CONVENTIONAL FIRE CONTROL PANELS FS 5100 and FS 5200

Similar documents
Fire Control Panel FS5100

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

REPEATER FS5200R INSTRUCTION MANUAL

REPEATER FS5200R OPERATION MANUAL

Fire Control Panel FS4000

Interface Module RS232/485. INTERFACE MODULE RS232/485 Instruction Manual 03-INT-02-17

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Extension Module. Fig.1

Fire Control Panel FS4000

System 800 Addressable Fire Detection & Alarm System

Fire control panel detect 3004 plus and accessories

UniPOS Wireless Fire Alarm Control Panel VIT 01 WIRELESS FIRE ALARM CONTROL PANEL VIT01 INSTRUCTION MANUAL

Intelligent Security & Fire Ltd

Security Alarm Systems

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

"DMTeh" Ltd. Pleven. Fire conventional panel FP 9000 Installation, setup and operation.

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

ACP10 & ACP50 Security Systems

Gas Detection System TOX ALARM DG2000-Garage

Intelligent addressable fire alarm control panel

SALES SUPPORT DOCUMENT

P R O D U C T D ATA S H E E T

intelligent fire alarm ID60series panels

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

ZXSe Range Data Sheet

SCAN200E USER S MANUAL

Remote alarm indicator and test combination MK2430

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

The EN54 Part 2 & 4 Fire System

TS5160. Installation & User Guide. Compatible Equipment. CPA6 0M - Output Module Loudspeaker DC54/58 - Digital Communicators (Stand Alone Only)

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

SI120 Guarto Easy I. Alarm system. Fire & Security Products

ID50series. intelligent fire alarm panels

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Product Data Sheet. Remote Terminals. Features:

DS7400Xi Addressable Control/ Communicator

2200 and 2200L ALARM CONTROL SYSTEMS

Excel-EN Conventional Fire Control Panel

Sita200plus. 200detectors. Single loop analogue addressable System

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

CONTENTS Installation Precautions... 1 Chapter 1 Product Introduction... 2 Chapter 2 Technical Specifications... 3

QA16 Addressable System

SCAN20 Series Gas Detection Controller

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Gas Controller Module GC-06

Fire control panels FC726 FC726-XA

TrueAlarm Fire Alarm Controls

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

INTELLIGENT FIRE ALARM CONTROL PANEL

1.7. Insulation fault evaluators EDS460/490 EDS461/491

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

CSP-204 CSP-208 CSP-104 CSP-108

UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers

Solution F2. Fire Alarm Control Panels one step ahead.

XC10 Extinguishing control panels

Variable Frequency Drive SERIES MP800 VFD

Advanced FireAlarm Panel 1-4Loop

Across-the-Line SERIES MP300 Combined Manual and Automatic

Fire control panels FC360

OJD ITB No Attachment E Duress Alarm Equipment Specifications

16 and 16 plus User s Guide

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Multi-Gas-Controller MGC2

Configuration and Operation Manual for the Unipos

PERMACONN PM1030 Includes DI300. Installation Manual

1.7. Insulation fault evaluators EDS460/490 EDS461/491

HRX Technical Manual. Version 1.2

561-MB48. Intruder Alarm Control Panel

Server Zones Setup in IFS IFS Panel Summary IFS loops panel specification:

Fire Detection Systems Product Catalogue (Version )

561-MB256 plus. Intruder alarm control panel. Performance features

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

The supplier and installer of the system should be approved by the local civil defence authority.

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM

Intelligent 2 & 4 Loop Fire Alarm Control Panels

600 Range Dialer Installation Manual. Version 1.0

Soft Start Series MP700 Solid State, Reduced Voltage

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Parameterisable compact fault annunciator with permanent display

Addressable and Conventional Fire Protection

CONTROL PANELS. Tech Data Sheet D01688GB1 10/2012 Fire Detection. Control Panels of the FX 3NET (ALC) Fire Detection System

Chlorine gas leak detector

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

Lift Station Level Controller

Intelligent Single Loop Fire Alarm Control Panel

Product Catalogue. Intelligent Control Equipment for Life Safety. Issue 1

ZSC100 Gas Detection and Alarm System Controller

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

PolyGard Digital Gas Controller DGC-05 RS-485 Bus

Transcription:

CONVENTIONAL FIRE CONTROL PANELS FS 500 and FS 500

BASIC FEATURES Fire Control Panels FS 500 and FS 500 are up-to-date, highly reliable, multifunctional and versatile units, providing the user with unexpected potential in the design, installation and operation of conventional fire alarm systems. Their main features and possibilities are: Adjustment of operating modes and parameters of each fire alarm line via built in keypad User oriented menu dialogue for easy and convenient operation LCD display for visualization of system checkup and setup modes LEDs indication for early warning of a break down or extreme conditions Energy independent archive memory saving the event type, date and time up to 84 events (FS 500) and up to 56 events (FS 500) Built-in serial interface for connection to second level control devices, ability for connection via telephone line and standard modem System expansion and functional modification (our goal is discontinuous improvement of the fire alarm equipment features), no additional cabling necessary Compatible to random installation design, within the range of fire control panels resources Control over fire alarm lines and controllable outputs for fault conditions (short circuit and interruption) and automatic reset Detection of removed fire detector in a line and automatic reset Ability to set the lines in dependency of the function "Logical AND" Group addressing of manual call points and automatic fire detectors Two phases of Fire condition, programmable time for Fire condition stage I, separately for each line Option to prolong the time period for Fire condition stage I with a programmable overall inspection period Built-in sounder for fire condition one tonal, continuous, can be switched off Built-in sounder for fault condition one tonal, discontinuous, can be switched off Built-in real time clock Set of test modes and options for adjustment: Setting the clock Check up of light and sound indications Test of fire alarm lines Adjustment of outputs and the integrated external devices Measuring the current value in the fire alarm lines Programming of parameters and modes of operation Remote programming of parameters from a distant operator control point Communication interface for external devices - RS-3 (directly or via modem) or RS-485

TECHNICAL DATA FIRE ALARM LINES - Maximum number of fire detectors in a line 3 3 - Connecting line two-wire two-wire - Maximum resistance of a line 00 00 CONTROLLABLE - Type potential potential - Electrical characteristics (4±5)V/00 ma (4±5)V/500 ma RELAY FOR FAULT CONDITIONS - Type potential free, potential free, switching switching - Electrical characteristics 3 A/5 V AC; 3 A/30 V DC 3 A/5 V AC; 3 A/30 V DC RELAY FOR FAULT CONDITIONS - Type potential free, potential free, switching switching - Electrical characteristics 3 A/5 V AC; 3 A/30 V DC 3 A/5 V AC; 3 A/30 V DC INDICATIONS OF REGISTERED EVENTS - Light indication LEDs LEDs - Text messages LCD display - LCD display - line, 6 symbols, 4 lines, 0 symbols, Latin/Cyrillic characters, backlit - Sound Built-in sounder Built-in sounder Latin/Cyrillic characters, backlit ACCESS LEVELS TO CONTROL FUNCTIONS 4 (in compliance with EN 54/) 4 (in compliance with EN 54/) - Voltage 0/30 V 0/30 V - Frequency 50 Hz 50 Hz BACKUP BATTERIES õ V / 7 Ah õ V / Ah OPERATION IN DUTY MODE UPON INTERRUPTED MAINS SUPPLY - Minimum configuration 46 h 80 h - Maximum configuration 3 h 30 h CONSUMPTION ON BACKUP BATTERIES SUPPLY IN DUTY MODE AT 4 V - Minimum configuration <50 ma <55 ma - Maximum configuration <0 ma <400 ma TO EXTERNAL DEVICES - Voltage (4±5)V (4±5)V - Maximum current value FS 500 FS 500 (current of controllable outputs included),3 À,5 À WEIGHT (BACKUP BATTERIES NOT INCLUDED) 5, kg 6,6 kg DIMENSIONS 445 õ 37 õ 87 mm 450 õ 355 õ 5 mm î î î î OPERATING TEMPERATURE -5 Ñ to +40 Ñ -5 Ñ to +40 Ñ RELATIVE HUMIDITY to 93 % to 93 % DEGREE OF PROTECTION IP 40 IP 40

TYPES OF S OF FIRE CONTROL PANEL FS 500 BASIC fire alarm lines controllable outputs relay outputs for fire condition relay output for fault condition 50 3 fire alarm lines 3 relay outputs for fire condition 50 6 fire alarm lines 3 relay outputs for fire condition FOR MODEM INTERFACE RS 3/ RS 485

COMFIGURATIONS OF FIRE CONTROL PANEL FS 500 FOR MODEM INTERFACE RS 3/ RS 485 BASIC ADDITIONAL 50 (50) S FEATURES CONFIGURATIONS BASIC POWER SUPPLY 50 50 FIRE ALARM LINES LINES RELAY FOR FIRE CONDITION RELAY CONDITION MINIMUM - - EXPANDED - 5 5 MAXIMUM - 8 5 Each configuration can be supplemented with INTERFACE and FOR MODEM.

TYPES OF S OF FIRE CONTRO PANEL FS 500 BASIC 8 fire alarm lines controllable output relay outputs for fire condition relay output for fault condition 50 8 fire alarm lines 50 8 fire alarm lines controllable output 503 8 relay outputs for fire condition 504 6 relay outputs for fire condition FOR MODEM INTERFACE RS 3/ RS 485

CONFIGURATIONS OF FIRE CONTROL PANEL FS 500 BASIC INTERFACE RS 3/ RS 485 50 FOR MODEM 50 503 (504) 50 S FEATURES CONFIGURATIONS POWER BASIC 50 SUPPLY 50 503 504 FIRE ALARM LINES CONTROLLABLE RELAY FOR FIRE CONDITION RELAY FOR FAULT CONDITION 00 (minimum) 8 0 8 0 0 8 8 03 6 04 6 0 05 6 8 06 4 07 4 0 08 4 8 09 3 0 3 0 (maximum) 3 8 Each configuration can be supplemented with INTERFACE and FOR MODEM.

4 Grenaderska Str, Pleven 5800, Bulgaria tel./fax +359 64 800 055; 80 880 e-mail: office_pleven@unipos-bg.com Mladost, bl. 79b, ent., ap.7 Sofia 784, Bulgaria tel./fax +359 9744469, 974395 e-mail: office_sofia@unipos-bg.com www.unipos-bg.com 0406V