PM100/PM100E PLANTER MONITOR. Operator s Manual

Similar documents
Introduction... 1 System Overview... 1 System Diagram... 2

Introduction... 1 System Overview... 1 System Diagram... 2

The Vanguard System TM VM-2900 Air Seeder Monitor. Operator s Manual

SA SIREN AMPLIFIER

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

INSTALLATION AND INSTRUCTION MANUAL

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

SA VOLT SIREN AMPLIFIER

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 700

1-16 Row Population Monitor

OPERATION, SERVICE & PARTS MANUAL

Henny Penny Electronic Bun Warmer Model BW-1 Model BW-4 Model BW-4 Model BW-4/3 Model BW-6 Model BW-8

Model SS2000C31 SmartSystem Load Management System

Owner s Manual & Safety Instructions

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

Street Thunder ST240 SIREN AMPLIFIER INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

CD6102 / CD6102 OC / CD6102-2

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

LOUP II DRILL MONITOR OPERATION MANUAL. SOFTWARE v45

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

ion Genesis Pump Controller

Henny Penny Blast Chiller/Freezer Models BCC/BCR-140 Models BCC/BCR-175 Models BFR/BCR-350

FOSTORIA INDUSTRIES, INC North Main Street Fostoria, OH Phone: Fax:

460H INSTALLATION & OPERATION MANUAL REMOTE STROBE POWER SUPPLY IMPORTANT: 460H TM REMOTE STROBE POWER SUPPLY

Instruction Manual Hydraulic Crimping Tool

ImPress IRONING STATION

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Owner s Manual. Filterless UV Air Purifier. This Manual Includes:

PRO-TEC SYSTEM ONE. Trailer Security Systems Model # PTS-2. Photo includes PTS-2 with optional pager unit

INSTALLATION AND OPERATING INSTRUCTIONS. For Reliance Controls Emergency Power Transfer Switch Kit Model Number 30216BRK

RK-05 Combustible Gas Transmitter Operator s Manual

2-Port alarmcharge Hub - Manual

Model SS2000SS Series ELECTRONIC SIREN AND LIGHT CONTROL SYSTEM (with Slide Switch Control Head)

Projection Alarm Clock USER GUIDE

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

OPERATION, SERVICE & PARTS MANUAL

DryAire DRYING CABINET

IMPORTANT SAFETY INFORMATION:

IMPORTANT SAFETY INFORMATION:

PRACTICAL USER S GUIDE FOR THE ELECTRIC STOVE

User s Manual and Operating Instructions

Carson Manufacturing Co., Inc North Rural Street Indianapolis, IN Phone: (888) Fax: (317)

OPTIONAL SLIT TUBING RECOMMENDED (AVAILABLE AT MOST HARDWARE STORES) Violet Grey. +12v Dash Lighting (See Lighting Mode)

RK Combustible Gas Transmitter Operator s Manual

235H INSTALLATION & OPERATION MANUAL REMOTE STROBE POWER SUPPLY IMPORTANT: 235H TM REMOTE STROBE POWER SUPPLY

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Beacon 800 Gas Monitor Operator s Manual

DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL

IMpORTANT SAFETy INSTRUcTIONS

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

Smart IR Sensor. Installation and Operation Manual PNEG Date: PNEG-1640

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07

IMPORTANT SAFETY INFORMATION:

User s Manual and Operating Instructions

RK Transmitter Technical Notice

Model SS2000SM Series ELECTRONIC SIREN/LIGHT CONTROL SYSTEM WITH SignalMaster DIRECTIONAL LIGHT (with Slide Switch Control Head)

RK CO 2 Transmitter Operator s Manual

30 & 36 FLUSH-MOUNT GAS COOKTOPS

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR)

MICRO SWITCH NT Series

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

SSC-1D installation guide

MAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

20 High velocity Air

RK Carbon Monoxide Transmitter Operator s Manual

Propane Fume Detection System

Street Thunder ST280 SIREN AMPLIFIER & LIGHT CONTROLLER INSTALLATION AND OPERATING INSTRUCTIONS

IMPORTANT SAFETY INFORMATION:

PitBoss User Manual. Version /24/2013 Copyright 2013 PumpAlarm.com, LLC

Installation and Owner Man u al

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

Preamplifier Power Supply PPS-02 user's guide

Propane Fume Detection System With Solenoid Valve Control

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

6502B RF Distribution

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM

RK Carbon Monoxide Transmitter Operator s Manual

ELECTRIC FIREPLACE OWNER S MANUAL

REMOTE MOBILE SECURITY SYSTEM USER MANUAL

CabLite VR LED Lighting System Installation Manual

Non-Programmable Digital Thermostat

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

IMPORTANT SAFETY INFORMATION:

Instruction Manual. Nacho Cheese Dispenser and Warmer

RK Carbon Monoxide Transmitter Operator s Manual

M113S Users Manual. MERLIN STEALTH M113S Electric Fence Energizer GROUP OF COMPANIES. PDF created with pdffactory trial version

OWNERS MANUAL MODEL 451 (-101 & -201)

Installation Manual September Opticom Infrared System. Model 798 Emitter Bezel Mount Kit

User s Manual & Operating Instructions

SA SIREN AMPLIFIER WITH MECHANICAL TONE

Instruction Manual. Dogeroo, Super Dogeroo, and Mini Dogeroo

IMPORTANT SAFETY INFORMATION:

RK-05 Carbon Monoxide Detector Operator s Manual

Advantium 16 System Monitor

Transcription:

PM100/PM100E PLANTER MONITOR Operator s Manual

TABLE OF CONTENTS Safety Notices... 1 Introduction... 3 System Overview... 3 Installation... 5 Console Mounting... 5 Monitor and Power Connections... 5 Console Main Harness... 6 System Operation... 7 Display Panel... 7 Power Sequence... 7 Initial Startup... 7 Display Intensity... 8 Modes... 8 Monitor Mode... 8 Row Failure... 8 Alarm Mode... 9 Row Failure... 9 System Configuration... 11 Threshold Settings... 11 Seeding Rate Formulas... 13 Population in Seeds Per Acre... 13 Seed Spacing... 13 Troubleshooting... 15 PM100 Service Parts... 17 Monitor... 17 Planter Harnesses... 17 Planter Y Cables... 17 Planter Extensions... 17 PM100E Service Parts... 18 Monitor... 18 PM100E Monitor... 18 Planter Harnesses... 18 Warranty...19 i

TABLE OF CONTENTS ii

SAFETY NOTICES Safety notices are one of the primary ways to call attention to potential hazards.! This Safety Alert Symbol identifies important safety messages in this manual. When you see this symbol, carefully read the message that follows. Be alert to the possibility of personal injury or death. Use of the word WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Use of the word CAUTION with the Safety Alert Symbol indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Use of the word CAUTION without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in equipment damage. 1

2 SAFETY NOTICES

INTRODUCTION SYSTEM OVERVIEW The PM100 and PM100E are seed flow monitoring systems that provide indicators for row failure and low seed flow. Features include: Monitoring of 1-16 rows (PM100) and 1-8 rows (PM100E) Automatic sensor detection LED row indicators Dual function row failure indication - allows all LED s to blink while planting and turn off to indicate row failure, or may be set to illuminate to indicate row failure Adjustable failure threshold settings LED brightness adjustment Figure 1 INTRODUCTION 3

4 INTRODUCTION

INSTALLATION CONSOLE MOUNTING To mount the PM100/PM100E console, use the mounting bracket as a template for drilling. Mount the console in a location that is easy to view and easy to reach for threshold adjustment and alarm silencing. Figure 2 Console Mounting Before drilling, ensure that the power and main hitch harness can be routed in the proper manner. Harness retention and routing outside of the cab is also important. Do not use the enclosure as a guide when drilling. This may cause damage to the mounting bracket. MONITOR AND POWER CONNECTIONS Route the monitor harness to the rear of the tractor where the planter harness can be conveniently connected. Route the power leads of the main harness to the battery. Allow some slack to tie the harness off to the console bracket for strain relief and protection of the harness. Connect black lead to negative (-) battery terminal and red lead to positive (+) terminal. Route battery leads away from alternator, battery cables, spark plugs and other magnetic field sources. INSTALLATION 5

IMPORTANT: Be sure harnesses are not pinched, kinked or positioned against sharp edges and cannot be stepped on. Figure 3 Monitor And Power Connections Red Black + - 12 Vdc IMPORTANT: The seed monitor is designed to operate on 12 volts DC only. Always connect red lead to positive (+) battery terminal and black lead to negative (-) terminal regardless of whether tractor has a negative or positive ground system. CONSOLE MAIN HARNESS Insert the connectors of the harness into the mating connectors located on the console bottom. Each connector is different and may only be inserted into its mate. Figure 4 Main Harness Connection Main Console Harness Power 12V - Red Ground - Black Route the main harness to the rear of the tractor. Mount the harness to a suitable location at the rear of the tractor assuring the connector will reach the implement connector at the hitch. 6 INSTALLATION

SYSTEM OPERATION DISPLAY PANEL The monitor can be set in monitor mode or alarm mode. In monitor mode, the row indicator lamps will blink each time a seed is detected with a maximum of 20 seeds per second. In alarm mode, the row light will only illuminate when a row failure is detected. Figure 5 Display Panel Row Indicators Power Indicator Lamp Minimum seeding rate settings Power/ Alarm Cancel Switch POWER SEQUENCE The Power Switch has three positions: Down - move the switch down to turn off monitor power. Center - move the switch to the center position to turn monitor power on. Up - push the switch up to the momentary position to silence the alarm or to change the mode during power up. The +/- switch is used to set the minimum seeding rate settings. INITIAL STARTUP Move the I-O (power) switch to the center position to turn on the monitor. An indicator lamp in the right hand corner will illuminate while power is on. At power up, the monitor does a display test by illuminating all row indicator lamps. The alarm will output a single chirp during the display test. The row indicator lamps will then be off until planting begins. The monitor automatically detects which sensors are connected. If a sensor is disconnected, the row indicator lamp corresponding to that row will not illuminate. To disable a row from being monitored, turn the monitor off by moving the power switch down. Unplug the sensor at the row unit. Turn the monitor back on and the row indicator lamp will be disabled. SYSTEM OPERATION 7

Figure 6 Power Up Indicator And Alarm Test 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 DISPLAY INTENSITY Once the unit has completed the self test, the light intensity can be changed. Move the power switch up to the momentary position to change the light intensity. Keep repeating the procedure until a desired intensity is reached. The alarm will chirp for each step and provide a long chirp if a minimum or maximum setting is reached. Once the dimmest setting is reached, the indicator will reverse and start to brighten. MODES MONITOR MODE In monitor mode, each time a seed is detected, the row indicator lamp will blink. The maximum blink rate is 20 times per second. Rows that are planting at a slower rate will appear to be less intense. Any row failure that is detected or seed application that falls below the established minimum threshold will be indicated by a row indicator lamp that is not illuminated. To set in monitor mode, toggle the I-O (power) switch from On (I) to Off (O) and back to On (I). All row indicator lamps will illuminate for two seconds. ROW FAILURE In monitor mode, if an ALL ROWS FAILURE is detected, none of the row indicator lamps will illuminate and the alarm will chirp eight times then silence. While planting, if one or more rows fail, the corresponding row(s) will darken and the alarm will sound. The alarm can be silenced by moving the I-O (power) switch up momentarily. The alarm will remain silenced until an ALL ROWS FAILURE condition occurs (typically at the end of a row), the row begins working again, or the monitor power is cycled. Figure 7 Example Of Row Failure - Monitor Mode Row Failure 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 8 SYSTEM OPERATION

ALARM MODE In alarm mode, rows indicator lamps are illuminated only when row failure is detected. None of the row indicator lamps will illuminate while planting rates on all rows remain above the established threshold. If a row falls below the established threshold, the indicator lamp(s) will illuminate and the alarm will sound. To set to alarm mode, toggle and hold the I-O (power) switch from Off (O) to On (I) to the upper position for one second. The monitor will blink and the alarm will sound, indicating alarm mode is enabled. Release the switch. ROW FAILURE In alarm mode, if an ALL ROWS FAILURE is detected, all rows will illuminate and the alarm will sound and then silence. If one or more rows fail, the corresponding row indicator lamp(s) will illuminate and the alarm will sound. The alarm can be silenced by moving the I-O (power) switch up momentarily. The alarm will remain silenced until an ALL ROWS FAILURE condition occurs (typically at the end of a row), the row begins working again, or the monitor power is cycled. Figure 8 Example Of Row Failure - Alarm Mode Row Failure 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 SYSTEM OPERATION 9

10 SYSTEM OPERATION

SYSTEM CONFIGURATION NOTE: Changing the tractor speed will change the seeds per second planting rate. An alarm will occur if the tractor speed decreases so that the seeding rate falls below the threshold setting. If the alarm sounds too often then change the threshold setting to the next lower setting. THRESHOLD SETTINGS If the actual seeding rate of a row falls below the threshold setting on the monitor, the row will fail and the alarm will sound. To set the threshold: 1. Power up the console and wait until startup is complete. 2. Refer to The Minimum Seeding Rate Table for desired threshold setting. 3. Set the threshold to 2/3 of the nominal planting rate. If the desired threshold is higher than the allowable setting, then set the threshold to the highest setting. 4. Momentarily hold the +/- switch in either the + or - position to change the threshold adjustment setting. The number of indicator lamps that illuminate indicate the threshold setting. Holding the +/- switch to the + position will increase the threshold setting. Holding the +/- switch to the - position will decrease the threshold setting. To calculate the minimum seeding rate in seeds per second refer to the Minimum Seeding Rate Table. Figure 9 Minimum Seeding Rate Table (Based on number of LEDs illuminated) PM100 PM100E Threshold Seeds/Second 1 1 2 seeds every second 2 2 3 seeds every second 3 3 4 seeds every second 4 4 6 seeds every second 5 5 8 seeds every second 6 6 12 seeds every second 7 7 20 seeds every second 8 8 30 seeds every second 9 40 seeds every second 10 50 seeds every second 11 60 seeds every second 12 70 seeds every second 13 80 seeds every second 14 100 seeds every second 15 120 seeds every second 16 150 seeds every second SYSTEM CONFIGURATION 11

12 SYSTEM CONFIGURATION

SEEDING RATE FORMULAS Use the following formulas to determine the threshold in seeds per second. IF POPULATION IN SEEDS PER ACRE IS KNOWN Seeds per second = P x R x V / 360000 P = Population in seeds per acre R = Row width in inches V = Tractor speed in miles per hour EXAMPLE: Population is 30000, Row width is 30 inches, Tractor speed is 6 miles per hour Seeds per second = P X R X V / 360000 Seeds per second = 30000 x 30 x 6 / 360000 Seeds per second = 15 2/3 of 15 = 10 Set the threshold on the monitor to 2/3 of the nominal seeds per second or round down to the next setting. IF SEED SPACING IS KNOWN Seeds per second = 17.6 x V / S V = Tractor speed in miles per hour S = Seed spacing in inches EXAMPLE: Tractor speed is 6 miles per hour, seed spacing is 7 inches between seeds Seeds per second = 17.6 x V / S Seeds per second = 17.6 x 6 / 7 Seeds per second = 15 2/3 of 15 = 10 Set the threshold on the monitor to 2/3 of the nominal seeds per second or round down to the next setting. SEEDING RATE FORMULAS 13

14 SEEDING RATE FORMULAS

TROUBLESHOOTING NOTE: Do not replace fuse with one having a higher amperage rating, the console could be damaged internally. PROBLEM PROBABLE CAUSE CORRECTIVE ACTION Unit will not power on. No LEDs will illuminate during the power up sequence. Loose connection between power harness and monitor. Bad fuse. Defective power harness or monitor. Bad battery connection. Low system voltage. Make sure harness connection is centered and fully inserted. Make sure the power harness is properly connected to the monitor. Check the fuse in the power harness near the battery. If bad, replace with a 3A AGC fuse. Make sure the positive and negative connections of the power harness are not reversed. If the fuse is bad again, the power harness or the console can be faulty and require replacement. Contact your distributor or DICKEY-john Service Department at 1-800-637-3302. Check battery connections and make sure the connections are clean and tight. Make sure battery voltage is between 10 and 16 volts DC. TROUBLESHOOTING 15

PROBLEM PROBABLE CAUSE CORRECTIVE ACTION An indicator does not illuminate or the alarm does not sound during power up. One row indicator fails to flash when planting. Alarm sounds continuously. Seeds are being planted by row unit. Unit powers on, all LEDs illuminate, but no sensors are detected. Defective monitor. Defective seed sensor. Bad harness connection at the console or at the sensor that is intermittent. Defective sensor or harness wire that is intermittent. Harness is not properly connected. Defective (shorted) harness. Defective (shorted) seed sensor. Defective monitor. Contact your distributor or DICKEY-john Service Department at 1-800-637-3302. Clean sensing elements using a dry bottle brush. Some seed treatments require scrubbing with water and a commercial cleanser. Check harness connections at the console, hitch, and sensors. Check harness for pinched, worn, or broken elements. Swap the sensor with another row. If the problem moves, the sensor is faulty. Otherwise the harness or monitor could be faulty. Check harness connections at the console, hitch, and sensors. Check harness for pinched, worn, or broken components. Check sensors for pinched, worn, or broken wires. 1. Identify failed sensor by disconnecting all sensors and then reconnecting each sensor and cycle power to test. 2. Connect a suspect sensor in place of a known good sensor and cycle power to test. 3. Contact your distributor or DICKEY-john Service Department at 1-800-637-3302. Contact your distributor or DICKEY-john Service Department at 1-800-637-3302. 16 TROUBLESHOOTING

PM100 SERVICE PARTS MONITOR PM100 Monitor 46794-0111 Mounting bracket 46794-0080 Fuse, AGC 3A 20112-0049 Power harness 46794-0530 16 row cab harness 46794-0510 PLANTER HARNESSES Standard, 4 row 45841-0530 Standard, 6 row 45841-0550 Standard, 8 row 45841-0570 Standard, 12 row 45841-0590 Standard, 16 row 45841-1080 PLANTER Y CABLES Y-Cable, 8 row squadron 45968-0610 Y-Cable, 12 row squadron 45968-0960 Y-Cable, 16 row squadron 45968-0950 PLANTER EXTENSIONS Extension cable, hitch, 6 45841-0810 Extension cable, hitch, 15 45968-0320 Extension cable, hitch, 30 45968-0321 TROUBLESHOOTING 17

PM100E SERVICE PARTS MONITOR PM100E Monitor 46794-0110 Mounting bracket 46794-0800 Fuse, AGC 3A 20112-0049 Power harness 46794-0530 8 row cab harness, 10 pin Metri-Pack 46794-0520 8 row cab harness, 37 pin AMP CPC 46794-0500 PLANTER HARNESSES 37 Pin AMP CPC 10 Pin Metri-Pack 4 row harness 45841-0530 46794-0540 6 row harness 45841-0550 46794-0550 8 row harness 45841-0570 46794-0560 EXTENSION HARNESSES 45841-0810 (6 Ft) 46794-0570 (2m) 18 TROUBLESHOOTING

Dealers have the responsibility of calling to the attention of their customers the following warranty prior to acceptance of an order from their customer for any DICKEY-john product. DICKEY-john WARRANTY DICKEY-john warrants to the original purchaser for use that, if any part of the product proves to be defective in material or workmanship within one year from date of original installation, and is returned to DICKEY-john within 30 days after such defect is discovered, DICKEY-john will (at our option) either replace or repair said part. This warranty does not apply to damage resulting from misuse, neglect, accident, or improper installation or maintenance; any expenses or liability for repairs made by outside parties without DICKEY-john s written consent; damage to any associated equipment; or lost profits or special damages. Said part will not be considered defective if it substantially fulfills the performance expectations. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES OF MERCHANTABILITY, FITNESS FOR PURPOSE, AND OF ANY OTHER TYPE, WHETHER EXPRESS OR IMPLIED. DICKEY-john neither assumes nor authorizes anyone to assume for it any other obligation or liability in connection with said part and will not be liable for consequential damages. Purchaser accepts these terms and warranty limitations unless the product is returned within fifteen days for full refund of purchase price. For DICKEY- john Service Department, call 1-800-637-3302 in either the U.S.A. or Canada Headquarters: 5200 Dickey-john Road, Auburn, IL USA 62615 TEL: 217 438 3371, FAX: 217 438 6012, WEB: www.dickey-john.com Europe: DICKEY-john Europe S.A.S, 165, boulevard de Valmy, 92706 Colombes France TEL: 33 (0) 1 41 19 21 80, FAX: 33 (0) 1 47 86 00 07 WEB: www.dickey-john.com 2017 DICKEY-john Specifications subject to change without notice.

PM100/PM100E PLANTER MONITOR DICKEY-john Sales 800-637-2952 agsales@dickey-john.com DICKEY-john Technical Support 800-637-3302 service@dickey-john.com Europe Sales and Technical Support +33 1 41 19 21 80 europe@dickey-john.com Operator s Manual 5200 Dickey-john Road Auburn, IL 62615 www.dickey-john.com 217-438-3371 217-438-6012 fax 2017 DICKEY-john DICKEY-john, the DICKEY-john Logo and IntelliAg are registered trademarks of DICKEY-john.