Development Of A Low-Cost Heat Pump Water Heater For Residential Applications

Similar documents
Heat Pump Water Heaters: Laboratory and Field Evaluation of New Residential Products

RESULTS FROM HOUSE APPLIANCE SAFETY AND DEPRESSURIZATION TESTS CONDUCTED ON SINGLE FAMILY HOUSES UNDERGOING SOUND INSULATION

Effect Of Setup Thermostat Schedule On Heat Pump Water Heater Energy Consumption, Coefficient Of Performance And Peak Load

Energy Efficiency Potential of Heat Pump Water Heaters in Commercial Buildings

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Estimating the Level of Free Riders in the Refrigerator Buy-Back Program

Fifteen Years of Dehumidification Results from Heat Pump Water Heaters

Demand-Response Performance of Sanden Unitary/Split-System Heat Pump Water Heaters

DROP-IN EVALUATION OF REFRIGERANT 1234YF IN A RESIDENTIAL INTEGRAL HEAT PUMP WATER HEATER

Field Trial of Residential Ammonia-Water Absorption Heat Pump Water Heaters

LOW COST HEAT PUMP WATER HEATER (HPWH)

Field Evaluation of Pre-Commercial Residential Gas Heat Pump Water Heaters

Can Short Term ARRA Stimulus Funding Achieve Long Term Market Transformation? 1

Multifamily Buildings: Real World Monitored Data on Hot Water Energy and Water Use

Stock Vessels for Improved Quality and Energy Savings

Development and Field Testing of a Hybrid Water Heating and Dehumidification Appliance

Effects of Ultra-High Turndown in Hydronic Boilers By Sean Lobdell and Brian Huibregtse January 2014

Reinventing Energy Efficiency WARMNESS.

SOLAR HOT WATER AND HEAT PUMP BOOSTER ENERGY CALCULATION METHODOLOGY

ANSI/AHRI Standard 620 (I-P) 2014 Standard for Performance Rating of Self-contained Humidifiers for Residential Applications

NOVEL COMPACT SORPTION GENERATORS FOR HEAT PUMP APPLICATIONS

ASHRAE JOURNAL ON REHEAT

AN ANALYSIS OF THE PERFORMANCE OF RESIDENTIAL SMOKE DETECTION TECHNOLOGIES UTILIZING THE CONCEPT OF RELATIVE TIME

Demonstration of 2nd Generation Ducted GE "Brillion" Hybrid Water Heater in the PNNL Lab Homes

Transcritical CO2 Bottle Cooler Development

Dr. Riaan Rankin & Dr. Martin van Eldik M-Tech Industrial (Pty) Ltd / North-West University October 2010.

CONTROLLED CHILLED BEAM PUMP MODULE

Technical Assignment 3

MEMORANDUM. DATE: June 14, TO: Sponsors of the Massachusetts ENERGY STAR Appliances Program

Application of Air Source Variable Refrigerant Flow in Cold Climates

Calculated Energy Savings for Disabling Anti- Sweat Door Heat on Glass Display Case Doors

NAECA Water Heaters. Tankless (Instantaneous) < 2 gallons Natural Gas 75,000 Btu 200,000 Btu Oil 105,000 Btu 210,000 Btu Electric

2019 ETCC Webinar Series. ETCC-CA.com/webinars

NOx REDUCTION EXPERIENCE ON NATURAL GAS FIRED TURBO FURNACES

Heat Pump Water Heaters

TECHNICAL NOTE JULY Dr. Thomas Butcher Brookhaven National Laboratory Building 526, P.O. Box 5000 Upton, L. I. NY 11719

SURVEY ON THE OCCUPANT BEHAVIOR RELATING TO WINDOW AND AIR CONDITIONER OPERATION IN THE RESIDENTIAL BUILDINGS

Energy Efficiency. Intercept HDDperDay <2e 16 kwhperday

A Technical Introduction to Cool Thermal Energy Storage Commercial Applications

Case Study of an Innovative HVAC System with Integral Dehumidifier. Florida Solar Energy Center Cocoa, Florida

Numerical study of heat pipe application in heat recovery systems

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

A Dual Setpoint Controller for Combination Service Boilers

Compression of Fins pipe and simple Heat pipe Using CFD

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

Life-Cycle Energy Costs and Greenhouse Gas Emissions for Gas Turbine Power

Low Global Warming Refrigerants For Commercial Refrigeration Systems

Prescriptive Path Technical Reference Manual Version

How to Heat Water in All-Electric Homes & Apartments?

Saying Mahalo to Solar Savings: A Billing Analysis of Solar Water Heaters in Hawaii

EFFECT OF COMPACTION ON THE UNSATURATED SHEAR STRENGTH OF A COMPACTED TILL

Efficiency of Non-Azeotropic Refrigerant Cycle

DEMONSTRATION OF ADVANCED INTEGRATED HVAC&R SYSTEMS IN A LOBLAWS SUPERMARKET IN CANADA

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Evaluation of HCFC Alternative Refrigerants

A Simulation Study on the Energy Efficiency of Gas-Burned Boilers in Heating Systems

NEBRASKA MODIFIED ROOF POND: 1985 SUMMER PERFORMANCE RESULTS

Field Testing Results for Residential Gas-Fired Heat Pump Water Heaters

Performance Investigation of Indoor Air Source Heat Pump Water Heater for Canadian Winter Conditions

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

High Performance Building Guide 1

6 th Pipeline Technology Conference 2011

J. R. Qualey III, L. Desmarais, J. Pratt Simplex Time Recorder Co., 100 Simplex Drive, Westminster, MA 01441

Evaluating Domestic Water Heater Performance for NY Homes NYSERDA Agreement 15606

Softened Water Benefits Study: Energy Savings Detergent Savings. Independent studies demonstrate the link. Executive Summaries

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

ENGINEERING. Edition No. 13 October 2002

Possibilities of Heat Exchanger Use in Pigsty Ventilation Systems

Low-Income Refrigerator Replacement Selecting the Worst of the Worst

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Minimization of Mass Flow in District Heating Network Equipped with One Stage Domestic Hot Water Production Substations

Eliminating Condensation and Resulting Corrosion. Sulphur Tail Gas and De-Gas Lines

Solar thermal solutions within the Energy Labelling Context

Clemens Felsmann 1, Jean Lebrun 2, Vincent Lemort 2 and Aad Wijsman 3 ABSTRACT INTRODUCTION METHODOLOGY

Novel Press Fabric Cleaning Method Increases Productivity in a Sustainable Manner

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

Experimental Study to Evaluate Smoke Stratification and Layer Height in Highly Ventilated Compartments

Active desiccant integration with packaged rooftop HVAC equipment

March 2014 AHRI Presents Research Findings at Low-GWP AREP Conference

Heat Pump Water Heaters: A Key Energy Technology for California

Thick-Film Heater achieves Superior Performance in Thermal Response, Uniformity and Efficiency.

EVALUATING LOOP HEAT PIPE PERFORMANCE IMPROVEMENT USING CIRCUMFERENTIAL GROOVES. Nadjara dos Santos, Roger R. Riehl

Evaluation of Liquid Water Content in Thermal Efficient Heating Mechanism Using Water Vapor for Industrial Furnace

FAN WALL Technology. Product

A TRNSYS Simulation Case Study on Utilization of Heat Pump For both Heating and Cooling

CO 2 HEAT PUMP HEATING AND WATER HEATER SYSTEM FOR COLD AREA

The Revised Method of Test for Residential Water Heating and Its Impact on Incentive Programs

COOLING OF DESKTOP COMPUTER USING HEAT PIPES

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Continuous Commissioning: A Valuable Partner to Retrofit Projects

Performance of Solar Water Heating Systems in the United States

FORM ACCL-PC1 ACCL WITNESS TEST PROCEDURE AND CHECKLIST

Energy Efficient Options for Residential Water Heating

PREMIER SERIES APARTMENT HOUSE SIZING

Warehouse Protection of Exposed Expanded Group-A Plastics with Electronic Sprinkler Technology

Optimal Use of Air Conditioner

Selecting a New Water Heater

Julie Klump, POAH Rick Fenuccio, Tom Hartman Marc Rosenbaum Melpet preliminary heat loss and energy model results and implications

Transcription:

Development Of A Low-Cost Heat Pump Water Heater For Residential Applications Robert A. Zogg, Arthur D. Little, Inc., Cambridge, MA Edward Barbour, Arthur D. Little, Inc., Washington, DC Brian J. Nowicki, Arthur D. Little, Inc., Cambridge, MA John T. Dieckman, Arthur D. Little, Inc., Cambridge, MA ABSTRACT Air source heat pump water heaters (HPWHS) have been available in the U.S. since the early 1980s, but never reached annual sales greater than 10,000 units. While HPWHS can offer energy savings of as much as 67% over conventional electric resistance water heaters, their relatively high first cost has kept them from obtaining significant market penetration. In order to bring the energy savings benefits of HPWHS to the general water heating market, it is essential to substantially reduce the installed cost. This paper describes the development of a new heat pump water heater designed to provide reasonable energy efficiency at a substantially reduced first cost. Water heating simulations, conducted using the WATSIM analysis tool, showed that a significant amount of the typical consumer s hot water demand could be met using a reduced-capacity heat pump, with the balance of demand being met by supplemental electric resistance heating. Reducing the capacity of the heat pump offers several advantages including lower first cost and reduced impact on space heating. The goal of the present development effort was to substantiate a low-cost HPWH design approach in preparation for a broader product and market development initiative. The design approach was put into practice by modifying a conventional 300 liter (80-gallon) electric water heater. Proof-of-principle laboratory tests were successfully conducted verifying initial performance estimates. The prototype unit was then installed in a five-person household in New England for an extended field test. The unit reliably met the test family s hot water needs throughout the fall, winter & spring and continues to operate. Introduction Air-source heat pump water heaters (HPWHS) have been available in the U.S. since the early 1980s, but never reached annual sales greater than 10,000 units (see Figure 1). While HPWHS can offer energy savings of as much as 67% over conventional electric water heaters, their relatively high first cost has kept them from obtaining significant market penetration. In order to bring the energy savings benefits of HPWH S to the general water heating market, it is essential to substantially reduce the installed cost. Additionally, the product also needs to address other market barriers. Development Ofd Low-Cost Heat Pump Water Heater for Residential Applicdtiom -10.87

-r 1-1979 1981 1983 1985 1987 1989 1991 1993 1995 Year Fignre 1: Heat Primp Water Heater U.S. Sales History [1] Arthur D. Little, in conjunction with the U.S. Department of Energy, responded to the need for a low-cost residential heat pump water heater by identifying and substantiating a novel design approach. The concept makes use of the quick-recovery capability of electric resistance water heating and the high energy efficiency of a heat pump. The heat pump capacity is reduced in such a way as to maintain reasonable energy efficiency yet allow for substantial first-cost reduction. The following sections describe the design approach and results of the various methods of substantiating this approach including computer simulations, laboratory testing and field testing. Design Approach The design approach that was used involves adapting heat pump technology to the residential water heating industry. Since most consumers pay less attention to the actual energy efficiency of a water heater than to first cost, improving cost effectiveness rather than maximizing efficiency is necessary in developing a viable product. Figure 2 shows the effect of incremental reductions in the energy delivery efficiency of a heat pump water heater on operating cost savings. The savings are calculated relative to a conventional electric resistance water heater with a delivery efficiency of 86%. Delivery efficiency is represented by the energy factor, which for a water heater is calculated from the ratio of delivered energy to input energy and includes both the heat input efficiency as well as tank standby losses. Of particular note from the graph in Figure 2 is that a 23% reduction in energy factor (from 2.6 to 2.0) implies only a 15% reduction in the operating cost savings (from 67% to 57%). Yet by allowing for this reduction in energy factor, significant first cost savings can be achieved which actually improves the overall cost effectiveness of the unit. 10.88- Zogg, et. al.

70% 60% 50% 40% 30% 2o% 1o% 0% 0.75 1.00 1.25 1,50 1.75 2.00 2.25 2.50 2.75 Heat Pump Water Heater Energy Factor Figure 2: Sensitivity of Operating Cost Savings to HPWH Energy Factor Greyvenstein and Rousseau [2] demonstrated that the cost-effectiveness of commercial heat pump water heaters could be improved by maximizing the daily run time of the heat pump through size reduction. A similar reduced-capacity approach was employed to develop the present residential HPWH design. Reducing the capacity of the heat pump offers several benefits including: 1. Reduced system cost (with optimization of system components), 2. Lower negative impact on space heating systems (less by product cooling), 3. Increased heat pump run time through simultaneous electric resistance/heat pump operation which maintains reasonable overall delivery efficiency, and 4. Opportunity for simplified control system. Verification of the proposed design approach took several forms including computer simulations, laboratory testing and, finally, field testing. The following three sections give the results of these endeavors. Computer Simulations A detailed water heating simulation program called WATSIM was used for the computer analysis. WATSIM was developed by the Electric Power Research Institute (EPRI) to simulate the performance of various types of water heaters including electric resistance, heat pumps and desuperheaters. It accounts for such parameters as tank size, insulation, water circulation and mixing induced by water inlet and outlet flows, electric resistance heat inputs and heat pump performance. Development of a Low-Cost Heat pump Water Heater for Residential Applications -10.89

Figure 3 below is an example of an initial simulation performed using WATSIM to observe the effect of reducing heat pump capacity. The data shown is based on a 300 liter (80-gallon) heat pump water heater with supplemental electric resistance. The draw conditions are typical of a high-waterusing household in New York City (year-round average daily hot water use of 300 liter (80-gallon/day) at 21 C (77 F) temperature rise). The average annual entering water temperatures for each of the cities analyzed come from the EPRI Commercial Water Heating Handbook [3]. The graph shows that a heat pump with a capacity as low as 777 Watts (2650 Btu/hr) could supply roughly half of the annual water heating energy, with the balance being provided by electric resistance heating. It is also apparent that greater increases in heat pump capacity do not significantly increase the fraction of energy supplied by the heat pump. 4000 3500 = 3000 s g 2500 * 2000 3 * 1500 t 5 1000................................................................................................................................................................................. 500 0 191 381 586 777 967 1172 1348 1553 1729 1949 2902 3854 Nominal Heat-Pump Capacity (Watts) Figure 3: Effect of Reducing Heat Pump Capacity on Energy Use WATSIM was then used to simulate the performance of an electric resistance water heater (as a basis for comparison) and a heat pump water heater with a reduced-capacity of 970 Watts (3300 Btu/hr). Overall performance is judged by two parameters: delivery efficiency and energy defect. Delivery efficiency is the same as energy factor except that it applies to any type of water draw profile, as opposed to the prescribed profile used in U.S. Department of Energy s (DOE) Simulated- Use Test (see Figure 4). It is calculated by dividing the delivered energy by the required input energy. Energy defect gives the magnitude of hot water short falls as a way to approximate user satisfaction. It is expressed in units of energy (BTU) and represents the energy required to bring a deficient volume of hot water up to a useable temperature, which is taken to be 41 C ( 105 F). The electric resistance and heat pump water heater models were run for three different draw profiles. The first draw pattern used is shown in Figure 4 below and corresponds to the draw profile for the DOE test, which is used to determine the energy factor rating of water heaters in the U.S. The second and third draw patterns are based on actual real world profiles for an average size family (2.6 people) and a large family respectively, developed under a separate study [4]. Each of the real world draw profiles were run for a cooler-than-average climate (New York City) and a cold climate 10.90- Zogg, et. al,

(Minneapolis) in the fall and winter. Note that the daily average hot water consumption was adjusted for the various cities and seasons to account for inlet water supply temperature differences. I (Ea*dmwtotals10.7 gal., e.g.,3gpmfor3.57 min.) o 1 2 3 4 5 6 24 Time (hours) Figure 4: Water Draw Profile for the U.S. DOE Simulated-Use Test The results are shown in Table 1. The energy factor (at DOE test conditions) of the heat pump water heater was predicted to be 2.04, as compared to 0.84 for the conventional electric resistance water heater. The overall delivery efficiency predicted for actual use ranged from 1.74 to 2.46. The heat pump water heater delivery efficiency ranged from 1.9 to 3.2 times that for conventional electric resistance under similar draw conditions. While the heat pump water heater exhibited higher energy defect values than the electric water heater, these differences were not significant. Both water heaters could be expected to successfully meet the hot water demand in all cases except for a high water use day in the winter in Minneapolis. In practice, in many cases the user is not aware that an energy defect has occurred since it often happens during heavy water use by appliances such as dish or clothes washers. Based on these simulation results, we can conclude that our proposed reduced capacity heat pump water heater design could indeed achieve substantially higher energy efficiency than a conventional electric water heater while offering comparable utility to the consumer. Development of a LawCost Heat Pump Water Heater for Residential Applications -10.91

Laboratory Testing After obtaining promising results from the computer simulations, we put the design approach into practice. This was done by modi&ing a standard 80-gallon electric resistance water heater. The heat pump was integrally packaged with the water heater tank. The upper electric element was maintained for quick recovery capability. The lower electric element was de-activated. The prototype unit was subjected to two types of tests: a Performance Map Test and the DOE- Based Simulated Use Test. These two tests along with the final results are shown in Table 2. The results shown in this table were obtained after a series of design enhancements and adjustments. The laboratory testing substantiated the functional capability of the design to successfully heat water over the full temperature regime typical of residential hot water heaters. Further, the energy factor results correlated extremely well with the results of the computer simulations. Namely, the predicted energy factor of 2.0 was experimentally verified. range with heat pump only; Ambient Average Heating Rate = 1026 Watts Temperature = 21 C (3500 BTUH) DOE-Based Simulated Use Applied six water draws totaling 243 liters Measured Energy Factor = 2.0 Test (64.3 gallons). See Figure 4. Both heat pump and upper electric element operable. Field Test After positive results from both the computer simulations and the laboratory testing, it became necessary to test the reduced-capacity design approach under real-world operating conditions. A field test was undertaken, in which the prototype heat pump water heater was installed in a household in the greater Boston, MA area. The household consisted of two adults, two teenagers and one younger child. The family s existing hot water system, which was deactivated, consisted of an instantaneous 10.92- Zogg, et. al.

coil water heater inside a gas-fired space heating boiler with a 190 liter (50 gallon) storage tank. Figure 5 shows the prototype unit installed adjacent to the existing storage tank and boiler, in the basement. A PC-based data acquisition system was configured to record various temperatures (including the internal tank temperature and the hot water supply temperature), water consumption, and electrical power input of the heat pump. Two analog kilowatt-hour meters were also used to record the long term electrical consumption of the electric resistance element and the heat pump separately. The prototype began operation in October, 1996 and continues to operate. After the first few months of operation, the prototype was adjusted in order to optimize performance. The unit has remained unaltered since January, 1997. Table 3 gives a monthly summary of the data that was collected along with average values taken over the period from January to June, 1997. Existing Boiler Existing Storage Tank (no longer needed) HPWH Prototype Figure 5: Prototype Heat Pump Water Heater Installed at Field Test Site The results in Table 3 further substantiated the reduced-capacity design approach. The overall half-year average delivery efficiency of the unit was 2.01. It can be presumed that the full-year energy factor would be equal to or greater than 2.01, since the heat pump could deliver a greater fraction of the water heating energy in the warmer months that have yet to be sampled. The data show an average daily energy defect of 0.15 kwh (507 BTU). This is equivalent to only 3.03 liters @ 43 C rise (0.8 gallons @ 77 F). Most of these defects were probably not detected by the family since they probably occurred during machine water use. Also, the family did not express dissatisfaction with the unit, so it can be presumed that the unit met their hot water utility expectations. The larger defects that occurred during the winter months point out, however, that the heat pump capacity was somewhat undersized for the unusually high level of hot water consumption (570 liters/day, 150 gal/day) of the field test household. The sizing of the tank and heat pump relative to the expected hot water use thus become more critical for this reduced-capacity approach. Development of a Low-Cost Heat Pump Water Heuter for Residential Applications -10.93

Table 3: Summary of Field Test Data ConsumerEconomics Though the actual first cost of the heat pump water heater can only be known with greater certainty once the product development cycle is more complete, we have made some preliminary cost estimates. Our analysis indicates that a heat pump water heater designed according to the approach outlined above would have an installed cost premium of roughly $375 over a conventional electric resistance water heater, for all common residential tank sizes. Based on this cost differential, a preliminary consumer economics analysis was performed for low, medium and high hot water use applications in various cities in New England. The results of this analysis are presented in Figure 6. The payback is calculated for the case in which the consumer is faced with purchasing either a new standard-efficiency electric resistance water heater or a heat pump water heater, based on the proposed design approach. The values given reflect the actual marginal utility rates and entering water temperatures [3] of the cities shown. The graph shows that for moderate and severe hot-water-using households in each of the cities sampled, the payback period is about 1 year. This is due mostly to the fact that these cities have colder-than-average (for the U. S.) entering water temperatures and aboveaverage electric rates. The results indicate that it is cost effective for medium-to-large households to take advantage of the energy savings benefits of a heat pump water heater employing the reducedcapacity design approach. 10.94- Zogg, et. al.

H 80 GPD 60 GPD $3 40 GPD ~ Boston, NewYork, Hartford, Portland, Concord, Albany, CT MarginalUtility Rate :[120!iL47 $0,128?:133!%!143!J148 ($/Kwh) Figure 6: Payback to the Consumer When Choosing the HPWH Over Standard Electric Resistance Conclusions The first cost of residential heat pump waier heaters must be reduced in order to achieve a greater market presence in the U.S. A design approach aimed at reducing the system cost while maintaining reasonable energy efficiency is proposed. This concept centers around reducing the capacity of the heat pump, which could substantially reduce the cost. The design approach was substantiated through computer simulations, through laboratory testing and by field testing a prototype unit in a household in New England. All three of these methods supported the contention that a reduced-capacity heat pump could indeed provide a significant portion of residential water heating energy, yielding operating cost savings and successfully meeting users hot-water expectations. Caution, however, must be exercised in sizing the heat pump and hot water storage tank to properly match the hot water use in the desired application. The field test, for example, showed that when the average daily hot water use greatly exceeded the intended design, hot water short-falls did occur. Nevertheless, the design approach looks promising, and, therefore, further design, analysis and test is warranted. Development of a Low-Cost Heat Pump Water Heater for Residential Applications -10.95

Acknowledgement The authors wish to thank the support of the Department of Energy; Office of Building Technology, State, and Community Programs; Office ofbuilding Equipment. The authors would also like to thank John Ryan, DOE and Jim Brodrick, D&R International, for their guidance during the development of this paper. References [1] [2] [3] [4] Barbour, C.E., et al. 1996. Market Disposition of High Eficiency Water Heating Equipment. Prepared for U.S. Department of Energy, Washington, D.C., U.S.A. Prepared by Arthur D. Little, Inc. Greyvenstein, G. P. and Rousseau, P.G. 1996. Improving the cost effectiveness of heat pumps for hot water installations. Proceedings of the 5th International Energy Agency Conference on Heat Pumping Technologies, Volume II, pp. 55-65. Abrams, D.W. et al. 1992. Commercial Water Heating Applications Handbook. EPRI TR- 100212, Project 3169-01. Dieckmann, J.T., et al. 1994. Technical Analysis of the Proposed DOE Electric Heat Pump Water Heater Energy E#iciency Standard. Prepared for GAMA. Prepared by Arthur D. Little, Inc. 10.96- Zogg, et. al.