Conventional Fire Alarm Systems. ACCLAIM SERIES 10 Conventional Fire Alarm System ACCLAIM SERIES 10.

Similar documents
PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

HART XL High Sensitivity Smoke Detection

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Conventional Releasing Control Panel

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

System 800 Addressable Fire Detection & Alarm System

Specification/ Data Sheet

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

MINERVA MZX125 Digital Addressable Fire Detection System

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

HART XL High Sensitivity Smoke Detection

Conventional Fire Alarm System 2014 V1.2

intelligent fire alarm ID60series panels

TECHNICAL DATA OBSOLETE

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

ID50series. intelligent fire alarm panels

5000 INSTALLATION GUIDE

Hi, welcome to the topic on Fire Detection and Alarm Systems. This topic forms one of the critical knowledge areas for prospective fire safety

LF-4000 Series Conventional Fire Alarm Control Unit

CSP-204 CSP-208 CSP-104 CSP-108

Architect s Project Number of 12 Fire Alarm/Smoke Detection Systems District Master Specs 2013 Edition

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

Vigilant MX4428 Fire Alarm System

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

DS7400Xi Addressable Control/ Communicator

The EN54 Part 2, 4 and 13 Fire System

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

ID2000. intelligent fire alarm panel

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Consultant Specification AGILE Wireless Fire Detection System

AND ARCHITECT SPECIFICATIONS

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

ZP3 Operator & Maintenance Manual Version 1

The EN54 Part 2 & 4 Fire System

Electric Release Panel Wiring Tips

For Complete Fire and Gas Solutions

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Fire Alarm Control Panel CFP-16 OPERATION, INSTALLATION & PROGRAMMING MANUAL AUSTRALIAN EDITION. 26/05/2015 Rev D DOC

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

3.1 Introduction. 3.1 Introduction

MINERVA MX. 800 Series Ancillary Equipment

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

The new detector from Rafiki

FIRE ALARM SYSTEM FRCME AMS R2M SOM CZM DIMM. Serial. Annunciator. Printer ATG-EA ALK-V. Duct Detector SLC (DCP) Notification Alarm Equipment

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

Fire detection and alarm system Operating instructions

TABLE OF CONTENTS TABLE OF CONTENTS 1

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION FIRE ALARM SYSTEM

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

FS-1600 Fire Alarm Panel

Control Panel User Guide

Intelligent addressable fire alarm control panel

Commercial and Light Industrial Fire Alarm Control Panel

ALK-V PHOTOELECTRIC SMOKE SENSOR

FireNET Series - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

SALES SUPPORT DOCUMENT

ID3000 intelligent. fire alarm panel

AL600ULADA. NAC Power Extender. Installation Guide

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

CONTENTS Installation Precautions... 1 Chapter 1 Product Introduction... 2 Chapter 2 Technical Specifications... 3

ID3000 intelligent. fire alarm panel

intelligent solutions

MINERVA MZX125. Digital Addressable Fire Detection System

ADR Analog Addressable Fire Alarm Control Panel. Technical Manual. Control Panels. 3000En. En pdf

MR-2602 Two Zone Fire Alarm Control Panel

MX4428. Addressable Fire Alarm System. Features. Advantages & Options

Precept Marine Control Panel Application Guide

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Fire Alarm Control Panel. System Maintenance and Log Book

INTELLIGENT FIRE ALARM CONTROL PANEL

Across-the-Line SERIES MP300 Combined Manual and Automatic

BSR Addressable Fire Detection control panel. Installation operation manual

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

Soft Start Series MP700 Solid State, Reduced Voltage

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi 50 CONTROL PANEL

Transcription:

FIRE DETECTION : FIRE SUPPRESSION EMERGENCY VOICE COMMUNICATIONS SYSTEM INTEGRATION ACCLAIM SERIES 10 s

Building the system you need ACCLAIM SERIES 10 Fire Alarm Panel provides many flexible choices from basic conventional (non-addressable) panel to advance hard-wire addressable panel / systems. The basic conventional panels are available from 4 to 136 zones. The design is compact, attractive, user friendly and highly scalable. The panels are built with well proven solid state technology for long term cost effectiveness. Operation and maintenance of the panel are provided with general frontal indications and colour coded switches. The specific fault indications are mounted behind the front indications. It is able to work with most conventional fire alarm system (panels &devices) thus allowing stage by stage system upgrades and eliminate vendor lock-in problems. Applications Acclaim Series 10 Fire Alarm Panel is suitable for use in commercial complexes, schools, car parks, hospitals, hotels, warehouses, factories, data centres, condominiums etc. Benefits Compatibility : works with many other make of equipment, panels and devices Flexibility : wide range of auxiliary panels to meet each requirement. eg: Fire Extinguishing, Smoke Control, Pre-action etc. Wide range of detectors : works with all approved makes of conventional detectors

Low maintenance cost : system can be maintained and Reliability : system designed with proven solid state serviced by fire servicing contractors detection technology Alarm interlocks : general sounder silencing and system Local manufacturer support : system designed and sup- resetting or system with multiple panels ported locally by highly experienced support team Ease of use : one touch operation - easy to learn and Compliance : BS EN 54 Parts 2 & 4 :1998 and SS CP- reduces errors 10:2005 Diagnostic facilities : informative diagnostic LED indica- Approval : PSB Listed (4 to 136 zones) tors for easy identification and rectification of faults The Acclaim Series Hybrid Fire Alarm Panel provides many flexible, user friendly features that overcome the limitations found in today s conventional fire alarm systems. Its Performance, Reliability, Versatility and Unique Features greatly improve operational efficiency and productivity. Various upgrade options are available to enhance the fire alarm system such as: Auxiliary Status and Control Module provides addition indicators and control switches to be added to the panel for easy identification and control. The Alarm Verification Feature greatly reduces the disruption caused by unwanted false alarms. The LCD Display Unit automatically records the fire and alarm events with date and time, eliminating inaccurate or missing records due to human errors. Networking facility of the LCD Unit allows up to 32 panels to be networked and monitored from one centralized location. Zone (and device address, if hardwire addressable option is implemented) can be identified from the Main Alarm Panel thus reducing response time. Graphic User Interface guides duty staff to area in alarm in the shortest time possible. The Graphics User Interface also records events with date, time and operator information. The event storage capacity is only limited by the capacity of the hard disk of the PC. Various reports can be generated for post event analysis to help identify the cause and take preventive measures against future disruptions.

CONTROL PANELS & ACCESSORIES ACCLAIM SERIES 10 FIRE ALARM CONTROL PANEL ACCLAIM SERIES 10 Fire Alarm Panel provides many flexible choices from basic conventional (non-addressable) panel to advance hard-wire addressable panel / systems. The ACCLAIM SERIES 10 Fire Alarm Panel provides many flexible, user friendly features that overcome the limitations found in today s conventional fire alarm systems. Its Performance, Reliability, Versatility and Unique Features greatly improve operational efficiency and productivity. Various upgrade options are available to enhance the fire alarm system such as: Features: #1.Auxiliary Status and Control Module provides addition indicators and control switches to be added to the panel for easy identification and control

The Alarm Verification Feature greatly reduces the disruption caused by unwanted false alarms. The LCD Display Unit automatically records the fire and alarm events with date and time, eliminating inaccurate or missing records due to human errors. Networking facility of the LCD Unit allows up to 32 panels to be networked and monitored from one centralized location. Zone (and device address, if hardwire addressable option is implemented) can be identified from the Main Alarm Panel thus reducing response time. Graphic User Interface guides duty staff to area in alarm in the shortest time possible. The Graphics User Interface also records events with date, time and operator information. The event storage capacity is only limited by the capacity of the hard disk of the PC. Various reports can be generated for post event analysis to help ACCLAIM SERIES 10 FIRE EXTINGUSHING CONTROL PANEL Acclaim Advance Fire Extinguishing Panel provides many flexible choices from basic conventional (non-addressable) panel to advance hard-wire addressable panel / systems. The basic conventional panels are available from 1 to 136 zones. The designis compact, attractive, user friendly and highly scalable. The panels are built with well proven solid state technology for long term cost effectiveness. operation and maintenance of the panel are provided with general frontal indications and color coded switches. The specific fault indications are mounted behind the front indications. It is able to work with most water / gas extinguishing system (FM200, Inert gas, CO2 & water mist etc.) and comes complete with Cross Zone Detection, Voting Logic Circuit (option), two digit countdown display and multiple zones with individual or common firing circuit. Features: Ease of use : Simple one touch operation, easy to learn and reduces errors Alarm interlocks : General sounder silencing and system resetting for system with multiple zone panel Facilities : Two digit timer countdown display, remote / local manual release & abort functions, 1st & 2nd alarm auxiliary output etc. Solid state detection technology Local manufacturer support : System designed and supported locally by highly experienced support team Compliance : BS EN 54 Parts 2 & 4 :1998, SS CP-10:2005 Approval : PSB approved (1 to 136 zones)

AS10-ICM8-1 8 WAY INDICATOR/CONTROL MODULE The AS10-ICM8-1, 8 way Indicators / Control Module is utilized in the range of Fire / Extinguishing Control Panel as an extended function for monitoring of remote status and controlling of additional auxiliary outputs. The V5-ICM8- is integrated with circuitry for the buzzer resound function upon monitoring status activation and the reminding buzzer function upon auxiliary control switch activation. AS10-ACM-1: 8 WAY CONTROL MODULE The AS10-ACM-1 8 way Control Module is utilized in the range of Fire / Extinguishing Control Panel as an extended function for controlling of additional auxiliary output. The AS10-ACM-1 is integrated with circuitry for the reminding buzzer function upon auxiliary control switch activation. Each auxiliary control switch can be operated either disable function as standard or manual start/stop function as option. Individual switch LED indicator is provided to notify the activation of the switch status. AS10-ATM-1: 8 WAY AUXILARY TERMINATION MODULE The AS10-ATM-1 is an 8 way Auxiliary Termination Module. It is utilized as an extension of Auxiliary Outputs to control Auxiliary Services; Lift / Fan / Sliding Door, etc. and alarm signal interfacing to Building Management System (BMS). The AS10-ATM-1 is provided with field selectable jumpers to select required type of output signal individually. It is usually connected to front 8 ways Auxiliary Control Module ACM for disable function or manual start/stop function respectively. AS10-SIM-1 :8 WAY STATUS INDICATOR MODULE The AS10-SIM-1 8 way Status Indicators Module is utilized in the range of Fire / Extinguishing Control Panel as an extended function for monitoring of remote status. The AS10-SIM-1 is integrated with circuitry for the buzzer resound function upon monitoring status activation. The V5-SIM-1 module is utilized as a front module and it is usually connected to the Status Termination Module AS10-STM-1 / Selectable Status Termination Module V5-SSTM-1.Ribbon connectors are provided for connection to the other system modules, this facilitates ease for installing and replacing of module. AS10-SSTM-1 : 8 WAY SELECTABLE STATUS TERMINATION MODULE The AS10-SSTM-1 is an 8 way Selectable Status Termination Module. It is utilized as an extension module to remote monitor the status such as Sprinkler Water Tank High Level / Low Level status, Pump Run / Stop status, Damper Open / Close status, Smoke Curtain Up / Down status etc. The AS10-SSTM-1 is provided with field selectable jumpers to select required type of input signal individually, Normally Open/ Normal Close signal. It is usually connected to front 8 ways Status Indicators Module SIM to indicate the status of remote monitoring status activation signal.

AS10-ASM2-1 :ALARM/AUXILAURY SUPERVISORY MODULE ACCLAIM SERIES 10 The AS10-ASM2-1 Alarm / Auxiliary Supervisory Module is utilized as an extension of alarm bell output or is employed as additional auxiliary output supervision when required. The AS10-ASM2-1 is provided with 2 alarm outputs, integrated with line open / short supervision circuitry complete with specific fault indicators provided for each output. EOLR (6.8K Ohm) resistor is required to be terminated at last device and polarized bells/auxiliary equipment shall be used for line open/short fault monitoring. Line Te-off s connection is not permitted. AS10-RTM-1 :16 WAY REPEATER TERMINATION MODULE The AS10-RTM-1 is a 16 way Repeater Signal Termination Module. It is utilized in the Fire Alarm Control Panels (FAP) to repeat Zone / Status alarm signal to Repeater panel. Transient surge voltage and over voltage protection circuitry is also incorporated for each repeat alarm signal. It is usually connected to front Zone Detection Module ZDM / Status Indicators Module SIM to repeat Zone / Status alarm signal to Repeater panel. AS10-LIM-1 24 WAY LCD INTERFACING MODULE The AS10-LIM-1 is a 24 way LCD Interfacing Module, to communicate with LCD Event Logging Module LLM for Alarm event signal. It is utilized as an extension module in Fire Alarm Panel (FAP) and Extinguishing Control Panel (ECP). It can also be utilized as Detector Address Point Termination Module in Hardwire Addressable System. The AS10-LIM-1 (Main) is applied for first 24 alarm signal interfacing and the V5-LIM-1 (Sub) is applied as an extension for subsequence module after first 24 alarm signal interfacing. AS10-LLM-1: LCD EVENT LOGGING MODULE LCD Event Logging Module (LLM) is utilized in the Fire / Extinguishing Control Panel as an add on feature to display and record the activated alarm zone information complete with date and time. LLM is integrated with non-volatile memory (EEPROM) to store and record the activated alarm zone event up to 999, it will not be lost even the system total power failure. LLM is also incorporated with backup battery for real time clock, it will be continuous running during the system total power failure. AS10-PSM-2: POWER SUPPLY MODULE The AS10-PSM-2 is a Power Supply Module work together with external step down transformer to supply power to the system. Self diagnosis function circuitry is incorporated to monitor AC Mains failure, supply output low/high voltage fault, battery disconnect fault, battery low/high voltage fault and charger/battery fuse blown fault complete with specific fault indicators provided. The V5-PSM-2 is integrated with voltage regulator circuit and protection circuit for over current, mains surge/over voltage, battery short and battery reverse connection.

AS10 LOOP DEVICES SLV-E(J) PHOTO ELECTRIC SMOKE DETECTOR Hochiki's new Photoelectric Detector incorporates a redesigned smoke chamber with 'Flat 'Response Technology 'enabling it to be equally sensitive to a wider range of combustible materials,thus removing the need for Ionisation Detectors in the majority of applications. New Chamber designed to reduce unwanted alarms and flat response smoke chamber consists of an LED and photo diode arrangement. The chamber is easily removed or replaced for cleaning and utilizes an unique baffle design which allows smoke to enter chamber whilst keep out ambient light. SLV-24N PHOTOELECTRIC SMOKE DETECTOR The SLV-24N can be used in all areas where Photoelectric Smoke Detectors are required. The patented smoke chamber makes the SLV-24N well suited for fires ranging from smouldering to flaming fires. NS-4 Series, NS-6 Series, HSC-4R or HSC-xxx R Style bases may be used with the SLV-24N. Current interchangeable/compatible devices are the SIJ-24 ionization detector, the SLR-24H photoelectric detector with heat sensor, and the DCD-135/190 heat detectors. DFJ-90E : Fixed-Temperature Heat Detector The DFJ Fixed Temperature Heat Detector is suited for installation where high heat output fires are expected or in areas where ambient condition would not allow the use of other detection methods (e.g. the presence of steam or cooking fumes such as in a boiler room or kitchen). Consideration should be given to the maximum normal operating temperature before deciding on the most appropriate DFJ detector for the application.

DFG-60E CONVENTIONAL WEATHER PROOF HEAT DETECTOR Model DFG-60E is a 60 C Fixed Temperature Waterproof Heat Detector, the detector uses a bi-metallic strip to sense temperature change, therefore consuming minimal standby current and providing high reliability. The DFG-60E is particularly suited to environments, which are exposed to high levels of condensation or are hosed down. The detector has a wide operating margin allowing it to respond to both slow and fast increases in temperature; it can also sense temperature KAC MCP1A: INDOOR CALL POINT Installation time and ultimately cost, are of paramount importance to any fire or security installer. The MCP range directly reflects this need by providing a unique plug and play concept designed specifically to reduce installation time. All new MCP products utilize a special terminal block, where all initial installation cabling is terminated. This terminal block is then simply connected to the back of the MCP. Simple, but effective, with no retermination required and no time wasted. KAC WCP1A-R470SG OUTDOOR CALL POINT The outdoor WCP is an IP67 sealed manual call point product. The enhanced environmental protection allows the unit to be installed in many external environments where water and dirt are likely to be present, making it a true waterproof and outdoor product. Installation time and ultimately cost, are of paramount importance to any fire or security installer. The WCP range directly reflects this need by providing a unique plug and play concept designed specifically to reduce installation time. All new WCP products utilise a special terminal block, where all initial installation cabling is terminated. MBA-6 KOBISHI ALARM BELL An aluminium die cast housing covers the operating part of this bell. Therefore the bell is suitable for both indoor and outdoor applications. A high quality micro-motor serves as the operating part. It provides reliable performance and an extremely long lifetime is assured. The micro-motor operates with a low starting voltage and very low current consumption. Use with Model: BBX-4 back box for a complete weatherproof application SYS-STR-FIRE RED BODY STROBE WITH CLEAN LEN & FIRE The System Sensor line of notification devices offers the most flexible and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red housing, universal fire symbol and a ceiling mount accessory available these devices can meet virtually any application. They also mount to a wide variety of back box sizes to offer the most flexibility in installation. This line of devices features a wide variety of features that simplifies installations. The mounting plate allows the devices to be compatible with a wide range of back box sizes. Settings for the strobe and horn are done using easy to set rotary switches on the back of the device.

s Information contained in this data sheet is up-to-date and correct as at the date of issue. As ACCLAIM cannot control or anticipate the conditions under which this product may be used, each user should review the information in specific context of the planned use. To the maximum extent permitted by law, ACCLAIM will not be responsible for damages of any nature resulting from the use or reliance upon the information contained in this data sheet. No express or implied warranties are given other than those implies mandatory by law. 171 Kaki Bukit Avenue 1 Shun Li Industrial Park Singapore 416020 Tel : +65 62990798 Fax : +65 62993735