Rosemount 3051SFP Proplate Flowmeter

Similar documents
Rosemount 3051SFC Compact Orifice Flowmeter

Annubar Flowmeter Series

Rosemount 3051CFP Integral Orifice Flowmeter

Rosemount 3095MFC Compact Orifice Mass Flowmeter

Rosemount Integral Orifice Flowmeter Series

Rosemount 3051CFC Compact Flowmeter

Rosemount 3051L Level Transmitter

Rosemount 3051CF DP Flowmeters

Rosemount 2051CF DP Flowmeters

Rosemount 2051T In-Line Pressure Transmitter

Rosemount 752 Fieldbus Remote Indicator

Rosemount 3051S Series of Instrumentation

Rosemount 4500 Hygienic Pressure Transmitter

Rosemount 3051S Series of Instrumentation

Rosemount 2051 Pressure Transmitter

Rosemount 2051T In-line Pressure Transmitter

Model 144H. Product Data Sheet , Rev DB February Content

Rosemount 3051 Pressure Transmitter

Rosemount 2051 Pressure Transmitter

Rosemount 8800D Series Vortex Flowmeter

Rosemount 2088 Absolute and Gage Pressure Transmitter

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

Rosemount 2090P Pulp and Paper Pressure Transmitter

Rosemount 4500 Hygienic Pressure Transmitter. Start

Rosemount Compact Orifice Flowmeter Series

Model 144H. Product Data Sheet , Rev DB February Content

Rosemount 2090F Sanitary Pressure Transmitter with HART Protocol

Rosemount 2051 Pressure Transmitter with 4-20 ma HART and 1-5 Vdc HART Low Power Protocol

Rosemount 3051 Pressure Transmitter

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

Rosemount 2088 Absolute and Gage Pressure Transmitter

Rosemount 3051 Pressure Transmitter

Rosemount 2088, 2090P, and 2090F Pressure Transmitters

J. Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter with HART Protocol.

Rosemount 3051 Pressure Transmitter Includes Transmitter Option TR ProductDiscontinued. Start

Rosemount 3144P Rosemount 3144P Temperature Transmitter

Rosemount 3144P Temperature Transmitter

Rosemount 3144P Temperature Transmitter

Rosemount 3144P Rosemount 3144P Temperature Transmitter

Rosemount 3051 Pressure Transmitter

Absolute and Gage Pressure Transmitter

Rosemount 8800D Series Vortex Flowmeter

Rosemount 4600 Oil & Gas Panel Pressure Transmitter

Rosemount 3100 Series Ultrasonic Level Transmitters

Sanitary Pressure Transmitter

Rosemount 644 Temperature Transmitter

SmartPower Solutions. SmartPower Solutions. Product Data Sheet , Rev AC January Contents

Rosemount 3100 Series Ultrasonic Level Transmitters

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Rosemount 2090F Hygienic Pressure Transmitter

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 3051P In-Line Pressure Transmitter. Product Data Sheet August , Rev BA

Rosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014

Rosemount 3144P Temperature Transmitter with HART Protocol

Rosemount 1595 Conditioning Orifice Plate

Rosemount 3144P Temperature Transmitter

Rosemount 248 Temperature Transmitter. Quick Start Guide , Rev. EA April 2013

Rosemount 644H and 644R Smart Temperature Transmitters

SmartLine. RMA803 SmartLine Remote Fieldbus Indicator Specification 34-ST-03-90, December Technical Information.

Rosemount 3051S MultiVariable Extension Supplement

Rosemount 848T High Density Temperature Measurement Family

MODEL APT 3700N. Smart Pressure Transmitter For Nuclear Service. Duon System Co., Ltd. for Differential / Gauge / Absolute Pressure Measurement

Rosemount 3490 Series

Rosemount 148 Temperature Transmitter. Reference Manual , Rev CA April 2014

Rosemount 702 Wireless Discrete Transmitter

Rosemount 248 Temperature Transmitter

Rosemount 4600 Oil & Gas Panel Pressure Transmitter. Quick Start Guide , Rev GA September 2017

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

Quick Start Guide , Rev. BB February Rosemount 1495 Orifice Plate Rosemount 1496 Orifice Flange Union

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Ar-Mite TM Low Flow Armored Flowmeter

Rosemount 8800D Series Vortex Flowmeter. Quick Start Guide , Rev FE October 2018

Quick Start Guide , Rev CB May Rosemount 3144P Temperature Transmitters with FOUNDATION fieldbus Protocol

Configuration Data Sheet

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

FAHM Co. Temperature Transmitter PTT74 Series

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

OPTIBAR DP 7060 Supplementary Instructions

Temperature Solutions Line Card

Rosemount 2088 Absolute and Gage Pressure Transmitter

Rosemount 8732E Magnetic Flowmeter System with Profibus PA digital fieldbus (Transmitter and Sensor)

High Pressure Conductivity Monitor

Temperature Measurement Transmitters for field mounting

VersaFlow Coriolis 100 Mass Flow Sensor Technical Datasheet. Specification

Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

Rosemount 3051S MultiVariable Transmitter Rosemount 3051SF Series Flowmeter MultiVariable Transmitter

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016

Rosemount 2120 Vibrating Fork Liquid Level Switch

Rosemount 3051S MultiVariable Transmitter

Enraf Servo Gauge 854 ATG

MT3809G Series. Data Sheet. Metal Tube Variable Area Flowmeters. Overview. Product Description. Variable Area

Operating Instructions Edition 02/2007

Rosemount 248 Temperature Transmitter

PURCHASING SECTION th Street, Surrey, B.C. V3S 3C7 Tel: Fax: ADDENDUM NO.

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

Transcription:

SPECIFICATIONS Rosemount 3051SFP Proplate Flowmeter Performance System Reference Accuracy Percentage (%) of volumetric flow rate (1) Beta ( ) (2) Repeatability ±0.1% Line Sizes 1 /2-in. (15 mm) 1-in. (25 mm) 1 1 /2-in. (40 mm) Classic (8:1 flow turndown) (1) Without associated straight run piping, discharge coefficient uncertainty can add up to 1.5% - 5% additional error. Consult the factory for additional information. (2) = Orifice Plate Bore body I.D. Ultra (8:1 flow turndown) Ultra for Flow (10:1 flow turndown) < 0.1 ±2.70% ±2.65% ±2.60% 0.1 < < 0.2 ±1.60% ±1.45% 1.40% 0.2 < < 0.6 ±1.20% ±1.10% ±0.95% 0.6 < < 0.8 ±1.80% ±1.70% ±1.65% Functional Service Liquid Gas Steam 4 20 ma/hart Zero and Span Adjustment Zero and span values can be set anywhere within the range. Span must be greater than or equal to the minimum span. Output Two-wire 4 20 ma is user-selectable for linear or square root output. Digital process variable superimposed on 4 20 ma signal, available to any host that conforms to the HART protocol. Power Supply External power supply required. Standard transmitter (4 20 ma): 10.5 to 42.4 V dc with no load 3051S SIS Safety transmitter: 12 to 42 Vdc with no load 3051S HART Diagnostics transmitter: 12 to 42 Vdc with no load Performance Statement Assumptions Use associated piping. Electronics are trimmed for optimum flow accuracy Sizing Contact a Emerson Process Management sales representative for assistance. A Configuration Data Sheet is required prior to order for application verification. 4

Rosemount Integral Orifice Load Limitations Maximum loop resistance is determined by the voltage level of the external power supply, as described by: Standard Transmitter Maximum Loop Resistance = 43.5 * (Power Supply Voltage 10.5) Load (Ohms) 1387 1000 500 Operating Region 0 10.5 20 30 Voltage (V dc) 42.4 The HART communicator requires a minimum loop resistance of 250 for communication. 3051S SIS Safety Transmitter (output code B) 3051S HART Diagnostics Transmitter (option code DA1) Maximum Loop Resistance = 43.5 * (Power Supply Voltage 12.0) Load (Ohms) 1322 1000 500 Operating Region 0 12.0 20 30 Voltage (V dc) 42.4 The HART communicator requires a minimum loop resistance of 250 for communication. HART Diagnostics Suite (Option Code DA1) The 3051S HART Diagnostics Transmitter provides Abnormal Situation Prevention (ASP) indication, device operating hours, variable logging, loop output readback diagnostic, and enhanced EDDL graphic displays for easy visual analysis. The integral statistical process monitoring (SPM) technology calculates the mean and standard deviation of the process variable 22 times per second and makes them available to the user. The 3051S ASP algorithm uses these values and highly flexible configuration options for customization to detect many user-defined or application specific abnormal situations (e.g. plugged impulse line detection). The device operating hours are logged along with the occurrence of diagnostic events to enable quick troubleshooting of application and installation issues. FOUNDATION fieldbus Power Supply External power supply required; transmitters operate on 9.0 to 32.0 V dc transmitter terminal voltage. Current Draw 17.5 ma for all configurations (including LCD display option) FOUNDATION fieldbus Parameters Schedule Entries Links Virtual Communications Relationships (VCR) 14 (max.) 30 (max.) 20 (max.) Standard Function Blocks Resource Block Contains hardware, electronics, and diagnostic information. Transducer Block Contains actual sensor measurement data including the sensor diagnostics and the ability to trim the pressure sensor or recall factory defaults. LCD Block Configures the local display. 2 Analog Input Blocks Processes the measurements for input into other function blocks. The output value is in engineering or custom units and contains a status indicating measurement quality. PID Block with Auto-tune Contains all logic to perform PID control in the field including cascade and feedforward. Auto-tune capability allows for superior tuning for optimized control performance. Backup Link Active Scheduler (LAS) The transmitter can function as a Link Active Scheduler if the current link master device fails or is removed from the segment. Software Upgrade in the Field Software for the 3051S with FOUNDATION fieldbus is easy to upgrade in the field using the FOUNDATION fieldbus Common Device Software Download procedure. PlantWeb Alerts Enable the full power of the PlantWeb digital architecture by diagnosing instrumentation issues, communicating advisory, maintenance, and failure details, and recommending a solution. Advanced Control Function Block Suite (Option Code A01) Input Selector Block Selects between inputs and generates an output using specific selection strategies such as minimum, maximum, midpoint, average, or first good. Arithmetic Block Provides pre-defined application-based equations including flow with partial density compensation, electronic remote seals, hydrostatic tank gauging, ratio control and others. Signal Characterizer Block Characterizes or approximates any function that defines an input/output relationship by configuring up to twenty X, Y coordinates. The block interpolates an output value for a given input value using the curve defined by the configured coordinates. Integrator Bock Compares the integrated or accumulated value from one or two variables to pre-trip and trip limits and generates discrete output signals when the limits are reached. This block is useful for calculating total flow, total mass, or volume over time. 5

Output Splitter Block Splits the output of one PID or other control block so that the PID will control two valves or other actuators. Control Selector Block Selects one of up to three inputs (highest, middle, or lowest) that are normally connected to the outputs of PID or other control function blocks. Block Execution Time Resource - Transducer - LCD Block - Analog Input 1, 2 20 milliseconds PID with Auto-tune 25 milliseconds Input Selector 20 milliseconds Arithmetic 20 milliseconds Signal Characterizer 20 milliseconds Integrator 20 milliseconds Output Splitter 20 milliseconds Control Selector 20 milliseconds Fully Compensated Mass Flow Block (Option Code H01) Calculates fully compensated mass flow based on differential pressure with external process pressure and temperature measurements over the fieldbus segment. Configuration for the mass flow calculation is easily accomplished using the Rosemount 3095 Engineering Assistant. FOUNDATION fieldbus Diagnostics Suite (Option Code D01) 3051S FOUNDATION fieldbus Diagnostics provide Abnormal Situation Prevention (ASP) indication and enhanced EDDL graphic displays for easy visual analysis. The integral statistical process monitoring (SPM) technology calculates the mean and standard deviation of the process variable 22 times per second and makes them available to the user. The 3051S ASP algorithm uses these values and highly flexible configuration options for customization to detect many user-defined or application specific abnormal situations (e.g. plugged impulse line detection). Process Temperature Limits Direct Mount Electronics 40 to 450 F (40 to 232 C) Remote Mount Electronics 148 to 850 F ( 100 to 454 C) (1) Electronics Temperature Limits Ambient 40 to 185 F ( 40 to 85 C) With Integral Mount LCD Display: 4 to 175 F ( 20 to 80 C) Storage 50 to 230 F ( 46 to 110 C) With Integral Mount LCD Display: 40 to 185 F ( 40 to 85 C) Pressure Limits (2) Direct Mount Electronics Pressure retention per ANSI B16.5 600# or DIN PN Static Pressure Limits Range 1A: Operates within specification between static line pressures of 0.5 psia to 2000 psig (0.03 to 138 bar) Ranges 2A 3A: Operates within specifications between static line pressures of 0.5 psia and 3626 psig (0.03 bar-a to 250 bar-g) Burst Pressure Limits Coplanar or traditional process flange 10000 psig (689,5 bar). Overpressure Limits Flowmeters withstand the following limits without damage: Range 1A: 2000 psig (138 bar) Ranges 2A 3A: 3626 psig (250 bar) TABLE 1. Overpressure Limits (1) Standard Type Humidity Limits 0 100% relative humidity Carbon Steel Rating Stainless Steel Rating ANSI/ASME Class 150 285 (20) 275 (19) ANSI/ASME Class 300 740 (51) 720 (50) ANSI/ASME Class 600 1480 (102) 1440 (99) At 100 F (38 C), the rating decreases with increasing temperature. DIN PN 10/40 580 (40) 580 (40) DIN PN 10/16 232 (16) 232 (16) DIN PN 25/40 580 (40) 580 (40) At 248 F (120 C), the rating decreases with increasing temperature. (1) Carbon Steel and Stainless Steel Ratings are measured in psig (bar). Turn-On Time Performance within specifications less than 2 seconds (typical) after power is applied to the transmitter Damping Analog output response to a step input change is user-selectable from 0 to 60 seconds for one time constant. This software damping is in addition to sensor module response time Failure Mode Alarm HART 4-20mA (output option codes A and B) If self-diagnostics detect a gross transmitter failure, the analog signal will be driven offscale to alert the user. Rosemount standard (default), NAMUR, and custom alarm levels are available (see Table 2). High or low alarm signal is software-selectable or hardware-selectable via the optional switch (option D1). (1) Bolt Material code G must be provided. (2) Static pressure selection may effect pressure limitations. 6

Rosemount Integral Orifice TABLE 2. Alarm Configuration High Alarm Low Alarm Default 21.75 ma 3.75 ma NAMUR compliant (1) 22.5 ma 3.6 ma Custom levels (2)(3) 20.2-23.0 ma 3.6-3.8 ma (1) Analog output levels are compliant with NAMUR recommendation NE 43, see option codes C4 or C5. 3051S SIS Safety Transmitter Failure Values Safety accuracy: 2.0% (1) Safety response time: 1.5 seconds (1) A 2% variation of the transmitter ma output is allowed before a safety trip. Trip values in the DCS or safety logic solver should be derated by 2%. (2) Low alarm must be 0.1 ma less than low saturation and high alarm must be 0.1 ma greater than high saturation. (3) Not available with the 3051S SIS Safety Transmitter. Dynamic Performance Total Response Time (Td + Tc) (3) : 3051S_C, Ranges 2A - 3A: Range 1A: 4-20 ma (HART ) (1) Fieldbus protocol (2) Typical Transmitter Response Time 100 milliseconds 255 milliseconds 152 milliseconds 307 milliseconds Transmitter Output vs. Time Process Variable Response Time 3051S SIS, Ranges 2A - 3A: Range 1A: 220 milliseconds 375 milliseconds Not Applicable Not Applicable Dead Time (Td) (4) 45 milliseconds (nominal) 97 milliseconds Update Rate 3051S 3051S SIS 22 times per second 11 times per second 22 times per second Not Applicable Pressure Released T d 100% 36.8% 0% T c Time T d = Dead Time T c = Time Constant Response Time = T d +T c 63.2% of Total Step Change 3051-3051_17A (1) Dead time and update rate apply to all models and ranges; analog output only (2) Transmitter fieldbus output only, segment macro-cycle not included. (3) Nominal total response time at 75 F (24 C) reference conditions. For option code DA1, add 40 milliseconds (nominal) to 4-20 ma (HART ) total response time values. (4) For option code DA1, dead time (Td) is 85 milliseconds (nominal). 7

Installation Considerations Pipe Orientation Process (1) Orientation/ Flow Direction Gas Liquid Steam Horizontal D/R D/R D/R Vertical Up R R R Vertical Down R NR NR (1) D = Direct mount acceptable (recommended) R = Remote mount acceptable NR = Not recommended Flowmeter Orientation 30 Gas (Horizontal) Liquid and Steam (Horizontal) 120 Gas (Vertical) 120 30 30 30 4686-38-490000-999 4686-38-490001-999 Physical Temperature Measurement Remote RTD 100 Ohm platinum with 1 /2-in. NPT nipple and union (078 series with Rosemount 644 housing) Standard RTD cable is shielded armored cable, length is 12 feet (3.66 m) Thermowell with Remote RTD with 1 /2-in. SST weld couplet Electrical Considerations 1 /2 14 NPT, G 1 /2, and CM20 conduit. HART interface connections permanently fixed to terminal block Material of Construction Orifice Plate 316/316L SST Hastelloy C-276 Monel 400 Body 316 SST (CF8M), material per ASTM A351 Hastelloy C-276 (CW12MW), material per ASTM A494 Flange and Pipe Material (If Applicable) A312 Gr 316/316L, B622 UNS N10276 Flange pressure limits are per ANSI B16.5 Flange face finish per ANSI B16.5, 125 to 250 RMS Body Bolts/Studs ASTM A193 Gr B8M studs SAE J429 Gr 8 bolts (meets or exceeds ASTM A193 B7 requirements) for body bolt/stud material option code G for high temperatures. Transmitter Connection Studs ASTM A193 Gr B8M studs Gaskets/O-rings Glass filled Teflon (PTFE) Optional high temperature Inconel X-750 Gaskets and o-rings must be replaced each time the 3051SFP is disassembled for installation or maintenance. Orifice Type Square edged orifice bore size Liquid (Vertical) 360 Flow 4686-38-490002-999 0.066-in and larger Quadrant edged orifice bore size (for 1 /2-in. line size only) 0.034-in 0.020-in 0.014-in 0.010-in 360 Flow 4686-38-490003-999 NOTE Integral orifice bodies contain corner tapped pressure ports. 8

Rosemount Integral Orifice Pipe Lengths Upstream and downstream associated piping sections are available on the 3051SFP. The table below lists the standard overall length (lay length) as a function of end connections and line size. Flanged Process (1) (2) (3) Connection 1 /2-in. (15 mm) Line Size 1-in. (25 mm) 1 1 /2-in. (40 mm) RF, ANSI Class 150, slip-on 18.2 (463) 28.9 (734) 40.3 (1023) RF, ANSI Class 300, slip-on 18.2 (463) 28.9 (734) 40.3 (1023) RF, ANSI Class 600, slip-on 18.2 (463) 28.9 (734) 40.3 (1023) RF, DIN PN16, slip-on 18.2 (463) 28.9 (734) 40.3 (1023) RF, DIN PN40, slip-on 18.2 (463) 28.9 (734) 40.3 (1023) RF, DIN PN100, slip-on 18.2 (463) 28.9 (734) 40.3 (1023) RF, ANSI Class 150, weld-neck 21.8 (554) 33.2 (843) 44.9 (1140) RF, ANSI Class 300, weld-neck 22.2 (559) 33.7 (856) 45.5 (1156) RF, ANSI Class 600, weld-neck 22.8 (579) 34.3 (871 46.1 (1171) RTJ, ANSI Class 150, slip-on 18.2 (463) 28.9 (734) 40.3 (1023) RTJ, ANSI Class 300, slip-on 18.2 (463) 28.9 (734) 40.3 (1023) RTJ, ANSI Class 600, slip-on 18.2 (463) 28.9 (734) 40.3 (1023) NPT / Beveled Process 18 (457) 28.9 (734) 40.3 (1023) Connection (1)(2)(3) (1) See the ordering information for model code description. (2) Consult factory for other lengths. (3) See page 36 for additional information on associated pipe lengths. Weight The following weights are approximate Line Size With Body With Flanged Piping (1) lb kg lb kg 1 /2-in. (15 mm) 13.6 6.2 17.6 8.0 1-in. (25 mm) 15.6 7.1 21.6 9.8 1 1 /2-in. (40 mm) 17.6 8.0 34.6 15.7 (1) As supplied with standard lengths, ANSI Class 150 flanges. Process-Wetted Parts Integral Manifolds 316 SST Hastelloy C-276 Remote Manifolds 316 SST Hastelloy C-276 Transmitter Vent Valves and Process Flanges 316 SST Hastelloy C-276 Process Isolating Diaphragms 316L SST Hastelloy C-276 O-rings Glass-filled TFE / Inconel X-750 Integral Manifold O-Rings Teflon (PTFE) / Graphite (D7) Non-Wetted Parts Sensor Module Fill Fluid Silicone oil Inert Fill optional Cover O-rings Buna-N Remote Mounting Brackets SST Sensor mounting (including nuts, bolts, and gasket) SST (CS optional for high temperature) Electronic Housing Low copper aluminum, NEMA 4x, IP65 SST (optional) Paint Polyurethane Bolts CS SST 9

PRODUCT CERTIFICATIONS Approved Manufacturing Locations Rosemount Inc. Chanhassen, Minnesota USA Emerson Process Management GmbH & Co. Wessling, Germany Emerson Process Management Asia Pacific Private Limited Singapore Beijing Rosemount Far East Instrument Co., LTD Beijing, China European Directive Information The EC declaration of conformity for all applicable European directives for this product can be found at www.rosemount.com. A hard copy may be obtained by contacting an Emerson Process Management representative. ATEX Directive (94/9/EC) Emerson Process Management complies with the ATEX Directive. European Pressure Equipment Directive (PED) (97/23/EC) Models 3051S_CA4; 3051S_CD2, 3, 4, 5; (also with P9 option) Pressure Transmitters QS Certificate of Assessment - EC No. PED-H-20, Module H Conformity Assessment All other Model 3051S Pressure Transmitters Sound Engineering Practice Transmitter Attachments: Diaphragm Seal - Process Flange - Manifold Sound Engineering Practice Primary Elements, Flowmeter See appropriate Primary Element QIG Electro Magnetic Compatibility (EMC) (89/336/EEC) All Models: EN 50081-1: 1992; EN 50082-2:1995; EN 61326-1:1997 Industrial Ordinary Location Certification for FM As standard, the transmitter has been examined and tested to determine that the design meets basic electrical, mechanical, and fire protection requirements by FM, a nationally recognized testing laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA). Hazardous Locations Certifications North American Certifications FM Approvals E5 Explosion-proof for Class I, Division 1, Groups B, C, and D; dust-ignition proof for Class II and Class III, Division 1, Groups E, F, and G; hazardous locations; enclosure Type 4X, conduit seal not required when installed according to Rosemount drawing 03151-1003. I5/IE Intrinsically Safe for use in Class I, Division 1, Groups A, B, C, and D; Class II, Division 1, Groups E, F, and G; Class III, Division 1; Class I, Zone 0 AEx ia IIC when connected in accordance with Rosemount drawing 03151-1006; Non-incendive for Class I, Division 2, Groups A, B, C, and D Enclosure Type 4X For entity parameters see control drawing 03151-1006. Canadian Standards Association (CSA) E6 Explosion-proof for Class I, Division 1, Groups B, C, and D; Dust-Ignition-Proof for Class II and Class III, Division 1, Groups E, F, and G; suitable for Class I, Division 2, Groups A, B, C, and D, when installed per Rosemount drawing 03151-1013, CSA Enclosure Type 4X; conduit seal not required. I6/IF Intrinsically Safe for Class I, Division 1, Groups A, B, C, and D when connected in accordance with Rosemount drawings 03151-1016; For entity parameters see control drawing 03151-1016. European Certifications I1/IA ATEX Intrinsic Safety Certificate No.: BAS01ATEX1303X EEx ia IIC T5 (-60 C T a 40 C) T4 (-60 C T a 70 C) T4 (-60 C T a 40 C) (FISCO) 1180 TABLE 3. Input Parameters Loop / Power U i = 30 V U i = 17.5 V I i = 300 ma I i = 380 ma P i = 1.0 W P i = 1.3 W P i = 5.32 W C i = 30 nf C i = 11.4 nf C i = 0 L i = 0 L i = 60 µh II 1G Groups HART / FOUNDATION fieldbus/ Remote Display / SIS FISCO HART / FOUNDATION fieldbus/ Remote Display / SIS FISCO HART / Remote Display / SIS FOUNDATION fieldbus FISCO SuperModule Platform HART / SIS FOUNDATION fieldbus / Remote Display / FISCO HART / FOUNDATION fieldbus/ SIS / FISCO Remote Display Special conditions for safe use (x) 1. The apparatus, excluding the Types 3051 S-T and 3051 S-C (In-line and Coplanar SuperModules respectively), is not capable of withstanding the 500V test as defined in Clause 6.4.12 of EN 50020. This must be considered during installation. 2. The terminal pins of the Types 3051 S-T and 3051 S-C must be protected to IP20 minimum. 10

Rosemount Integral Orifice N1 ND E1 ATEX Type n Certificate No.: BAS01ATEX3304X II 3 G EEx nl IIC T5 (T a = -40 C TO 70 C) Ui = 45 Vdc max IP66 Special conditions for safe use (x) The apparatus is not capable of withstanding the 500V insulation test required by Clause 9.1 of EN 50021: 1999. This must be taken into account when installing the apparatus. ATEX Dust Certificate No.: BAS01ATEX1374X II 1 D T105 C (-20 C T amb 85 C) V max = 42.4 volts max A = 24 ma IP66 1180 Special conditions for safe use (x) 1. The user must ensure that the maximum rated voltage and current (42.4 volts, 22 milliampere, DC) are not exceeded. All connections to other apparatus or associated apparatus shall have control over this voltage and current equivalent to a category ib circuit according to EN 50020. 2. Cable entries must be used which maintain the ingress protection of the enclosure to at least IP66. 3. Unused cable entries must be filled with suitable blanking plugs which maintain the ingress protection of the enclosure to at least IP66. 4. Cable entries and blanking plugs must be suitable for the ambient range of the apparatus and capable of withstanding a 7J impact test. 5. The 3051S must be securely screwed in place to maintain the ingress protection of the enclosure. ATEX Flameproof Certificate No.: KEMA00ATEX2143X II 1/2 G EEx d IIC T6 (-50 C T amb 65 C) EEx d IIC T5 (-50 C T amb 80 C) V max = 42.4V 1180 Special conditions for safe use (x) This device contains a thin wall diaphragm. Installation, maintenance and use shall take into account the environmental conditions to which the diaphragm will be subjected. The manufacturer s instructions for installation and maintenance shall be followed in detail to assure safety during its expected lifetime. The Model 3051S pressure transmitter must include a Series 300S housing integrally mounted to a Series Model 3051S Sensor module as per Rosemount drawing 03151-1023. Japanese Certifications E4 JIS Flameproof Ex d IIC T6 Australian Certifications E7 Certificate TC15682 TC15683 TC15684 TC15685 TC15686 TC15687 TC15688 TC15689 TC15690 Description Coplanar with Junction Box Housing Coplanar with PlantWeb Housing Coplanar with PlantWeb Housing and LCD Display In-Line SST with Junction Box Housing In-Line Hastelloy with Junction Box Housing In-Line SST with PlantWeb Housing In-Line Hastelloy with Plantweb Housing In-Line SST with Plantweb Housing and LCD Display In-Line Hastelloy with PlantWeb Housing and LCD Display SAA Explosion-proof and DIP Certification No.: AUS Ex 3798X Ex d IIC T6 (T a = 60 C) IP66 DIP A21 TA T6 (T a = 60 C) IP66 Special conditions for safe use (x) 1. It is a condition of manufacture that each transmitter module shall be pressure tested in accordance with clause 4.3 of AS 2380.2 at minimum pressure of 1450 kpa. As the model 300S housing passed tests at 4 times the reference pressures (400 kpa for single and 3800 kpa for dual compartment housing) and are not of welded construction, they may be exempted from the routing pressure test of clause 4.3 of AS 2380.2. 2. It is a condition of manufacture that each transmitter module and housing combination shall be subjected to a routine high voltage test in accordance with clause 6.2 of AS 2380.1, with the following variation. The test voltage applied to each single or dual compartment housing shall not be less than 500 V, 47 to 62 Hz, for a period of not less than one minute, with a breakdown current of less than 5 ma. 3. It is a condition of safe use that each housing shall be connected to external circuits via suitable conduit or Standards Australia certified cable glands. Where only one entry is used for connection to external circuits, the unused entry shall be closed by means of the blanking plug supplied by the equipment manufacturer or by a suitable Standards Australia certified blanking plug. 4. It is a condition of safe use that a dielectric strength test shall be applied whenever the terminal block is changed or replaced in either the dual compartment or single compartment housings. The breakdown current shall be less than 5 ma, when 500 V, 47 to 62 Hz, is applied for one minute. Note: if tested with an optional T1 transient protector terminal block fitted, the protection will operate and hence there will be no current indicated. 5. It is a condition of safe use that each transmitter module shall be used with a Model 300S housing, in order to comply with flameproof requirements. 11

6. It is a condition of safe use that each model 300S housing fitted with a transmitter module shall be marked with the same certification marking code information. Should the housing be replaced after initial supply to another model 300S housing, the replacement housing shall have the same certification marking code information as the housing it replaces. IECEx Certifications I7/IG IECEx Intrinsic Safety Certificate No.: IECExBAS04.0017X Ex ia IIC T5 (T a = -60 C to 40 C) -HART/SIS/Remote Meter Ex ia IIC T4 (T a = -60 C to 70 C) -HART/SIS/Remote Meter Ex ia IIC T4 (T a = -60 C to 70 C) -FOUNDATION Fieldbus Ex ia IIC T4 (T a = -60 C to 40 C) -FISCO IP66 TABLE 4. Input Parameters Loop / Power U i = 30 V U i = 17.5 V I i = 300 ma I i = 380 ma P i = 1.0 W P i = 1.3 W P i = 5.32 W C i = 30 nf C i = 11.4 nf C i = 0 L i = 0 Groups HART / FOUNDATION fieldbus/ Remote Display / SIS FISCO HART / FOUNDATION fieldbus/ Remote Display / SIS FISCO HART / Remote Display / SIS FOUNDATION fieldbus FISCO SuperModule Platform HART / SIS FOUNDATION fieldbus / Remote Display / FISCO HART / FOUNDATION fieldbus/ SIS / FISCO N7 IECEx Type n Certificate No.: IECExBAS04.0018X Ex nc IIC T5 (Ta = -40 C to 70 C) Ui = 45 Vdc MAX IP66 Special conditions for safe use (x) The apparatus is not capable of withstanding the 500 V insulation test required by Clause 8 of IEC 79-15: 1987. Combinations of Certifications Stainless steel certification tag is provided when optional approval is specified. Once a device labeled with multiple approval types is installed, it should not be reinstalled using any other approval types. Permanently mark the approval label to distinguish it from unused approval types. K1 Combination of E1, I1, N1, and ND K5 Combination of E5 and I5 K6 Combination of E6 and I6 K7 Combination of E7, I7, and N7 KA Combination of E1, I1, E6, and I6 KB Combination of E5, I5, I6 and E6 KC Combination of E5, E1, I5 and I1 KD Combination of E5, I5, E6, I6, E1, and I1 Special conditions for safe use (x) 1.The Models 3051S HART 4-20mA, 3051S Fieldbus, 3051S Profibus and 3051S FISCO are not capable of withstanding the 500V test as defined in clause 6.4.12 of IEC 60079-11. This must be taken into account during installation. 2.The terminal pins of the Types 3051S-T and 3051S-C must be protected to IP20 minimum. 12

Rosemount Integral Orifice DIMENSIONAL DRAWINGS Rosemount 3051SFP Proplate Flowmeter Front View Bottom View Side View 8.8 (223.46) 11.73 (297.22) 7.7 (195.51)) B.D. (2) Flow 5.3 (134.14) K (1) Downstream J Upstream Dimensions are in inches (millimeters). Line Size Dimension 1 /2-in. (12.7 mm) 1-in. (25.4 mm) 1 1 /2-in. (38.1 mm) J (RF slip-on, RTJ slip-on, RF-DIN slip-on) 12.4-in. 318 mm 20.2-in. 513 mm 28.4-in. 721 mm J (RF 150#, weld-neck) 14.3-in. 363 mm 22.3-in. 566 mm 30.7-in. 780 mm J (RF 300#, weld-neck) 14.5-in. 368 mm 22.6-in. 574 mm 31.0-in. 787 mm J (RF 600#, weld-neck) 14.8-in. 376 mm 22.9-in. 582 mm 31.3-in. 795 mm K ((RF slip-on, RTJ slip-on, RF-DIN slip-on) (1) 5.7-in. 148 mm 8.7-in. 221 mm 11.9-in. 302 mm K (RF 150#, weld-neck) 7.5-in. 191 mm 10.9-in. 277 mm 14.2-in. 361 mm K (RF 300#, weld-neck) 7.7-in. 196 mm 11.1-in. 282 mm 14.5-in. 368 mm K (RF 600#, weld-neck) 8.0-in. 203 mm 11.4-in. 290 mm 14.8-in. 376 mm B.D. (2) 0.664-in. 16.9 mm 1.097-in. 27.86 mm 1.567-in. 39.80 mm (1) Downstream length shown here includes plate thickness of 0.162-in. (4.11 mm). (2) B.D is diameter of the precision bored portion of the upstream and downstream piping. 13

ORDERING INFORMATION Rosemount 3051SFP Proplate Flowmeter Ordering Information Model 3051SFP Code D Code Product Description Proplate Flowmeter Measurement Type Differential Pressure Body Material S 316 SST H Hastelloy C-276 Code Line Size 005 1 /2-in. (15 mm) 010 1-in. (25 mm) 015 1 1 /2-in. (40 mm) Code Process Connection T1 NPT Female Body (not available with remote thermowell and RTD) S1 (1) Socket Weld Body (not available with remote thermowell and RTD) P1 Pipe Ends: NPT threaded P2 Pipe Ends: Beveled A1 Pipe Ends: Flanged, RF, ANSI Class 150, slip-on A3 Pipe Ends: Flanged, RF, ANSI Class 300, slip-on A6 Pipe Ends: Flanged, RF, ANSI Class 600, slip-on D1 Pipe Ends: Flanged, RF, DIN PN16, slip-on D2 Pipe Ends: Flanged, RF, DIN PN40, slip-on D3 Pipe Ends: Flanged, RF, DIN PN100, slip-on W1 Pipe Ends: Flanged, RF, ANSI Class 150, weld-neck W3 Pipe Ends: Flanged, RF, ANSI Class 300, weld-neck W6 Pipe Ends: Flanged, RF, ANSI Class 600, weld-neck R1 Pipe Ends: Flanged, RTJ, ANSI Class 150, slip-on R3 Pipe Ends: Flanged, RTJ, ANSI Class 300, slip-on R6 Pipe Ends: Flanged, RTJ, ANSI Class 600, slip-on P9 Special process connections Code Orifice Plate Material S 316 SST H Hastelloy C-276 M Monel Code Bore Size Option 0010 0.010-in. (0.25 mm) for 1 /2-in. pipe 0014 0.014-in. (0.36 mm) for 1 /2-in. pipe 0020 0.020-in. (0.51 mm) for 1 /2-in. pipe 0034 0.034-in. (0.86 mm) for 1 /2-in. pipe 0066 0.066-in. (1.68 mm) for 1 /2-in. pipe 0109 0.109-in. (2.77 mm) for 1 /2-in. pipe 0160 (2) 0.160-in. (4.06 mm) for 1 /2-in. pipe 0196 (2) 0.196-in. (4.98 mm) for 1 /2-in. pipe 0260 (2) 0.260-in. (6.60 mm) for 1 /2-in. pipe 0340 (2) 0.340-in. (8.64 mm) for 1 /2-in. pipe 0150 0.150-in. (3.81 mm) for 1-in. pipe 0250 (2) 0.250-in. (6.35 mm) for 1-in. pipe 0345 (2) 0.345-in. (8.76 mm) for 1-in. pipe 0500 (2) 0.500-in. (12.70 mm) for 1-in. pipe 0630 (2) 0.630-in. (16.00 mm) for 1-in. pipe 0800 0.800-in. (20.32 mm) for 1-in. pipe 0295 0.295-in. (7.49 mm) for 1 1 /2-in. pipe 14

Rosemount Integral Orifice Rosemount 3051SFP Proplate Flowmeter Ordering Information 0376 (2) 0.376-in. (9.55 mm) for 1 1 /2-in. pipe 0512 (2) 0.512-in. (13.00 mm) for 1 1 /2-in. pipe 0748 (2) 0.748-in. (19.00 mm) for 1 1 /2-in. pipe 1022 1.022-in. (25.96 mm) for 1 1 /2-in. pipe 1184 1.184-in. (30.07 mm) for 1 1 /2-in. pipe Code Electronics Connection Platform D3 Direct-mount, 3-valve manifold, SST D4 Direct-mount, 3-valve manifold, Hastelloy-C D5 Direct-mount, 5-valve manifold, SST D6 Direct-mount, 5-valve manifold, Hastelloy-C D7 Direct-mount, High Temperature, 5-valve manifold, SST R3 Remote-mount, 3-valve manifold, SST R4 Remote-mount, 3-valve manifold, Hastelloy-C R5 Remote-mount, 5-valve manifold, SST R6 Remote-mount, 5-valve manifold, Hastelloy-C Code 1A 2A 3A Differential Pressure Range 0 to 25 in H 2 O (0 to 62.2 mbar) 0 to 250 in H 2 O (0 to 623 mbar) 0 to 1000 in H 2 O (0 to 2.5 bar) Code Output Protocol A 4 20 ma with digital signal based on HART protocol B (3) 4 20 ma Safety Certified with digital signal based on HART protocol F (4) FOUNDATION fieldbus: AI block, Link Master, Input Selector Block Code Electronics Housing Style Material Conduit Entry Size 1A PlantWeb Housing Aluminum 1 /2-14 NPT 1B PlantWeb Housing Aluminum M20 x 1.5 (CM20) 1C PlantWeb Housing Aluminum G 1 /2 1J PlantWeb Housing 316L SST 1 /2-14 NPT 1K PlantWeb Housing 316L SST M20 x 1.5 (CM20) 1L PlantWeb Housing 316L SST G 1 /2 2A Junction Box Housing Aluminum 1 /2-14 NPT 2B Junction Box Housing Aluminum M20 x 1.5 (CM20) 2C Junction Box Housing Aluminum G 1 /2 2E Junction Box Housing with output for remote display and interface Aluminum 1 /2-14 NPT 2F Junction Box Housing with output for remote display and interface Aluminum M20 x 1.5 (CM20) 2G Junction Box Housing with output for remote display and interface Aluminum G 1 /2 2J Junction Box Housing 316L SST 1 /2-14 NPT 2M Junction Box Housing with output for remote display and interface 316L SST 1 /2-14 NPT 7J (5) Quick Connect (A size Mini, 4-pin male termination) 316L SST Code Performance Class 3 (6) Ultra for Flow: up to ±0.95% flow rate accuracy, 10:1 flow turndown, 10-year stability. limited 12-year warranty 1 (6) Ultra: up to ±1.05% flow rate accuracy, 8:1 flow turndown, 10-year stability, limited 12-year warranty 2 Classic: up to ±1.20% flow rate accuracy, 8:1 flow turndown, 5-year stability Code Options Transmitter / Body Bolt Material G High temperature (850 F (454 C)) (SAE J429 Gr8 / Body bolts with A193 Gr B8M transmitter studs) Temperature Sensor T (7) Thermowell and RTD Optional Bore Calculation BC Bore Calculation Optional Connection G1 DIN 19231 Transmitter Connection 15

Rosemount 3051SFP Proplate Flowmeter Ordering Information Pressure Testing P1 (8) Hydrostatic Testing Special Cleaning P2 Cleaning for special processes PA Cleaning per ASTM G93 Level D (section 11.4) Material Testing V1 Dye Penetrant Exam Material Examination V2 Radiographic Examination (available only with Process Connection code W1, W3, and W6) Flow Calibration WD (9) Discharge Coefficient Verification WZ (9) Special Calibration Special Inspection QC1 Visual and dimensional inspection with certificate QC7 Inspection and performance certificate Material Traceability Certification Q8 (10) Material certification per ISO 10474 3.1.B and EN 10204 3.1.B Code Conformance J2 (11) ANSI / ASME B31.1 J3 (11) ANSI / ASME B31.3 J4 (11) ANSI / ASME B31.8 Materials Conformance J5 (12) NACE MR-0175 / ISO 15156 Country Certification J1 Canadian Registration J6 European Pressure Directive (PED) Transmitter Calibration Certification Q4 Calibration Data Certificate for Transmitter QP Calibration Data Certificate and Tamper Evident Seal Safety Certification QS Certificate of FMEDA Data Product Certifications E1 ATEX Flameproof I1 ATEX Intrinsically Safe N1 ATEX Type n IA (13) ATEX FISCO Intrinsically Safe; for FOUNDATION fieldbus protocol only K1 ATEX Flameproof, Intrinsically Safe, Type n, Dust (combination of E1, I1, N1, and ND) ND ATEX Dust E5 FM Explosion-proof I5 FM Intrinsic Safety, Non-incendive IE (13) FM FISCO Intrinsically Safe; for FOUNDATION fieldbus protocol only K5 FM Explosion-proof, Intrinsically Safe, Non-incendive (combination of E5 and I5) E6 CSA Explosion-proof I6 CSA Intrinsically Safe, Division 2 IF (13) CSA FISCO Intrinsically Safe; for FOUNDATION fieldbus protocol only K6 CSA Explosion-proof, Intrinsically Safe, Division 2 (combination of E6 and I6) E7 (13) SAA Flameproof, Dust Ignition-proof I7 IECEx Intrinsically Safe IG (13) IECEx FISCO Intrinsically Safe N7 IECEx Type n K7 SAA Flameproof, Dust Ignition-proof, IECEx Intrinsically Safe, and Type n (combination of E7, I7, and N7) KA ATEX and CSA Flameproof, Intrinsically Safe (combination of E1, I1, E6, and I6) Note: Only available on Housing Style codes 1A, 1J, 2A, 2J, 2E, or 2M. KB FM and CSA Explosion-proof, Intrinsically Safe, Division 2 (combination of E5, E6, I5, and I6) Note: Only available on Housing Style codes 1A, 1J, 2A, 2J, 2E, or 2M. KC FM and ATEX Explosion-proof, Intrinsically Safe, Non-incendive (combination of E5, E1, I5, and I1) Note: Only available on Housing Style codes 1A, 1J, 2A, 2J, 2E, or 2M. 16

Rosemount Integral Orifice Rosemount 3051SFP Proplate Flowmeter Ordering Information KD FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of E5, I5, E6, I6, E1, and I1) Note: Only available on Housing Style codes 1A, 1J, 2A, 2J, 2E, or 2M. Alternative Transmitter Material of Construction L1 Inert Sensor Fill Fluid L2 Graphite-filled Teflon (PTFE) o-ring LA Inert sensor fill fluid and graphite-filled Teflon (PTFE) o-ring Display (14) M5 PlantWeb LCD display M7 (6)(15) Remote mount LCD display and interface, PlantWeb housing, no cable, SST bracket M8 (6)(15) Remote mount LCD display and interface, PlantWeb housing, 50 foot cable, SST bracket M9 (6)(15) Remote mount LCD display and interface, PlantWeb housing, 100 foot cable, SST bracket Terminal Blocks T1 (14) Transient terminal block T2 (16) Terminal block with WAGO spring clamp terminals T3 (16) Transient terminal block with WAGO spring clamp terminals PlantWeb Control Functionality A01 (17) FOUNDATION fieldbus Advanced Control Function Block Suite PlantWeb Diagnostic Functionality D01 (17) FOUNDATION fieldbus Diagnostics Suite DA1 (18) HART Diagnostics Suite PlantWeb Enhanced Measurement Functionality H01 (17)(19) Fully Compensated Mass Flow Block Alarm Limits C4 (20) NAMUR alarm and saturation signal levels, high alarm C5 (20) NAMUR alarm and saturation signal levels, low alarm C6 (6)(20) Custom alarm and saturation signal levels, high alarm Note: Requires option code C1, custom software configuration. A Configuration Data Sheet must be completed, see page 38. C7 (6)(20) Custom alarm and saturation signal levels, low alarm Note: Requires option code C1, custom software configuration. A Configuration Data Sheet must be completed, see page 38. C8 (20) Low alarm (standard Rosemount alarm and saturation signal levels) Special Configuration (Hardware) D1 (20) Hardware Adjustment (zero, span, alarm, security) D4 External ground screw DA (20) Hardware adjustment (zero, span, security) and external ground screw Conduit Electrical Connector GE (21) M12, 4-pin, Male Connector (eurofast ) GM (21) A size Mini, 4-pin, Male Connector (minifast ) Typical Model Number: 3051SFP D S 010 A3 S 0150 D3 1A A 1A 3 (1) To improve pipe perpendicularity for gasket sealing, socket diameter is smaller than standard pipe O.D. (2) Best flow coefficient uncertainty is between (0.2 < < 0.6). (3) Requires PlantWeb Housing and Hardware Adjustments option code D1. (4) Requires PlantWeb housing. (5) Available with output code A only. Available approvals are FM Intrinsically Safe, Non-incendive (option code I5) or ATEX Instrinsically Safe (option code I1). Contact an Emerson Process Management representative for additional information. (6) Not available with Output Protocol code B. (7) Thermowell material is the same as the body material. (8) Does not apply to Process Connection codes T1 and S1. (9) Not available for bore sizes 0010, 0014, 0020, or 0034. (10) Includes certificates for mechanical and chemical properties of bodies, orifice plates, pipes, flanges, and adapters as applicable. (11) Not available with DIN Process Connection codes D1, D2, or D3. (12) Materials of Construction comply with metallurgical requirements within NACE MR0175/ISO for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments. (13) Consult factory for availability. 17

(14) Not available with Housing code 7J. (15) Not available for Output Protocol code F, Housing code 01, or option code DA1. (16) Available with Output Protocol code A and PlantWeb housing only. (17) Requires PlantWeb housing and output code F. (18) Requires PlantWeb housing and Output code A. Includes Hardware Adjustments as standard. Contact an Emerson Process Management representative regarding availability. (19) Requires Rosemount 3095 Engineering Assistant to configure. (20) Not available with Output Protocol code F. (21) Not available with Housing code 7J. Available with Intrinsically Safe approvals only. For FM Intrinsically Safe, Non-incendive approval (option code I5) or FM FISCO Intrinsically Safe approval (option code IE), install in accordance with Rosemount drawing 03151-1009 to maintain NEMA 4X rating. 18