VT8600 Series Installation Guide Rooftop Unit, Heat Pump and Indoor Air Quality Controller

Similar documents
VT8300 Series Installation Guide 24 Vac Low Voltage

CONTENTS. Installation Guide. VT7200 Series

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide VT8600 Series Room Controllers

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide. SE8600 Series Room Controllers

SE7600W Series. Install Guide for Water Source Heat Pump CONTENTS

SE7200 Series Installation Guide

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

PIR Ready VT7200 Series 24 Vac Low Voltage Zoning Thermostats For Commercial HVAC Applications September 1, 2010

Models available. Features and benefits. Models available with internal humidity sensing Advanced occupancy functions

VT8000 Series Replacement Procedure to Replace VT8000 Series Room Controller and Pair with ZigBee Pro Sensors

Fan Coil Unit (FCU) Application Guide

Document # R01

SER7300 Series Installation Guide for HVAC FCU Applications

Models available. Features and benefits. 2 Heat / 2 Cool with economizer

TB7200 Series Communicating Zone Thermostats

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

TB7300 Series Communicating Fan Coil Thermostats 24 VAC/FOR COMMERCIAL AND LODGING HVAC APPLICATIONS

T600MEP-2 Programmable Economizer Thermostat

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

Document # R00

PIR Application Guide for the for VT76xxX5x00(X) Series thermostats (Issue Date: November, 2015)

TEC Networked Multi-Stage Economizer Thermostat

Installation Instructions. Applications. North American Emissions Compliance. Installation. Part No , Rev. Issued February 8, 2010

TEC BACnet MS/TP Networked Thermostat Controller with Single Proportional Output and One-Speed Fan Control

74 Humidity 66 % MultiSITE CRC1 Series Controllers INSTALLATION MANUAL. PREMTBVC0 MultiSITE CRC1 PREMTBVC1 MultiSITE CRC1+ Occ Auto Heat.

T-32-TS Touchscreen Thermostat. Installation Manual

Mx-MTB HVAC Controller

T60xDFH-3 and T60xDFH-3+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

VisionPRO 8000 with Wi-Fi

T606MSx-4 and T606MSx-4+PIR Series Multi-Stage

Installer Guide. WARNING Important Safety Information. 1 Specifications

VH7200 Humidistat Series For Humidification & Dehumidification Control For Commercial HVAC Applications (Issue Date January 22, R7)

TEC22x2-4 and TEC22x2-4+PIR LONWORKS Networked Heat Pump Thermostat Controllers

ExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling

Installation and Setup Guide

TEC and TEC PIR BACnet MS/TP Networked Multi-Stage Thermostat Controllers

TEC Networked Multi-Stage Thermostat

Installer Guide. WARNING Important Safety Information. 1 Specifications

Models Available. Features and benefits. Through the network or smart local occupancy sensing. Advanced occupancy functions


TEC20x7-2 Series Wireless Thermostat Controllers with Two Outputs

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFH24F3XYZ2 Stand-alone with Internal Humidity Sensor

Installation Instructions HEAT COOL FAN POWER

TEC and TEC PIR N2 Networked Single-Stage Thermostat Controllers

Z24 Wireless Zone Controller Professional Installation Guide

Product Catalog. Small Building Systems.

ENTOUCH ONE USER GUIDE

T62xx-0 Fan Coil Retrofit Thermostat Controller and R-xxxxx-0 Fan Coil Retrofit Relay Packs

TEC21x7-2 Series N2 Networked Thermostat Controllers with Two Outputs

INSTALLATION, OPERATION & QUICK START GUIDE

Networkable Fan Coil Controller Specification and Installation Instructions

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

User s Manual

Safety & Installation Instructions

TEC Networked Single-Stage Thermostat

Halton SAFE / 7.14 user guide and installation instructions

CM3500 Controller - ClimateMaster DOAS Water-Source Heat Pumps - Rev.: 7 Oct, 2008B

VT7600 Series Programmable & Non-Programmable Thermostats With Humidification & Dehumidification Strategy For Commercial HVAC Applications

Safety & Installation Instructions

NetworX NX-548E Receiver Installation Instructions

Omnistat3 Hospitality Energy Management Thermostat

Safety & Installation Instructions

TEC210x-2 Series Networked Thermostats

Brivis Touch Controller. Installer Manual

1.0 Digital Controller

Comfort System T-21-P Touchscreen Thermostat Installation Manual

INSTALLATION INSTRUCTIONS

Smart Temp. Model

Programmable Thermostat

TEC and TEC PIR BACnet MS/TP Network Multi-Stage Temperature and Humidity Controllers

TEC2664Z-2 BACnet MS/TP Rooftop Controller for Stand-Alone and Networked Zoning Systems Part No , Rev. C

TEC2100 Series Networked Thermostats

INTRODUCTION Thank you for purchasing your new Comfort-Set 90 Series thermostat. Your new White-Rodgers Thermostat uses solid state microcomputer

Safety & Installation Instructions

Commercial Touchscreen Thermostat

RC-2000 Thermostat Installation Instructions

Installation and Advanced Programming Instructions. HP8211-1RJ and HP8321-1RJ Heat Pump Thermostats

Factory Packaged Controls. MHGRV-X Controller Field Technical Guide

Introduction. What is the W2W Open controller?

FOR SERVICE TECHNICIAN S USE ONLY

Siemens Thermostats. RDY2000BN Thermostat

MicroTech Self-Contained Air Conditioning System

RS332N BUTTON OPERATION INTRODUCTION. Installation and Operation Instructions for REMOVING THE THERMOSTAT FROM THE BACKPLATE

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

EL-TSTAT-8820 Safety & Installation Instructions

Smart Temp. ApolloP/n Installation Manual. Version 1.0

± 3% or better at 40%RH and 23ºC [73ºF] 0.8 mm 2 [18 AWG] minimum

Table of Contents. WSHP Open v3

1F98EZ-1421, Easy Install

Siemens RDY2000BN. Start Up Guide

Pioneer Gold Controller Technical Guide

Product Manual SZ1009

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Product Manual SZ1022/SZ1031/SZ1035/

Factory Packaged Controls. MHGRV-X Controller Field Technical Guide

Owner s Manual. Part Number 33CSCPACHP-01

Safety & Installation Instructions

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat

Transcription:

Installation Guide Rooftop Unit, Heat Pump and Indoor Air Quality ontroller ONTENTS Installation 2 onfigurable BI/UI Universal Inputs Overview 3 Setup Screen Display 3 Terminal Identification & Function 4 Terminal identification 4 Typical Applications 5 2H / 2 5 2 / Mod. heat 6 Remote Sensor Accessories 7 Wiring example of single remote room sensor 7 Wiring examples of 2 remote room sensors 8 Wiring examples of 3 remote room sensors 9 Home Screen Display 10 How to Enter Setup Screen 11 Appendix 12

2 INSTALLATION Location Do not install on outside wall. Do not install in areas with direct heat source. Do not install near any air discharge grill. Do not install in areas exposed to direct sunlight. Ensure Room ontroller has sufficient air circulation. Ensure wall surface is flat and clean. Installation Guide Installation 1. Remove security screw (if any) on bottom of Room ontroller cover. 2. Open unit by pulling on bottom side of Room ontroller (Figure 1). 3. Read F ID and I label installed in cover before installing any wireless product. 4. Ensure correct side of base faces up. 5. Pull cables 6in ( 15cm ) out from wall. 6. Align base and mark location of two mounting holes on wall (Figure 2). 7. Install anchors in wall. 8. Insert cable in central hole of base. 9. Insert screws in mounting holes on each side of base. 10. Strip each wire 1/4in ( 0.6cm) from end. 11. Insert each wire and screw according to wiring chart (next page). 12. Gently push excess wiring back into hole. 13. Gently align cover to top of base and snap in place from bottom (Figure 3). 14. Install security screw. Figure-1 Open cover Figure-2 Install base If replacing an existing Room ontroller label wires before removal of ontroller. Electronic controls are static sensitive devices. Discharge yourself correctly before manipulating and installing Room ontroller. A short circuit or wrong wiring may permanently damage ontroller or equipment. All series controls are designed for use as operating controls only and are not safety devices. Tampering with the devices or unintended application of the devices will result in a void of warranty. This device must be installed to provide a separation distance of at least 8in (20cm) from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. Figure-3 Reinstall cover

Installation Guide ONFIGURABLE BI/UI UNIVEAL INPUTS OVERVIEW Universal input #16 can be configured for the following binary functions: 3 1. (None): No function associated with the input 2. (Rem NSB): remote NSB timer clock input. The scheduling is set as per the binary input. It provides low cost setback operation via a dry contact. ontact opened = Occupied ontact closed = Unoccupied 3. (Motion NO) and (Motion N): Advanced PIR occupancy functions using a normally open (NO) or normally closed (N) remote PIR motion sensor. Occupancy mode is now set as per applied PIR function and configuration. This document will provide the installers and system designers with detailed examples on applications, parameter configuration information, sequence of operation, troubleshooting and diagnostic help required for the proper usage of the onboard PIR sensor. 4. (Window) EMS: Forces the system to disable any current heating or cooling action by the Room ontroller. The mode stays the same and the current setpoints are the same occupied setpoints. Only the outputs are disabled. There is a Door/Window alarm displayed on the Room ontroller to indicate to the local tenant that the door/window needs to be closed for cooling or heating to resume. Use N contact. ontact opened = System disabled with local Window alarm ontact closed = System enabled 5. (Fan lock): a Fan lock alarm short text message shows on the Room ontroller screen when the input is not energized. Used in conjunction with a local airflow sensor connected to the input. Locks out the Room ontroller heating and cooling action if no airflow is detected 10 seconds after the fan ( G terminal ) is energized. ontact opened = no airflow ontact closed = airflow present Universal input #17 can be configured for the following binary functions: 1. (None): No function associated with the input. Input can be used for remote network monitoring. 2. (Door Dry) Door contact & Motion detector: This configuration is only functional if binary input #1 is set to Motion NO or Motion N or an onboard PIR sensor is used. With this sequence enabled, the occupancy is now dictated through those 2 inputs. Any motion detected will set the zone to occupied status. The zone remains permanently in occupied mode until the door contact switch opens momentarily. The Room ontroller will then go in stand-by mode. If more movements are detected, the occupied mode will resume. While the door is opened, any movements detected by the remote PIR sensor or the onboard PIR sensor will be ignored. Use a Normally losed contact switching device. ontact opened = Door opened ontact closed = Door closed 3. (Override): Temporary override remote contact. Disables all override menu function of the Room ontroller. The override function is now controlled by a manual remote momentarily closed contact. When configured in this mode, the input operates in a toggle mode. With this function enabled it is now possible to toggle between unoccupied & occupied setpoints for the amount of time set by parameter (TOccTime) temporary occupancy time. When Override is enabled, an Override status message will be displayed 4. (Filter): a Filter alarm short text message shows on the Room ontroller screen when the input is energized 5. (Service): a Service alarm short text message shows on the Room ontroller screen when the input is energized

4 TERMINAL IDENTIFIATION & FUNTION Installation Guide Terminal identification VT86xxU Description / Application Internal Temperature Used in applications IAQ, HP & RTU X 1- BO1 2- BO2 Y2 3- BO3 Y1 4- BO4 G 5- R R (24 Vac) 6-7- RH RH 8- BO8 W1 9- UO9 W2 / OB 10- UO10 Econo (0-10 Vdc) 11- UO11 Heat (0-10 Vdc) 12- UO12 UO12 (Optional 0-10 Vdc output, can be set from BAnet) 13-485 + BAnet (+) 14-485 - BAnet (-) 15-485 Ref BAnet Ref. 16- UI16 UI16 (multifunction input) 17- UI17 UI17 (multifunction input) 18 Scom 19- UI19 O2 (0-10 Vdc input) 20- UI20 (Remote sensor input 10K thermistor) 21 Scom 22- UI22 SS (Supply sensor input 10K thermistor) 23- UI23 OS (Outside sensor input 10K thermistor) 24- UI24 Airflow (0-10 Vdc input)

Installation Guide TYPIAL APPLIATIONS 5 RTU: 2 Heating Stages / 2 ooling Stages BO 1 - BO 2 - Y2 BO 3 - Y1 BO 4 - G R (24 Vac) () 1 2 3 4 5 6 RH BO 8 - W1 UO 9 - W2 UO 10 - Econo UO 11 - Heat UO 12 7 8 9 10 11 12 R O2 TRANSMITTER (0-10 VD) OUT R AIR FLOW MEASURING STATION (0-10 VD) EONO OUT W2 W1 R G Y1 Y2 FILTER DPS SAT SENSOR OAT SENSOR 13 14 15 16 17 18 19 20 21 22 23 24 BAnet + BAnet - BAnet REF UI 19 - O2 UI 20 - UI 22 - SS UI 23 - OS UI 24 - Airflow

6 Installation Guide RTU: 2 ooling Stages / Modulating Heat BO 1 - BO 2 - Y2 BO 3 - Y1 BO 4 - G R (24 Vac) () 1 2 3 4 5 6 RH BO 8 - W1 UO 9 - W2 UO 10 - Econo UO 11 - Heat UO 12 7 8 9 10 11 12 Mod. Heat (0-10 VD) R O2 TRANSMITTER (0-10 VD) OUT R AIR FLOW MEASURING STATION (0-10 VD) EONO R G Y1 Y2 OUT FILTER DPS SAT SENSOR OAT SENSOR 13 14 15 16 17 18 19 20 21 22 23 24 BAnet + BAnet - BAnet REF UI 19 - O2 UI 20 - UI 22 - SS UI 23 - OS UI 24 - Airflow

Installation Guide 7 HPU: 2 ompressors, iliary Heat and Economizer BO 1 - BO 2 - Y2 BO 3 - Y1 BO 4 - G R (24 Vac) () 1 2 3 4 5 6 RH BO 8 - W1 UO 9 - O/B UO 10 - Econo UO 11 - Heat UO 12 7 8 9 10 11 12 R O2 TRANSMITTER (0-10 VD) OUT R AIR FLOW MEASURING STATION (0-10 VD) EONO OUT O W R G Y1 Y2 FILTER DPS SAT SENSOR OAT SENSOR 13 14 15 16 17 18 19 20 21 22 23 24 BAnet + BAnet - BAnet REF UI 19 - O2 UI 20 - UI 22 - SS UI 23 - OS UI 24 - Airflow

8 Installation Guide REMOTE SENSOR AESSORIES Model Number S3010W1000 S3020W1000 Description Wall mounted temperature sensor Wall mounted temperature sensor with override button and occupancy status LED Note: If one or multiple sensor(s) is/are connected into the terminal, the internal temperature sensor is automatically disabled. Disconnecting the sensor(s) in terminal will re-activate the internal sensor. Remote mount temperature sensors inputs use 10K type 2 NT thermistors. Features: Each sensor can be configured for various averaging combinations Optional occupancy led Optional override key Wiring example of single remote room sensor Series ontroller 1xS3020W1000 Remote wiring 1 sensor S2-1= On, S2-2=On S3010W1000 Remote wiring 1 sensor S2-1= On, S2-2=On UI 20 - OR B0 1 - AUX () or ON 1 2 Dip switch setting for 1 sensor S2-1= On, S2-2=On

Installation Guide 9 Wiring examples of 2 remote room sensors for averaging applications 2xS3020W1000 2xS3010W1000 Series ontroller Remote wiring 2 sensors S2-1= Off, S2-2=On Series ontroller Remote wiring 2 sensors S2-1= Off, S2-2=On UI 20 - UI 20 - B0 1 - AUX B0 1 - AUX () () or or Series ontroller 1xS3010W1000 and 1x2xS3020W1000 Remote wiring 2 sensors S2-1= Off, S2-2=On Note for averaging applications: S3010W1000 and S3020W1000 can be mixed matched. UI 20 - B0 1 - AUX () S3010W1000 and S3020W1000 are to be wired in parallel. Respect the Dip switch setting in each remote sensor. or ON 1 2 Dip switch setting for 2 sensors S2-1= Off, S2-2=On

10 Installation Guide Series ontroller Wiring examples of 3 remote room sensors for averaging applications 2xS3010W1000 and 1xS3020W1000 Remote wiring 3 sensors S2-1= Off, S2-2=On UI 20 - B0 1 - AUX () or ON 1 2 Dip switch setting for 3 sensors S2-1= Off, S2-2=Off Series ontroller 1xS3010W1000 and 2xS3020W1000 Remote wiring 3 sensors S2-1= Off, S2-2=On UI 20 - B0 1 - AUX () or ON 1 2 Dip switch setting for 3 sensors S2-1= Off, S2-2=Off Temperature vs. resistance chart for 10 Kohm NT thermistor (R25 = 10KΩ±3%, B25/85 = 3975K±1.5%) º ºF Kohm º ºF Kohm º ºF Kohm º ºF Kohm º ºF Kohm -40-40 324.3197-20 -4 94.5149 0 32 32.1910 20 68 12.4601 40 104 5.3467-35 -31 234.4009-15 5 71.2430 5 41 25.1119 25 77 10.0000 45 113 4.3881-30 -22 171.3474-10 14 54.1988 10 50 19.7390 30 86 8.0694 50 122 3.6202-25 -13 126.6109-5 23 41.5956 15 59 15.6286 35 95 6.5499 55 131 3.0016

Installation Guide 11 HOME SREEN SPLAY Typical Hospitality User Interface Shown Date Occupancy Status Indoor Temperature Time System Status Fan Status Up Arrow Increase Temperature Setpoint Actual Setpoint Outdoor Temperature System Mode Short Network Message Down Arrow Decrease Temperature Setpoint Help Fan Mode Language Selection Temperature Units Note: User HMI is configurable and allows display functions such as Outdoor Temperature, Setpoint, and other buttons to be enabled or disabled by setting various parameters in the setup screens.

12 Installation Guide HOW TO ENTER SET-UP SREEN Touch and hold this point for 3 seconds to enter set-up mode Note: If a configuration/installer password is activated to prevent unauthorised access to the configuration menu parameters, a password entry prompt shows to prevent access to device configuration components. For more information on using and configuring the functions of the HMI, refer to the User Interface Guide SET-UP SREEN SPLAY 1/2 Setup Note: The "Network" button does not show if no BAnet or ZigBee card is installed. Network onfiguration Setpoints - Display Service View Test Outputs Language Selection Enter BAnet & ZigBee network settings Enter parameter configuration menu Enter setpoint & display settings Enter status and service view Enter output testing mode Enter language selection Return to home screen Discover Mode The ontroller becomes discoverable on the wireless ZigBee network for 1 minute (this button is hidden if ZigBee settings are not configured) General Note: Adjustable parameter Non-adjustable parameter

Installation Guide 13 APPENX A TERMINAL ORRESPONDANE The terminals of an are identified diifferently and have a wider range of possible functions compared to those of any of the VT7000 series Room ontrollers. There is a direct correspondance of functions between the terminals of the VT7000 series and the series. onsult the table below to verify the appropriate terminal when replacing a VT7000 Room ontroller with a Room ontroller. VT7000 Terminal name Terminal ID Terminal name Terminal ID Binary Input 1 BI1 Universal Input 16 UI16 Binary Input 2 BI2 Universal Input 17 UI17 Universal Input 3 UI3 Universal Input 19 UI19 Sensor Scom Terminal 18 OM Remote Sensor Universal Input 20 UI20 - Sensor Scom Terminal 21 OM Mix/Supply Sensor MS Universal Input 22 UI22 - SS APPENX B POWER OUTAGE LOK RESET In the event of a power outage, Room ontrollers will retain the correct time as long as the duration of the power outage is not prolonged. Depending on the duration of the power outage, the Room ontroller's internal clock may need to be updated or reset completely. The following table gives an indication of the expected clock performance after a power outage. Outage duration Room ontroller behaviour 0-24 hours lock functions are normal 24-36 hours lock accuracy not guaranteed, time may need to be adjusted 36-72 hours lock no longer increments and must be adjusted when power is restored 72+ hours lock functions are fully reset, and must be reinitialized as per a new installation