laboratory & sterilization technology

Similar documents
NC SERIES. Horizontal Steam Sterilizers

NC SERIES. Bench Top Steam Sterilizers

NC 100. Vertical Steam Sterilizer

OT SERIES. Bench Top Steam Sterilizers

laboratory & sterilization technology

OT 300/430/570/710/850 STEAM STERILIZERS

OT 300/430/570 STEAM STERILIZERS

FN 032/055/120 DRY HEAT STERILIZERS / OVENS FN 300/400/500 DRY HEAT STERILIZERS / OVENS KD 200/400/700 OVENS EV 018 VACUUM OVEN

laboratory & sterilization technology

EC 160 CO 2. Incubator

AZTECA A LITRE STERILISER

EN 025/055/120 INCUBATORS EN 400/500 INCUBATORS ES 120/252 COOLED INCUBATORS. E N S e r i e s. E N S e r i e s. E S S e r i e s

FN 032/055/120 DRY HEAT STERILIZERS / OVENS FN 300/400/500 KD 200/400/700 OVENS EV 018 VACUUM OVEN E V K D S E R I E S F N S E R I E S

STEAM STERILIZER SERIE S1000 (RBE)

Professional sterilization systems

TABLE TOP - STEAM STERILIZER Dental & Hospital Application

LTE Scientific Ltd. Touchclave-PL Porous Load Steam Sterilizer

STERIDENT, STERIMAT, STERIMAT PLUS

AUTOCLAVE STEAM STERILIZERS (BENCH TOP)

Advance Autoclave. Designed to give you more for your money with a high capacity for faster throughput: More features and benefits...

N-Wissen GmbH. Top Loading Autoclaves (95, 120, 135 L) Available top loading models: The Top Loading Autoclave range features:

Large Steam Sterilizers for Life Sciences

TECHNICAL SPECIFICATION 44 and 55 Compact Sterilizer Series

CENTRAL STERILISATION. Innovative, hardworking Sterilisation & Infection Control products perfect for your Central Sterile Supply Department

Kronos Class B Sterilizer

VS LD series vertical steam sterilizers

CLINOCLAV steam sterilizer AH-21 L

Laboratory Line. Vertical and Bench-Top Life Science Autoclaves

Tabletop 2340 EA-D Class S Autoclave 19 Litres

Advance Autoclave. Designed to give you more for your money with a high capacity for faster throughput: More features and benefits...

PRE AND POST VACUUM CLASS B AUTOCLAVE

A WORLD OF QUALITY, SAFETY AND HYGIENE STERILCLAVE. 18 litres-bhd/b/s

Open the Door to Increased Productivity and Cost Efficiency

Midmark Sterilizers. Connect. Flow. Save.

MST sterilizer overview

STERILAB Steam sterilizer with gravitation de-aeration (without vacuum pump) for laboratory purposes.

Getinge Quadro Tabletop Sterilizer Product Specification

Podiaclave+ The PodiaClave+ is specifically designed for the clinic based podiatrists and chiropodists.

Washer disinfectors Small - Medium range

creating the right atmosphere NEW SERIES Galaxy Plus 170 litre CO 2 Incubators Advanced design for optimum results

B+N 18/23L LED. Ritter CleanTec with LED Display BB 18 + BB 23. Sterilizable Products:

Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers

Your Health, our Technology AWD655. Instrument Washer Disinfector

DENTAL TABLE TOP STERILIZER SERIES S CLASS MODEL : MO-MOST-T24/45/80.

ESTEEM AUTOCLAVE SLIDING SINGLE DOOR:-

Protection. in un unica autoclave E10

Setting The Standards For A Safer Future

cgmp STEAM STERILIZERS

Steam sterilizer AHS-75-DRY

FORMALDEHYDE LOW TEMPERATURE STERILIZER Hospital & Laboratory Application

Laboratory thermostatic chambers

LABOKLAV. Autoclaves Made in Germany

The Premium-Evolution series. The new benchmark for steam sterilizers

SST2200 & Stainless Steel Steam Sterilizers SST1700 &

Introducing the latest model in Prestige Medical s first-class range of Advance autoclaves - Advance Pro.

TECHNICAL SPECIFICATIONS FOR PLUSHER WDS 18 SERIES INSTRUMENT WASHER DISINFECTORS

TECHNICAL SPECIFICATIONS FOR PLUSHER WDS 12 SERIES INSTRUMENT WASHER DISINFECTORS

Operations Manual. Part Number: For Research Use Only

Sterilizers N e w G e n e r a t i o n

TECHNICAL SPECIFICATIONS FOR PLUSHER WDC 8 SERIES INSTRUMENT WASHER DISINFECTORS

Bluestone Industrial & Trading Limited

EZPlus Fully Automatic Sterilizers

Kayla Africa Suppliers & Distributors Cc Address: Unit C9, Wadeville Business Park, Cnr Steenbras & Shad Roads, Wadeville, Germiston,

Your Health, our Technology AWD655. Instruments Washer Disinfector

REFRIGERATOR M E D I C A L.

LTE Scientific Ltd. Touchclave-R. The dynamic new range of cylindrical-section autoclaves from LTE Scientific

A Safe, Stable Environment for Culturing Cells. Easy Set-Up Control and Monitoring. Sophisticated Alarm, Security and Back-Up Systems

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

Midmark DentiSure sterilisers

CELITRON COMPACT SOLUTION FOR BIOHAZARD WASTE DISPOSAL Integrated Sterilizer and Shredder (ISS)

Drying and heating chambers. Series ED FD FED FP M

STERILIZER STEAM - GLOBO 6412 INNOVATING TRADITION

FITOCLIMA 600 & 1200 PHARMA

Control Operating Costs. Gain Process Efficiency.

GE RCD Series Compact pot and utensil washers

Veterinary Autoclave

Sunrise the beginning of a brand new day

highest performance on smallest footprint WD 200: Single-chamber washer-disinfector in compliance with EN ISO 15883

Laboratory refrigerators

VHP ARD BIODECONTAMINATION SYSTEM

TETHYS H10 PLUS. As a result of constant technological updating, the technical data may be subject to change without prior notice.

Analytical Technologies Autoclave (3420BT)

Drying ovens, incubators, cooled incubators

GETINGE GEW 2100LS CAGE AND RACK WASHER PREVENTING CONTAMINATION IN ANIMAL CARE

Operation and Maintenance Manual

DEKO Washer-disinfector WASHROOM SYSTEMS

Matachana Low Temperature Steam and Formaldehyde 130 LF Sterilizer

FITOCLIMA 600 & 1200 STABILITY

FOB THIRD-GENERATION BENCH-TOP SATURATED-STEAM STERILIZERS

FITOCLIMA 600 & 1200 STABILITY

getinge quadro tabletop SteriLiZer

HIGH SPIN WASHING MACHINES

WASHER DISINFECTORS ISO ISO ISO 9001

Multi-Lab REFRIGERATORS Frigidere medicale

Large Steam Sterilizers. CELITRON COMPACT SOLUTION FOR BIOHAZARD WASTE DISPOSAL Integrated Sterilizer and Shredder (ISS)

labcoater TypE «lte-s»

Washer disinfectors. > Small - Medium range. devoted to hygiene. For the Environmentally conscious

Drying and heating chambers

Getinge HS33. Article List. General Specification

Products, Process, Protection

Transcription:

laboratory & sterilization technology

NC 23B - NC 23S/32S BENCH TOP STEAM STERILIZERS Small steam sterilizers are widely used for the sterilization of the products used for medical purposes, e.g in general medical practices, dentistry, facilities for personel hygiene and beauty care and also veterinary practices. EN 13060, European Standard for small steam sterilizers, specifies the general requirements for small steam sterilizers and test methods for specified sterilizer loads. The sterilization of the loads are classified in three classes of cycles. B, N and S. The vast experience of Nuve for the manufacturing of steam sterilizers created steam sterilizers which totally satisfy all requirements of EN 13060 for B and S type sterilization cycles with extra technical advantages : NC 23B - NC 23/32S STERILIZATION LOADS Three different models for different sterilization loads: NC 23B: All wrapped or unwrapped, solid, hollow load products Type A and porous products. NC 23S/32S: Unwrapped solid products, porous products, small porous items, hollow load products Type B, single wrapped products, multiple layer wrapped products.

VACUUM SYSTEM Maintenance free powerful vacuum pump Condensation of the steam by condenser to increase the efficiency of the vacuum pump Fractioned pre-vacuum system to eliminate air bubbles inside the material for successful steam penetration Perfect drying by means of post vacuum system CHAMBER DESIGN Chamber made of stainless steel Seamless chamber for 23 and 32 liter models Reversible shelf carrier suitable for standard shelves and sterilization cassettes RELIABLE AND POWERFUL CONTROL SYSTEM: N-Smart Maximum information with highly visible 4.3 colourful LCD display Four context-sensitive function keys for versatile & easy use Password protected menu to secure run parameters and data With 5 language options: Turkish, English, French, Russian, Spanish Icons to make the operations easier for immediate understanding

EASY STERILIZATION Pre - set programs which guarantee safe sterilization of treated material Universal 134 C 4 minutes B,S Quick, unwrapped 134 C 4 minutes B,S Sensitive material 121 C 20 minutes B,S Prion 134 C 20 minutes B,S Wrapped 134 C 4 minutes S Flash 134 C 4 minutes B Two programmable free programs : Temperature : 121 C or 134 C Sterilization time: 1-20 minutes No. of pre vacuum : 1-4 B,S models Drying time : 0-30 minutes B,S models Drying program with programmable time 1-30 min. Pre - heating TEST PROGRAMS Vacuum leakage test and Bowie & Dick/Helix test programs for NC 23B Vacuum leakage test and Bowie & Dick test programs for NC 23S/32S FULL TRACEABILITY AND REMOTE ACCESS Operating parameters can be tracked graphically against time Massive data storage with internal memory which stores the records of last 500 cycles detailed and 29.500 cycles as summary Memory for the last 100 failures USB port to record the operated cycles in the memory to a memory stick PC connection through USB / RS 232 port Ethernet port for remote access through internet by means of optional NüveCloser software NüveCloser allows to access operating parameters, memory, failure history and other technical parameters Optional panel type printer to keep the records of the sterilization cycle

PROCESS EVALUATION AND SELF DIAGNOSTIC SYSTEM Compare the preset values with operating parameters using the process evaluation system When the operating parameters do not match the preset values, the sterilization cycle is cancelled and the user is warned Comprehensive self-diagnostic system for 19 possible failures such as power failure, heater failure, low water level, high pressure and temperature, sensor failure... SAFETY OVER STANDARDS Password protected control system, service and calibration menu Lid safety system Colour of the display changes to red in case of any alarm condition along with an audible alarm Reminder for gasket and filter replacement Remote failure diagnostic by means of NüveCloser software Sending e-mails up to five e-mail addresses with the details of failure Optional AlerText SMS alarm system for ultimate security Safety valve against over pressure HEPA filter at air intake line Chamber manufactured according to PED 2014/68 EC Validation port as standard Phone Alarm AlerText TM

NC 40M/90M LABORATORY STEAM STERILIZERS NC 40M / NC 90M laboratory steam sterilizers are specially designed for the steam sterilization of liquid and culture media and also convenient for the sterilization of any labware such as glass and plastics and unpacked solid materials in the laboratories of hospitals, universities and pharmaceutical, food, beverage, dairy and biotechnology industries. STANDARD FEATURES FOR LIQUID STERILIZATION Flexible temperature sensor to measure the temperature of the liquid load directly as the time required to reach the sterilization temperature of liquid is longer compared to solid loads. Cooling function with ambient air ventilation over the chamber that decreases the cooling time of liquid loads to the one third of time spent by conventional systems. Condensation of steam at the end of the cycle by means of air ventilated cooling system to prevent a sudden drop in the chamber pressure which causes re-boiling. WELL PRESERVED SENSITIVE MATERIALS Second temperature sensor active for solid load sterilization. Controlled steam discharge by fractionated exhaust. Programmable exhaust rate against sudden temperature and pressure drop to preserve sensitive materials such as glass.

RELIABLE AND POWERFUL CONTROL SYSTEM: N-Smart Maximum information with highly visible 4,3 colourful LCD display Four context-sensitive function keys for versatile & easy use Password protected menu to secure run parameters and data With 5 Language options: Turkish, English, French, Russian, Spanish Icons to make the operations easier for immediate understanding EASY STERILIZATION Five pre-set programs which guarantee safe sterilization of the treated material. Liquid 121 C 15 minutes Liquid 121 C 20 minutes Solid 121 C 20 minutes Solid 134 C 20 minutes Solid Quick 134 C 4 minutes Two free programs for liquid and solid and a special program for melting purposes which the user can program easily. Delayed start function with real time which allows the users to get their samples sterilized on time as they arrive to the laboratory. Programmable pre-heating.

FULL TRACEABILITY AND REMOTE ACCESS Operating parameters can be tracked graphically against time Massive data storage with internal memory which stores the records of last 500 cycles detailed and 29.500 cycles as summary Memory for the last 100 failures USB port to record the operated cycles in the memory to a memory stick Possibility of PC Connection through USB / RS 232 port Ethernet port for remote access through internet by means of optional NüveCloser software NuveCloser allows access to operating parameters, memory,failure history and other technical parameters Optional panel type printer to keep the records of the sterilization cycle

SAFETY OVER STANDARDS Password protected control system, service and calibration menu Lid safety system - Lid cannot be opened when the chamber is pressurized - Program cannot be operated if the lid is open - Lid can be opened when the liquid temperature is below 80 C after liquid sterilization - Lid can be opened when the chamber temperature is below 90 C after solid sterilization Comprehensive self-diagnostic system to provide the information regarding possible system malfunction. The self-diagnostic system warns user in case of: - Broken temperature sensors - Over temperature - Heater failure - Low temperature - Overpressure - Exhaust tank failure - Lack of water - High preheating temperature Colour of the display changes to red in case of any alarm condition along with an audible alarm Remote failure diagnostic by means of NüveCloser software Sending e-mails up to five e-mail addresses with the details of failure Optional AlerText SMS alarm system for ultimate security Safety valve against over pressure Manometer to follow the chamber pressure Chamber manufactured according to PED 2014/68 EC Validation port as standard Phone Alarm AlerText TM

NC 100 VERTICAL STEAM STERILIZER NC 100 Vertical Steam Sterilizer is designed for the sterilization of textile, wrapped or packed materials, glass and liquid in operating theatres and laboratories of hospitals; dentistry; biology, veterinary and agricultural departments of universities; microbiology and quality control laboratories of industry such as food. VERSATILE OPERATING SYSTEM Integrated steam generator for fast production of steam Maintenance-free diaphragm type powerful vacuum pump Fractionated pre-vacuum to eliminate all air bubbles and achieve successful steam penetration Fractionated post-vacuum for efficient drying of the samples Sterilization quality matching the needs of EN 285 European Standard for Large Steam Sterilizers Pre-heated chamber to eliminate condensation on the chamber walls and to speed up the heating of the samples

RELIABLE AND POWERFUL CONTROL SYSTEM: N-Smart Maximum information with highly visible 4,3 colourful LCD display Four context-sensitive function keys for versatile & easy use Password protected menu to secure run parameters and data With 5 language options: Turkish, English, French, Russian, Spanish Icons to make the operations easier for immediate understanding EASY STERILIZATION Five pre-set programs which guarantee safe sterilization of the treated material Universal 134 C 4 minutes Solid rubber material 134 C 10 minutes Prion 134 C 20 minutes Quick, unwrapped 134 C 4 minutes Sensitive material 121 C 20 minutes Ten programmable free programs: Temperature : 105 C - 136 C Sterilization time : 1-99 minutes No. of pre vacuum : 1 4 Drying time : 0-30 minutes Two special programs for liquid sterilization and drying Programmable pre-heating

TEST PROGRAMS Vacuum leakage test and Bowie & Dick test FULL TRACEABILITY AND REMOTE ACCESS Operating parameters can be tracked graphically against time Massive data storage with internal memory which stores the records of last 500 cycles detailed and 29,500 cycles as summary Memory for the last 100 failures USB port to record the operated cycles in the memory to a memory stick Possibility of PC connection through USB / RS 232 port Ethernet port for remote access through internet by means of optional NüveCloser software NüveCloser allows to access operating parameters, memory,failure history and other technical parameters Optional panel type printer to keep the records of the sterilization cycle

PROCESS EVALUATION AND SELF DIAGNOSTIC SYSTEM Compare the preset values with operating parameters using the process evaluation system When the operating parameters do not match the preset values, the sterilization cycle is cancelled and the user is warned Comprehensive self-diagnostic system for 19 possible failures such as power failure, heater failure, low water level, high pressure and temperature, sensor failure... SAFETY OVER STANDARDS Password protected control system, service and calibration menu Lid safety system Colour of the display changes to red in case of any alarm condition along with an audible alarm Reminder for gasket and filter replacement Remote failure diagnostic by means of NüveCloser software Sending e-mails up to five e-mail addresses with the details of failure Optional AlerText SMS alarm system for ultimate security Safety valve against over pressure HEPA filter at air intake line Chamber and generator manufactured according to PED 2014/68 EC Validation port as standard Phone Alarm AlerText TM

NC 150/150D HORIZONTAL STEAM STERILIZERS NC 150/150D Horizontal Steam Sterilizer is designed the sterilization of textile, wrapped or packed materials, glass and liquid in operating theatres and laboratories of hospitals; dentistry; biology, veterinary and agriculture departments of universities; microbiology and quality control laboratories of industry such as food. With its double doors, NC 150D is ideal solution for the small sterilization centers which have divived as clean and dirty areas. VERSATILE OPERATING SYSTEM Integrated steam generator for fast production of steam Maintenance-free diaphragm type powerful vacuum pump Fractionated pre-vacuum to eliminate all air bubbles and achieve successful steam penetration Fractionated post-vacuum for efficient drying of the samples Air driven gasket with internal compressor Pressure measurement of gasket Connected directly to water supply through siliphos filter supplied. Delivered with shelf carrier and shelves Sterilization quality matching the needs of EN 285 European Standard for Large Steam Sterilizers Pre-heated chamber to eliminate condensation on the chamber walls and speed up the heating of the samples

RELIABLE AND POWERFUL CONTROL SYSTEM: N-Smart Maximum information with highly visible 4,3 colourful LCD display Four context-sensitive function keys for versatile & easy to use Password protected menu to secure run parameters and data Easy to understand 5 Languages: Turkish, English, French, Russian, Spanish Icons make the operations easier for immediate understanding EASY STERILIZATION Seven pre-set programs which guarantee safe sterilization of the treated material Resistant textile 136 C 20 minutes Wrapped porous 134 C 20 minutes Prion 134 C 20 minutes Quick, unwrapped 134 C 4 minutes Resistant rubber 121 C 20 minutes Sensitive material 121 C 20 minutes Gravity 121 C 20 minutes Programmable ten free programs: Temperature : 105 C - 136 C Sterilization time: 1-99 minutes No. of pre vacuum: 1 4 Drying time: 1-30 minutes Two special programs for liquid sterilization and drying Programmable pre-heating

TEST PROGRAMS Vacuum leakage test and Bowie & Dick test FULL TRACEABILITY AND REMOTE ACCESS Operating parameters can be tracked graphically against time Massive data storage with internal memory which stores the records of last 500 cycles detailed and 29.500 cycles as summary Memory for the last 100 failures USB port to record the operated cycles in the memory to a memory stick Possibility of printer connection through USB / RS 232 port for printing the cycles in the memory or connection to PC Ethernet port for remote access through internet by means of optional NüveCloser software NüveCloser allows to access operating parameters, memory,failure history and other technical parameters Panel type printer to keep the records of the sterilization cycle

PROCESS EVALUATION AND SELF DIAGNOSTIC SYSTEM Compare the preset values with operating parameters using the process evaluation system When the operating parameters do not match the preset values, the sterilization cycle is cancelled and the user is warned Comprehensive self-diagnostic system for 19 possible failures such as power failure, heater failure, low water level, high pressure and temperature, sensor failure SAFETY OVER STANDARDS Password protected control system, service and calibration menu Lid safety system Colour of the display changes to red in case of any alarm condition along with an audible alarm Reminder for gasket and filter replacement Remote failure diagnostic by means of NüveCloser software Sending e-mails up to five e-mail addresses with the details of failure Optional AlerText SMS alarm system for ultimate security Safety valve against over pressure HEPA filter at air intake line Certified chamber and generator according to PED 2014/68 Validation port as standard Phone Alarm AlerText TM

NC 300/430/570/710 HORIZONTAL STEAM STERILIZERS Our continuous investments in research and development have enabled us to develop our horizontal steam sterilizer series with innovative Air Cooling System The reliability, performance, ease of use and safety features of NC Series Horizontal Steam Sterilizers optimize the steam sterilization process and they are convenient for steam sterilizing packed or unpacked surgical and dental instruments, operation linen, glass, plastic, rubber and silicon materials, infusion liquids, microbiological cultures and medical waste. Double door versions are ideal for central sterilization centres having dirty and clean sides. RUGGED AND RELIABLE DESIGN The chamber, steam jacket, door and the steam generator made of 316L stainless steel and they are tested according to EN285, European Standard for Large Steam Sterilizers and PED 2014/68/EC Pressure Equipment Directive. Efficient insulation for the chamber, door and steam generator Pneumatically controlled sliding door Steam driven chamber gasket made of silicon as single piece Carefully chosen high quality valves, sensors and transmitters for a problem free and safe operation Pneumatically controlled valves used in the steam lines which have longer service life than electrically operated valves. Steam jacket surrounding the chamber for homogenous heating and preventing condensation on the loads.

POWERFUL AND EFFICIENT VACUUM High capacity and silent water ring pump which has low energy and water consumption Pre-vacuum by pulsating steam and vacuum in sequential pulses Post-vacuum for efficient drying INNOVATIVE AIR-COOLING SYSTEM TO SAVE NATURAL SOURCES Steam Sterilizers have high operational cost. Besides the power consumption, high amount of water is used to produce steam and to condense and cool down the steam at the end of the cycle. Steam Sterilizer with a chamber capacity of 500 litres, has approximately 500 litres water consumption per cycle in a classic system. Different than the classical method to condense and cool down the steam, an innovative system is used in NC series Steam Sterilizers: AIR-COOLING. The steam is condensed and cooled down while passing through a condenser which is cooled by ambient air. Thus, there is no water consumption to condense and cool down the steam for NC Series Horizontal Steam Sterilizers

EASY STERILIZATION RELIABLE AND POWERFUL CONTROL SYSTEM Steamart Microprocessor control system with 800x480 pixels 7 colourful touch screen Icons making the operations easier for immediate understanding Displayed parameters during sterilization cycle : - Chamber temperature and pressure - Jacket temperature and pressure - Generator temperature and pressure - Gasket pressure - Name of operating program - Program phase - Graphic of temperature and pressure - Date and Time - Number of operated programs in the same day - Total number of operated programs Seven pre-set programs which guarantee safe sterilization of the treated material Program Name Temperature Sterilization Time Wrapped porous materials 134 C 7 minutes Sensitive materials 121 C 20 minutes Rubber materials 125 C 20 minutes Heavy wrapped materials 134 C 7 minutes Unwrapped materials 134 C 4 minutes Prion 134 C 20 minutes Gravity 121 C 25 minutes 50 custom made programs : Programmable parameters for custom made programs : Sterilization Temperature: 121 C 125 C 134 C 136 C Sterilization Time : 01-60 minutes No. of pre-vacuum: 1-4 Drying time: 0-60 minutes Special liquid program at 121 C with 1-60 minutes programmable sterilization time TEST PROGRAMS Vacuum leakage and Bowie & Dick test programs

FULL TRACEABILITY AND REMOTE ACCESS Operating parameters can be tracked graphically against time Internal memory which stores the records of last 1000 cycles Memory for the last 100 failures Cycle counter USB port to record the operated cycles in the memory to a memory stick PC connection through USB / RS 485 port Ethernet port for remote access through internet by means of optional NüveCloser software NüveCloser allows to access operating parameters, memory, failure history and other technical parameters Panel type printer to keep the records of the sterilization cycle PROCESS EVALUATION AND SELF DIAGNOSTIC SYSTEM Compare the preset values with operating parameters using the process evaluation system When the operating parameters do not match the preset values, the sterilization cycle is cancelled and the user is warned Comprehensive self-diagnostic system for 19 possible failures such as power failure, heater failure, low water level, high pressure and temperature, sensor failure Help menu with the description of the failures

SAFETY OVER STANDARDS Authorization key to operate the steam sterilizer Password protected control system, service and calibration menu The door stops automatically in case of an obstruction on the door closing direction. The door is prevented from opening unless the safe unloading temperature has been reached and pressure has dropped to atmospheric pressure at the end of the sterilization cycle. The sterilization cycle can only be started if the steam pressure under the gasket is adequate for the operations. Manual control system for steam discharge, air intake, gasket vacuum and door opening in case of any failure Manometers for chamber, jacket, gasket and generator to easily follow the pressure levels Emergency stop button Colour of the display changes to red in case of any alarm condition along with an audible alarm Remote failure diagnostic by means of NüveCloser software Sending e-mails up to five e-mail addresses with the details of failure Optional AlerText SMS alarm system for ultimate security Safety valves against over pressure in the chamber, jacket and steam generator HEPA filter at air intake line Chamber and generator manufactured according to PED 2014/68 EC Validation port as standard Phone Alarm AlerText TM

DOUBLE DOOR VERSIONS NC 430, NC 570 and NC 710 are available as double door 4,3 colourful LCD display for the clean side Displayed parameters during sterilization cycle: - Chamber temperature and pressure - Name of the operating program - Phase of the operating program - Total elapsed time - Elapsed time of the phase Both doors cannot be opened at the same time and if the sterilization fails, the door of the clean side cannot be opened.

The Right Choice for the Right Results Nüve, which was founded in 1968, is one of the leading and outstanding manufacturers of Turkey in the field of laboratory and sterilization technology. Since its foundation, Nüve had contributed to the advancement of its products and production processes by means of technical innovations and investments made for research and development. With a network of 30 distributors in Turkey, Nüve holds the major part of the Turkish market. Strong international focusing; formulated, fast, economic solutions combined with continually evolving quality awareness and customer oriented services form a significant part of Nüve s business concept. Because of these special features, Nüve has become a fast growing company among its competitors. Having ISO 9001:2008 and ISO 13485:2012 certificates, Nüve is exporting to more than 100 countries by the contribution of its professional work force and very competitive quality and price. The manufacturing plant is 30 km away from Ankara, the capital city of Turkey and consists of 6000 m 2 closed area. High technology machine tools and sheet metal working machines are used for standard production. The quality of the raw materials and parts supplied plays an important role in obtaining a stable production of high quality products. The product range of Nüve is expanding every year proportional with its continuous research studies. Subject to ever-changing customer perceptions and worldwide technological improvements, also the development of products never ends at Nüve. The equipment that Nüve manufacture are mostly used in all kinds of medical laboratories, biotechnology, research and quality control laboratories of agriculture, botany and veterinary as well as in the quality control laboratories of various industries such as food, beverage, dairy, chemicals and pharmaceuticals. With its flexible mass production technology, fast delivery process, well established network of national and international distributors, quick and efficient after sales services and unlimited spare part supply, Nüve is ready to meet the needs and demands of its customers all times and just in time.

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. Saracalar Mah. Saracalar Kümeevleri No: 4/2 Akyurt 06750 ANKARA / TURKEY t. +90 312 399 28 30 f. +90 312 399 21 97 nuve.com.tr sales@nuve.com.tr 10.2017/Z15.K 34 002