IT Cooling Solutions Telecom Line

Similar documents
IT Cooling Solutions. MiniSpace and MiniSpace EC. Reliability for small and medium-sized IT rooms

An efficient way to optimum air quality

An efficient way to optimum air quality

IT Cooling Solutions. CyberRow. Intelligent air flow control for more efficiency in rack cooling

IT Cooling Solutions. CyberRow. Intelligent air flow control for more efficiency in rack cooling

STULZ the natural choice. Compact DX Close Control Air Conditioning for High-end Applications

STULZ Explorer WSA. Air-cooled chillers for a cooling capacity of 370 to 1260 kw

Integrated protection for IT rooms and computer centres STULZ the air conditioning specialist for the complete EDP room

STULZ the natural choice. CyberAir. the new world of close control air conditioning

CyberOne EC. Chilled Water Systems kw Vertical Floor Mounted, 60 Hz Data. Engineering Manual

Flexible & Innovative. Cooling Solutions

Intelligent AIR HANDLING UNITS

AIRSYS-P-SC-MOBILECOOL-INDOOR-E1507V01.2 MOBILECOOL-INDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.4~13.

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

Liebert HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

COMPRESSOR SYSTEMS MADE IN GERMANY G-DRIVE & V-DRIVE SCREW COMPRESSORS

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

Industrial cooling systems LT

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6

AIRSYS-P-SC-MOBILECOOL-OUTDOOR-E1509V01.5 MOBILECOOL-OUTDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.5kW-13.

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

ThermoControl 0 C - 10 C - 20 C - 30 C

Liebert HIROSS for Telecom

Munters DesiCool removes excess heat in server room

The product segments Heating, ventilation, air conditioning. Control Products & Systems OEM.

Precision Cooling. DataMate3000 Series Precision Cooling Systems for Small Equipment Room IT Application

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

Detection, Protection, Innovation

gforce Units Data Aire and Data Temp Series

IT Cooling Solutions. CyberRow. Intelligent air flow control for more efficiency in rack cooling

COOLflow 4E PRODUCT RANGE

Modular Air-cooled Chillers

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Cleanroom systems. Supply air ceiling and recirculated air ceiling OP. for operating rooms with low-turbulence displacement flow

Beckhoff short profile

AHU Plus. DX Air Handling Units

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

OPERATING RELIABILITY AND CONTINUITY. HIGH SENSIBLE COOLING CAPACITY No latent cooling required.

Be sustainable while protecting your business

Güntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

PRODUCT INFORMATION HISIC450 OVERHEIGHT DETECTORS RELIABLE OVERHEIGHT DETECTION OF VEHICLES. Traffic sensors

The refrigerant circuit was studied in detail. Each step is verified, ensuring that each unit is perfectly leak-tight.

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

Reliability and extended operation

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

IT Cooling Solutions. CyberAir 3 Precision Cooling Solutions. Maximum efficiency in data centre air conditioning

Pilz for a safe crane system

Chilled Water Precision Air Conditioner for Critical Application

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

8-101kW. AlphaCool close control range ADDITIONAL CAPACITIES. NOW AVAILABLE Plus EC fan option kW. Typical applications

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

MEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil

IT COOLING CLOSE CONTROL AIR CONDITIONERS PRECISION AIR CONDITIONERS WITH INVERTER TECHNOLOGY FOR STABLE ROOM CONDITIONS

Medical Refrigerators

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

AVAILABILITY EASE OF INSTALLATION SERVICE. SpectraCool Slim Fit Air Conditioner. Easy to Specify and Ready to Use

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

Cultivator & Hybrid Cultivator

T5000 T5000 LCD Digital Fan Coil Thermostat--More Models

Ducted inverter reverse cycle air conditioning

Dehumidifying Dryers DP DP 615 Series

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

Octalarm-T: the latest in future-proof industrial alarm diallers

BURAN BURAN. Refrigeration Compressed Air Dryers for volume flows from 20 to 850 m³/h

PROCESS AUTOMATION TIME TO RELAX ADVANCED DIAGNOSTICS EXPERT SYSTEM AT WORK

next NEXT EVO CW kw UP FLOW DOWN FLOW CHILLED WATER E C CLOSE CONTROL AIR CONDITIONERS FOR CHILLED WATER FEEDING,

DATASHEET CoolTeg Plus CW CoolTeg Plus DX CoolTeg Plus XC

PRODUCT INFORMATION. SureSense THE SURE WAY TO DETECT ANY OBJECT. Photoelectric Sensors

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Technical information Master

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

2013 Product Range Precision Air Conditioners (CRAC)

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Integrated VarIable refrigerant flow ahu/pau (r410a)

Outdoor Condensing Unit - ZX Range. High Efficiency In Compact Design

STT 3000 Series STT250 /150 Surge Protection Device Specifications

McQuay HydroflexTM Residential and Light Commercial Chilled Water System

Rotary Screw Compressors SX Series With the world-renowned SIGMA PROFILE Free air delivery from 0.26 to 0.81 m³/min, Pressure 5.

DEFECTOVISION IR. Non-Destructive Testing of Steel Billets and Tubes

Global Series Screw Air Compressors Life source of industries

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Key benefits. Why Condair CP3?

Do More With Less

PROCESS AUTOMATION PROGRAMMING TREE 6000 SERIES PURGE/PRESSURIZATION SYSTEM

VACUUM FOR HIGHER QUALITY. In plastic injection molding

Quality Design Innovation Functionality

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort

The integral solution for. Air Handling Units. Technology & Evolution

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Transcription:

IT Cooling Solutions Telecom Line Air conditioning for base stations of cell phone networks

Reliable air conditioning with the STULZ Telecom Line. For more than 40 years, sensitive information and communication technology has been cooled by air-conditioning systems made by STULZ everywhere in the world. Our formula for success is both simple and sophisticated: we are engineers with a vision and business people who know a lot about technology. Containers, shelters and base stations for telecommunications pose special challenges for air conditioning technology. With the Telecom Line, STULZ offers a range of professional air conditioning solutions for the telecommunications infrastructure, which reliably cool the receiving and transmitting stations of cell phone networks in any weather conditions.

Air conditioning for base stations of cell phone networks CONTENTS Control technology Page 6 Telecom Line products Page 12 STULZ worldwide Page 24 STULZ Telecom Line Overview...4 5 Variable solutions for more energy efficiency... 5 STULZ control technology for Telecom Line products...6 9 STULZ Telecom Line products WallAir Evolution Precision air conditioning unit for outdoor installation...12 13 TelAir 2 Precision air conditioning unit for indoor installation...14 15 SplitAir 3 Precision air conditioning unit for flexible installation...16 18 FreeAir Free Cooling retrofit solution for indoor and outdoor installation...18 19 Technical data of all Telecom Line products...20 21 STULZ worldwide... 24 3

STULZ Telecom Line products and systems Overview STULZ supplies four different systems capable of utilizing Free Cooling, tailor-made to your individual requirements. With WallAir, Tel-Air, Split-Air and FreeAir systems, you can cut the energy costs of your air conditioning by up to 96 %. Compact, sturdy and economical to run, these systems work around the clock for many years to ensure the availability of cell phone technology. The Telecom Line units are plug and play and therefore immediately ready to connect and use. Thanks to the variety of options available, they can be individually configured to customers' specific requirements and needs. STULZ Telecom Line Free Cooling Mixed mode DX mode Upflow Displacement Downflow Plug and play Indoor installation Tel-Air FreeAir FCL-IN Outdoor installation WallAir Split-Air FreeAir FCL Variable air conduction and Free Cooling solutions for more energy efficiency Displacement Cold supply air flows in close to the ground at low speed. Due to the low speed at which the air is flowing, a "pool" of cold air forms on the floor. This cold air is drawn in by fans integrated in the server rack to a varying extent depending on the heat load, and then expelled upwards as heated air. Because the cold and hot air are prevented from mixing, the displacement unit can draw the circulating air in at 30 C, instead of 25 C as was previously the case. This higher temperature level increases the number of operating hours with Free Cooling. 4

STULZ Telecom Line products and systems Overview Upflow Upflow units draw the return air out of the room from the front of the air conditioning unit, and expel the cooled supply air upwards. In server rooms, upflow units can be connected to a duct, so that the cold supply air is conveyed right up to the consumer without any warm room air mixing with it. Downflow Downflow units draw the return air out of the room from above and expel cooled supply air down into the raised floor. Through the raised floor, the supply air reaches exactly the right spot in the room that requires cooling. Telecom Line Free Cooling solutions In many base stations, comfort air conditioning units without Free Cooling mode are still used today for air conditioning, with high energy consumption as the consequence. STULZ Telecom Line units exploit the potential of Free Cooling and slash operating costs. Free Cooling At low outside temperatures, cooling is direct with outside air. The outside air is conveyed into the container when the air damper is open. Energy-intensive compressor cooling is not needed when outside temperatures are low. Free Cooling achieves potential savings of up to 96 %. Mixed mode If the outside temperature exceeds a given threshold, Free Cooling alone is no longer sufficient. Then, in Mixed mode, the runtimes of the compressor are kept to a minimum by the simultaneous use of Free Cooling and compressor cooling. In this way, depending on the local temperature profile, annual energy costs can be cut by a further 10 %. The partial load mode of the air conditioning unit delivers further potential savings. 5

STULZ control technology For Telecom Line products To be able to cool IT systems efficiently and reliably, air conditioning units and their control systems must work in perfect harmony. That is why here at STULZ, we design both air conditioning units and controllers under one roof. And on this basis, we can ensure maximum reliability and efficiency for STULZ hardware and software. C2020 microprocessor for WallAir, TelAir 2 and SplitAir 3 The C2020 consists of a controller and an optional operator terminal. The controller controls all functions of Telecom Line products. The operator terminal, consisting of a keypad and LCD, displays the most important operating states and alarms. Sequencing The C2020 enables up to ten units to be configured in one air conditioning system. If an individual unit drops out or the heat load rises, the standby unit is switched in for additional support The operating times of all connected air conditioning units are compared to make sure each one is used to an equal extent Night mode Controlling the various operating modes Free Cooling function dependent on temperature and enthalpy Mixed mode management Compressor operation Backup ventilation upon failure of the main power supply Heating Humidification and dehumidification Condenser and evaporator fan speed is limited in a timecontrolled manner, to ensure quiet operation Energy-saving mode The (adjustable) fan speed is automatically reduced at times when neither heating nor cooling is required 6

C2020 microprocessor For WallAir, TelAir 2 and SplitAir 3 C2020 and C102 operator terminal Multi-step configuration menu via operator terminal Operator Service (password protected) Multilingual display The operator terminal offers a choice of seven languages for displaying general menus, alarms and setpoints Monitoring and alarm relaying Via BMS systems (Modbus on board, further protocols via WIB 1000) Simple configuration and software updates Central configuration of units via laptop Hardware key for uploading and downloading software without a laptop and/or for copying the configuration onto other units High pressure alarm management In order to avoid unnecessary service callouts, high pressure alarms are initially reset three times automatically. Then, after the fourth error message, the alarm must be manually deleted after four hours Nine voltage free contacts are available: Alarms can be assigned a high or low priority Via GSM modem (CompTrol SMS) 7

C102 microprocessor For FreeAir The FreeAir units are monitored and controlled by the C102 microprocessor. Comfort air conditioning units can be integrated in the existing air conditioning system and also actuated by the C102 controller. Whenever the outside temperature allows, Free Cooling mode is activated and the comfort air conditioning units are switched off. The C102 microprocessor guarantees maximum versatility The integrated relays enable the C102 to control and monitor up to two connected comfort air conditioning units Alternatively, one air conditioning unit and one external heater can be controlled Directly measures the energy consumption of the FreeAir units and records the operating hours of the comfort air conditioning units Backup ventilation upon failure of the main power supply or a fault in the comfort air conditioning units Monitors DC voltage and disables units if the battery voltage is below the permitted threshold Configurable filter alarm triggered by differential pressure, or via an adjustable fan operating time Service mode: Forced switch-off of a unit is possible, to enable service work to be performed at a base station. The air conditioning unit starts automatically after an adjustable time interval Semi-automated commissioning test for checking all components Monitoring: ModBus on board, further protocols via WIB 1000 48 VDC power supply enables it to be used as emergency backup ventilation 8

WIB 1000 interface For Telecom Line products WIB 1000: The all-in-one interface to your air conditioning technology WIB 1000 is user-friendly and offers easy data exchange, monitoring and diverse options for use around the world. Functions and monitoring Ongoing retrieval of data from the controller Ethernet interface Easy connection to existing building management systems Network solutions for limitless communication Compatible with all common BMS systems Communication via SNMP and HTTP IP protocols User friendly Simultaneous HTTP and SNMP Easy, fast configuration via laptop C2020 C2020 C2020 C102 Gateways for STULZ controller systems ALARM Remote monitoring and control Alarm/central control technology HTTP/ SNMP Display/ visualization Operation Remote maintenance Data protocol Modbus 1) Saia bus 1) 1) 2) SNMP 1) 2) HTTP GSM CompTrol 1) 3) SMS 1) Serial RS485 interface card required. 2) Compatible gateways available as an option. 3) Via central control technology contacts. Customer 9

10

AIR CONDITIONING FOR BASE STATIONS OF CELL PHONE NETWORKS STULZ Telecom Line products WallAir TelAir 2 SplitAir 3 FreeAir Air conditioning units from STULZ ensure the availability and stability of cell phone networks all over the world. 11

STULZ WallAir Evolution Precision air conditioning unit for outdoor installation In telecommunication containers, space is at a premium. WallAir Evolution units are installed outside the container, making the best possible use of the container space. These compact, weather-resistant air conditioning units work using the displacement method, and are immediately ready for connection and operation. The units boast Free Cooling and Mixed modes, and therefore achieve savings of up to 84 % on operating costs. In the WDE version, WallAir Evolution units are available with a constant-speed compressor, while the WDI version offers a variable-speed EC compressor. Free Cooling Mixed mode Displacement Upflow Downflow Outdoor installation Plug and play New version: WallAir Evolution with EC compressor (WDI) Up to 84 % savings on operating costs thanks to Mixed and Free Cooling mode 1.400 Annual energy consumption (kwh) 1.200 1.000 800 600 100% 400 200 16% 0 Outside temperature ( C) -16 0 14 Energy consumption with the use of Free Cooling and Mixed modes Energy consumption without Free Cooling using the example of a WDE A0, based on the temperature profile of the city of Hamburg 32 12

STULZ WallAir Evolution Precision air conditioning unit for outdoor installation Features of the WallAir Evolution Reduced operating costs thanks to: Free Cooling and Mixed modes Displacement principle Condensation pressure control Factory tested, filled with refrigerant and ready for operation from the very first day Filter monitor and airflow alarm Inside and outside temperature sensors G4 zig-zag air filter Heat exchanger with microchannel technology C2020 microprocessor Outside air conditions 20/+50 C winter/summer Automatic restart after power failure Refrigerant R407C Options High temperature operation up to 55 C with R134a Winter kit down to 40 C Compressor soft start for low starting currents Electrical wiring, with connector for plug and play External operator terminal for C2020 Electric heater Humidity sensor WIB 1000 interface Advantages thanks to variable-speed EC compressor (WDI version) Maximum energy efficiency in partial load mode Constant supply air temperature Refrigerant R410A Integrated compressor soft start Long service life thanks to continuous operation without compressor on/off cycles WallAir Displacement air distribution Free Cooling Mixed mode Compressor operation Installation of the WallAir Displacement 13

STULZ TelAir 2 Precision air conditioning unit for indoor installation TelAir 2 units are designed for installation in telecommunication containers and equipment rooms. As they are installed indoors, noise is kept to a minimum and the units are protected against environmental influences and vandalism. The air conditioning units are plug and play and immediately ready for connection and use. Thanks to their quiet running, they can be used without problem in residential areas. All TelAir 2 units also feature a Mixed mode, which effectively combines Free Cooling with compressor operation, dramatically reducing operating costs. The individual models of the TelAir 2 series are available in upflow and downflow versions, and in the especially energy efficient displacement version. TelAir 2 Upflow (TLU) TelAir 2 Downflow (TLD) Free Cooling Mixed mode Displacement Upflow Downflow Indoor installation Plug and play TelAir 2 Displacement (TLF): The unit pictured here is equipped with the optional blow-out diffuser. Installation of the TelAir 2 Displacement Up to 83 % savings on operating costs thanks to Mixed and Free Cooling modes 1.400 Annual energy consumption (kwh) 1.200 1.000 800 600 100% 400 200 17% 0 Outside temperature ( C) -16 0 14 Energy consumption with the use of Free Cooling and Mixed modes Energy consumption without Free Cooling using the example of a TLF 90, based on the temperature profile of the city of Hamburg 32 14

STULZ TelAir 2 Precision air conditioning unit for indoor installation Features of the TelAir 2 Reduced operating costs thanks to: Free Cooling and Mixed modes Condensation pressure control Factory tested, filled with refrigerant and ready for operation from the very first day Automatic restart after power failure Filter monitor and airflow alarm Inside and outside temperature sensors G4 zig-zag air filter Outside air conditions 20/+50 C winter/summer C2020 microprocessor Refrigerant R407C Options High temperature operation up to 55 C with R134a Winter kit down to 40 C Compressor soft start for low starting currents Electrical wiring, with connector for plug and play Operator terminal for C2020 Electric heater Heat exchanger with anti-corrosive finish WIB 1000 interface Humidity sensor Air distribution of the TelAir 2 Upflow (TLU) Air distribution of the TelAir 2 Downflow (TLD) Air distribution of the TelAir 2 Displacement (TLF) Free Cooling Compressor operation Free Cooling Compressor operation Free Cooling Compressor operation 15

STULZ SplitAir 3 Precision air conditioning unit for flexible installation SplitAir 3 is the space and energy-saving version for the reliable cooling of telecommunication containers. The unit consists of an evaporator and a condenser unit, and is a plug and play design allowing immediate connection and use. The SplitAir 3 features Free Cooling and Mixed modes, and therefore achieves savings of up to 83 % on operating costs. Because the indoor unit can be installed either on the ceiling or the wall, the SplitAir 3 is also suitable for use when space is at a premium. Thanks to the low noise level of the outdoor unit, the SplitAir 3 can also be used without problem in residential areas. SplitAir 3 units are available as an SAL version with constant-speed compressor. To further increase energy efficiency, these units are now also available in the SIL version, with variable-speed EC compressor. Indoor unit Evaporator unit with Free Cooling module Free Cooling Mixed mode Displacement Upflow Downflow Plug and play New version: SplitAir 3 with EC compressor (SIL) Outdoor unit Compressor-condenser unit Up to 83 % savings on operating costs thanks to Mixed and Free Cooling modes 1.400 Annual energy consumption (kwh) 1.200 1.000 800 600 100% 400 200 17% 0 Outside temperature ( C) -16 0 14 Energy consumption with the use of Free Cooling and Mixed modes Energy consumption without Free Cooling using the example of an SALA0, based on the temperature profile of the city of Hamburg 32 16

STULZ SplitAir 3 Precision air conditioning unit for flexible installation Features of the SplitAir 3 Reduced operating costs thanks to: Free Cooling and Mixed modes Condensation pressure control Factory tested, filled with refrigerant and ready for operation from the very first day Highly flexible Ceiling or wall installation Variable air supply via the front or underside Optionally available with Free Cooling module Refrigerant R407C EU3 air filter Filter monitor C2020 microprocessor Easy installation and maintenance Automatic restart after power failure Outside air conditions 25/+50 C winter/summer Quiet operation Options High temperature operation up to 55 C with R134a Compressor soft start Electric heater Heat exchanger with anti-corrosive finish Installation kit for outdoor unit Air intake and blow-out grills Air duct for indoor unit WIB 1000 interface Advantages thanks to variable-speed EC compressor (SIL version) Maximum energy efficiency in partial load mode Constant supply air temperature Integrated compressor soft start Fast and precise reaction to the actual thermal load Long service life thanks to continuous operation without compressor on/off cycles Free Cooling Mixed mode Compressor operation Wall mounted SplitAir 3 Ceiling mounted SplitAir 3 17

STULZ FreeAir Retrofit Free Cooling units for indoor or outdoor installation Free Cooling retrofit solution for telecommunication infrastructures for indoor or outdoor installation Even today, comfort air conditioning units are still used for cooling in many base stations. This means that the possibilities of Free Cooling are not exploited, and unnecessarily large amounts of energy are used for air conditioning. To considerably cut the operating costs of base stations, these can be retrofitted with the Free Cooling unit STULZ FreeAir. The FreeAir and comfort units are monitored and controlled by the C102 microprocessor. Whenever the outside temperature allows, Free Cooling mode is activated and the comfort air conditioning units are switched off. FreeAir enables you to transform your existing system into an energy efficient solution at low cost. The return on investment for the retrofit is achieved especially quickly in containers where comfort air conditioning units are running 24 hours a day. The FreeAir units are plug and play and therefore immediately ready for connection and use. The units are available in two versions for maximum versatility FCL-IN for indoor installation and FCL for outdoor installation. FCL-IN Version for indoor installation Free Cooling Mixed mode Displacement Upflow Downflow Plug and play FCL Version for outdoor installation Up to 96 % savings on operating costs thanks to Free Cooling mode 700 Annual energy consumption (kwh) 600 500 400 300 100% 200 100 0-16 0 14 4% 32 Outside temperature ( C) Energy consumption of a system with Free Cooling Energy consumption of a comfort air conditioning unit without Free Cooling using the example of a 3.5 kw unit, based on the temperature profile of the city of Frankfurt am Main. 18

STULZ FreeAir Retrofit Free Cooling units for indoor or outdoor installation Features of the FreeAir Ready for operation on the very first day easy to install both mechanical and electrically Easy integration of existing comfort air conditioning units Outside temperature value for Free Cooling can be defined as you wish C102 microprocessor controls the entire system including comfort air conditioning units Speed-controlled EC fan Full service accessibility from the front Measures DC power consumption G4 air filter: The FCL-IN is equipped with a pocket filter, providing a large filtering surface (2 m 2 ). This reduces pressure losses and extends maintenance intervals Insulated, powder-coated housing of galvanized sheet steel The filter alarm can be triggered either by differential pressure or based on a manually adjustable fan operating time Options Aluminum or stainless steel housing Humidity sensor Weather-proofed excess pressure damper User-friendly LCD operator terminal for operation, installation and service External operator terminal with 3 x 7 segment display Paper and leaf guard for fitting to the air intake Support frame for secure mounting on thin walls (FCL only) Supply air grill with adjustable louvers (FCL only) Plenum/grill for fresh air supply aperture with metal pre-filter (FCL-IN only) WIB 1000 interface Installation of the FCL-IN The FCL-IN is installed indoors, for when maximum protection against vandalism and adverse weather conditions is your priority. FCL-IN For indoor installation Installation of the FCL The FCL is installed outside the container, so that the entire indoor space can be used for IT equipment. Full access from the outside for maintenance purposes. FCL For outdoor installation 19

Telecom Line Performance data of all models WallAir WallAir Model WDE40 WDE60 WDE80 WDEA0 WDEA2 WDEA4 WDEA6 WDI80 WDIA4 Airflow m³/h 1,100 1,700 2,700 2,400 2,800 3,600 3,600 2,700 3,600 Cooling capacity 1) kw 4.5 6.1 8.0 10.0 12.0 13.9 15.7 7.7 13.2 Noise level (external) 2) dba 50 51 52 53 54 58 60 52 58 Height/width/depth mm 2,085/879/565 2,085/879/565 2,085/879/565 2,226/992/730 2,226/992/730 2,226/992/730 2,226/992/730 2,085/879/565 2,226/992/730 Weight kg 170 200 210 240 240 250 250 230 250 Supply voltage 3) V/ph/Hz 400V/3 ph/50 Hz + 48V DC 1) Operating conditions: Indoor temperature 30 C, relative humidity 30 %, outside temperature 35 C. 2) Measured at a distance of 2 m, free field conditions. 3) Other voltages on request. Technical data subject to change without notice. TelAir 2 TelAir 2 Downflow, Displacement Model TLF/TLD40 TLF/TLD60 TLF/TLD80 TLF/TLD90 TLF/TLDA2 TLF/TLDA4 Airflow m³/h 1,000 1,500 2,000 2,200 3,000 3,200 Cooling capacity 1) kw 4.5 6.0 8.3 9.2 11.0 12.5 Noise level (internal/external) 2) dba 64/53 64/55 64/61 67/62 67/63 67/63 Height/width/depth mm 1,990/600/650 1,990/600/650 1,990/900/700 1,990/900/700 1,990/900/700 1,990/900/700 Weight kg 170 190 250 260 270 280 Supply voltage 3) V/ph/Hz 400V/3 ph/50 Hz + 48V DC 1) Operating conditions: Indoor temperature 30 C, relative humidity 30 %, outside temperature 35 C. 2) Measured at a distance of 2 m, free field conditions. 3) Other voltages on request. Technical data subject to change without notice. TelAir 2 Upflow Model TLU40 TLU60 TLU80 TLU90 TLUA2 TLUA4 Airflow m³/h 1,000 1,500 2,000 2,200 3,000 3,200 Cooling capacity 1) kw 4.7 6.1 8.4 9.5 11.2 12.6 Noise level (internal/external) 2) dba 64/53 64/55 64/61 67/62 67/63 67/63 Height/width/depth mm 1,990/600/650 1,990/600/650 1,990/900/700 1,990/900/700 1,990/900/700 1,990/900/700 Weight kg 170 190 250 260 270 280 Supply voltage 3) V/ph/Hz 400V/3 ph/50 Hz + 48V DC 1) Operating conditions: Indoor temperature 25 C, relative humidity 40 %, outside temperature 35 C. 2) Measured at a distance of 2 m, free field conditions. 3) Other voltages on request. Technical data subject to change without notice. 20

Telecom Line Performance data of all models SplitAir 3 SplitAir 3 Model SAL40 SAL60 SAL80 SALA0 SALA2 SALA5 SIL80 SILA5 Airflow m³/h 1,100 2,000 2,000 2,300 3,300 3,300 2,000 3,300 Cooling capacity 1) kw 5.2 6.7 8.4 11.5 13.6 15.7 8.1 13.0 Noise level (internal/external) 2) dba 60/48 62/49 62/50 62/51 63/53 63/53 62/50 63/53 Height/width/depth (indoor unit) 3) mm 350/850/1,160 350/850/1,160 350/850/1,160 410/1,040/1,370 410/1,040/1,370 410/1,040/1,370 350/850/1,160 410/1,040/1,370 Height/width/depth (outdoor unit) mm 695/1,050/492 695/1,050/492 695/1,050/492 1,334/1,050/491 1,334/1,050/491 1,334/1,050/491 695/1,050/492 1,334/1,050/491 Weight (indoor unit) kg 53 54 54 75 76 76 54 76 Weight (outdoor unit) kg 82 87 91 138 140 146 91 146 Supply voltage 4) V/ph/Hz 400V/3 ph/50 Hz + 48V DC 1) Operating conditions: Indoor temperature 30 C, relative humidity 30 %, outside temperature 35 C. 2) Measured at a distance of 2 m, free field conditions. 3) With Free Cooling module. 4) Other voltages on request. Technical data subject to change without notice. FreeAir FreeAir Model FCL/FCL-IN 35 FCL/FCL-IN 60 Airflow m³/h 1,050 1,750 Cooling capacity 1) kw 3.5 6.0 Noise level (external) 2) dba 44 46 Height/width/depth (indoor unit) mm 1,271/640/290 1,271/640/290 Height/width/depth (outdoor unit) mm 612/720/604 612/720/604 Weight (indoor unit) kg 35 35 Weight (outdoor unit) kg 35 35 Supply voltage V DC 48 48 1) Operating conditions: Indoor temperature 30 C, outside temperature 20 C. 2) Measured at a distance of 1 m, free field conditions. Technical data subject to change without notice. 21

PRODUCTION SITES Europe, America and Asia The humidity of the tropics and arid heat of the desert require completely different air conditioning solutions from the moderate climes of the Northern Hemisphere. And the demands of Europeans and Americans differ completely from those of Indians and Chinese. Only by producing in the relevant area can you know precisely what customers want. This is why STULZ has production sites in the world's major growth regions. All over the world, customers put their trust in product lines that answer perfectly to their requirements. Cooperating globally, producing locally: For every region, STULZ supplies tailor-made products for individual requirements. 22

Germany, Hamburg Europe Italy, Valeggio sul Mincio China, Shanghai China, Hangzhou India, Mumbai Asia USA, Frederick, Maryland America 23

STULZ worldwide Headquarters Germany Subsidiaries Australia Belgium China Germany France Great Britain India Italy Mexico New Zealand Netherlands Austria Poland Singapore Spain South Africa USA Production sites Germany China India Italy USA Partners www.stulz.com/worldwide STULZ financial figures Year STULZ was founded: 1947 Workforce of STULZ Klimatechnik, worldwide approx. 2,100 Sales volume of STULZ Klimatechnik, worldwide approx. 360 million euros Close to you around the world, with 17 subsidiaries, 6 production sites and sales and service partners in more than 120 countries In 1971 we began specializing in the development and production of precision air conditioning units and chillers for data centers. That's a wealth of experience gathered over 40 years and from many thousands of projects that we've implemented worldwide. We have systems and solutions for data centers of all sizes and with the most diverse requirements take advantage of our expertise! 24

German engineering ingenuity We put a great deal of experience and innovative spirit into developing our air conditioning systems. Engineers, specialist departments and sales employees work closely together, and our teams are involved through all stages of the development process, right up to completion of the finished product. We brook no compromise where the efficiency of our products is concerned, and cost effective operation is at the heart of our endeavors. STULZ air conditioning systems All STULZ Telecom Line units are designed for operation 24/7, 365 days a year, and offer maximum reliability and availability. Fast, smooth service is guaranteed by a worldwide network of specialist partners and subsidiaries. Quality standards STULZ ensures the best possible reliability by manufacturing its precision air conditioning units from high-quality components that meet our extremely rigorous quality standards. Every Telecom Line unit undergoes exhaustive live mechanical and electrical testing on our running test bench. This is how we guarantee 100 % reliability. In good hands with STULZ all over the world Individual planning assistance Global framework agreements Individual solutions Reliable delivery Fast reaction times thanks to our dense service and sales network 25

STULZ Company Headquarters D STULZ GmbH Holsteiner Chaussee 283. 22457 Hamburg Tel.: +49 (40) 55 85-0. Fax: +49 (40) 55 85 352. products@stulz.de STULZ Subsidiaries AUS AT BE BR CN E STULZ AUSTRALIA PTY. LTD. 34 Bearing Road. Seven Hills NSW Sydney 2147 Tel.: +61 (2) 96 74 47 00. Fax: +61 (2) 96 74 67 22. sales@stulz.com.au STULZ AUSTRIA GmbH Industriezentrum NÖ SÜD, Straße 15, Objekt 77, Stiege.4, Top 7. 2355 Wiener Neudorf Tel.: +43 (1) 615 99 81-0. Fax: +43 (1) 616 02 30. info@stulz.at STULZ BELGIUM BVBA Tervurenlaan 34. 1040 Brussels Tel.: +32 (470) 29 20 20. info@stulz.be STULZ Brasil Ar Condicionado Ltda. Rua Cancioneiro de Évora, 140. São Paulo-SP CEP 04708-010 Tel.: +55 11 4163 4989. Fax: +55 11 2389 6620. comercial@stulzbrasil.com.br STULZ AIR TECHNOLOGY AND SERVICES SHANGHAI CO., LTD. Room 406, Building 5, 457 North Shanxi Road. Shanghai 200040 Tel.: +86 21 3360 7101. Fax: +86 21 3360 7138. info@stulz.cn STULZ ESPAÑA S.A. Avenida de los Castillos 1034. 28918 Leganés (Madrid) Tel.: +34 (91) 517 83 20. Fax: +34 (91) 517 83 21. info@stulz.es F STULZ FRANCE S. A. R. L. 107, Chemin de Ronde. 78290 Croissy-sur-Seine Tel.: +33 (1) 34 80 47 70. Fax: +33 (1) 34 80 47 79. info@stulz.fr GB I IN MX STULZ U. K. LTD. First Quarter,Blenheim Road. Epsom. Surrey KT 19 9 QN Tel.: +44 (1372) 74 96 66. Fax: +44 (1372) 73 94 44. sales@stulz.co.uk STULZ S.p.A. Via Torricelli, 3. 37067 Valeggio sul Mincio (VR) Tel.: +39 (045) 633 16 00. Fax: +39 (045) 633 16 35. info@stulz.it STULZ-CHSPL (INDIA) PVT. LTD. 006, Jagruti Industrial Estate. Mogul Lane, Mahim. Mumbai 400 016 Tel.: +91 (22) 56 66 94 46. Fax: +91 (22) 56 66 94 48. info@stulz.in STULZ México S.A. de C.V. Avda. Santa Fe No. 170 Oficina 2-2-08. German Centre. Delegación Alvaro Obregon MX 01210 México Distrito Federal Tel.: +52 (55) 52 92 85 96. Fax: +52 (55) 52 54 02 57. ventas@stulz.com.mx NL STULZ GROEP B. V. Postbus 75. 1180 AB Amstelveen Tel.: +31 (20) 54 51 111. Fax: +31 (20) 64 58 764. stulz@stulz.nl NZ PL SG USA ZA STULZ NEW ZEALAND LTD. Office 71, 300 Richmond Rd.. Grey Lynn. Auckland Tel.: +64 (9) 360 32 32. Fax: +64 (9) 360 21 80. sales@stulz.co.nz STULZ POLSKA SP. Z O.O. Budynek Mistral. Al. Jerozolimskie 162. 02 342 Warszawa Tel.: +48 (22) 883 30 80. Fax: +48 (22) 824 26 78. info@stulz.pl STULZ SINGAPORE PTE LTD. 1 Harvey Road #04-00. Tan Heng Lee Building. Singapore 369610 Tel.: +65 6749 2738. Fax: +65 6749 2750. andrew.peh@stulz.sg STULZ AIR TECHNOLOGY SYSTEMS (SATS), INC. 1572 Tilco Drive. Frederick, MD 21704 Tel.: +1 (301) 620 20 33. Fax: +1 (301) 662 54 87. info@stulz-ats.com STULZ SOUTH AFRICA PTY. LTD. Unit 18, Jan Smuts Business Park. Jones Road Jet Park. Boksburg. Gauteng 1459 Tel.: +27 (0) 11 397 2363. Fax: +27 (0) 11 397 3945. aftersales@stulz.co.za 06-18 en STULZ GmbH, Hamburg Technical data subject to change without notice. 1100145 V1.3 IT Cooling Solutions Close to you all over the world With specialist, competent partners in our subsidiaries and exclusive sales and service partners around the world. Our six production sites are in Europe, North America and Asia. Digital version For more information, please visit our website www.stulz.com.