STERITITE INSTRUCTIONS FOR USE

Similar documents
SteriTite - The Container System of Choice SteriTite

SteriTite - The Container System of Choice SteriTite

SteriTite - The Container System of Choice SteriTite Instructions for Use

SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System

FLASH PAK STERILIZATION CONTAINER SYSTEM

AMSCO STERILIZATION CONTAINER SYSTEM User s Guide

Accessories. Maybachstraße. Symmetry Fax: Revised 10/15

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

Cleaning & Sterilization

CLEANING INSTRUCTIONS

Instructions for care, maintenance, cleaning and sterilization of Smith & Nephew orthopaedic devices

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

Best Practice Guidelines For Cleaning, Disinfection and Sterilization of Critical and Semi-critical Medical Devices

CONVENTUS CAGE TM - DR Procedure Instruments Instrument Tray. Equipment Cleaning and Sterilization

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

CLEANING AND HANDLING OF WRIGHT INSTRUMENTS

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)

Aesculap Implant Systems

RECOMMENDATIONS FOR CLEANING DEVICES

Made in USA. Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216, USA (904)

Instructions for Use Spinal Punches IFU

Integra Salto Talaris and Integra XT Non-Sterile Device Reprocessing. Instructions for Use. 4. Manual Cleaning Instructions

Operating / User Manual

EMAX 2 PLUS AND XMAX CLEANING AND STERILIZATION BASKET. Mechanical/Automated Cleaning and Sterilization Guide in a Variety of Applications

Steam Sterilization and Sterility Assurance in Health Care Facilities ANSI/AAMI ST79. Suzanne Latta, CSPDT. Education Materials Coordinator

PICNet CONFERENCE 2013

Purpose. Team Roles and Responsibilities. System Requirements. Instrument Processing Training

Device Reprocessing Checklist Scoring Matrix 1=low 5=high

Aesculap Implant Systems

Recommendations for cleaning, decontamination and sterilisation. devices

When you sterilize an instrument set, you know what the standards are.

2015 Myco Industries, Inc Fax:

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

AS Medizintechnik GmbH Sattlerstraße Tuttlingen Germany

Operator s Manual. Video Laryngoscope. ( Instructions for use ) Doc no: Revision 1.1 8th January 2013

User Guide for Reprocessing of the SUPER VIEW Wide Angle Viewing System Sterilizable Components and Accessories

Cleaning and Sterilization for Instruments & Posts

SUBJECT: Monitoring the performance of a sonic cleaners and/or automatic washers cleaning ability for lumens/cannulated items daily.

Cleaning and Sterilisation for Burs, accessories and filling material

IMPORTANT INFORMATION ON THE DEPUY SYNTHES

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

Central Sterile Services Department will receive, decontaminate, process, store and/or dispense sterile and non-sterile to departments requesting.

SBS Design Considerations for Autoclave Sterilization

AZTECA A LITRE STERILISER

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

EZ9Plus & EZ11Plus Instructions on: Operating

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches

Processing (cleaning, disinfection and sterilization) of instruments from Smith & Nephew Orthopaedics AG

Guidelines for Cleaning, Disinfecting and Sterilizing Medela Healthcare Products REPROCESSING GUIDE. Precious life Progressive care

SUGGESTED POLICY FOR THE MONITORING AN ULTRASONIC CLEANER DAILY

PERFORM Operating Document

STERILIZATION IS A KEY RESPONSIBILITY OF THE INSTRUMENT

Washer Test Kits User Guide

Electron Microscopy Sciences

Instruction Manual for the Revolutionary Science Saniclave

I.F.U Re/Processing Reusable Medical Devices

CENTRAL STERILISATION. Innovative, hardworking Sterilisation & Infection Control products perfect for your Central Sterile Supply Department

INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES

MARK-COSTELLO WASTE STERILIZER SPECIFICATION SHEET

AMSCO C Series Small Steam Sterilizers 16 x 16" (406 x 406mm) 20 x 20" (508 x 508 mm)

STERILIZATION IS A KEY RESPONSIBILITY OF THE INSTRUMENT

ANSI/AAMI ST79: Comprehensive guide to steam sterilization and sterility assurance in health care facilities. Suzanne Latta, CSPDT

Reusable Laryngoscope Blades and Handles


INSTRUCTIONS FOR USE & STERILIZATION FOR INSTRUMENTS

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

AUTOCLAVE STEAM STERILIZERS (BENCH TOP)

The Principles, The Process, and The Results:

idrive Ultra Powered Stapling System

V. Mueller. V. Mueller Reusable Devices: Cleaning and Sterilization Guide USA. Rx Only

THE BASICS OF DECONTAMINATION

HANDS-ON MODULE 5. CLEANING FLOW-i V3.0

Visao HIGH-SPEED OTOLOGIC DRILL CATALOG

Classification of Instruments -

Operator s Manual. Model G14TC-3 Disinfection Soak Station for Transesophageal Ultrasound Probes

Operator s Guide. Autoclavable Internal Handles with Integrated Paddles Rev. M

DIRECTIONS FOR USE. Keeping you insafehands to avoid needlestick injuries. see for demo video

Veterinary Autoclave

Operator s Manual. Model G17 Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

Advance Autoclave. Designed to give you more for your money with a high capacity for faster throughput: More features and benefits...

CASTLE 8666 LABORATORY GLASSWARE WASHING ACCESSORIES

WORK IN THE DISINFECTION ROOM WITH WASHER-DISINFECTORS

2364 Leicester Road, P.O. Box 175, Leicester, NY Phone (585) Fax (585)

Harvey Chemiclave 5000 Owner And Operator Guide

Processing Instructions. Cleaning so easy.

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

RAP-hip Hip stem extraction set

Fiona Collins Liliana Donatelli Andrew Smith

Sterling P1500 Washer-Disinf ec t or Acce s s or y Guide

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

ENDOSCOPE DECONTAMINATION : Where are we now!

Integrity 270 Integrity 270VP INTEGRITY STEAM STERILIZER INTRODUCTION

PINNACLE MONITOR FOR AUTOMATED ENZYMATIC CLEANING (AEC) PROCESS

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

Cleaning Verification

AMSCO Washer/ Disinfectors. Central Sterile Services DISCOVER POWERFUL WASHING WITH INCREASED EFFICIENCIES. One Integrated Approach to Healthcare.

KEY OPERATOR STUDY GUIDE

Transcription:

STERITITE INSTRUCTIONS FOR USE

If a rigid container system is used, the manufacturers instructions regarding set preparation and assembly should be followed. -ANSI/AAMI ST79: 2010 & A1:2010

Notes from ANSI/AAMI ST79 Not all packaging systems are suitable for all types of sterilization methods Some rigid container systems can only be used in a pre-vacuum steam sterilizer Some types may require increased drying time Certain chemical cleaners might be needed

Notes from ANSI/AAMI ST79 Paper-plastic pouches are not appropriate for use in wrapped sets or containment devices The weight of an instrument sets should be based on whether personnel can use proper body mechanics in carrying the set on the design and density of the instruments and the recommendation of the device manufacturer Recommended weight: maximum 25lbs

Decontamination Disassemble all components Remove the tray of instruments for decontamination Remove the filter retention plate, and discard the filter Place the filter retention plate in a basket for cleaning

Cleaning Steps Discard used filters, load cards and other disposables May be cleaned manually or in an automated washer or cart washer Use ph neutral detergents only Thoroughly rinse to avoid detergent residue To avoid water collection, place the container upside down for drying Dry thoroughly using a soft lint-free cloth or it will interfere with the sterilization process

Assembly for Use Place disposable filter over each perforated vent Latch the filter retention plate over the filter Place the lid on top of base Secure the closure by latching the lid to the base Push the bottom section of the latch over the lock holder

Assembly for Use Select the correct filter Paper or polypropylene filter for steam sterilization Polypropylene filter only for STERRAD Sterilization Polypropylene filter may be used for all sterilization methods except gravity steam Be sure all perforations in lid and base have a new disposable filter at each location

Assembly for Use Arrange the clean instruments in the basket Use the partitions, brackets and posts for tray organization and protection Place the basket into the base of the container Place the appropriate ID tags in the label holders Thread the tamper evident seal with indicator facing forward through the lock holder

Inspection Inspection criteria should be performed after each use Check gaskets for cleanliness and for nicks and tears Adjust the tension of the retention plate Verify that filter retention posts and label holders are secure Check that lid and base of container fit securely Be sure that each vent has a retention plate and a new disposable filter

Sterilizer Loading/Unloading Place container flat on the shelf All containers can be stacked for storage Some containers can be stacked in the autoclave Place linen items above containers

Post-Sterilization Allow for adequate cool down to minimize the potential of condensate formation within the sealed container Tip: Crack the door to allow for gradual temperature reduction Next, distribute as needed or place in sterile storage

SteriTite at Point of Use Before opening the container Confirm that the correct set has been selected Verify that tamper evident seals are intact Check the acceptability of the end point response

Point of Use Break open the seals, remove and discard Open the latches, the clasp will fall away from the container edge Remove the lid using the rings on top to avoid contaminating the contents of the container

Caution THE SET MUST BE REPROCESSED If the seal is tampered with If the disposable filter is missing If the indicator did not turn If moisture is observed If the container is compromised in any way

FlashTite, the Filter-less Option A sealed container system for immediate use steam sterilization Rapidly sterilizes instruments and medical devices in gravity displacement or pre-vacuum immediate use (flash) cycles Sealed transport with virtually dry loads Simply place the instruments in the FlashTite basket, seal, sterilize and transport sealed to point of use

FlashTite, the Filter-less Option Meeting all current requirements for safe and effective sterilization Meets AAMI and AORN parameters for closed flash sterilization Goes into the autoclave sealed and comes out sterilized and sealed Cleared with FDA 510k Complies with the Joint Commission s requirements for sealed immediate-use (flash) sterilization

FlashTite Decontamination All items utilized in immediate-use steam sterilization must be cleaned and dried prior to use including container systems The FlashTite container system should be cleaned with a neutral ph detergent only Rinse thoroughly after each use Dry all components

FlashTite Decontamination Set up SuperNova at the sink or a ph neutral detergent for manual cleaning and decontamination of items for immediate use, as well as the FlashTite container Always follow cleaning with a thorough rinse and dry

FlashTite Instructions for Use 1. Place FlashTite valve plate over each perforated area in lid and/or base 2. For gravity displacement steam, use only perforated bottom containers 3. FlashTite basket should be utilized to hold surgical devices in place FlashTite basket is designed to clear the vent in lid and base

FlashTite Instructions for Use Flash Rack for custom graphic trays The Flash Rack is a platform that offsets the valve plate in the base Utilize the Flash Rack as an alternative to the FlashTite basket if loaner/specialty trays are to be placed into the container

FlashTite Instructions for Use 5. Case Medical s chemical indicators for immediate-use steam are recommended for use in all SteriTite containers with FlashTite valves 6. Close the SteriTite container and sterilize. Valve will automatically open and close during the sterilization process Valve in Open Position Valve in Closed Position

Recommended Exposure & Dry Times For Pre-vacuum Immediate-Use: Minimum exposure time of 3 minutes for non-porous items, 4 minutes exposure for lumens and mixed loads For Gravity Displacement Immediate-Use: Minimum exposure time of 5 minutes for non-porous items and a minimum exposure time of 10 minutes for instrument sets, lumens and mixed loads Dry Time: 0-3 minute dry time in the autoclave for items processed in immediate-use steam sterilization depending on the degree of dryness required

Rules of Thumb for Immediate-Use Transfer container using a glove or dry towel Exposure and dry times may vary depending on size of load, type of device and condition of steam and sterilizer Start at the highest recommended exposure time (10 minutes in gravity) and reduce as needed No dry time is required, but 2 to 3 minutes will give you drier contents You may crack the door for gradual cool down Note: Do not use disposable filter with FlashTite valve

Verify Always verify in your hospital sterilizer Check that the correct cycle has been chosen That the appropriate container has been selected (perforated bottom container for gravity displacement steam) Use rapid readout BIs for routine verification and when implants are processed

Verifying the load with BIs and CIs

Contact Us: 19 Empire Blvd, South Hackensack, NJ 07606 Phone 201-313-1999 Toll-Free 888-227-2273 Please feel free to email us at info@casemed.com