Marine Grounding System SEK-3. Technical Description Version 1.0 / English

Similar documents
SEK-3 Marine Grounding System

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

PEPPERL+FUCHS GmbH

Inductive slot sensor

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. General specifications. Rated operating distance s n 5 mm

Manual Isolating Barrier D461R1 (Revision 01)

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Operating Instructions Edition 02/2007

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Sensor module. Operating instructions. Sensor module, Type 17-51P2-... Document No P2-7D0001 Version: 17 May 2011/Rev. 0

Technical Data. Dimensions

SET-2000 Oil/Sludge 12 VDC

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Manual Isolating Barrier D461 (Revision 05)

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

EU DECLARATION OF CONFORMITY

IECEx Certificate of Conformity

AND INSTALLATION MANUAL

Technical Data. Dimensions

Safety instructions VEGAPULS 64

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

OPTIBAR DP 7060 Supplementary Instructions

Ultrasonic Level Measurement nivopuls FDU 10 S

Operating Manual MS220KA and MSR220KA

PESO. Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

4) Intrinsic Safety Certification

DICTATOR Hold-Open Systems for Hazardous Areas

SET Installation and Operating Instructions. Level switch for one sensor

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Certificate of Compliance

DB5 Intrinsically Safe Sounder Type DB-5

Operating Manual MS220Vi and MSR220Vi

OPTIBAR P 1010/2010 C Supplementary instructions

SET-2000 Hi Level/Oil

FAHM Co. Temperature Transmitter PTT74 Series

D SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410

FDOOT241-A9-Ex Multisensor fire detector

SCHMIDT LED Measured Value Display MD Instructions for Use

INSTRUCTION MANUAL (ATEX)

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Declaration of conformity

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

Operating Manual MS220DA

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

Certificate of Compliance

Temperature Sensor TRG Original Installation Instructions English

Intrinsically safe acoustic emission equipment opens the door to permanent monitoring applications in the oil and gas industry

Universal Tank Alarm Type Installation, Operation & Maintenance

TECHNICAL BULLETIN [ 1 / 10 ]

ASSURIX Intrinsically Safe Photoelectronic Sensors

GROUNDING MONITORING DEVICES AND SYSTEMS

VERSAFLOW VORTEX Supplementary instructions

PROFIBUS-PA Display RID 261 PROFIBUS-PA

Electrical Installations Design, Selection, Erection and Inspection

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Installation and Operating Instruction

GESTRA Steam Systems LRG English. Installation Instructions Conductivity Electrode

Continuous Gas Analyzers AO2000 Series AO2040-CU Ex Central Unit in Category 2G. Operator s Manual 42/24-13 EN Rev. 3

MANUAL Oil Level Sensor

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

OOH740-A9-Ex Multisensor fire detector

1.7. Insulation fault evaluators EDS460/490 EDS461/491

OilSET-1000 (12 VDC)

M LLET. Silo pressure detector. Füllstandtechnik. Operating instructions. 1. Description. 1.5 Dimensions. 1.1 Intended use. 1.

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

GMA200-MW16. Operation Manual. Gas detection controller for wall mounting

PROTECT SRB 200EXi-1A

Fieldbus Non-Incendive Concept takes FISCO into Zone 2 and Division 2 hazardous areas. Phil Saward

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Air Sensor. SAC Ex FCS Ex. Manual ATEX. AQ M-Tech AB

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

Physikalisch-Technische Bundesanstalt

Operating Manual MS220VA and MSR220VA

Gas cylinder scale Model GCS-1

ATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X

Annubar Flowmeter Series

OPTIWAVE X500 Supplementary Instructions

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Survey of electrical equipment installed in hazardous areas on tankers

Manual Power relay SR853

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

User s Manual YTA610 and YTA710 NEPSI Certification

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

Ex Products Highest level of safety under the most difficult conditions

Transcription:

Version.0 / English Updated: November 206

and Accessories To be certified for use in gas hazardous areas of zone according to European Directive EN 204/34/EU (ATEX). The explosion-proof Marine Grounding System type SEK-3 ensures the safe and monitored equalization of a voltage difference between ship and shore that occurs during filling processes of petrochemical, chemical or other products. Functional Principle The danger of equalization currents between vessels and loading bay occurs by electro-chemical processes, independently of the filling. The ship, the metal construction of the loading bay and the water as electrolyte in between form a galvanic cell (see Figure ). Between the electrodes of this cell a voltage difference exists. Any conductive connection between the electrodes will lead to an indefinite electrical current flow. A current flow can cause hotspots at connection points and build sparks while disconnecting inductive elements. These sparks could cause a fatal ignition in hazardous areas. The effect of a voltage difference takes place as soon as the ship is berthed, and not only during loading and unloading. Figure : Battery effect To prevent such unregulated current flow, different guidelines for tank ships and terminals specify to insulate the ship from the shore electrically. Typically, non-conductive flanges are used to insulate ships from the shore, to take the physical effect into consideration. However, there are still risks of a conductive connection might be created by mistake or by chance, e.g. at gangways, with metal ropes and tools. This risk consists in total operating time of the terminal and over a variety of ship loading processes. Regarding this aspect, the insulating by means of flanges as only safety procedure establishes no sufficient safety conditions. A high-conductive and monitored voltage equalization bonding line such as a marine grounding system is recommended. A marine grounding system is an effective risk reduction and explosion protection method in addition to the flange insulating. The ensures a higher level of safety at ship and shore. 2 (9)

2 Application The Marine Grounding System is attached to the ship, using the special Marine Grounding Clamp SKS-4A, directly after the vessel has berthed and before any loading equipment is mounted. The potential difference between ship and shore will be reduced by the conductive bonding line. As long as safe conditions are detected, the signal light at the Marine Grounding System shows status green (see Figure 2). The impact of errors in handling and operating with metal equipment on board or on the loading bay will not create a hazardous situation. In case of an unintended loosening of the clamp or any change of the electrical conditions between ship and shore apart from safe specification, the will immediately interrupt the bonding connection. Any remaining or induced voltage difference at the cable will be dissipated securely inside the system and kept away from the connection point at the ship. As long as safe conditions are not detected, the signal light at the marine grounding system shows status red. Before and during contacting the Marine Grounding Clamp, the connection to the voltage equalization inside the control system remains interrupted. This ensures that the electrical conductive bonding line connection between ship and shore is released, when a proper mechanical an electrical contracting is monitored. Another monitoring function of the ensures the recognition of active voltage sources around (e.g. an active cathodic corrosion protection system). The monitored voltage of the object itself and more monitoring functions of internal control functions display failure status and activate external alarm signals in case of any fault. Figure 2: Connected Marine Grounding Clamp 3 (9)

3 Adequacy of the Marine Grounding System Conventional grounding control devices or simple voltage-equalization bonding lines are not suitable for the described case. Using an electrical conductive connection between ship and shore without monitoring functions can be dangerous and should not be considered. Grounding control devices, which ensure the controlled discharge of electrostatics occurring during filling processes to road trucks or railway tank wagons, come up with a high-ohmic bonding line and clamp contact. While an effective voltage equalization between ship and shore takes place in mω range, for discharging electrostatics 06 Ω are sufficient. In contrast to the Marine Grounding System SEK-3 a grounding control device is in a conductive state during attaching. The internal contacts of the Marine Grounding System are engineered for extra high currentvoltage-resistance. If the limit will be exceeded, the connection will be automatically interrupted. The Marine Grounding System has a compulsive interruption system of the voltage equalization line that comes in operation when the clamp is connected incorrectly or before pull off (e.g. loosening by force). Figure 3: Tank farm with ship loading and unloading 4 (9)

4 Special Features of the Marine Grounding System 4. Compliance to European standard The is designed in full compliance to the newest editions of European ATEX and EMC Standards. It will be approved as electrical device of category II 2 G for use in hazardous areas of zone. 4.2 Intelligent Explosion Protection Timm Elektronik s special explosion protection concept combines protection by intrinsic safety, increased safety and powder filling. With this combination of protection types the Marine Grounding System can be opened in gas hazardous areas for configuration and to see the System Information Display. The construction and selection of the components under the aspect of explosion protection increases the reliability of the SEK-3. 4.3 Special Marine Grounding Clamp The includes the complete newly developed Marine Grounding Clamp SKS-4A. It is made of high sturdy stainless steel. The fastening handle design allows to attach the clamp with low force. The limit switch evaluation of the flexible clamping jaws and the contact resistance measurement enables the safe detection of proper clamp attachment. The design of the clamp guarantees a very reliable electrical and mechanical connection. When the clamp is tightened and a proper connection is detected, the Marine Grounding System indicates this at its front and by electronic outputs. To improve usability, the SEK-3 features a special grounding clamp with additional status LEDs. The operator at the attachment point gets informed directly whether the clamp is attached properly or in need for retightening. This is also important in particular to the large distance between the installed Marine Grounding System and the contact patch for the grounding clamp at the ship. 4.4 High-conductive Marine Grounding Cable A safe voltage equalization and measure line between ship and shore is ensured by a very low-ohmic, multi-wired Marine Grounding Cable. The Cable is available up to a length of 30 meters. 4.5 Bright signal lights at the device front Two clearly visible signal lights at the front of the SEK-3 housing indicate the operational status widely. The signal lights stand out of the housing front, so that they are still clearly visible by a view from side and from a high distance range. 5 (9)

4.6 Monitoring functions and System Information Display The control device implements several intern and extern monitoring and measuring functions that enable a safe and effective operation. The intern monitoring reviews the correct functions of safety relevant circuit areas. The evaluation of extern signals is also subject to consequent plausibility checks. The low-ohmic bonding line is permanent monitored during operation. Detailed status information is available inside the housing at a system information display, that enables an effective diagnosis, e.g. for error diagnosis. 4.7 Control and Signal Outputs For integration of the Marine Grounding System to the automatic control system of the filling, the SEK-3 comes with voltage-free contact outputs and electronic signal outputs in accordance to the NAMUR-standard. 2 contact release output electronic release output configurable switch contact outputs configurable electronic output alarm contact output Filling release is given by a voltage-free and internally monitored contact output or by an intrinsically safe electronic output. By integration of the Marine Grounding System to the automatic control system of the filling, a compulsory use of the Grounding System is enabled. Two configurable changing contacts, one configurable electronic output and one additional alarm contact are available. The configurable contacts can be set to indicate different operating states for evaluation at the control room. The alarm contact signals potentially unsafe situations, e.g. overvoltage or overcurrent at the bonding line, internal failures as well as a deactivated marine grounding to warn immediately and to prevent from using the system when safe conditions cannot be assured. 4.8 Area of Application The type of explosion protection makes the Marine Grounding System applicable to the gas group IIB for filling even pure Ethanol. Furthermore, with its extended temperature range from -40 C up to +60 C, the SEK-3 provides reliable operation under extreme climate conditions. 6 (9)

5 Technical Specifications 5. Operating Data Device category according to 204/34/EU II 2 G Type of protection Ex eb ib q [ib] IIB T4 Gb Protection of enclosure IP 54 Power supply In type of protection increased safety Ex eb 0, 20, 220, 230 V ± 0 %, 50-60 Hz approx. 5 VA Ambient temperature range -40 to +60 C Dimensions 380 mm, 650 mm, 245 mm (L, W, H) Weight Approx. 25 kg (without cable) 5.2 Sensor and Grounding Circuits Type of protection intrinsic Safety Ex ib Cable length 50 m (EX-specification, functional limitations must be observed) Maximum ratings Uo =,2 V, Io = 475 ma, Po =,34 W, Co and Li insignificant low 5.3 Control Output Circuits Contact outputs Type of protection increased safety Ex e Maximum ratings: 250 V AC, 3 A, 00 VA filling release contact, voltage-free closing contact alarm output, voltage-free opening contact 2 additional signal contacts, 2 voltage-free switching contacts Electronic outputs Type of protection intrisic safety Ex ib NAMUR-compatible transistor output Maximum rates: Ui = 20 V, Ii = 20 ma, Pi = 400 mw, Ci and Li insignificant low 7 (9)

5 Connection Diagram 6 8 0 8 0 3 5 7 9 2 23 2 4 6 8 20 22 24 25 26 27 28 29 30 3 32 3 Alarm K2 WR K3 4 Ausgang E2 + - Anzeige in der Tür (Aderfarben auf beiden Seiten gleich) Schalter 2 Schalter 3 LED-K grün 4 LED-K rot 5 LEDs-A 6 Vordere feste Backe 7 Hintere bew. Backe ge/gn Zangengehäuse 8-6 PA 7-25 PA PA-Zangenanschluss (Zangengehäuse) WR2 K4 9-7 + 5 Ausgang E Schiffskabel 2 RelaisKontakte ge/gn 7 9 8 0 2 6 7 9-4 (rt/bl) +3 (ws/gn) Freigabe K Kabelnr.: 2 3 5 4 6 L N PE 2 4 5-2 (ws) 3 0/220/230V 50/60Hz Versorgung + (gr/rs) 6 Vcc4.2 (vi) 5 Vcc4. (rt) 8 Vcc5 +5V(sw) 7 Vcc4.3 (bn) 9 Kat.gn (gn) 20 Kat.rot (rs) 2 SCL (ge) 22 SDA (gr) 23 GND (bl) 24 -----gr ws gn rt bl bn rs ge 0mm2 sw Der PA-Anschlussbolzen auf der Montageplatte des Systemgehäuses ist mit einer PA-Leitung von mindestens 25mm² mit dem nächstliegenden Potentialausgleichsystem zu verbinden. Alle Kabelverschraubungen M20x,5 sind für Kabel mit einem Durchmesser von 6 bis 2mm bestimmt. 8 (9)

7 International Approval The will be approved for use in potentially hazardous areas according to European standards. After final approval process, it can be brought to operation based on the mentioned certificates as single device, everywhere where the ATEX standards are valid. 8 Contact Us For technical consulting or distribution, our sales team will be available for you under the following contact data: Humboldtstr. 29 2509 Glinde - Germany Inga Klemmer Sales +49 40 248 35 63-33 klemmer@timm-elektronik.de Dr. Alexander Zelck Head of International Sales +49 40 248 35 63-32 zelck@timm-elektronik.de 9 Comment Please note that the SEK-3 currently passes the certification process. We draw attention to the fact that all values indicated are provisional datas according to the submitted approval documents. 9 (9)