Computerized Simulation of Automotive Air-Conditioning System: A Parametric Study

Similar documents
Indoor Air of a Double-Storey Residential House in Malaysia

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

System Modeling of Gas Engine Driven Heat Pump

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

Comfort and health-indoor air quality

Cold Storage Warehouse Dock Parametric Study

Performance Analysis of a Solid Desiccant Air Dehumidifier

Recent Advances in Energy, Environment and Economic Development

CASE STUDIES OF THERMALLY DRIVEN HEAT PUMP ASSISTED DRYING. Minh Cuong Tran, Jamy Logie, Bruno Vanslambrouck, Martijn van den Broek

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION THERMOELECTRIC REFRIGERATION SYSTEM WITH NOZZLE AND DIFFUSER THROUGH INCORPORATION OF PHASE CHANGE MATERIAL

Thermodynamics II Chapter 6 Mixtures & Psychrometry

EXPERIMENTAL INVESTIGATION OF THE AIR CLEANING EFFECT OF A DESICCANT DEHUMIDIFIER ON PERCEIVED AIR QUALITY

STUDY ON TEMPERATURE, RH AND AIR FLOW VELOCITY DISTRIBUTION INSIDE THE GREENHOUSE EFFECT SOLAR DRYER

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

An Experimental Study on Clothes Drying Using Waste Heat from Split Type Air Conditioner

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

A study on performance improvement of corrugated type total heat exchanger considering the structure of flow passage on surface

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

THERMAL ANALYSIS OF CAR AIR COOLER

K.F. Fong *, C.K. Lee, T.T. Chow

Numerical study of heat pipe application in heat recovery systems

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Experimental Investigation of a Heat Pump Assisted Fluidized Bed Dryer

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

FROSTING BEHAVIOR OF FIN-TUBE HEAT EXCHANGER ACCORDING TO REFRIGERANT FLOW TYPE

seasons in regions with hot, humid climates. For this reason, a dehumidification system with a radiant panel system needs to be developed. In a former

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Global Journal of Engineering Science and Research Management

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

Air Conditioning System Sizing for Pure Electric Vehicle

ω = (1) Kirby S. Chapman Ph.D.

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Chapter 10. Refrigeration and Heat Pump Systems

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

Optimization of Hybrid Noncondensable Gas Removal System for a Flash Steam Geothermal Power Plant

Thermodynamics II Chapter 5 Refrigeration

Desiccant Cooling with Solar Energy

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

Performance investigation of Air-conditioning system using ejector as expansion device

Evaluation of Liquid Water Content in Thermal Efficient Heating Mechanism Using Water Vapor for Industrial Furnace

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

Clemens Felsmann 1, Jean Lebrun 2, Vincent Lemort 2 and Aad Wijsman 3 ABSTRACT INTRODUCTION METHODOLOGY

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 4, 2011

Air Conditioning System with Modified Condenser Ducts and Evaporative Cooling

Available online at Energy Procedia 6 (2011) MEDGREEN 2011-LB

A study of Transient Performance of A Cascade Heat Pump System

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

GROUND COOLING OF VENTILATION AIR FOR ENERGY EFFICIENT HOUSE IN MALAYSIA: A CASE STUDY OF THE COOLTEK HOUSE

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater

How to ensure Thermal Comfort in buildings with CFD

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

FABRICATION OF REFRIGERANT FLOW RATE WITH SPIRALLY COILED CAPILLARY TUBE

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

Numerical investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper balconies with open upstand

Effects of Non-Uniform Refrigerant and Air Flow Distributions on Finned- Tube Evaporator Performance

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

MODELLING AND SIMULATION OF A ROOM WITH A RADIANT COOLING CEILING. Technicka 4, Prague 6, Czech Republic

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

Heat pump supplemental heating system for motor vehicles

HFC/HC BLEND FOR CAR CLIMATE CONTROL WITH MINERAL OIL AS LUBRICANT

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

Mathematical Simulation of Longan Fruit Drying

TECHNICAL NOTE ON EVAPORATIVE COOLING. Renato Lazzarin, President of the IIR s Commission E1

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

Design and Experimental Studies on Modified Solar Dryer

Preliminary Findings on the Performance of a New Residential Solar Desiccant Air-Conditioner

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air

Binoe E. ABUAN, Menandro S. BERANA, Ruben A. BONGAT. University of the Philippines Diliman, Quezon City, Philippines

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

POSSIBILITY TO USE SOLAR INDUCED VENTILATION STRATEGIES IN TROPICAL CONDITIONS BY COMPUTATIONAL FLUID DYNAMIC SIMULATION

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I

Performance Analysis of Solar Assisted Cascade Refrigeration System of Cold Storage System

A New Dedicated Outdoor Air System with Exhaust Air heat recovery

Residential ventilation concepts based on the idea of displacement airflow distribution

Transcription:

www.ijcsi.org 787 Computerized Simulation of Automotive Air-Conditioning System: A Parametric Study Haslinda Mohamed Kamar 1, Nazri Kamsah 2 and Mohd Yusoff Senawi 3 1 Department of Thermo-Fluid, Universiti Teknologi Malaysia 81310 UTM Skudai, Johor, Malaysia 2 Department of Thermo-Fluid, Universiti Teknologi Malaysia 81310 UTM Skudai, Johor, Malaysia 3 Department of Thermo-Fluid, Universiti Teknologi Malaysia 81310 UTM Skudai, Johor, Malaysia Abstract This paper presents results of a parametric study performed on an automotive air-conditioning (AAC) system of a passenger car. The goals are to assess the effects of varying the volumetric flow rate of supply air, number of occupants, vehicle speed, and the fractional ventilation air intake (XOA), on the dry-bulb temperature and specific humidity of the air inside the passenger s cabin, and on the evaporator coil cooling load of the AAC system. Results of the parametric study show that increasing the supply air flow rate reduces the dry-bulb temperature of the cabin air, increases both the specific humidity of the air and the evaporator coil load. Increasing the number of occupants in the passenger cabin causes the cabin air temperature, specific humidity and the evaporator coil load to increase. Increasing the vehicle speed causes the specific humidity of the cabin air and the evaporator coil cooling load to increase but the dry-bulb temperature of the air is not significantly affected. Increasing the fractional fresh air intake (XOA) also increases the cabin air specific humidity and the evaporator coil cooling load. Keywords: Automotive air conditioning (AAC), passenger car cabin, parametric study 1. Introduction Automotive air-conditioning (AAC) is a necessity for thermal comfort in the cabin of a passenger vehicle especially for people who are living in countries with hot and humid climate. However, the extra weight added to the vehicle and the operation of the AAC system cause the fuel consumption of the vehicle to increase. The additional fuel consumption in turn results in higher emission of greenhouse gases that pollute the environments. Therefore augmentation of the AAC system efficiency and evaluation of its thermal performance has become important. The AAC system is often operated under varying conditions thus substantial efforts are required to evaluate its performance. These conditions include the temperature of the air entering the evaporator and condenser, the evaporator air volumetric flow rate and ventilation mode, the compressor speed, the condenser face air velocity, passenger cabin s material, the number of occupants, and the weather conditions which affect the internal and external sensible thermal loads. The largest auxiliary load on a passenger car s engine is input power required by the air-conditioning system s compressor. During a peak load the compressor would consume up to 5 to 6 kw of power from the vehicle s engine power output. This is equivalent to a vehicle being driven at a speed of 56 km/h. The additional fuel consumption when the air-conditioning system is in-used is quite substantial. One study indicated that the airconditioner usage reduces fuel economy by about 20%. It also increases the emissions of nitrogen oxides by about 80% and carbon dioxide (CO) by about 70%, although the actual numbers depend on the actual driving conditions. A semi-empirical computer simulation program (CARSIM) for simulating thermal and energy performance of an automotive air-conditioning (AAC) system of a passenger car has been developed [1]. The empirical correlations for evaporator sensible and latent heat transfer were embedded in the loads calculation program to enable the determination of evaporator inlet and outlet air conditions and the passenger cabin air conditions. The computer program has been validated by comparing its predicted outputs with the data obtained from an actual road test on a Proton Wira Aeroback passenger car. The results predicted by the CARSIM computer program were found to have very good agreement with the actual road test data, with errors ranging between 2 to 4%. This paper presents results of a parametric study performed on the automotive air-conditioning (AAC) system of the Proton Wira Aeroback passenger car using the CARSIM computer simulation program. The goal is to

www.ijcsi.org 788 investigate the effects of: (1) supply air volumetric flow rate, (2) number of occupants, (3) vehicle speed, and (4) the fractional outside air intake (XOA),, on the cabin s air dry-bulb temperature, specific humidity and the total evaporator coil (cooling) load of the AAC system. A base case simulation was performed on the system to find out the trend of variation of the cabin air dry-bulb temperature, specific humidity and the total evaporator coil (cooling) load as the time is varied from 10 am to 2 pm. 2. Base Case Conditions A computer simulation for the base case conditions was performed on the automotive air-conditioning (AAC) system by using the CARSIM computer simulation program developed earlier and reported in [1]. The input data used for the computer simulation are given in Table 1. system is being turned-on the cabin air temperature drops slightly by about 0.05 C. This is due to a sudden cooling of the air when cooled air is suddenly blown into the cabin. Thereafter, the cabin air temperature rises steadily with time, from 18.4 C until it reaches about 18.8 C at about 1 pm. The cabin air temperature is affected by the temperature of the ambient air, t 0. The ambient air temperature rises steadily with time as the intensity of solar radiation increases. This causes the cabin air temperature to rise in a fashion seen in the figure. However, as the solar radiation intensity decreases after 1 pm, the cabin air temperature also decreases steadily, from 18.8 C to about 18.6 CC at 2 pm. Although the dry- air appears to vary with bulb temperature of the cabin time, the range of its variation is quite small, i.e. less than 0.5 C, and hence can be considered insignificant. Table 1 Parameters for the base case condition. Parameters Value PASSENGER CABIN t, w 3 3 Exhaust Vehicle speed ~ 90 km/h Occupant ~ one (1) Colour of the car body Glass thickness A/C blower speed ~ light yellow (α = 0.5) ~ 3 mm (shading coefficient = 1) ~ maximum Travelling duration ~ 4 hours (10 am to 2 pm) Fraction of outside air (XOA) ~ 0.16 (or 16% of outside air) Supply Air V&, t, w 2 2 EVAPORATOR COIL Return Air t, w 3 3 Inlet Air t, w 1 1 Outside Air t, w 0 0 The computer simulation was performed as if the vehicle is driven at a constant speed of 90 km/h with only one occupant. The travelling duration is four hours i.e. from 10 am (or 600 minutes past midnight) to 2 pm (or 840 minutes past midnight). The car air-conditioning system is turned-on during this period in which the blower fan speed is set to a maximum. The fractional outside air (XOA) is set at a fixed value of 16%. The air in the passenger s cabin gains sensible heat from the surrounding air and latent heat from the passenger. As a result, the cabin air dry-bulb temperature, specific humidity and the evaporator coil cooling load will vary with time during the simulated journey. The simulation for the base case conditions was carried out to find out the trend in which these parameters vary with the time. Figure 1 shows a schematic diagram of the simplified air-conditioning system of the passenger car considered in this study. Figure 2 shows the variation of dry-bulb temperature of the cabin air with time in minutes,, measured after midnight. The time t = 600 minutes corresponds to 10 am while t = 840 minutes corresponds to 2 pm. It can be seen that during the first five minutes after the air-conditioning Figure 1 Schematic diagram of an air-conditioning system of a passenger car [1]. Figure 2 Variation of dry-bulb temperature of the cabin air for the base case condition.

www.ijcsi.org 789 The variation of specific humidity of the cabin air with time is shown in Figure 3. The air specific humidity is related to the saturation pressure of water vapor that exists in the air. The saturation pressure increases dramatically with the dry-bulb temperature of the air. Hence, when the temperature of the cabin air rises, the specific humidity of the air also increases in a nearly similar fashion. It can be noted that the specific humidity of the air increases steadily from about 6.26 g/kg at 10 am (600 minutes after midnight) to a highest value of about 6.45 g/kg at 1 pm (780 minutes after midnight). Thereafter, the specific humidity of the cabin air decreases with time, as the drybulb temperature falls. At 2 pm (840 minutes after midnight) the specific humidity of the cabin air drops to about 6.40 g/kg. Figure 4 shows variations of the evaporator coil cooling load with time. The cooling load is the sum of sensible heat load, Q C,S and latent heat load, Q C,L. The sensible heat is influenced by the temperature t 1 of the air coming into the cooling coil. The latent heat is influenced by the specific humidity w 1 of the ncoming air. The incoming air temperature t 1 is in turn affected by the temperature of the incoming outside air, t 0 and the temperature of the return air, t 3. Both the t 0 and t 3 increases with time causing the temperature t 1 to continuously increases from 10 am to 1 pm. This in turn causes a steady increase in the sensible heat load of the coil during the same period. As both the t 0 and t 3 decreases after 1 pm, the sensible heat load also decreases. The specific humidity of the air coming into the cooling coil, w 2 is influenced by the humidity of the incoming outside air, w 0 and the humidity of the return air, w 3. Both the w 0 and w 3 increase steadily from 10 am to 1 pm causing the latent heat load to rise steadily during the same period. When both the w 0 and w 3 decrease after 1 pm, the latent heat load of the evaporator coil also decreases. Although the specific humidity varies with time, the range of its variation is quite small. 3. Parametric Study Figure 3 Variation of specific humidity of the cabin air for base case condition. A parametric study was performed by computer simulation to investigate the effects of varying the supply-air volume flow rate, number of occupants, vehicle speed and the fractional outside air (XOA) on the cabin air dry-bulb temperature, specific humidity and the evaporator coil cooling load. The supply-air volume flow rate was varied from 70 L/s to 100 L/s with a 10 L/s interval. The number of occupants of the vehicle was varied from one to four persons. The vehicle speed was varied from 60 km/h to 105 km/h with an interval of 15 km/h. Finally, the fractional outside air (XOA) which is the ratio between the ventilation-air volume flow rate and the cooled-air volume flow rate, was varied from 0..2 to 0.3, with a 0.05 interval. When the cooled-air volume flow rate was varied during the simulation, other parameters that are listed in Table 1 were held constant at the prescribed values. Similar procedure was followed when the other parameters were varied. 4. Results and Discussion 4.1 Effects of Supply-Air Volume Flow Rate Figure 4 Variation of evaporator coil cooling load with time for base case condition. Figure 5 shows the effect of cooled-air volume flow rate on the dry-bulb temperature of the cabin air. The simulation results show that for a given air flow rate, the dry-bulb temperature varies with time in a very similar manner as that for the base case. At a given cooled-air volume flow rate, the cabin air temperature increases

www.ijcsi.org 790 steadily from 10 am (600 minutes past midnight) and reaches the highest value at about 1 pm (780 minutes after midnight). After reaching a maximum value, the cabin air temperature decreases with time. However, increasing the cooled-air volume flow rate decreases the dry-bulb temperature of the cabin air. On average, the cabin air temperature decreases by about 0.5 o C (or 2.5%) for every 10 L/s increment of the cooled-air volume flow rate. The highest temperature of the cabin air temperature is 20.2 o C, at 1 pm when the cooled-air volume flow rate is 70 L/s. The temperature falls to about 18.7 C when the cooled-air volume flow rate is increased to 100 L/s, which can be considered as a significant temperature change. 100 L/s 90 L/s 80 L/s 70 L/s 70 L/s 80 L/s 90 L/s 100 L/s Figure 6 Effect of cooled-air volume flow rate on specific humidity of the cabin air. The effect of cooled-air volume flow rate on the evaporator coil total cooling load is shown in Figure 7. It can be seen that, for a given air volume flow rate, the variation of the coil cooling load with time is very much similar to that for the base case. However, increasing the volumetric flow rate of the cooled-air increases the coil cooling load, at any given time. On average, the simulation results show that the cooling load increases by about 6 to 8% for each 10 L/s increase in the cooled-air volume flow rate. Figure 5 Variation of evaporator coil cooling load with time for base case condition. Figure 6 shows the effect of cooled-airr volume flow rate on the specific humidity of the air inside the passenger cabin. Again, the simulation results show that the humidity of the cabin air varies with time in more or less similar manner, regardless of the cooled-air volume flow rate. However, the specific humidity of the cabin air increases when the cooled-air volume flow rate is increased. Increasing the cooled-air volume flow rate means the velocity of the air flowing through the evaporator coil is increased. This reduces the ability of the evaporator coil to remove moisture from the air that is passing through it. Consequently, the specific humidity of the cabin air will rise. On average, results of the simulation results show that the specific humidity of the cabin air rises by about 5.4% (or 0.34 g/kg) for each 10 L/s increasee in the cooled-air volume flow rate. 100 L/s 90 L/s 80 L/s 70 L/s Figure 7 Effect of cooled-air volume flow rate on the evaporator coil cooling load. 4.2 Effects of Number of Occupant The computer simulation results on the effect of the number of occupants in the passenger cabin on the dry- bulb temperature of the cabin air is shown in Figure 8.

www.ijcsi.org 791 4 persons 4 persons 3 persons 2 persons 1 person 3 persons 2 persons 1 person Figure 8 Effect of number of occupants on the dry-bulb d temperature of the cabin air. Note that the curve for one person represents that for the base case condition (see Figure 2) ). The simulation results indicate that the variation of cabin air temperature with time is not much affected by the number of occupant in the cabin. However, at a any given time, when the number of occupants is increased the cabin air dry-bulb temperature increases. This is because human body continuously transfers energy in the form of sensible heat which will cause the cabin air temperature to rise. As more passengers occupy the cabin space, more sensible heat is transferred to the cabin air causing greater temperature rise of the air. On average, the simulation results show that the cabin air temperature increases by about 1.2 % or 0.23 o C for each additional person occupying the passenger cabin. This can be considered as a significant increment. The effect of the number of occupants on the specific humidity of the cabin air is shown in Figure 9. Note that the curve for one person represents the simulation result for a base case condition (see Figure 3). As seen in the figure, the variation of specific humidity of the cabin air with time is generally not affected by the number of occupants present in the passenger cabin. However, the simulation results show that at any given time, increasing the number of occupants will significantly increases the specific humidity of the cabin air. This is because human releases energy into the cabin air in the form of latent heat, through perspiration process and breathing. Hence when more people occupy the cabin space, the more latent heat and moisture are added to the cabin air resulting in significant increase in the specific humidity of the air. On average, the humidity of the cabin air rises by about 5.4% or 0.38 g/kg for each additional occupant in the passenger cabin. Figure 9 Effect of number of occupants on cabin air specific humidity. Figure 10 shows the effect of the number of occupants on the evaporator coil cooling load. The curve for one person represents the simulation result for the base case condition (see Figure 4). It is seen that the variation of the coil cooling load with time appears to be unaffected by the number of occupants in the cabin. However, increasing the number of occupant will increase the amount of sensible and latent heat in the cabin air. This represents the additional thermal load that needs to be absorbed from the cabin air by the air-conditioning system. The mass flow rate of the refrigerant through the evaporator must be increase to achieve this. This is accomplished through the increase in the compressor speed. The figure shows that, on average, for each additional occupant in the cabin, the evaporator coil cooling load rises by 2.5% or about 0.06 kw. Figure 10 Effect of number of occupants on the evaporator coil cooling load.

www.ijcsi.org 792 4.3 Effects of Vehicle Speed Computer simulation was also carried out to determine the effects of varying the vehicle speed on the dry-bulb temperature and specific humidity of the cabin air, and the evaporator coil cooling load. The vehiclee speed was varied from 60 km/h to 105 km/h with 15 km/h interval. specific humidity of the cabin air. On average, the specific humidity drops by about 5.4% or 0.33 g/kg for every 15 km/h increment of the vehiclee speed. 60 km/h 75 km/h 60 km/h 105 km/h 90 km/h 75 km/h 90 km/h 105 km/h Figure 12 Effect of vehicle speed on the specific humidity of the cabin air. Figure 11 Effect of vehicle speed on the dry-bulb temperature of the cabin air. Increasing the vehicle speed will cause the compressor of the air-conditioning system to operatee at higher speed. This in turn leads to a higher mass flow rate of the refrigerant. As a result, more heat is absorbed by the refrigerant from the air passing through the evaporator coil [5]. The dry-bulb temperature of the cabin air will be reduced since the supply air enters the cabin at lower temperature. This is situation is shown in Figure 11. However, as seen from the figure, the reduction in the cabin air dry-bulb temperature is very small. On average, the simulation results show that the cabin air temperature drops only by about 0.1% or 0.02 o C for every 15 km/h increment of the vehicle speed. This result is however consistent with that reported in the literature [6]. The effect of varying vehicle speed on the specific humidity of the cabin air is shown in Figure 12. In general, the simulation results show that the vehicle speed does not have significant effects on the trend of variation of specific humidity of the cabin air with time. However, at any given time, the specific humidity of the cabin air decreases quite significantly as the vehicle speed is increased. This results suggests that as the vehicle moves at higher speed, more moisture is absorbed from the air that is passing through the evaporator coil. As a result, the air that is supplied into the cabin air is dryer. This causes the reduction in the The results of computer simulation shows that the vehicle speed has insignificant effects on the variation of evaporator coil cooling load with time. This is shown in Figure 13. However, at any given time, the coil cooling load increases as the speed of the vehicle is increased. On average, for every increment of 15 km/h, the coil load increases by 3.9% or 0.09 kw. However the increase in the cooling load is somewhat smaller when the vehicle speed is increased from 75 km/h to 90 km/h. 105 km/h 90 km/h 75 km/h 60 km/h Figure 13 Effect of vehicle speed on the evaporator coil cooling load.

www.ijcsi.org 793 4.4 Effects of Fractional Ventilation Air Intake Fractional ventilation air intake (XOA) is the ratio between the ventilation-air flow rate and the air- conditioning system s supply-air flow rate. It s value ranges from 0 for air recirculation mode (no ventilation- usage (no air air) and 1 for a ventilation-air full recirculation). humidity of the cabin air is increased by about 5.2% or 0.37 g/kg for every 0.05 increment of the XOA. XOA = 0.3 XOA = 0.25 XOA = 0.2 XOA = 0.3 Figure 15 Effect of varying the XOA on the specific humidity of the cabin air. Figure 14 Effect of XOA on the dry-bulb temperature of the cabin air. In this study the XOA was varied from 0.2 to 0.3 with a 0.05 increment the effects of doing this on the dry-bulb temperature and specific humidity of the cabin air, and the cooling load of the evaporator coil weree investigated. The effects of varying the XOA on the dry-bulb temperature of the cabin air is shown in Figure 14. It is seen from the figure that the variation of the cabin air temperature with time is not significantly affected by the value of the XOA. Also, increasing the XOA from 0.2 to 0..3 does not seem to have appreciable impact on the cabin air dry-bulb temperature. This could be because the variation of the XOA considered in this study is too small. The effect of varying the XOA on the specific humidity of the cabin air is shown in Figure 15. The simulation results show that the variation of specific humidity with time is generally not much affected by the value of the XOA. However, at any given time, increasing the value of XOA causes the specific humidity of the cabin air to increase. When the XOA is increased the specific humidity of the air at the inlet of the evaporator coil is also increased because the outside air has higher moisture content compared with the returned air from the cabin. When the moisture content of the air at the inlet of the evaporator coil is higher, the ability of the coil to remove the moisture is somewhat reduced. As a result, the air leaving the evaporator coil, which is supplied into the cabin, will have slightly higher moisture content. On average, the specific The simulation result on the effects of varying the XOA on the evaporator coil cooling load is shown in Figure 16. It is seen from the figure that the value of XOA does not have any significant effect on the variation of the cooling load with time. However, at any given time, increasing the XOA causes the evaporator cooling load to increase quite significantly. The increase in the coil load is a direct consequence of the increasee in temperature and specific humidity of the air inlet to the evaporator coil, as more outside air is introduced to the system. The outside air has higher temperature and humidity than the cabin. On average, for every 0.05 increment of the XOA, the coil cooling total load rises by about 6.8% (or 180 Watt ), which can be considered as significant increment. XOA = 0.3 XOA = 0.25 XOA = 0.2 Figure 16 Effect of varying the XOA on the evaporator coil cooling load.

www.ijcsi.org 794 5. Conclusion A semi-empirical computer simulation program (CARSIM) has been developed for simulating thermal and energy performance of an automotive air-conditioning (AAC) system. The computer program was used to perform a parametric study to investigate the effects of varying the volume flow rate of supply air, the number of occupants in the passenger cabin, the vehicle speed and the fractional outside air intake (XOA) on the dry-bulb temperature and specific humidity of the cabin air, and on the evaporator coil cooling load of a 1.6 L Proton Wira passenger car. Results of the parametric study show that for each 10 L/s increment of the supply air flow rate the cabin air temperature is reduced by about 2.5%, the specific humidity increases by 5.4%, and the evaporator coil cooling load increases by about 6%. For each additional occupant in the passenger compartment, the cabin air temperature, specific humidity, and evaporator coil cooling load are increased by 1.2%, 5.4%, and 2.5%, respectively. For every 15 km/h increase of the vehicle speed, the specific humidity of the cabin air is increased by 5.4% and the evaporator coil cooling load by 3.9%. The temperature of the cabin air appears to be not affected by the vehicle speed. The fractional fresh air intake (XOA) has no significant influence on the cabin air temperature. However, for every 0.05 increase of XOA, the interior air specific humidity increases by 5.2% and the evaporator coil cooling load also increased, by about 6.8%. Acknowledgement The authors would like to acknowledge the financial supports from the Universiti Teknologi Malaysia and research funding given by Ministry of Science, Technology and Innovation, (MOSTI) Malaysia and the Research Management Centre (RMC), Universiti Teknologi Malaysia, through an IRPA grant no. 74062. References [1] Haslinda Mohamed Kamar, Mohd Yusoff Senawi and Nazri Kamsah, Computerized Simulation of Automotive Air-Conditioning System: Development of Mathematical Model and Its Validation, The International Journal of Computer Science Issues, Vol. 9, Issue 2, No 2, March 2012. [2] Moller, S. K. and Wooldridge, M. J., User s Guide for the Computer Program BUNYIP: Building Energy Investigation Package (Version 2.0), Highett, Victoria, Australia. (1985). [3] Kohler, J., Kuhn, B. and Beer, H., Numerical Calculation of The Distribution of Temperature And Heat Flux In Buses Under The Influence of The Vehicle Air-Conditioning System. ASHRAE Transactions. 96 (Part 1) (1990) 432 446. [4] H. Zhang, L. Dai, G. Xu, Y. Li, W. Chen, W-Q., Tao Studies of Air-flow and Temperature Fields Inside a Passenger Compartment for Improving Thermal Comfort and Saving Energy: Part I Test/Numerical Model and Validation. Applied Thermal Engineering. 29 (2009) 2022 2027. [5] Somchai Wongwises, Amnouy Kamboon and Banchob Orachon, Experimental Investigation of Hydrocarbon Mixtures to Replace HFC-134a in an Automotive Air Conditioning System. Energy Conversion and Management. 47 (2006) 1644 1659. [6] H. Zhang, L. Dai, G. Xu, Y. Li, W. Chen, W-Q., Tao. Studies of Air-flow and Temperature Fields Inside a Passenger Compartment for Improving Thermal Comfort and Saving Energy: Part II Test/Numerical Model and Validation. Applied Thermal Engineering. 29 (2009) 2028 2036. [7] Mezrhab, A. and Bouzidi, M., Computation of Thermal Comfort Inside a Passenger Car Compartment. Applied Thermal Engineering. 26 (2006) 1697 1704. Haslinda Mohamed Kamar, is a member of ASHRAE. She received her Bachelor s Degree in Mechanical Engineering from University of Glasgow, Scotland in 1993, Master and Ph.D in Mechanical Engineering from University Teknologi Malaysia in 1997 and 2009, respectively. She is now a senior lecturer in the Faculty of Mechanical Engineering, Universiti Teknologi Malaysia. Her areas of interest are automotive air-conditioning system, thermal comfort & energy efficiency in hot climates, indoor air quality (IAQ), natural ventilation as passive cooling strategy in buildings and computational fluid dynamics (CFD) modeling and simulation. Nazri Kamsah is a member of ASHRAE. He received his Bachelor s Degree in Mechanical Engineering from University of Sunderland, United Kingdom in 1983, Masters of Engineering (Mechanical) from Universiti Teknologi Malaysia in 1988, and Ph.D in Mechanical Engineering from University of New Hampshire, Durham, USA in 2001. He is currently a senior lecturer in the Faculty of Mechanical Engineering, Universiti Teknologi Malaysia. His areas of interest include computational solid mechanics, finite element modeling and simulation, thermal management in microelectronics, thermal comfort and energy efficiency in buildings, natural ventilation as passive cooling strategy for buildings, indoor air quality (IAQ) and computational fluid dynamics (CFD) modeling and simulation. Mohd Yusoff Senawi, graduated with Bachelor of Mechanical Engineering from The University of New South Wales in 1987. Received Post Graduate Diploma in Computer Science, Master and Ph.D in Mechanical Engineering from Universiti Teknologi Malaysia (UTM) in 1989, 1993 and 2000, respectively. Currently a Senior Lecturer at UTM. Research interests include cooling loads calculation and energy analysis of air conditioning systems.