FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD

Similar documents
LAN/WAN OTDR FTB-7200 FTTx Access/Metro OTDR FTB-7200/7300 Metro/Long-Haul OTDR FTB-7400/74000 Long-Haul OTDR FTB-7500

Event dead zone: 0.8 m. Attenuation dead zone: 4 m. Dynamic range: up to 50 db. Platform compatibility. FTB-200 Compact Platform

AXS-100 Series HANDHELD OTDR. Telecom Test and Measurement

FastReporter 2 DATA POST-PROCESSING SOFTWARE

Extensive range of models covering all telecom testing applications. Flexible design, allowing up to three wavelengths in a single module

AXS-100. Series NETWORK TESTING OPTICAL HANDHELD OTDR. Compact, rugged, lightweight OTDRs optimized for access/fttx and LAN/WAN network testing

Connector Maintenance

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

Ensuring Cabling Performance in the Customer-Owned Outside Plant

Fibre Characterisation and FTTx New challenges

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

FTB-730 PON FTTx/MDU OTDR OPTIMIZED FOR ACCESS FIBER DEPLOYMENTS AND TROUBLESHOOTING

ENCIRCLED FLUX (EF) TEST SOLUTIONS

Intelligent Optical Link Mapper (iolm)

Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling

Ensuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications

ENCIRCLED FLUX (EF) TEST SOLUTIONS SPSB-EF LAUNCH MODE CONDITIONER AND FLS-600-NS1548 LIGHT SOURCE DESIGNED FOR CONTROLLED MULTIMODE LOSS TESTING

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks

Field Test Procedure for Optical Fibre Link Measurements

MINI2 MOST ACCURATE COMPACT OTDR

Fiber Optics for Todays Industry Applications

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

MTTplus Modular Test Platform

palmotdr Series Handheld OTDR

The Definitive Handheld OTDR for FTTx Testing OTDR AXS Compact, lightweight handheld OTDR optimized for access/fttx network testing

VIEW500 FASTEST STANDARD OTDR

Accelerating NBN fiber testing. Tom Ronan Marketing Lead Fiber Optics Melbourne

FTB-7400E Metro/CWDM OTDR METRO/CORE AND CWDM NETWORK FIBER CHARACTERIZATION

Attenuators. Fiber Optic Products Catalog. Singlemode Build Out Attenuators. Product Facts. Applications. Customizable Features. Available Collateral

OTDR II. Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling

Certified Fibre Optic Specialist - Testing

A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing.

MINI2. Inno Mini 2 Specs Provided by MOST ACCURATE COMPACT OTDR

The True Value of Connector Inspection: New Challenges and Best Practices

VIEW500 USER-FRIENDLY STANDARD OTDR

A Quick Start Guide to Fiber-to-the-Antenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification

Hands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing

VePAL FX300 Fiber Expert OTDR

Ensuring the Health of Tomorrow s Fiber LANs Part II OTDR Trace Analysis Become an Expert Troubleshooter with Advanced OTDR Trace Analysis

Hands-On CAT 5/6 & Fiber Optic Installer

The Rise of Tier 2 Testing

FLX380-30x FlexTester OTDR

palmotdr Series Handheld OTDR

FastReporter 2 DATA POST-PROCESSING SOFTWARE

Return loss measurement of fiber optic components

EXECUTING HIGHLY ACCURATE FIBER MEASUREMENTS IN A FRACTION OF THE TIME

FLX380-30x FlexTester3 OTDR

SECTION TESTING OF FIBER OPTIC CABLES

THE ENTRY-LEVEL SOLUTION DESIGNED FOR ALL YOUR TESTING NEEDS

MT-RJ Optical Fiber System Field Testing

FTB-720 LAN/WAN Access OTDR OPTIMIZED FOR MULTIMODE AND SINGLEMODE ACCESS NETWORK TESTING

FTBx-740C-DWC TUNABLE OTDR C-BAND DWDM METRO ETHERNET LINK CHARACTERIZATION

A Quick Start Guide to Fiber-to-theAntenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification

FastReporter 2 DATA POST-PROCESSING SOFTWARE

RLH Industries, Inc. Cleaning and Testing Fiber Optic Cable. Reference Guide MD A 0507

Kingfisher KI-3800 Light Source. Inexpensive handheld source for testing and commissioning optical fibre networks. Compact and rugged,

TROUBLESHOOTING AT THE SPEED OF LIGHT EMBEDDED OTDR FOR OPERATIONAL EXCELLENCE IN PASSIVE OPTICAL NETWORKS

SECTION TESTING OF FIBER OPTIC CABLES

This is a preview - click here to buy the full publication

MaxTester 730C PON/METRO OTDR OPTIMIZED FOR FTTx/MDU FIBER DEPLOYMENTS AND TROUBLESHOOTING, SUITABLE FOR METRO

AE2200 FTTx Multi-Function Meter

FG-750 Client API SDN-READY INTELLIGENT OTDR

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Essentials of Fiber to the Antenna: Fronthaul Installation Test

Fibre Specification Standards

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015

Noyes OFL 250B Specs Provided by

FTB-735C Metro/PON FTTx/MDU OTDR

M700-Series Multifunction OTDR

TECHNICAL - *All Pricing are Exclusive of VAT. Introduction to Fibre Optics for non-fibre Technicians (can also be done on-site) TARGET AUDIENCE:

FOT-930 MaxTester MULTIFUNCTION LOSS TESTER

Fibre (TIA) Field Test Specification

Basic Professional Fiber Optic Installation

FLX380 and OFL280 FlexTester Series

FTB-200. The Compact Platform Built for the Supertech COMPACT PLATFORM

FTS510 Series. Handheld OTDR Test Set.

OPTICAL TIME DOMAIN REFLECTOMETRY (OTDR) Dr. BC Choudhary Professor, NITTTR, Chandigarh

Intelligent Optical Link Mapper (iolm)

ECP OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS

Securing optical network physical layer with Fiber Monitoring and Management Vratislav Blažek Regional Sales Manager

OTP6123 Series. Handheld OTDR Test Set.

Product Specification

FTB/FTBx-740C-CWDM Tunable OTDR 18-WAVELENGTH CWDM OTDR FOR METRO ETHERNET AND C-RAN LINK CHARACTERIZATION

740C xwdm OTDR Series C-BAND DWDM AND 18-WAVELENGTH CWDM TUNABLE OTDR SERIES FOR METRO ETHERNET AND C-RAN LINK CHARACTERIZATION

Wilcom. Model FR2 Fiber Ranger Optical Fault Locator OPERATING INSTRUCTIONS

GO BEYOND OTDR LEAVE NO FAULTY NETWORK BEHIND. intelligent Optical Link Mapper

FTB-700 Series. OTDR for FTB-1. User Guide

MaxTester 730B FTTx/MDU PON OTDR

M700-Series OTDRs. or (800) , (603)

User Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014)

Yokogawa Meters & Instruments Releases AQ1200E, AQ1205A, AQ1205E, and AQ1205F OTDR Multi Field Testers

Connections You Can Count On.

Clearlite Photonic Fibers

OLTS vs OTDR Tier-2 Expert; How far from Tier-1?

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

DWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series

IDEAL INDUSTRIES, INC. USER MANUAL IDEAL OTDR

4120 Fire Alarm Network Reference

MicrOTDR. Optical Fault Locator. User Manual

Fibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC. Philip C Longhurst Corporate Fibre Optic R & D Manager

Transcription:

FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD 157 APPLICATION NOTE Mario Simard, Product Manager, Optical Business Unit The purpose of any fiber-optic network is to perform high-speed, error-free data transmission. Adequate testing during network installation minimizes costly and time-consuming troubleshooting efforts by locating faulty components before they disrupt service. This article discusses the main aspects of FTTH PON construction testing through real case studies. The object of this paper is not only to introduce the theoretical principles behind the test method, but also to show real test results obtained from typical networks operating in different conditions and exhibiting both normal and problematic circumstances. Construction Testing: Two-OLTS Method During the construction of an FTTH network, part of the testing occurs at the outside-plant level. This is when the distribution fibers need to be tested, as they are one of the last fiber links before the customer premises. CO Voice Data Optical Video Transmitter OLT WDM Coupler EDFA Splitter 1 x N Patch Panel Patch Panel Patch Panel. Although there are many ways of testing distribution fibers, the method described below uses two optical loss test sets (OLTSs). Here is an overview of its advantages and disadvantages: Advantages Accurate IL and ORL measurement Transposed fiber identification Bidirectional IL and ORL values Possible to test every distribution fiber Future-proof deployment Macrobend identification during testing is performed at 1550 and 1310 nm or at another combination of wavelengths, one of which is 1625 nm Disadvantages Two technicians required Communication required between technicians (when switching to another fiber) One technician needs to move from drop terminal to drop terminal In case of a cut fiber or macrobend, an OTDR is required to locate the fault

When using OLTS-based methods, it is important to follow the manufacturer s instructions to set the optical return loss (ORL) sensitivity of the test set and to reference the source and the power meter. Once this is done, testing can begin. The ORL measurement is crucial when dealing with high power such as analog video transmission. When the ORL is too high, it could have several undesired effects: Strong fluctuations in laser output power Potential permanent damage to the laser Interference at the receiver end Distortions in analog video signals Higher BER in digital systems This basic method involves using an OLTS that can share data between two test sets to measure insertion loss (IL) and ORL. First, ORL sensitivity must be set by calibrating the minimum ORL that can be measured by the unit. The limitation comes from the weakest part of the test setup, which would most likely be the connector between the units and reference test jumper. ORL sensitivity should be set on both units. SC/UPC to SC/UPC Reference test jumper Then, the two units should be referenced prior to measuring IL. SC/UPC to SC/UPC Reference test jumper SC/UPC to SC/UPC Reference test jumper At this point, measurements can be performed on the distribution fibers between the fiber distribution hub and the drop terminal. The purpose of this test is to identify the transposed fiber and measure the IL and ORL to make sure that the loss budget is met and the ORL is at an acceptable level.

Patch Panel Measuring distribution fiber IL and ORL using a pair of OLTSs When a fault is identified (other than a transposed fiber) the OLTS will be replaced by the OTDR to not only identify the fault but locate it as well. Testing the Feeder Fiber and Newly Activated Splitter Modules The other part of the outside plant to be tested is the feeder fiber. This could be done with either an OTDR or an OLTS. CO Voice Data Optical Video Transmitter OLT WDM Coupler EDFA Splitter 1 x N Patch Panel Patch Panel Patch Panel. Testing the feeder fiber Since the feeder fiber indeed consists of a single fiber, this is a basic test. Using an OTDR, a single technician can perform the test from the CO, measuring IL and ORL. This test can also be performed by two technicians using a pair of OLTSs one at the CO, and one at the. When it is time to connect the customer, the drop fiber is installed and a test is performed during the activation using a PON power meter. Activation testing using a PON power meter

Testing at the Central Office At the central office (CO) itself, where all the fibers are installed, it is imperative to inspect all connectors with a probe to make sure that they are clean and in good condition. Damaged and dirty connectors can lead to very costly failures at the CO. A connector dirty with grease can appear to display acceptable IL, because the grease acts for a short period of time as an index-matching gel, minimizing the loss. But when the system is activated, this grease will have dried out, and with the high power involved (namely with video signals), it will carbonize on the endface of the connector. Ultimately, this problem can lead to the need to replace a connector on an expensive piece of equipment such as an EDFA. Not only can it generate considerable expenses in equipment replacement, but also in time and labor to find and fix the problem. Considering that a simple reflectance measurement could detect this problem during installation by displaying a high reflectance value for this specific connector, this major loss of time and money could easily be avoided. IL and ORL testing can be performed during the installation using a pair of OLTSs and the first distribution fiber testing method as described above. With different types of connectors at each end of the jumper (for example, LC, which is a small-form-factor connector with a smaller ferrule diameter than a standard SC connector), a different referencing method is needed. In this example, the test is on a combination of 20 ft jumpers with an SC/UPC connector and an LC/UPC connector at each end. First, the ORL sensitivity test is conducted on each unit: (LC/UPC) ORL sensitivity on the LC end of the reference test jumper ORL sensitivity on the SC end of the reference test jumper Next, the IL is referenced. This is where the technician has to decide between using an SC-to-LC bulkhead adapter in an effort to match the two different ferrule diameters (1.25 mm for the LC and 2.5 mm for the SC) or using a hybrid reference test jumper (LC to SC). In this case, the bulkhead adapters that were tested did not show good stability; it is very hard to align the two fiber cores correctly due to the different ferrule diameters. Therefore, we chose to work with the hybrid reference test jumper, which has no alignment problem as it allows an SC connector to be matched with another SC (the same for LCs) during the IL referencing.

(SC/UPC) SC/UPC to LC/UPC Hybrid reference test jumper (LC/UPC) IL reference using a hybrid reference test jumper There is also a way to verify if the connection is good between the two SCs and LCs by measuring the ORL. In our example, the ORL should be at a minimum of 50 db and close to 55 db, as it is specified for UPC connectors. The same procedure can be used to test other hybrid jumpers (SC/APC to LC/APC, APC to UPC, etc). The uncertainty increases by ±0.08 db for a UPC connector and by ±0.12 db for an APC connector. (SC/UPC) SC/UPC to LC/UPC Hybrid reference test jumper (LC/UPC) Case Studies In this section, we will examine four actual test cases. In all cases, end-to-end testing refers to tests performed with an OLTS. Feeder fibers were tested from the CO to the, and the distribution fibers were tested from the to the drop terminals. CO Voice Data Optical Video Transmitter OLT WDM Coupler EDFA Splitter 1 x N Patch Panel Patch Panel Patch Panel.

Situation #1 Construction activity was complete and end-to-end loss tests had been conducted from the serving terminal back to the CO. The installation technician had successfully activated broadband and telecom services at the customer s home. At that point, the customer requested that video services be added to the package, which prompted the installation technician to return and carry out this new task. First, using a PON power meter, the technician measured the 1550 nm signal level at the customer premises and found it to be almost 14 db too low. During the same set of tests, the 1490 nm signal was determined to be well within the expected level range. The installation technician referred the problem back to the construction technician, who checked levels from the serving terminal back to the demarcation point at the CO. They discovered that the 1550 nm signal level was low all the way back to the WDM equipment at the CO. The problem was then passed on to the CO technician, who used a standard optical power meter and found that the 1550 nm signal was low going back to the EDFA but normal at the EDFA optical port. The CO technician replaced an optical jumper between the EDFA and the WDM equipment and cleared the problem (i.e., the problem was not corrected until the EDFA and jumper were replaced). Inspection of the optical jumper revealed that it was dirty and had been damaged by the higher power levels transmitted by the EDFA. The debris had been carbonized by the optical signal and had created a hot spot on the jumper endface. The hot spot resulted in pitting of the jumper endface. Burnt connector Clean connector 1. Cleaning optical jumpers is imperative! 2. The presence of a normal 1490 nm signal coupled with an abnormal 1550 nm signal can only be determined by using a PON power meter. 3. Assessing problems with the appropriate instruments leads to fast resolution. Once it was determined that the 1490 nm signal was normal and the 1550 nm was abnormal, it was easy to conclude that the problem could be traced back to the central office. Situation #2 Construction activity was complete and end-to-end loss tests had been conducted from the serving terminal back to the CO. Installation technicians were unable to successfully provision broadband services. Using a PON power meter, they determined that both the 1490 nm and 1550 nm optical signals did not reach the customer location. They referred the problem to the construction technicians. Construction technicians used an OTDR at the serving terminal and determined that the F2 fiber (distribution fiber) was intact all the way back to the hub. They then moved to the, at the customer premises, and found that the drop fiber (the fiber between the serving terminal and the ) was shorter than expected. They replaced the drop fiber and successfully activated services. As it turns out, on the previous day, a contractor had installed a sprinkler system for the homeowner and had damaged the drop fiber. 1. Proper use of a PON power meter lead the technicians to the next logical step troubleshooting the physical layer (fiber). 2. Proper use of an OTDR revealed the location of the problem and enabled a quick repair. Situation #3 During the construction phase, it was found that an F2 fiber did not meet the end-to-end loss specifications for the 1550 nm wavelength, while the 1310 and 1490 nm wavelengths were within acceptable limits. Construction crews inspected the fiber with an OTDR and determined that there was a macrobend near the fiber distribution hub (). A macrobend normally exhibits a greater loss at a longer wavelength. Using a dual-wavelength OTDR is a great way of pinpointing a macrobend. Performing a trace comparison at 1310 nm and 1550 nm enables you to locate the macrobend.

Physical inspection revealed a pinched fiber behind the cross-connect panel of the. After rearranging the fiber to eliminate the sharp bend, all test results were within limits. 1. Thorough testing reveals problems before the customer experiences them. 2. Proper use of a dual-wavelength OTDR helped identify a problem that had no impact on broadband and telecom services but would have caused problems with video services. 3. End-to-end loss testing resulted in early detection of the problem and benchmarked the optical circuit for engineering records. Situation #4 End-to-end loss testing showed that the attenuation at all three wavelengths exceeded limits on an F2 fiber. Testing the F2 fiber with an OTDR did not allow technicians to detect any problems. The technician performed the end-to-end loss test again and found that the problem was still there. At this point, he inserted a 94 ft patchcord between the OTDR and F2 fiber and performed the test once more, which showed that the connector s reflectance value was very high. The technician then inspected the angled connector s endface with a video inspection probe to see that epoxy resin covered the core area very likely a manufacturing defect. Replacing the connector effectively solved the problem. 1. Testing from the beginning reveals problems before the customer experiences them. 2. When using an OTDR, always connect a launch fiber to fully characterize the link including the first connector. Conclusion Although it may seem to be an obvious conclusion, testing is essential; most importantly, it must be done right from the very start. Several testing methods exist, and selecting the most appropriate one depends mainly upon your specific constraints, whether they be economical or related to human resources or time. One constant remains, though: dirty connectors are your worst enemy. That s why each connector should be inspected prior to performing a test or a final connection to a network element. As far as test equipment, the OLTS and OTDR are the instruments that can help prevent, identify and address problems before transmission equipment is activated. Each segment of the network is important, as the network is only as strong as its weakest link. EXFO Corporate Headquarters > 400 Godin Avenue, Quebec City (Quebec) G1M 2K2 CANADA Tel.: 1 418 683-0211 Fax: 1 418 683-2170 info@exfo.com Toll-free: 1 800 663-3936 (USA and Canada) EXFO America 3701 Plano Parkway, Suite 160 Plano, TX 75075 USA Tel.: 1 800 663-3936 Fax: 1 972 836-0164 EXFO Europe Omega Enterprise Park, Electron Way Chandlers Ford, Hampshire S053 4SE ENGLAND Tel.: +44 2380 246810 Fax: +44 2380 246801 EXFO Asia 151 Chin Swee Road, #03-29 Manhattan House SINGAPORE 169876 Tel.: +65 6333 8241 Fax: +65 6333 8242 EXFO China No.88 Fuhua, First Road Shenzhen 518048, CHINA Tel.: +86 (755) 8203 2300 Fax: +86 (755) 8203 2306 Central Tower, Room 801, Futian District Beijing New Century Hotel Office Tower, Room 1754-1755 Beijing 100044 P. R. CHINA Tel.: +86 (10) 6849 2738 Fax: +86 (10) 6849 2662 No. 6 Southern Capital Gym Road Appnote157.1AN 2006 EXFO Electro-Optical Engineering Inc. All rights reserved. Printed in Canada 06/12