Conventional Fire Alarm System Product Range Guide

Similar documents
intelligent solutions

Specification/ Data Sheet

FireNET Plus Wiring Instructions

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

Installation, Operating and Maintenance Manual

30.45 Electric Release PDRP-2001

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

good things in small packages

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

LifeAlarm Fire Alarm Controls

FEC400 Series. Installation Manual

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Addressable Fire Alarm Control Panel

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

ORENA BRAND CONVENTIONAL (ORENA Brand) CE

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

PSN-1000 & PSN 1000(E) Installation Manual

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

TECHNICAL DATA OBSOLETE

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

OPERATION AND INSTALLATION MANUAL

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

Installation Guide for models:

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

HP101U Conventional Fire Alarm Control Panel Installation And Operation Manual

Conventional Releasing Control Panel

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

Commercial and Light Industrial Fire Alarm Control Panel

Installation Guide for models:

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

Agent Release Control Panel

Intelligent addressable fire alarm control panel

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

MS-2410BC. Conventional Fire Alarm Control Panel. Programming, Installation, Maintenance and Operating Instruction Manual

Release Control Fire Alarm Systems

ECC-50/100C. Emergency Command Center

July 14, 1999 DF C-100.

System 800 Addressable Fire Detection & Alarm System

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

LifeAlarm Fire Alarm Control Panels

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Technical Speci fications 220V AC 50Hz or 110V AC 60Hz Accessories operational voltage. 2x 12V / 7Ah sealed lead acid gel batteries

Intelligent Security & Fire Ltd

Series. Access Power Controllers. Installation Guide

Conventional Fire Alarm System 2014 V1.2

DS7400Xi Addressable Control/ Communicator

MINERVA MX. 800 Series Ancillary Equipment

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

AL600ULADA. NAC Power Extender. Installation Guide

Addressable and Conventional Fire Protection

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Conventional Fire Alarm Control Panel

Booster Power Supply Manual

MR-2602 Two Zone Fire Alarm Control Panel

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

AND ARCHITECT SPECIFICATIONS

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Intelligent 2 & 4 Loop Fire Alarm Control Panels

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

AL800ULADA. NAC Power Extender. Installation Guide

Touch Screen 1 loop Addressable Fire Alarm Panel

AL600ULX Series. Power Supply/Charger. Installation Guide

June 10, 2002 DF C S2424

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

TrueAlert Addressable Notification Appliances

SECTION FIRE ALARM SYSTEMS

TrueAlert Addressable Notification

9822 Marine Fire and Detection Equipment. Cerberus PRO. Cerberus PRO. Marine Fire and Detection Equipment. Models FH-2071-UM, BP-62 and USCG-HPLATE

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

The complete conventional fire warning system

An introduction to... Sigma

FCPS-24F FIRE ALARM FIELD CHARGER/POWER SUPPLY FOR FIRE PROTECTION/SIGNALING SERVICE FCPS-24F/FCPS-24FE. Field Charger/Power Supply

INPUT / OUTPUT MINI MODULES

Model 17A00 Expansion Enclosure

5000 INSTALLATION GUIDE

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

RELEASE DEVICE CONTROLS

AND ARCHITECT SPECIFICATIONS

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

631RF Amp Power Supply

Application, Installation, Operation & Maintenance Manual

TrueAlarm Smoke Detectors

Multiple Input and Output Modules

Intelligent Single Loop Fire Alarm Control Panel

Transcription:

EXPERT IN SAFETY AND SECURITY TECHLOGY CONTENTS Conventional Fire Alarm System CK1004 Conventional Fire Alarm Control Panel CK1008 Conventional Fire Alarm Control Panel CK10016 Conventional Fire Alarm Control Panel CP1004 Conventional Fire Alarm Control Panel CP1008 Conventional Fire Alarm Control Panel CP1012 Conventional Fire Alarm Control Panel CP1016 Conventional Fire Alarm Control Panel RP1016 Repeater Panel CP1002M/S Conventional Fire Alarm Control Panel YT102 Conventional YT102C Conventional YT102M Mini Conventional WT105 Conventional WT105C Conventional WT105M Mini Conventional FT103 Conventional & SB106 Conventional SB116 Conventional Conventional Fire Alarm System Product Range Guide SG108 Conventional SG109 Conventional JL188-6 Conventional Alarm Bell JL188-8 Conventional Alarm Bell JL188-10 Conventional Alarm Bell Remote LED MD111 Testing Pole JY117 Date: 2012.08 2

INTRODUCTION We manufactures thousands of uniquely made smoke, heat and gas detectors annually, fulfilling a special role or function for each of our customers. We can custom-design detectors specifically for your applications. From product design to final manufacturing, we offer one-stop shopping for your residential and commercial detector needs. Any one of our existing product designs can also be modified to meet your specific requirements. In a "one-size-fits-all" world, We work harder to tailor our solutions to meet your needs. We are an ISO 9001:2000 certified manufacturer with an extended network of manufacturing subcontractors and suppliers located nearby. Our company currently owns a number of testing facilities, such as a UL-standard fire testing lab, a UL test box, a dust test chamber, an EN-54 testing tunnel, a buzzer sound-level trial station and a fluorescent-light interference testing site as well as EMC test equipment. We are also planning to expand our manufacturing and testing facilities in China to ensure that our products and manufacturing practices continue to meet the highest standards., heat, and gas detector manufacturing isn t an easy business to be in. Faced with the stiff competition from cheaply made, low-quality detectors, we remain committed to our customers with high quality products at the most reasonable prices. Our focus is to deliver meaningful value to clients that choose our brand over the competition through our commitment to quality. This year we are preparing to introduce our new line of advanced, feature-rich conventional and addressable detectors and panels at a competitive price. Introduction Conventional Fire Alarm Panel Conventional Fire Alarm Control Panel 4 Zone Fire Alarm Control Panel Model:CK1004 8 Zone Fire Alarm Control Panel Model:CK1008 16 Zone Fire Alarm Control Panel Model:CK1016 3 4 General The CK1000 Series Conventional Fire Alarm Control Panel is a 24 volt, four, eight, sixteen-zone, Class B, Conventional Fire Alarm Control Panel. Designed exclusively to meet the latest market requirements and future ULC codes, the highly costeffective CK1000 Series can be used in a variety of low- to midsized applications. Specifications AC POWER: 90 to 270VAC, 50 Hz, 3.0 amps. 2 Wire size: minimum 14 AWG (2.0 mm ) with 600-volt insulation. BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge. Maximum battery charger capacity: 18AH battery. Features Four to Sixteen Style B (Class B) Initiating Device Circuits (IDCs). All zones accept two-wire smoke detectors and any normallyopen contact devices. Zones 1-16 configured as general alarm zones. All circuits are power-limited and supervised, meeting the latest ULC requirements using fuseless technology. Two built-in, Style Y (Class B) Notification Appliance (Signal) Circuits (NACs). NACs may be programmed: Silenceable,Non-Silenceable, Auto- Silence 1.25 amps of NAC power. 3.00 amps of total system power. Alarm, Trouble and Supervisory, relay output. 24 volt operation. Resettable four-wire smoke detector power @ 500 ma. Nonresettable power @ 500 ma. Integral battery charger capable of charging up to 18 AH batteries (batteries over 4 AH require use of the external battery backbox, or ULC listed equivalent). Disable/Enable control per IDC. Reverse polarity protection.

Conventional Fire Alarm Control Panel 4 Zone Fire Alarm Control Panel Model:CP1004 The panel is a conventional fire detection control panel and indication control panel, designed to meet all the requirements of EN54-2&4 Microprocessor-based conventional fire alarm control panel One man test 4 Detection Zones Panel, 25 s per Zone 2 Relay outputs for fire condition Zones Fault LEDs indication, Zones Isolation LEDs indication Fault Relay Output, Auxiliary Output for 28Volts RS485 Port for repeater up to 1.2Km 2 sound Outputs Switched mode power supply 24V,3A with 2 battery chargers 12V End Of Line Status Detection, Short circuit /open circuit detection Open collector fault output 28V 50mA fused supply output on Fire Switched mode power supply 3A output Conventional Fire Alarm Control Panel 16 Zone Fire Alarm Control Panel Model:CP1016 The panel is a conventional fire detection control panel and indication control panel designed to meet all the requirements of EN54-2&4 Microprocessor-based conventional fire alarm control panel One man test 16 Detection Zones Panel, 25 s per Zone 2 Relay outputs for fire condition Zones Fault LEDs indication, Zones Isolation LEDs indication Fault Relay Output, Auxiliary Output for 28Volts RS485 Port for repeater up to 1.2Km 2 sound outputs Switched mode power supply 24V,3A with 2 battery chargers 12V Line Status Detection, Short circuit /open circuit detection Open collector fault output 28V 50mA fused supply output on Fire Switched mode power supply 3A output 8 Zone Fire Alarm Control Panel Model:CP1008 12 Zone Fire Alarm Control Panel Model:CP1012 The panel is a conventional fire detection control panel and indication control panel designed to meet all the requirements of EN54-2&4 Microprocessor-based conventional fire alarm control panel One man test 8 Detection Zones Panel, 25 s per Zone 2 Relay outputs for fire condition Zones Fault LEDs indication, Zones Isolation LEDs indication Fault Relay Output, Auxiliary Output for 28Volts RS485 Port for repeaters up to 1.2Km 2 sound outputs Switched mode power supply 24V,3A with 2 battery chargers 12V Line Status Detection, Short circuit /open circuit detection Open collector fault output 28V 50mA fused supply output on Fire Switched mode power supply 3A output The panel is a conventional fire detection control panel and indication control panel designed to meet all the requirements of EN54-2&4 Microprocessor-based conventional fire alarm control panel One man test 12 Detection Zones Panel, 25 s per Zone 2 Relay outputs for fire condition Zones Fault LEDs indication, Zones Isolation LEDs indication Fault Relay Output, Auxiliary Output for 28Volts RS485 Port for repeater up to 1.2Km 2 sound outputs Switched mode power supply 24V,3A with 2 battery chargers 12V Line Status Detection, Short circuit /open circuit detection Open collector fault output 28V 50mA fused supply output on Fire Switched mode power supply 3A output Alarm Conventional Fire Alarm Panel Conventional Fire Alarm Panel 16 Zone Repeater Panel Model:RP1016 2 Zone Fire Alarm Control Panel Model:CP1002M/S Master Panel Slave Panel 5 6 The repeater is a conventional fire alarm repeater panel and indication control panel designed to meet all the requirements of EN54-2&4 Microprocessor-based conventional fire alarm repeater panel 16 Detection Zones Repeater Panel Relay output for fire condition Zones Fault LEDs indication, Zones Fire LEDs indication RS485 Port for panel connection up to 1.2Km outputs 24 Volts needed from panel 4 wire connections to main panel: 2 for power, 2 for RS485 This repeater can be connected to any our fire alarm control panel from 4 Zone to 16 Zone Panels The mini 2 zone panel have Master panel and Slave panel. One Master panel can connect 31 Slave panel, and the Mater panel could show the fire and fault of all slave panel. The slave panel can only show itself fire and fault. Mini size as 108X143X40mm Master panel has 4 digital LED display to show slave number and status. 2 Detection Zones Panel, 25 s per Zone Fire 1 relay would be activated when one zone alarms. Fire 2 relay would be activated after 30 seconds delay when two zones alarm. 1 relay output for sound alarm 1 Fault relay output for fault condition Zones Fire and Fault LEDs indication Fire1, Fire2, relay outputs can be activated manually RS485 Port for repeater up to 1.2Km Up to 31 Slave panels can be connected to one Master panel Powered by outside DC22-26V power supply End Of Line Status Detection, Short circuit /open circuit detection

Conventional Prouducts Conventional Model:YT102 Conventional Prouducts Conventional Model:WT105 EN54 Approved Unique optical sensing chamber Drift compensation and smoothing algorithms EN54 Pending High precision electronic thermistor Conventional Model:YT102C Conventional Model:WT105C Unique optical sensing chamber Drift compensation and smoothing algorithms High precision electronic thermistor Mini Conventional Model:YT102M Diameter 64mm,Height 42mm Unique optical sensing chamber Drift compensation and smoothing algorithms Mini size: Diameter 64mm, Height 42mm(include base) Alarm Mini Conventional Model:WT105M Diameter 64mm,Height 42mm 7 8 High precision electronic thermistor Mini size: Diameter 64mm, Height 42mm(include base)

Conventional Prouducts Conventional Prouducts Conventional & Model:FT103 Unique optical sensing chamber and High precision electronic thermistor Drift compensation and smoothing algorithms Conventional Model:SG108 Long LED light life up to 100000 flahsed High sound level up to 100dB Conventional Model:SB106 Conventional Model:SG109 Can be reset by key 470 Ohm resistance Easy surface mounting Base included Long light life up to 40000 flahsed High sound level up to 100dB Conventional Model:SB116 Can be reset by key Push & Pull down operation Easy surface mounting Base included Alarm 9 10

Conventional Prouducts Conventional Alarm Bell Model:JL188-6 Conventional Prouducts Remote LED Model: MD111 Three module size of 6 inch High sound level up to 95dB Easy installation bracket included Steel material Red Color 8mm Big Size LED Outside two holes provide 83mm(USA) Inner two holes provide 59mm(Europe) Wiring Terminals provided on the PCB board Conventional Alarm Bell Model:JL188-8 Testing Pole Model: JY117 Three module size of 8 inch High sound level up to 95dB Easy installation bracket included Steel material detector testing instrument Max. Pole length is 5m Easy to use, all the parts in one case Conventional Alarm Bell Model:JL188-10 Three module size of 10 inch High sound level up to 95dB Easy installation bracket included Steel material Alarm 11 12

13 14 CONVENTIONAL FIRE ALARM SYSTEM ARCHITECTURE CONVENTIONAL FIRE ALARM SYSTEM ARCHITECTURE & & Max. 25 detectors in One Zone Max. 25 detectors in One Zone Remote LED Remote LED Remote LED Remote LED Remote LED Remote LED Remote LED Remote LED Remote LED Remote LED Bell Bell SOUND+ SOUND- 10K Bell Bell SOUND+ SOUND- 10K SOUND4 ( 16 ZONE) SOUND2 ( 8 ZONE) 6 ZONE 8 ZONE 4 SOUND 1 CK1004: 4 Zones, 1 output CK1008: 8 Zones, 2 output CK1016: 16 Zones, 4 output Max. 5 to 10 (1A@24VDC) er & Bell in One Output DC12V Output for security products Supervisory Input1 IR Intruder DC12V + DC12V - IR Intruder Magnetic Door Contact DC12V + Supervisory Input2 Resetable DC24V output Non-Resetable DC24V output Alarm Relay Output Fault Relay Output Supervisory Relay Output HOT NEUTRAL GROUND AC Power Input(90-270V) Magnetic Door Contact SOUND 1 (Alarm Zone1) 6 ZONE 8 ZONE 4 CP1004: 4 Zones, 2 output CP1008: 8 Zones, 2 output CP1012: 12 Zones, 2 output CP1016: 16 Zones, 2 output Max. 5 to 10 (1A@24VDC) er & Bell in One Output SOUND2 (Alarm Zone2) SOUND+ SOUND- Bell Max. 5 to 10 (1A@24VDC) er & Bell in One Output Auxiliary DC28V output RS485 communication bus HOT NEUTRAL GROUND Auxiliary1(Alarm1) Relay Output Auxiliary2(Alarm) Relay Output Fault Relay Output AC Power Input(90-270V) NC NC NC A B A B 10K.1 Repeater.2 Repeater Max..16 Repeater

CONVENTIONAL FIRE ALARM SYSTEM ARCHITECTURE & Max. 25 detectors in One Zone Remote LED Remote LED Remote LED Remote LED Remote LED Bell Bell SOUND+ SOUND- Line Diode 1N4007 Diode Max. 5 to 10 (1A@24VDC) er & Bell in One Output ZONE 2 SOUND OUTPUT No.1 Slave Panel Fire1 Alarm Relay Output A B Fire2 Alarm Relay Output Fault Relay Output DC24V Power RS485 Communication ZONE 2 SOUND OUTPUT Max No.31 Slave Panel Fire1 Alarm Relay Output AC Power Input(90-270V) Fire2 Alarm Relay Output Fault Relay Output DC24V Power A RS485 Communication B ZONE 2 Master Panel HOT NEUTRAL GROUND SOUND OUTPUT DC24V Power Supply DC12V battery Fire1 Alarm Relay Output DC24V DC12V battery Fire2 Alarm Relay Output Fault Relay Output EXPERT IN SAFETY AND SECURITY TECHLOGY Email: sales@vedard.com http://www.vedard.com 15 20