P1195 DUAL TOURNIQUET MONITOR

Similar documents
USER MANUAL FOR OPERATING SYSTEM

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

CONTENTS USING THE LIGHTS KEY...31 NETWORK ALARMS...32 FAULT AND ERROR MESSAGES...33

AS DIGITAL FIRE PUMP CONTROLLER

Introduction. OM-THA2

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

VT4810 SINGLE / DUAL ZONE CONTROLLER INSTALLATION MANUAL

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

EXTINGUISHING AGENT RELEASE MODULE

CONTENTS INSTALLATION 21 USING THE SIGNAL KEY 10 SPECIFICATION 23

SECURIT 700L PLUS ENGINEERING MANUAL

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

P2267 NETWORK INTERFACE

Pipo Communications. Model ST-888. DTMF ANI/ENI Display Decoder

C2 Compact Range Installation & Programming Manual

DT968C C.T. BATH CONTROLLER

Smart Temp. ApolloP/n Installation Manual. Version 1.0

Door Release Power Supply

Dryer Controller M720

User Manual. Dryer Controller M720

AP Air Ion Counter Instructions

Specification/ Data Sheet

ENGINE MONITOR VOTT MODEL: YEAR WARRANTY

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Setting the Timer...

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

TIF9055 Programmable. Owner s Manual Manual del Propietario Manuel du propriétaire Benutzerhandbuch Manuale del proprietario

PROGRAMMING PROCEDURES (Table 3)

OPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN

Control/Communicator Installation Manual

Digiplex LED Keypads User s Manual

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

Checkout Procedure Manual

Solution 880 Operators Manual. Issue 1.00

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

Destiny Destiny Owners Manual

ANEP S-BOX EMERGENCY TELEPHONE FOR ELEVATORS.

MODEL 5800A CARBON MONOXIDE (CO) MONITOR AND ALARM SAMPLE-DRAWING TYPE

CORNELL Emergency Response Systems

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

CircuFlow Quick Setup Guide

AM-806. Waste/Door Radiation Monitor OPERATIONS MANUAL

MR-2602 Two Zone Fire Alarm Control Panel

Installation, Operating and Maintenance Manual

Addendum for STI-6406 with Dual Access Control

Model 1062 Environment Monitor

Emerald 3000 MK3 GJD010 Lighting Controller

SAT-3 Room Temperature Controller

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Operating instructions 2-channel code lock. Item No

DYGIZONE GJD910 Lighting Controller & Enunciator

Operation Guide 3408

ADE Gen4. Speech Dialler Engineering Information. Description. Features

ProTalk. Expander. Operating Manual Model B1292. July 28, 2009 Rev. 1.01

Analog Room Pressure Monitor RPC Series

Owner s Guide and. Gas Continuous Flow Water Heater 27L Gas Water Heater 874 & 872 Series, 627 Models

WARNING Important Safety Information

Suits all KPF849 models

SALT WATER CHLORINE GENERATOR. Model: SMC20TA & SMC30TA SMC INSTRUCTION MANUAL

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

Comfort System T-21-P Touchscreen Thermostat Installation Manual

Safety / Kit Components 1

AFA 500 FUME HOOD ALARMS

Indesit Company. Multiplo 2008 Jaeger Platform. Fabriano, May 2008

UVS & UVE REMOTE LAMP AIR DISINFECTION SYSTEMS OWNERS GUIDE

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

ZM20 OEM Technical Manual

Application, Installation, Operation & Maintenance Manual

7. Troubleshooting. General

C - B u s C - T o u c h U s e r s G u i d e C T Series

LeakSafe. solutions. WaterSwitch2. Installation Instructions

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

KELCO F29 PROGRAMMABLE FLOW SWITCH

Premier Hazard STC Instructions

BX444-Mc Gas Detector

ORP (mv) Controller Model: ORP-XP2. UP DOWN ENTER Time & Date Main Menu Alarm Reset

WARNING Important Safety Information

USER MANUAL CEF AP28 CONTROL PANEL

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

OVERVIEW ANNUCIATOR POINTS

TECHNICAL DATA OBSOLETE

K9 Heat Alarm Owners Manual HA-1520

XR401. Comfort Control TCONT401AN21MA. Owner s Manual. your local dealer (distributor) For more information contact. Tyler, Texas 75711

Solution Ultima Series Operators Manual ISSUE 1.00

USER MANUAL Digital CO Monitor Model CO30

Conventional Fire Alarm System 2014 V1.2

CPA6. Installation & User Guide. Intelligent Security & Fire Ltd. Compatible Equipment

Firehawk Deaf Alert. Installation and Maintenance. Version 16/8/2017 New Features

Premium 8 Zone Wireless Alarm Kit

LeakSafe. solutions. WaterSwitch2. Installation Instructions

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Transcription:

P1195 DUAL TOURNIQUET MONITOR USER MANUAL FOR OPERATING SYSTEM 22099-01 June 2001 Associated Controls (Aust) PTY. LTD. Unit A/30-34 Hilly St. Mortlake NSW 2137. PH (02) 8765 9911, FAX (02) 8765 9922 Page 1 of 9

Table of Contents 1. Introduction P1195 Introduction 3 2. Unit Description FRONT PANEL LEFT AND RIGHT 4 1) Pressure Regulator 4 2) Cuff Air Supply 4 3) Set Button 4 4) Timer Display 4 5) Pressure Display 4 FRONT PANEL COMMON 4 1) Alarm LED 4 2) Battery Low LED 5 3) Pk & mmhg LED s 5 INTERNAL CONTROLS 5 1) Power Connector 5 2) Timer Battery 5 3) Pressure Units Selection 5 4) Setup Button 5 5) Calibration Buttons 5 ERROR CONDITIONS 6 3. Unit Operation USE OF UNIT 7 INSTALLATION SETUP 7 4. Specifications Power Consumption 9 Environmental Conditions 9 Pressure Sensors 9 Timer Displays 9 Pressure Displays 9 Alarm Volume 9 Audio Signals 9 Battery Life 9 Battery Type 9 Page 2 of 9

1 Introduction P1195 INTRODUCTION The P1195 Dual Tourniquet Monitor is designed to set tourniquet pressure applied to two independent tourniquet systems, then monitor the pressures and sound an alarm should the pressures rise or fall outside preset limits. Minute timers are also run for each system with an audible reminder every 15 minutes of operation The audio system of the P1195 uses four different combinations of beeps and mixed frequency tones to indicate various events. The four combinations are:- 1 beep, 2 beeps, 3 beeps and a continuous triple mixed frequency signal as the alarm sound. The alarm condition has both an audible and visual component, while the 15 minute reminder has an audible component only. Both audible alarms share a common sound system. The volume of the alarms can be set to 1 of 8 levels, this is done internally at the time of installation. The Dual Tourniquet Monitor can display pressures in either kpa or mmhg. Selection is done internally and is set at the time of installation. Two green LED s on the front panel indicate which one has been selected. All timing is done via a realtime clock that runs even when the unit is turned off. When the unit is off, the clock is powered by an internal battery. This battery is constantly monitored when the unit is powered up and a red LED is provided on the front panel to indicate when the battery is considered too low to function properly. At this point the unit should be serviced and the battery replaced. Page 3 of 9

2 Unit Description FRONT PANEL The front panel of the Dual Tourniquet Monitor is divided into two sections, left (A) and right (B), there is also a small section in the centre containing indicators common to both sides. The left and right sides mirror each other and present the following items to the operator. 1) Pressure Regulator Used to adjust the pressure applied to the cuff. 2) Cuff Air Supply Connects air supply to the cuff. 3) Set Button Used to start the monitoring process. While held, it prevents the alarm from sounding as the cuff pressure is adjusted. As soon as it is released, the set pressure is memorised. Upper and lower limits of plus and minus 5 kpa on the set pressure are also memorised, providing the pressure is between 5 and 55 kpa. The timer is zeroed and the monitoring started. When the set button is operated, a single beep will be heard as an acknowledgment of operation. When released a single beep will be heard if the setup is acceptable, or a triple beep will be heard if pressure is outside the acceptable range. 4) Timer Display A 2-digit timer is provided to keep track of the number of minutes the tourniquet has been in operation. A double beep is sounded every 15 minutes of operation. Should the total time exceed 99 minutes, the display will flash 99 continuously. The 15-minute double beep will continue to operate every 15 minutes for up to 24 hours, after which it will cease. 5) Pressure Display A 3-digit display displays the cuff pressure in either kpa or mmhg. The upper and lower alarm points are plus & minus 5 kpa on the set pressure, hence the pressure range of 5 to 55 kpa because the lower limit can go to 0 kpa and the upper limit can go to 60 kpa, 60 being the absolute maximum pressure permitted. The common front panel area presents the following items to the operator. Page 4 of 9

1) Alarm LED This 15mm x 15mm red LED flashes whenever an alarm situation exists. 2) Battery Low LED This red LED will be illuminated when the internal battery that powers the timer is low and due to be replaced. 3) KPa & mmhg LED s One of these two green LED s will be illuminated indicating which units of pressure have been internally pre-selected for display. INTERNAL CONTROLS There are several setup items accessible to the installation technician from the rear on the unit. 1) Power Connector Power to the unit is connected via this terminal block. The Dual Tourniquet Monitor requires an external 12VDC @ 0.5A plug pack to power the unit. The connection is polarity conscience, however, a blocking diode has been incorporated to prevent damage to the unit should reverse voltage be applied accidentally. 2) Timer Battery This battery is a 3V button style, type CR2032. It should be replaced as soon as the low battery LED is illuminated. 3) Pressure Units Selection This 3 way pin block should have the centre leg linked to either one of the outer legs to select either kpa or mmhg as the desired pressure unit to be displayed. It is common to both left and right side displays. 4) Setup Button Providing a pressure cycle is not in progress on either side of the unit, operation of this button will step the unit through 2 setup states. The first state is to allow setting of the audible alarm level. The second state is to allow calibration of the pressure sensors. Detailed explanation of these states is given in the Unit Operation section on page 7. 5) Calibration Buttons Two sets of 2 buttons are provided to calibrate the pressure sensors, one set per side. Each set is used to let the unit learn the output reading of the associated sensor at two calibration points. These points are saves in nonvolatile memory and used to calculate the pressure reading from the sensor. Page 5 of 9

ERROR CONDITIONS All parameters set during calibration and running of pressure cycles are stored in non-volatile memory. This memory has a finite limit on the number of write cycles it will accept before failure. Many conditions influence the life expectance of this memory, in particular temperature. Even in the worst case conditions the memory has a life expectancy of many thousands of write operations. Should a failure occur, it may affect only one side or both sides of the unit. Whatever the case the affected side will flash Er on the time display and no pressure cycle can be initiated, the pressure display is unaffected. If such an error condition occurs, the unit should be serviced immediately. Page 6 of 9

3 Unit Operation USE OF UNIT For the description of the units operation only one side will be discussed, the other side operates in exactly the same manner. In its standby state the P1195 should be displaying 0 pressure with the time display blank. A small residual pressure up to 5 kpa can be present without the alarm sounding. In the standby state no timing takes place and no alarms will sound. To use the unit, place the tourniquet cuff as required. Hold the set button, the unit will beep once, then increase the pressure as required. Release the set button when the desired pressure has been reached, the unit will beep once if conditions are acceptable, or three times if they are not. If pressure conditions are acceptable, the timer will start from zero and count off the minutes. If the conditions are not acceptable, ie. the pressure is less than 5 or greater than 55 kpa the timer will remain blank, should the pressure be less than 5 kpa the alarm will not sound, if greater than 55 kpa the alarm will sound. If the pressure rises or falls by 5 kpa on the set pressure, an alarm will sound. To silence the alarm adjust the pressure back to the set point. Once the unit is running a double beep will be heard every 15 minutes of operation, this will continue for up to 24 hours. If the timer exceeds 99 minutes it will display 99 and flash. To disable the unit at the end on the cycle, hold the set button and reduce the pressure to zero, or at least to less than 5 kpa, then release the set button. The unit will beep twice and leave the display blank, it is now back to standby state. INSTALLATION SETUP There are several selections to be made at the time of installation. All adjustments are done within a simple setup procedure with the exception of the units of pressure. The units of pressure to be displayed is set via a 3 pin connector designated as CON1 and labelled as PRESSURE SELECT, use a shorting shunt to select kpa or mmhg as indicated on the PCB. All other adjustments are done under setup. To use setup, make sure no monitoring cycle is running, as this inhibits entering setup. Operate the setup button to enter Stage 1. Page 7 of 9

Stage 1 Stage 1 permits adjustment of the alarm volume. The top left hand timer display will show an A indicating alarm volume adjustment, the top right hand timer display is blank. The bottom left hand pressure display will show the timer battery voltage and the bottom right hand pressure display will show the current volume setting represented by a number from 1 to 8. The audible alarm signal is also turned on. Operation of the B side high & low pressure calibration buttons will adjust the volume up and down between 1 and 8, increasing and decreasing the audio level as it goes. When the desired level is set, pressing the setup button will save the value and turn off the audio signal as it steps to Stage 2 of the setup. Stage 2 Stage 2 permits calibration of the pressure sensors. The top left hand timer display will show a P indicating pressure sensor calibration adjustment, the top right hand timer display is blank. Both the bottom pressure displays will show current pressure readings. Calibration is performed by applying two accurately known pressure values to the sensors, these values being 0 and 50 kpa. Both A and B sensors have individual calibration buttons and can therefore be set independently. Note; pressure readings must be stable before saving them. When 0 kpa is being applied to one, or both, sensors, operation of the LOW A and/or LOW B buttons will save the output value being read from each sensor as the 0 kpa value, this will be reflected by displaying 0 in the appropriate left (A) and/or right (B) pressure display. Similarly, when 50 kpa is being applied to one, or both, sensors, operation of the HIGH A and/or HIGH B buttons will save the output value being read from each sensor as the 50 kpa value, this will be reflected by displaying 50 in the appropriate left (A) and/or right (B) pressure display. Operation of the setup button a third time will end the setup cycle and the unit will go back to standby state. The setup button can be operated to simply step through the stages to examine battery voltage and volume level without changing any settings. Note. The battery is considered low when it reads less than 2.2V. Anything below this value will turn the battery low LED on. Nominal battery voltage is 3V. The pressure sensors are calibrated at sea level before leaving the factory. However, a regular maintenance program is advised which should include checking the sensor calibration. Page 8 of 9

4 Specifications SPECIFICATIONS Power Consumption Operating Voltage 12 Volts DC +/- 10% Current Consumption 0.3 Amps Power Consumption 3.6 Watts Environmental Conditions Operating Temperature Range Operating Humidity Range 0-45 Deg C 95% R.H. non-condensing Pressure Sensors Maximum Pressure Connecting Tube 100 kpa 6mm. Timers Displays Two Digit 0 99 Minutes Pressure Displays Three Digit 0 100 kpa ( 0 750 mmhg ) Alarm Volume Adjustable in 8 steps Audio Signals 1 Beep Acceptance of a button or operation. 2 Beeps 15 Minute audible reminder. 3 Beeps Rejection of an operation. 3 Tones Mixed Continuously Alarm signal. Battery Life Unknown at the present time Anticipated to be several years. Battery Type CR2032 Nominal 3V Page 9 of 9