and DHI542

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Trade-Wind 7200 Series BBQ Hood

Multi-Function Cooktop

Installation Instructions Renaissance Integrated Hood Liner

Operation Manual RANGE HOOD

Operating and Installation Instructions

Operating and Installation Instructions

INSTALLATION INSTRUCTIONS &USE & CARE GUIDE AL-T7200 Versa BBQ Hood Series

READ AND SAVE THESE INSTRUCTIONS

BX600. CLASSIC ColleCtion. Specifications. Model Colour Venting Size. Air Flow Volume: Electrical Consumption:

Use and Care Manual Island/Wall Hoods. Millennia. Table of Contents

Use & Care. Professional Indoor & Outdoor Hoods

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

Viking Use & Care Manual

UseandCare & Installation Guide

Use, Care, and Installation Guide READ AND SAVE THESE INSTRUCTIONS

CHIMNEY RANGE HOODS MODELS VJ603302SS & VJ604302SS

Contents. Dishwashers Cove Warranty... 5

e Bath Fan with Light User s Guide

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Trade-Wind Professional Series Liners

Installation Instructions

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Trade-Wind P7200 Series BBQ Hood

MH70230AS MH70236AS MH70248AS

Use and Care Manual Downdraft Raised Vent

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

Transcription:

USE & CARE GUIDE Cooktop Low-Profile Ventilation Hoods

Contents Wolf Cooktop Low-Profile Ventilation Hoods 3 Safety Instructions 4 Cooktop Low-Profile Hood Features 6 Cooktop Low-Profile Hood Operation 8 Cooktop Low-Profile Hood Care 9 Troubleshooting Guide 13 Service Information 14 Wolf Warranty 15 Important Note To ensure the safe and efficient use of Wolf equipment, please take note of the following types of highlighted information throughout this guide: IMPORTANT NOTE highlights information that is especially important. CAUTION signals a situation where minor injury or product damage may occur if instructions are not followed. WARNING states a hazard that may cause serious injury or death if precautions are not followed. Features and specifications are subject to change at any time without notice. Visit our website, wolfappliance.com for the most up-to-date information. IMPORTANT NOTE: Throughout this guide, dimensions in parentheses are millimeters unless otherwise specified.

Wolf Cooktop Low-Profile Ventilation Hoods 3 wolfappliance.com Thank You Your purchase of a Wolf cooktop low-profile hood attests to the importance you place upon the quality and performance of your cooking equipment. We understand this importance and have designed and built your ventilation hood with quality materials and workmanship to give you years of dependable service. Before you begin using your ventilation hood, please take some time to read this use & care guide. It will be to your benefit to familiarize yourself with the safety practices, features, operation and care recommendations for your ventilation hood. If service should become necessary, you will need the model and serial numbers of the cooktop low-profile hood. Both numbers are listed on the product rating plate, located on the underside of the hood, above the grease filter. The filter must be removed to access the rating plate. Refer to the illustration below. IMPORTANT NOTE: Wolf cooktop low-profile hoods are recommended for use with Wolf induction, electric and gas cooktops and integrated modules. For ranges and rangetops, a Wolf pro ventilation hood is recommended. Your Wolf ventilation hood is protected by a warranty that is one of the finest in the industry. Take a moment to read the warranty statement at the end of this guide and refer to it should service become necessary. RATING PLATE Location of rating plate.

Safety Instructions 4 IMPORTANT INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS Read this use & care guide carefully before using your new ventilation hood to reduce the risk of fire, electric shock or injury to persons. Ensure proper installation and servicing. This appliance must be properly installed and grounded by a qualified technician. Warranty service must be performed by Wolf factory certified service. TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. b) Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. b) Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) and the local code authorities. c) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. d) Ducted fans must always be vented to the outdoors. TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. To reduce risk of fire and to properly exhaust air, be sure to duct air outside Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages.

Safety Instructions 5 wolfappliance.com IMPORTANT INSTRUCTIONS For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device. GENERAL SAFETY REQUIREMENTS For best capture of cooking impurities, the bottom of the hood should be a minimum of 30" (762) and a maximum of 36" (914) above the countertop. Use only with ventilation hood cord connection kits that have been investigated and found acceptable for use with this model hood. Do not repair or replace any part of this appliance unless specifically recommended in this guide. All other service should be performed by a qualified technician. This ventilation hood is equipped with a thermostat which may start the blower automatically. To reduce the risk of injury and to prevent power from being switched on accidentally, switch power off at service panel and lock or tag service panel. Avoid using food products that produce flames under the ventilation hood. This product may have sharp edges. Be careful to avoid cuts and abrasions during installation and cleaning. TO REDUCE RISK OF RANGE TOP GREASE FIRE: a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. b) Always turn hood ON when cooking at high heat or when flambéing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé). c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter. d) Use proper pan size. Always use cookware appropriate for the size of the surface element. TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*: a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. b) NEVER PICK UP A FLAMING PAN You may be burned. c) DO NOT USE WATER, including wet dishcloths or towels a violent steam explosion will result. d) Use an extinguisher ONLY if: 1) You know you have a Class ABC extinguisher, and you already know how to operate it. 2) The fire is small and contained in the area where it started. 3) The fire department is being called. 4) You can fight the fire with your back to an exit. *Based on Kitchen Fire Safety Tips published by NFPA.

Cooktop Low-Profile Hood Features 6 Low-Profile Wall Hood Features Heavy-duty, stainless steel seamless construction. 500 CFM internal blower included with (I) models. In-line or remote blower options for models CTEWH36 and CTEWH45. Telescopic chimney flue fits 8' (2.4 m) to 9' (2.7 m) ceilings. Dishwasher-safe aluminum mesh filter(s) with stainless steel filter cover(s). Transition with backdraft damper. UL listed to US and Canadian safety standards. Two and five year residential warranty. Black glass control panel with digital indicator and four-speed blower control. Heat sentry to automatically turn unit on when heat is sensed and to adjust blower speed. Halogen lighting with three settings. Delay-off feature to automatically turn unit off. Filter clean indicator. COOKTOP LOW-PROFILE WALL HOOD Model CTEWH36 shown. Telescopic chimney flue Heavy-duty stainless steel construction Contemporary low-profile design Black glass control panel Halogen lighting Aluminum mesh grease filter(s) Digital indicator

Cooktop Low-Profile Hood Features 7 wolfappliance.com Low-Profile Island Hood Features Heavy-duty, stainless steel seamless construction. 500 CFM internal blower included. Telescopic chimney flue fits 8' (2.4 m) to 9' (2.7 m) ceilings. Black glass control panel with digital indicator and four-speed blower control. Heat sentry to automatically turn unit on when heat is sensed and to adjust blower speed. Accessories Optional accessories are avail able through your authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com. In-line and remote blowers for wall hood models CTEWH36 and CTEWH45. 30" (762) high stainless steel wall shield for wall hoods. Recirculating kit and filter for non-ducted applications (internal blower models). Halogen lighting with three settings. Delay-off feature to automatically turn unit off. Filter clean indicator. Dishwasher-safe aluminum mesh filters with stainless steel filter covers. Transition with backdraft damper. UL listed to US and Canadian safety standards. Two and five year residential warranty. COOKTOP LOW-PROFILE ISLAND HOOD Model CTEIH42I shown. Telescopic chimney flue Heavy-duty stainless steel construction Contemporary low-profile design Black glass control panel Halogen lighting Aluminum mesh grease filters Digital indicator

Cooktop Low-Profile Hood Operation 8 Hood Controls The Wolf cooktop low-profile hood is operated using the touch control pads on the front face of the hood. Refer to the illustration below. L) LIGHTS. Touch the pad once to turn the lights ON, touch a second time to turn the lights ON to a brighter level and touch a third time to turn the lights OFF. 1) A touch activates the blower motor at the first speed (icon is illuminated). Press the pad for about two seconds to turn the blower OFF. 2) Activates the blower at the second speed. 3) Activates the blower at the third speed. 4) Activates the blower at the fourth speed. A) Touch the A pad to set a TIMER which keeps the blower operating at the current speed for 10 minutes. Heat Sentry Feature The heat sentry feature turns the ventilation hood on when heat is sensed and adjusts the blower speed automatically. The heat sentry feature is activated when the exhaust from the hood reaches a threshold temperature and deactivated when the exhaust temperature decreases. If the blower is off, it automatically turns the blower on to HIGH speed. If the blower is on at a lower speed setting, it will automatically adjust to HIGH speed. When the temperature level drops, it adjusts the blower back to the setting on the blower control. IMPORTANT NOTE: The heat sentry thermostat can start the blower even if the hood is turned off. When this occurs, the blower cannot be turned off by the hood controls. If you must turn off the blower, do it from the main electrical panel. F) FILTER. After 30 hours of operation, the F icon is illuminated to indicate that the grease filter(s) must be cleaned. After 120 hours, the icon flashes to indicate that the grease filter(s) must be cleaned and the charcoal filter replaced. To reset the hour counter, touch F while the icon is illuminated or flashing. Hood controls.

Cooktop Low-Profile Hood Care 9 wolfappliance.com Halogen Lighting Wolf cooktop low-profile hoods have halogen lighting with three settings. Halogen bulbs are included with the hood. For replacement, cooktop low-profile hoods require type T4, 12V, 20W halogen bulbs, which are available at hardware stores or through your authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com. Use caution when handling light bulbs. Halogen bulbs get hot instantly and adjacent parts may retain heat. LIGHT BULB REPLACEMENT IMPORTANT NOTE: Use a paper towel when handling the replacement halogen bulb to keep oil on fingers from touching the bulb. Failure to do this will shorten the life of the bulb. 1) Turn off the blower and lights and allow the halogen bulb to cool before replacing. 2) Open the light cover by pressing in on the slots as shown in the illustration below. Remove the old halogen bulb by pulling it straight out of the socket. 3) Using a paper towel to handle the new halogen bulb, insert the bulb into the socket. Place the light cover back onto the light assembly. LIGHT COVER HALOGEN LIGHTING Light bulb replacement.

Cooktop Low-Profile Hood Care 10 Grease Filters The aluminum mesh grease filter(s) should be cleaned approximately every month, depending on use. The F touch pad of the hood controls will illuminate to indicate when the filter(s) should be cleaned. This indicator light comes on after approximately 30 hours of operation. To reset the hour counter, touch the F touch pad while the icon is illuminated. You may need to clean the filter(s) more often if your cooking style generates large amounts of grease, like frying foods or wok cooking. Refer to care recommendations on page 12. GREASE FILTER REMOVAL To access the grease filter(s), gently pull down on the front edge of the bottom panel and allow it to rotate downward as shown in the illustration below. Push the handle for the filter outward and pull the filter downward to remove. Reinstall using the reverse procedure. IMPORTANT NOTE: Do not operate the ventilation hood without the grease filter(s). This may cause damage to the blower or other internal components of the hood. GREASE FILTER Grease filter removal.

Cooktop Low-Profile Hood Care 11 wolfappliance.com Charcoal Filter RECIRCULATING APPLICATION If the ventilation hood is used in a recirculating or non-ducted application, the charcoal filter must be replaced at regular intervals. The F touch pad of the hood controls will flash to indicate when the charcoal filter needs to be replaced. This indicator light flashes after approximately 120 hours of operation. To reset the hour counter, press the F touch pad while the icon is flashing. CHARCOAL FILTER REMOVAL First remove the grease filter(s) as described on the previous page. Then remove the charcoal filter as shown in illustration below. Push the catch towards the inside and turn the charcoal filter so that the two filter clips slip out of their seats. Install the new charcoal filter using the reverse procedure. IMPORTANT NOTE: Resetting the 120 hour counter for the charcoal filter will not affect the 30 hour counter for the grease filter. Replacement charcoal filters are available through your authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com. CHARCOAL FILTER GREASE FILTER Charcoal filter removal.

Cooktop Low-Profile Hood Care 12 Care Recommendations STAINLESS STEEL Most surfaces of your cooktop low-profile hood are stainless steel. Although resistant to most stains, it is not totally impervious to damage. Salt and some cooking liquids may pit and stain the surface. Remove these spatters immediately. IMPORTANT NOTE: Do not use abrasive cleaners; they will permanently scratch stainless steel surfaces. Use a spray degreaser to remove fingerprints and greasy spatters. Spray on a cloth and wipe the surface. Buff dry immediately to avoid streaking. For hard water stains, use white vinegar and water. For general cleaning, use a soft, nonabrasive stainless steel cleaner like Signature polish and apply with a soft lint-free cloth. To bring out the natural luster, lightly wipe the surface with a water-dampened microfiber cloth followed by a dry polishing chamois. All work should follow the grain direction of the finish. Better results are obtained by keeping the cloth in continuous contact with the stainless steel. GLASS CONTROL PANEL Use a spray degreaser to remove fingerprints and greasy spatters. Spray on a cloth and wipe the surface. Use a clean cloth or sponge and wipe the surface with warm water and a mild detergent. Rinse and dry immediately. GREASE FILTERS The aluminum mesh filter(s) and stainless steel cover(s) are dishwasher safe and are designed to fit most dishwashers. Wolf recommends wiping filters and filter covers to remove any excess grease before placing in the dishwasher. Clean the filters and filter covers in the dishwasher or hand wash using a mild detergent. Refer to filter removal on page 10. Signature polish is available from Signature Limited Laboratory, P. O. Box 13436, Dayton, Ohio 45413, or call 877-376-5474.

Troubleshooting Guide 13 wolfappliance.com Troubleshooting If your Wolf ventilation hood is not operating properly, use the following troubleshooting guide before calling your Wolf authorized service center. This guide will save you time and trouble and may help you avoid the expense of a service call. DISCONNECTING SWITCH IMPORTANT NOTE: To reduce the risk of injury, disconnect the power supply before servicing. This hood is equipped with an integral disconnecting switch located inside the blower housing. Refer to the illustration below. Ventilation hood does not operate. Check the household fuse or circuit breaker to see if it has been blown or tripped. A power outage may also have caused a disruption in service. No electricity is being supplied to the ventilation hood. Have an electrician verify that the hood is connected to a proper electrical circuit. Blower runs but lights do not operate. DISCONNECTING SWITCH Check the light bulbs to see if they have burned out. Location of disconnecting switch.

Service Information 14 Service Information When requesting information, literature, replacement parts or service, always refer to the model and serial numbers of your ventilation hood. This information is found on the product rating plate located on the underside of the hood, above the grease filter. The filter must be removed to access the rating plate. Refer to the illustration on page 3. Record the rating plate information below for future reference. Model Number: Serial Number: Installation Date: Wolf Factory Certified Service: Phone: Authorized Wolf Dealer: BEFORE CALLING FOR SERVICE Before calling Wolf factory certified service, refer to the troubleshooting guide on page 13. PRODUCT REGISTRATION Register your new Wolf product today so that we may ensure your satisfaction. You may register by one of the following options: 1) Mail in the completed Wolf product registration card. 2) Register online at wolfappliance.com. 3) Register by phone by calling Wolf customer care at 800-222-7820. The model and serial numbers of your unit are printed on the enclosed Wolf product registration card. If you provide us with your e-mail address, we will send you exciting new product updates and recipes as they become available, along with information on special events. Phone: The information and images in this guide are the copyright property of Wolf Appliance, Inc. Neither this guide nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Wolf Appliance, Inc. Wolf Appliance, Inc. all rights reserved. Wolf, Wolf & Design, Wolf Gourmet, W & Design and the color red as applied to knobs are registered trademarks and service marks of Wolf Appliance, Inc. Sub-Zero, Sub-Zero & Design, Dual Refrigeration, Constant Care and The Living Kitchen are registered trademarks and service marks of Sub-Zero, Inc. (collectively, the Company Marks. ) All other trademarks or registered trademarks are property of their respective owners in the United States and other countries.

Wolf Appliance Products Limited Warranty FOR RESIDENTIAL USE ONLY FULL TWO YEAR WARRANTY* For two years from the date of original installation, your Wolf Appliance product warranty covers all parts and labor to repair or replace, under normal residential use, any part of the product that proves to be defective in materials or workmanship. All service provided by Wolf Appliance under the above warranty must be performed by Wolf factory certified service, unless otherwise specified by Wolf Appliance, Inc. Service will be provided during normal business hours. LIMITED FIVE YEAR WARRANTY For five years from the date of original installation, Wolf Appliance will repair or replace the following parts that prove to be defective in materials or workmanship: gas burners (excluding appearance), electric heating elements, blower motors (ventilation hoods), electronic control boards, magnetron tubes and induction generators. The part(s) will be repaired or replaced, free of charge, with the owner paying for all other costs including labor. All service provided by Wolf Appliance under the above warranty must be performed by Wolf factory certified service, unless otherwise specified by Wolf Appliance, Inc. Service will be provided during normal business hours. TERMS APPLICABLE TO EACH WARRANTY The warranty applies only to products installed for normal residential use. The warranty applies only to products installed in any one of the fifty states of the United States, the District of Columbia or the ten provinces of Canada. This warranty does not cover any parts or labor to correct any defect caused by negligence, accident or improper use, maintenance, installation, service or repair. THE REMEDIES DESCRIBED ABOVE FOR EACH WARRANTY ARE THE ONLY ONES THAT WOLF APPLIANCE, INC. WILL PROVIDE, EITHER UNDER THIS WARRANTY OR UNDER ANY WARRANTY ARISING BY OPERATION OF LAW. WOLF APPLIANCE, INC. WILL NOT BE RESPONSIBLE FOR ANY CONSEQUENTIAL OR INCIDEN- TAL DAMAGES ARISING FROM THE BREACH OF THIS WARRANTY OR ANY OTHER WARRANTY, WHETHER EXPRESS, IMPLIED OR STATUTORY. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other legal rights that vary from state to state. To receive parts and/or service and the name of Wolf factory certified service nearest you, contact Wolf Appliance, Inc., P.O. Box 44848, Madison, WI 53744; check the contact & support section of our website, wolfappliance.com or call 800-222-7820. *Stainless steel doors, panels, handles, product frames and interior surfaces are covered by a limited 60-day parts and labor warranty for cosmetic defects. *Replacement filters for ventilation hood recirculating kits are not covered by the product warranty.

WOLF APPLIANCE, INC. P. O. BOX 44848 MADISON, WI 53744 WOLFAPPLIANCE.COM 800.222.7820 824898 REV-A 12/2013