CONVENTIONAL FIRE ALARM CONTROL PANEL

Similar documents
intelligent solutions

OPERATION AND INSTALLATION MANUAL

TABLE OF CONTENTS TABLE OF CONTENTS 1

Installation, Operating and Maintenance Manual

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Excel-EN Conventional Fire Control Panel

System 800 Addressable Fire Detection & Alarm System

FEC400 Series. Installation Manual

Door Release Power Supply

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

EVO192 v3.0 Fire and Burglary What s New

User Operation Manual

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

Application, Installation, Operation & Maintenance Manual

MAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

MR-2602 Two Zone Fire Alarm Control Panel

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Specification/ Data Sheet

Commercial and Light Industrial Fire Alarm Control Panel

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

QA16 Addressable System

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Conventional Fire Alarm System 2014 V1.2

Addressable Fire Alarm Control Panel

ESP TECHNOLOGIES LIMITED

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

PANEL_RS2. Run / Standby Panel. INSTALLATION MANUAL Version 1.02 MITSUBISHI ELECTRIC FOR INSTALLERS. Page 1 of 25

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

Intelligent Security & Fire Ltd

Sita200plus. 200detectors. Single loop analogue addressable System

Precept Marine Control Panel Application Guide

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

LF-4000 Series Conventional Fire Alarm Control Unit

Intelligent Security & Fire Ltd

Building Name: Our Lady of Sorrows Date: July 10, 2013

Fire Control/Communicator

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

Open-area Smoke Imaging Detector. Engineering Specification

Control Panel User Guide

INSTALLATION MANUAL PC56O. Version 1.OA

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

SECURIT 703 USER MANUAL

Intelligent Security & Fire Ltd

D2071A. Operation & Installation Guide Fire Alarm Control Panel

The EN54 Part 2 and 4 Fire System

SFC-200 SERIES LED FIRE ALARM PANEL

The supplier and installer of the system should be approved by the local civil defence authority.

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

Installation Manual Premier 412/816/832. Issue 10

EFBW series - BiWire Ultra control panel

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

SALES SUPPORT DOCUMENT

BSR Addressable Fire Detection control panel. Installation operation manual

Intruder - Fire - Water Combined Alarm

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

30.45 Electric Release PDRP-2001

FireShield Plus. GE Security. EST Life Safety & Communications Conventional Small Building Solutions. Conventional Fire Alarm Control Panels

SPECIFICATIONS Control Panel Specifications Remote Keypad Specifications 21 zones including: (PC3000RK) Audible alarm output:

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

FireNET Plus Wiring Instructions

To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator.

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

Conventional Leaflets

good things in small packages

Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA USA

Model 17A00 Expansion Enclosure

Remote alarm unit Art. Nr.:

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

FA-300 Series. LED Fire Alarm Control Panel. User Guide. FA-300 SERIES Fire Alarm Control Panel. FA-300 SERIES Fire Alarm Control Panel

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

SACE PR021/K SIGNALLING UNIT

End To End Optical Beam Smoke Detector. Additional Information

Fire Alarm Control Panel. System Maintenance and Log Book

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

LifeAlarm Fire Alarm Controls

SECURIT 700L PLUS ENGINEERING MANUAL

FA-101U Fire Alarm Control Panel

INTELLIGENT FIRE ALARM CONTROL PANEL

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Conventional Releasing Control Panel

Technical Data Sheet

Control Panel Engineering and Commissioning Instructions

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

Transcription:

CONVENTIONAL FIRE ALARM CONTROL PANEL 1PM2 Series Features Description 1PM2 The 1PM2 is a conventional fire alarm panel with a stylish wall-mount design supplied in 10 to 60 zone formats. All detector circuits will be indicated with lighting red s in alarm conditions and flushing in open circuit fault conditions. Slide-in paper labels are included for clear zone identification. The alarm panel has an alarm delay function on every detector circuits to reduce false alarms, including a zone-byzone settable delay ON/OFF function. 1PM2 features a re-sounding function of panel buzzer by reception of any subsequence input from manual alarm stations or other zones ensuring an announcement of a fire spread after the buzzer silenced. The alarm panel also has a maintenance switch to enable installation or maintenance works to cut off the panel buzzer and zone alarms. 1PM2 to be equipped with a CPU for securing high reliability features also a CPU trouble back-up function. Even when the CPU falls down, basic functions are secured to indicate alarm zones, to sound alarms and to transmit the alarm signal. The power consumption reduced 70% compared with Nittan s previous models contributes to cost reduction. 10 to 60 zone model available Extra slim design Highly reliable design by adopting durable indicators and CPU 10 to 20 circuits for zone alarm bells available (depends on the model on purchased) Alarm delay function Alarm delay ON/OFF switch function Trouble monitoring function CPU trouble back-up function Re-sounding mode of a panel buzzer Equipped with high protection for Lightning surge Interrupting function for emergency announcements to silence zone alarms 3 alarm indicators for indicating the alarm inputs from building facilities such as hydrants CPU trouble back-up function Capability of transmitting the second fire signal Signal transmit for Emergency PA facility also equipped Easy wiring by Push-in terminals one-touch connection Remote Test Function Remote test function is available on 2KAH3-P and 2KAD3-P detectors etc. with a dedicated testing device. * Operating Image 2KAH3-P - Distinguishes steam and smoke - Automatic sensitivity compensation - Suitable for Shower rooms and Kitchens 2KAD3-P - Remote-test available - Automatic sensitivity compensation - Suitable for Condominiums Nittan reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. 1PM2-DAT-01 Rev.1

Main Features 1. High reliability, advanced fire detection Re-sounding mode of panel buzzer Alarm delay ON/OFF function After Panel alarm silence by operator at fire, the panel buzzer automatically re-sounds by operation of manual alarm stations or by receipt of alarm signal from other zones to announce fire spread. Alarm delay function can be cancelled zone by zone individually. CPU trouble back-up function Outputs for Emergency PA system Even when CPU is down, basic function is carried on, fire signal can be received, zone indication, alarm sounding, fire alarm signal transmission, etc. Outputs for interlocking to Emergency PA system are provided as standard. 2. Advanced functions for easy installation and maintenance Lightning surge protection Alarm delay ON/OFF switch Lightning surge protection devices are provided as standard to main circuits to protect semiconductor parts. This switch can make the alarm delay function ineffective for installation and mainenance work. Maintenance switch (All alarm silence) Push-in type terminals At maintenance work, unnecessary alarm sounding can be cut off by operating the maintenance switch (except telephone calling sound). Clicking sounds is made when the maintenance switch is ON to draw operator s attention. Push-in type terminals are employed to improve efficiency at installation. Auto reset switch When operation test of detectors and manual alarm stations are conducted, by pressing auto reset switch to the reset side, fire test can be conducted zone by zone and the tested detector and the control panel shall be automatically reset. Self-checking function Monitoring; Detector line open-circuit Circuit voltage low CPU trouble Fuse blow Disconnection of Standby battery Emergency PA line open-circuit. Page 2 of 6 1PM2-DAT-01 Rev.1

Indicators on Operation Panel [1] [6] [7] [2] [10] [15] [3] [4] [5] [11] [12] [13] [16] [17] [8] [9] [14] [18] [19] [20] [21] [22] [23] [24] [25] [26] [27] [1] FIRE (Red) turns on when the panel is in an alarm condition. [2] AC POWER (Green) turns on when AC power is supplied to the main power circuit. [3] CIRCUIT VOLTAGE (Green) turns on as long as the main circuit voltage of the control panel is within acceptable levels (approx. 20.4 V and greater). [4] SWITCH OPERATION (Red) flashes when the panel switches are ON or not normal state. [5] TELEPHONE (Green) turns on when a handset is plugged into a telephone jack of a manual alarm station or an annunciator panel. [6] MAINTENANCE (Red) turns on during a maintenance mode. [7] ZONE ALARM SILENCE INDICATOR (Red) flashes when zone alarms are silenced. [8] PANEL ALARM SILENCE switch Activation of this switch when a panel buzzer is sounding, turns off the sounding buzzer. [9] ZONE ALARM SILENCE switch Activation of this switch makes zone alarms silenced. [10] ALARM DELAY (Red) turns on during a delay time of 60 sec, and flashes during a general alarm delay switch is OFF. [11] CPU TROUBLE (Red) turns on when the CPU is in a fault state. [12] FUSE FALUT (Red) turns on when a fuse for zone alarm outputs is blown. [13] BATTERY FAULT (Red) turns on when a standby battery is not connected to the panel. [14] EMERGENCY PA (Red) flashes during emergency PA announcements, and turns on when an open circuit is detected on the emergency PA lines. [15] MANUAL ALARM STATION (Red) turns on when a manual alarm station is activated. [16] HYDRANT OPERATION (Red) flashes while a hydrant pump(s) is in operation. [17] Other Alarms (Red) Each of the s turns on when the panel receives alarm signals from building facilities via LXn-C contacts. [18] RESET switch Activation of this switch resets the panel condition. [19] ALARM TRANSMISSION ISOLATION switch Activation of this switch isolates an alarm signal transmission through GA-GB-GC contacts. [20] GENERAL ALARM switch Activation of this switch activates all the zone alarms and outputs alarm signals to an emergency PA facility. [21] HYDRANT STATION ISOLATION switch Activation of this switch isolates an alarm signal transmission through H-H contacts. [22] EMERGENCY PA ISOLATION switch Activation of this switch isolates an alarm signal transmission to an emergency PA facility. [23] FIER TEST switch Use this switch for conducting a fire indication test. [24] ZONE SELECTION TENS DIGIT switch This switch sets tens digit of testing zones during a fire indication test. [25] ZONE SELECTION ONES DIGIT switch This switch sets ones digit of testing zones during a fire indication test. [26] AUTO RESET switch Activation of this switch enables a non-latching test function which allows manual alarm stations and detectors to be tested and the panel to resets automatically. [27] BATERY TEST switch Activation of this switch enables a standby battery test. Page 3 of 6 1PM2-DAT-01 Rev.1

Typical Wiring Diagram For Detectors and Manual Alarm Stations For Announciator For Fire Alarm Signal Transmit For Reset Pulse Transmit For Building Facilities For Zone Alarm Bells For Emergency PA System For Indication Lamps For Hydrant Pump Starter For Primary Power Source For Earth Connection Fire Alarm Zones (24 VDC+) Fire Alarm Common (-) L1 Ln C Telephone (+) T T Response Lamp (24 VDC+) A C Fire Alarm Zone Indication (-) Announciator Buzzer Silence (-) IC IC Announciator Buzzer (-) IB IB Announciator Power Supply (24VDC+) I+ I+ Common Fire Alarm Signal (Works compulsorily) Fire Alarm Signal (Isolation switch available) Normally Closed (System Reset=Transmit a pulse) Other Alarm Input Other Alarm Common Other Alarm Signal Transfer (Non-Voltage, N/O) Zone Alarm Output (24 VDC+) Zone Alarm Common (-) Zone Block Output I1 In F F' GA GB GC N N' LX1 LX2 LX3 C XA XC B1 Bm BC EA1 EAn I1 In EL1 ELn For Emergency PA Common EC EC First Alarm Signal Transfer EF1 EF Second Alarm Signal Transfer EF2 Microphone Operating Input EB EB *5 (Silences zone alarms) EB' EB' Power Output (25 VAC) Output for Start H H (Non-Voltage, N/O) H' H' Input for Confirmation of Start XL XL (Pump Activation=25VAC Input) XL' XL' Power Input (220 VAC) GA F F GC GB XA H H XC PL PL' P1 P2 E Fixed Temp. Heat Security System, etc. Fire Extinguishing System, etc. B 220 VAC Exclusive Power supply L L L L ROR *1 S P CRE *2 Heat Smoke C C C C P L *3 I+ Announciator Emergency PA System Hydrant Pump Starter B AL AL' Fire Protection System, etc. B T F F' N N' *4 A *1: P = Manual Alarm Station *2: The CRE is a dedicated end-of-line device which comes with the 1PM2 fire alarm control panel. *3: Make sure to be used F-F and N-N terminals when use Remote indication lamps. *4: Use the motor bells rated at 10 ma, 24 VDC. *5: The end-of-line resister comes with the 1PM2 fire alarm control panel. Page 4 of 6 1PM2-DAT-01 Rev.1

Dimensions 20 zones cabinet 450 100 40 zones cabinet 450 100 60 zones cabinet 450 100 1060 1250 760 Specifications 1PM2-nLA Number of Zones 10 20 30 40 50 60 Number of Bells (10 ma) 20 30 Number of Bell Blocks 10 15 20 Primary Rated Current (220VAC) 0.39 A Standby Battery 0.45 Ah 1.2 Ah Mounting Type Wall-mounting type Dimensions (mm) W 450 x H 760 x D 100 W 450 x H 1060 x D 100 W 450 x H 1250 x D 100 Weight 18 kg 25 kg 30 kg Notes Not included: Dedicated Battery, Telephone Handset Ordering Information Model Description PTL-1 Telephone Handset Nicd-battery (0.45AH) Ni-Cd Battery (0.45AH) for 1PM2-10LA 30LA Nicd-battery (1.2AH) Ni-Cd Battery for (1.2AH) for 1PM2-40LA 60LA PSH-nL Annunciator Panel with n Zone 2KH2-LS Optical Smoke Detector CKLD-KPT Beam Type Smoke Detector LP05 Remote Station for Beam Detector 1CD-70-LS Fixed Temp. Heat Detector, 70 C 2SC-LS Rate of Rise Heat Detector 2KAH3-P Dual Wavelength Type Optical Smoke Detector with Remote testing function 2KAD3-P Optical Smoke Detector with Automatic sensitivity compensation and Remote testing function MTS2 Remote Testing and Address Setting Device for 2KAH3-P, 2KAD3-P and others LP01/1 Remote Station for MTS2 3T Common detector Base for LS type detector B6T2 Common detector Base for LS type detector for connecting a remote indication lamp B3-J Detector Base for 2KAH3-P, 2KAD3-P, and others 1MF1A Manual Alarm Station with telephone jack BD-6-24-11 Local Alarm Bell (10 ma) PL-R4- Indication Lamp ( type) AL-4-24 Remote Indication Lamp SRT-01M6L-47SGB Local Combined Box (vertical type) with telephone jack c/w Surface Mounting Box Page 5 of 6 1PM2-DAT-01 Rev.1

Specifications Specifications AC Power 220 VAC ±10% 50/60 Hz 1PM2-nLA Sealed Type Ni-Cd battery Standby Battery 10LA - 30LA Panel : 0.45 Ah 40LA - 60LA Panel : 1.2 Ah Power Consumption 39 VA Nominal Delay Time 60 sec. (For smoke detector: 60 sec. For heat detector: 20 sec.) Dimensions 10L - 20L Panel : W 450 x H 760 x D 100 mm 30L - 40L Panel : W 450 x H 1060 x D 100 mm 50L - 60L Panel : W 450 x H1250 x D 100 mm Indicators Fire alarm, AC power, Circuit voltage, Switch operation, Telephone, Maintenance, Zone alarm silence, Alarm delay, CPU trouble, Fuse fault, Battery fault, Emergency PA, Manual alarm station, Hydrant operation, Other alarm (3 windows) Functions CPU fault monitoring, Fuse fault indication, Cable break monitoring External Line Resistance 50 Ω and less End of Line Device CRE Panel Alarm Sounder Piezoelectric buzzer, automatic re-sounding type Trouble Alarm Detector line open-circuit, CPU trouble, Zone Alarm Fuse blows, No battery connected, Emergency PA line open-circuit, Alarm inputs from external equipment Fire Alarm Transmission Contact Capacity Common Fire Alarm : F-F (Normally-Open) 1 A 24 VDC Fire Alarm : GA-GB-GC (Form-C) 1 A 24 VDC Reset Pulse : N-N (Normally-Close) 1 A 24 VDC External Equipment Alarms : XA-XC 1 A 24 VDC Emergency PA : EC EF1 EF2 EA1-EAn* EB EB (Normally-Open) 1 A 24 VDC *n: 10LA=10, 20LA-40LA=15, 50LA-60LA=20 Output Current for Zone Alarms (Bell) 24 VDC 10LA-30LA: 200 ma 40LA-60LA: 300 ma Output Current for Indication Lamps 25 VAC 400 ma Number of Connectable Detectors Standard type Smoke detector: Max. 40 /zone, Total 20 x zones Heat detector: As required Thermistor type Heat detector: Max. 24 /zone, Total 12 x zones Detectors with test function: Max. 20 /zone, Total 10 x zones Connectable Manual Alarm Station 1MF1A 1MI1A Connectable Annunciator Panel Model PSH x 1 unit Operating Temperature 0 C to +40 C Primary Materials Main Body: SPCC t1.6 Door: SPCC t1.2 Operation Panel: Flame retardant resin Body Color JPMA Color Code A22-90B Semi-gloss (off-white) Page 6 of 6 1PM2-DAT-01 Rev.1