Liquid Level Controllers

Similar documents
Auto Top-Off & Ultra-Precise Liquid Level Controller II

IMPORTANT! ank You! Model: Twist-In 100 GPD, 3-Stage RO Unit. Installation, Operation & Maintenance Guide

IMPORTANT! ank You! Model: Twist-In 100 GPD 4-Stage RO/DI Unit. Installation, Operation & Maintenance Guide

MKTF CRO-Series 5-Stage Reverse Osmosis System Installation and Maintenance Manual

Installation Instructions PP-AS20 Anti-Scale System

Alkaline RO System INSTALLATION MANUAL

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

INSTRUCTION MANUAL HS-229G

TL-105 COLUMN HEATER

ELECTRONIC FAUCETS INSTRUCTION MANUAL. Toll Free: (800) Haul Road Wayne, NJ krowne.

SOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual

MIGHTY PRO 1/4 HP CHILLER

INSTALLATION AND OPERATING MANUAL

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

OWNER S MANUAL & WARRANTY

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Murano Shower Cabin Installation Instruction

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

Karbon Kitchen Sink Tap

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

INSTALLATION & SERVICE MANUAL

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

Installation & Service Guide

User s Manual. Purity In Each Drop. Latest RO+UV technology Now at your home

Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50

aquamanta the experts in aquatic technology CH 025/050/100/ 150/200/300 NEW PHOTO Instruction Manual

Installation and Operating Instructions

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS

Model EPWHP. How to install, operate and maintain your Water Heater Protector. Do not return unit to store

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Owner s Manual. Pelican Custom Premium WHWF 1354/1665

WATERSHIELIJrM REVERSE OSMOSIS INSTALLA TION MANUAL ~ ~ ~ ~ ~ l ~ TO INSURE THIS PRODUCT AND THE INSTALLATION THEREOF. ~ ~ ~ ~ ~

REMOTE FAUCET PUMP SYSTEM

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

Power Pack Service Manual

Operating Instructions Manual. Condensate Separators. Models 4GNL3 thru 4GNL9 and 53RG84 thru 53RG95

Installation Instructions / Warranty. Metris 31060XX XX XX1

Power Pack Service Manual

Panel Mounted Heat Exchangers by Dantherm, Inc.

WHOLE HOUSE FILTER &

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

LITTLE BLASTER SET-UP INSTRUCTIONS FOR SHOT PEEN MACHINES WITH CARTRIDGE TYPE DUST COLLECTORS *** READ BEFORE OPERATING EQUIPMENT***

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

Installation Instructions / Warranty. Hansgrohe Single Control Kitchen Mixers

Installation Instructions / Warranty. Starck 10111XX XX XX1

ASSEMBLY INSTRUCTIONS

Instruction Manual Hydraulic Crimping Tool

KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER

InstructIon Manual KrEs EQuIPMEnt stands

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

ASSEMBLY INSTRUCTIONS

Professional Warming Drawer and Warming Drawer Cabinet

MariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120.

Installation Instructions / Warranty

ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER

INSTALLATION AND OPERATING INSTRUCTIONS FOR RW519 RAIN WATER FILTRATION SYSTEM

Installation and Operating Instructions for Microlene Underbench System

Comfort Series Instant Hot Water System

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

OWNERS MANUAL MODEL EXTERMINATOR VS900 C/R BLACK VAPOR CLEANING SYSTEM SAFETY INSTRUCTIONS OPERATIONS CARE AND MAINTENANCE TROUBLESHOOTING WARRANTY

Green Water Systems OWNERS MANUAL. Includes: Installation Procedures, Warranties, Service & Operation Guidelines.

Installation Instructions / Warranty

INSTALLATION AND OPERATING MANUAL

1/24/01 SYLVANIA Process Heat THREADED INLINE HEATERS , , , , , ,

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 700

POWER PACK SERVICE MANUAL

PARTS OVERVIEW GO TO VAPAMORE.COM TO SEE THE MR-75 AMICO INSTRUCTIONAL VIDEO

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

Series RFII 5.6 K-factor. Flush II Concealed Pendent Sprinklers

RATIO:GUARD Model E-1S EC Monitor

INSTALLATION AND OPERATING MANUAL

AeroVent 3X Product Manual

USER GUIDE. This manual covers the description, cautions, operation and maintenance of Super Vac confined space electric ventilators CONTENTS

Power Pack Service Manual

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

SAFETY INFORMATION GO TO VAPAMORE.COM TO SEE THE MR-75 AMICO INSTRUCTIONAL VIDEO

USER S OPERATING AND INSTRUCTION MANUAL

POWER PACK SERVICE MANUAL

Owner s Manual. PIR-1 IR Learner

ASSEMBLY INSTRUCTIONS

Installation and Operating Guide Document No Vacuum Chambers Copyright 2017 Terra Universal Inc. All rights reserved.

Installation and Operation Instructions Luxury Towel Warmer Free Standing or Wall Mounted

Whole House Filter Model: WH-LD

KNHE30 SERIES WATER-TO-AIR HEAT EXCHANGER

WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis

OPERATING MANUAL/ INSTALLATION

TrueClean ToteCleaner

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

Users Manual. LAURUS Systems, Inc. - Ph: Fax:

Toll Free: Fax: Ibico Kombo Binder

MODEL 925W FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET

FLOW-THROUGH FURNACE HUMIDIFIER

Installation and Operations Manual

Whynter Portable Ice Maker 33 lb capacity - White

Transcription:

Liquid Level Controllers INSTALLATION MANUAL SpectraPure Inc. assumes no responsibility for water damage due to leaks. It is the user s responsibility to determine that the system is leak-free by monitoring installation for 72 hrs.. REV5 2015-09-29

TABLE OF CONTENTS Terms and Conditions 3 Installations Liquid Level Controller For Single Tank (LLC-S) 4 Installation for all RO and RO/DI Systems 5 Figure 1: Installation of LLC-S-115 on RO Systems 6 Figure 2: Sensor Tube On/Off Points 6 Installation Instructions for Float 7 Float Assembly 8 Figure 3: Installation of LLC-S-115 on RO/DI Systems 9 Figure 4: Installation of LLC-RM-115 9 Liquid Level Controller For Multiple Tanks (LLC-M) 10 Installation of LLC-M on RO and RO/DI Systems 11-12 Figure 5: Installation of LLC-M on RO Systems 13 Figure 6: Installation of LLC-M on RO/DI Systems 14 Power Liquid Level Controller (LLC-PH) 15 Installation Instructions for LLC-PH 16 Figure 7: Installation of LLC-PH 16 Solenoid Valve Controller (LLC-SVC-2FLT) 17 Installation Instructions for LLC-SVC-2FLT 18 Figure 8: Installation OF LLC-SVC-FS 19 Solenoid Valve Controller (LLC-SVC-2PS) 20 Pressure Switch Installation 21 Figure 9: Installation of LLC-SVC-2PS 22 Troubleshooting Guide 23 Warranty 24 COPYRIGHT 2005-2013 BY SPECTRAPURE INC ALL RIGHTS RESERVED No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise without the prior written permission of SpectraPure Inc. 2 SpectraPure Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281

TERMS AND CONDITIONS: 1. Shipping charges on units or parts submitted to our facility for repair or replacement must be borne by the registered purchaser. After repair or replacement, the factory will return the unit or part freight prepaid to the customer. 2. We assume no warranty liability in connection with our equipment other than as herein specified. 3. This warranty is in lieu of all other warranties expressed or implied, including warranties of fitness for a particular purpose. 4. We do not authorize any person or representative to assume for us any other obligation on the sale of our equipment. This is the exclusive remedy and liability for consequential damages under any and all warranties which are excluded to the extent exclusion is permitted by law. 5. Proof of original purchase date must accompany all warranty claims. 6. SpectraPure, Inc. Reserves the right to change prices without notice when necessary. All prices in the catalog are quoted in US dollars. 7. Claims for error in quantity or condition must be made within 10 days of receipt of material. SpectraPure, Inc. Will not be responsible for any claimed shortages not reported within 10 days. Returns other than warranty claims may be subject to 20% restocking fee. 8. SpectraPure, Inc. cannot be held liable for damage or loss to a shipment by a freight carrier. Check shipment for damage before acceptance or note on freight bill subject to inspection for concealed damage. Consignee must file claim. SpectraPure, Inc. will offer as much assistance as possible. 9. A complete credit check is required prior to shipping on a Net 30 or C.O.D. - CUSTOMER CHECK ACCEPTABLE basis. In the interim period during which credit references are being evaluated, all orders must be shipped C.O.D. - CERTIFIED FUNDS (cash, cashiers check or money order). 10. All returned checks (due to insufficient funds or closed accounts) will be subjected to a $25 penalty charge. 11. Invoices on Net 30 accounts not paid within 30 days of shipment will be considered delinquent and will accrue Finance charges at the rate of 1.5% per month (18% per annum). SpectraPure Inc. Fax 480.894.6109 Fax us toll-free 1.877.527.7873 E-mail: sales@spectrapure.com Visit us on the web www.spectrapure.com 3

LIQUID LEVEL CONTROLLER FOR SINGLE TANKS (LLC-S) The Single Tank Liquid Replenisher Systems are the most advanced means of controlling liquid levels on single reservoirs, and are ideal for replenishing evaporated water in aquariums or liquids in other constant level containers. An onboard air pressure-activated electrical switch opens a solenoid valve when the liquid level drops approximately 1 and closes it when the liquid level rises back to its original level. Research shows that the Single Tank Liquid Replenisher provides a significant advantage over conventional float and back-pressure activated automatic shutoff valves by maximizing the duration of membrane operation. This minimizes the build up of impurities due to membrane creep (the small amount of impure water that is a characteristic of the membrane at the onset of pure water production). All wetted components are constructed of inert and saltwater safe materials. Power is provided by a plug-in 24 volt AC (UL listed and CSA approved) transformer. The single reservoir model is provided with the controller, which includes a switched 24 volts AC outlet for controlling a booster pump or other 24 volt AC operated devices, compression fittings, and 5 feet of tubing for remote mounting of the sensor. If you choose to use a booster pump, replace this transformer with the transformer that is supplied with the booster pump. LEVEL CONTROLLER 24 V TRANSFORMER BACKUP SAFETY FLOAT SUCTION CUPS SENSOR TUBE 4 SpectraPure Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281

INSTALLATION INSTRUCTIONS FOR LLC-S ON ALL RO AND RO/DI SYSTEMS! 1. Locate the BLACK TUBING connecting the carbon filter housing to the RO membrane housing. Cut this tubing in half above the bracket and between the bracket and the membrane housing s input fitting. 2. Locate the port marked IN (or directional arrow) on the LLC BOX. and connect it to the black tubing that is still attached to the carbon filter housing. 3. Connect the loose end of the tubing that is still attached to the RO membrane housing to the other port on the LLC BOX. 4. Locate the transformer provided, insert the male connector into the female connector on the LLC BOX. 5. Locate the sensor tube with clear air line tubing attached to it and connect the loose end of the tubing to the 1/8" nipple on the side of the LLC Box. WARNING: Airline tubing MUST be connected to the 1/8" nipple on the back of the LLC Box BEFORE immersing the sensor tube in water. 6. Submerge Sensor Tube into water until you hear a click in the LLC Box. This is the turn off point. Mark that spot with a permanent marker. Slowly pull the tube out of the water until it clicks again. This is the turn on point. Mark it, too. (Refer to Fig 2 on Page 6). 7. Mount the sensor tube with the suction cups provided or by whatever means you prefer. Water will cover approximately half of the sensor tube when shutoff occurs. NOTE: A small dab of aquarium silicone sealant on each suction cup will prevent them from detaching. 8. Install the back up safety float at any convenient location which is slightly above the shutoff level of the LLC. Failure to install backup float will void any warranty and may cause property damage. (Refer to installation for float on page 7). 9. It is highly advisable that you provide and install a safety overflow to drain plumbing to protect against catastrophic flooding. NOTE: Turn on the water supply to the RO System before plugging in the transformer. SpectraPure Inc. Fax 480.894.6109 Fax us toll-free 1.877.527.7873 E-mail: sales@spectrapure.com Visit us on the web www.spectrapure.com 5

FIGURE 1: INSTALLATION OF LLC-S-115 ON RO SYSTEMS SOLENOID OFF WATER LEVEL SOLENOID ON The distance between the marks will be approx. 1" FIGURE 2: SENSOR TUBE (ON/OFF POINTS) 6 SpectraPure Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281

ADJUSTABLE FLOAT (comes with kits) INSTALLATION INSTRUCTIONS FOR FLOAT 1. Drill a 1/2" hole into your sump or reservoir: *If the thickness of the sump is too thick for the Float to install properly, you need to counterbore the hole. NOTE: If you are installing the Backup Safety Float onto an acrylic tank we recommend using a new Forstner Bit to reduce the chance of cracking the acrylic. 2. (REFER TO DIAG) Remove the Compression Nut from the float body. 3. Insert the 1/4" Blue Tubing into the 1/2" Compression Nut with the threads towards the end of the tube. 4. Unscrew the Nut from the float body. 5. Insert the float body and washer into the 1/2" hole and tighten the Nut, which securely tightens the float to the tank wall. 6. Push the Compression Nut towards the end of the tubing and screw the Compression Nut back onto the float body. 7. To tighten, use one 1/2" wrench on the flats of the plasic threads and another 1/2" wrench on the compression nut. SpectraPure Inc. Fax 480.894.6109 Fax us toll-free 1.877.527.7873 E-mail: sales@spectrapure.com Visit us on the web www.spectrapure.com 7

FLOAT ASSEMBLY THE SAFETY BACKUP FLOAT MUST BE INSTALLED. FAILURE TO DO SO WILL VOID ANY WARRANTY AND POSSIBLY CAUSE PROPERTY DAMAGE. Adjustable Float 8 SpectraPure Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281

FIGURE 3: INSTALLATION OF LLC-S-115 ON RO/DI SYSTEMS FIGURE 4: INSTALLATION OF LLC-RM-115 (-RM VERSION HAS SOLENOID SEPARATED FROM THE SENSOR BOX. CONNECT THEM WITH THE PROVIDED CABLE.) SpectraPure Inc. Fax 480.894.6109 Fax us toll-free 1.877.527.7873 E-mail: sales@spectrapure.com Visit us on the web www.spectrapure.com 9

LIQUID LEVEL CONTROLLER FOR MULTIPLE TANKS (LLC-M) The Multiple Tank Liquid Replenishment Systems are the most advanced means of controlling liquid levels on single or multiple reservoirs and are ideal for replenishing evaporated water in aquariums or liquids in other constant level containers. A sensitive air pressure switch opens a solenoid valve when the liquid level drops approximately 1" and closes it when the liquid level rises back to its original level. Research shows that the Multiple Tank Liquid Replenisher provides a significant advantage over conventional float and backpressure activated automatic shutoff valves by maximizing the duration of membrane operation. This minimizes the build up of impurities due to membrane creep (the small amount of impure water that is a characteristic of the membrane at the onset of pure water production). All wetted components are constructed of inert and saltwater safe materials. Power is provided by a plug-in 24 volt AC (UL listed and CSA approved) transformer. The multiple reservoir model comes with a unit which includes a switched 24 volt AC outlet for controlling a booster pump or other 24 volt AC operated devices, compression fittings, 5 feet of tubing for remote mounting of the sensor, a Mini Bladder Tank, auto shutoff valve, ball valve, check valves and fittings, and one float valve for one additional reservoir. If you choose to use a booster pump, replace this transformer with the transformer that is supplied with the booster pump. The system may be expanded to include more reservoirs by adding the optional Float Kit (SPFK). For additional overflow protection, a secondary mechanical float is also included with every Multiple Tank Liquid Replenisher. (2) BACKUP SAFETY FLOATS AIR LINE SENSOR TUBE MINI BLADDER TANK ASO VALVE CHECK VALVES TRANSFORMER LLC CONTROL MODULE FITTINGS 10 SpectraPure Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281

INSTALLATION INSTRUCTIONS FOR LLC-M ON RO AND RO/DI SYSTEMS INSTALLATION OF THE AUTOMATIC SHUTOFF VALVE 1. Locate the Black Tube between the Carbon Filter and the Membrane and cut in half. 2. Insert the cut end from the Carbon Filter into the IN Port of the ASO Valve. 3. Insert the cut end from the RO Membrane Housing into the OUT Port of the ASO Valve. 4. Locate the Blue Tube (product water) that leaves the RO Membrane Housing. 5. Cut the Blue Tube 3" from the membrane housing. 6. Using the 1 lb Check Valve, reconnect the two cut ends with the arrow pointing away from the membrane. 7. Position the Blue Tube alongside the ASO Valve to determine where the blue tube needs to be cut. Then cut the blue tube and reconnect the two cut ends with the two remaining ports of the ASO Valve. (continued on next page) Flow Restrictor Inside Red Tubing To Drain Check Valve ASO Valve IN port OUT port Black Tubing from Carbon Filter Product Water in Blue Tubing to Reservoir, Bladder Tank, DI cartridge, etc. Note: In and Out ports are marked on ASO and must be aligned correctly for proper operation SpectraPure Inc. Fax 480.894.6109 Fax us toll-free 1.877.527.7873 E-mail: sales@spectrapure.com Visit us on the web www.spectrapure.com 11

INSTALLATION INSTRUCTIONS FOR LLC-M ON RO AND RO/DI SYSTEMS (continued) 8. Locate product line leaving the ASO Valve (for RO/DI system you will locate the line leaving the DI cartridge). Place a Tee on that line. (Refer to Figure 5 for RO systems or Figure 6 for RO/DI systems.) 9. Measure the lengths of blue tubing required to go to each reservoir and install them on each side of the Tee fitting. 10. Cut the line going to the secondary reservoir about one foot after the Tee fitting. Connect both ends of the tubing to the mini-bladder tank. 11. Cut the blue tubing about 3" after the mini-bladder tank and install the check valve with the arrow pointing towards the reservoir. 12. Connect the loose end of the blue tubing to the float valve on the secondary reservoir. (See pages 7-8 for float installation.) 13. Cut the blue tubing near the end that will connect to your sump. Attach the end of the tubing to the In port on the LLC box. Attach the smaller piece of tubing from the Out port of the LLC box to the Float Valve on the sump. 14. Locate the sensor tube with the clear air line tubing attached to it and connect the loose end of the tubing to the 1/8 nipple on the back of the LLC box. 15. Turn on the RO or RO/DI system. 16. Insert the male connector of the transformer into the female connector on the LLC box and plug the transformer into a wall outlet. 17. Submerge the Sensor Tube into the water until you hear a click in the LLC Box. Mark that spot with a permanent marker. Slowly pull the tube out of the water until it clicks again. This is the turn off point. (Refer back to Fig 2 on page 6). WARNING: Air line tubing MUST be connected to the 1/8" nipple on the back of the LLC Box BEFORE immersing the sensor probe in water. 18. Mount the sensor tube with the suction cups provided or by whatever means you prefer. The water level should be halfway between the two marks you just made. NOTE: A small dab of aquarium silicone sealant on each suction cup will prevent them from detaching. Make sure the wall of the sump or reservoir is clean and dry before applying the silicone adhesive. 19. Refer back to page 7 for the installation of Backup Safety Floats. Failure to install backup float will void any warranty and may cause property damage. WARNING: Floats are for bulk storage only and are not recommended for evaporation replacement. 12 SpectraPure Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281

FIGURE 5: INSTALLATION OF LLC-M ON RO SYSTEMS SpectraPure Inc. Fax 480.894.6109 Fax us toll-free 1.877.527.7873 E-mail: sales@spectrapure.com Visit us on the web www.spectrapure.com 13

FIGURE 6: INSTALLATION OF LLC-M ON RO/DI SYSTEMS (OPTIONAL) 14 SpectraPure Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281

POWER LIQUID LEVEL CONTROLLER (LLC-PH) (Used for turning on 120v AC pumps) The Power Tank Liquid Replenisher Systems uses a sensitive air pressure switch to energize or de-energize an AC outlet which can be used to switch a power head or a 115 volts pump up to 3 amps continuous duty. The unit can be set to turn a pump on or off with changing water level and is extremely useful for continuous water change systems. For Automatic replenishment of evaporated liquid on systems which require AC electrical control. Controls up to 3 amp continuous duty pumps and other 115 volts power heads. Extremely useful for continuous water change systems and other level control applications. POWER LEVEL CONTROLLER SENSOR TUBE WITH SUCTION CUPS CONNECT TRANSFER PUMP HERE TO AC WALL OUTLET SpectraPure Inc. Fax 480.894.6109 Fax us toll-free 1.877.527.7873 E-mail: sales@spectrapure.com Visit us on the web www.spectrapure.com 15

INSTALLATION INSTRUCTIONS FOR LLC-PH 1. Connect Power Level Controller to Transfer Pump and plug into an AC wall outlet. (As shown in Fig 7) 2. Locate the sensor tube with the clear air line tubing attached to it and connect the loose end of the tubing to the 1/8 nipple on the back of the LLC Box. 3. Submerge Sensor Tube into water until you hear a click in the LLC Box. Mark that spot with a permanent marker. Slowly pull the tube out of the water until it clicks again. This is the turn off point. (Refer back to Fig 2).! WARNING: Airline tubing MUST be connected to the 1/8" nipple on the back of the LLC Box BEFORE immersing the sensor probe in water. 4. Mount the sensor tube with the suction cups provided or by whatever means you prefer. The water will cover approximately half of the sensor tube when shutoff occurs. NOTE: A small dab of aquarium silicone sealant on each suction cup will prevent them from detaching. 5. It is highly advisable that you provide and install safety overflow to drain plumbing to protect against catastrophic flooding. FIGURE 7: INSTALLATION OF LLC-PH 16 SpectraPure Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281

SOLENOID VALVE CONTROLLER (LLC-SVC-2FLT) The Solenoid Valve Level Controller is a very powerful and reliable Level Controller. The solenoid is electrically activated when the low float becomes dry. Once the high float becomes wet, the solenoid turns off. The unit can be set to turn a pump on or off with changing water level and is extremely useful for continuous water change systems. If you choose to use a booster pump, replace this transformer with the transformer that is supplied with the booster pump. The Solenoid Valve Level Controller is available with any of four different solenoids, from 1/8" to 1", to accommodate different flow rates. NOTE: Floats are to be mounted horizontal when dry and float up when wet. In most instances we recommend locating the low float approximately half way down your reservoir. DO NOT OVERTIGHTEN when installing the floats. SpectraPure Inc. Fax 480.894.6109 Fax us toll-free 1.877.527.7873 E-mail: sales@spectrapure.com Visit us on the web www.spectrapure.com 17

Float Installation: 1. Install both the High and Low Floats onto an open container like a Rubber Maid TM trash can. The floats can be mounted by drilling a 5/8" hole. (The High Float shuts down the system, while the Low Float turns the system on). 2. Connect the floats to the Y-adaptor, then to the grey electrical extension cable and then to the 3-socket connector on the S.V.C. Solenoid Installation: 3. Install the solenoid between the carbon filter and the RO membrane. This prevents the solenoid from plugging up with sediment. (Arrow on Solenoid points in the direction where the water flows). 4. Connect electrical cable from the solenoid to the S.V.C. and then connect the transformer. Product Water Connection (optional item): 5. THIS KIT DOES NOT PROVIDE A MEANS TO CONNECT THE PRODUCT WATER TO A CONTAINER. A BULKHEAD FITTING CAN BE USED: 3/8" BULKHEAD FITTING: Use a paddle bit and carefully drill a 13/16" hole for installation at the top of the reservoir above the high level float. 1/4" BULKHEAD FITTING: Use a paddle bit and carefully drill a 5/8" hole for installation at the top of the reservoir above the high level float. 18 SpectraPure Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281

FIGURE 8: INSTALLATION OF LLC-SVC-FS SpectraPure Inc. Fax 480.894.6109 Fax us toll-free 1.877.527.7873 E-mail: sales@spectrapure.com Visit us on the web www.spectrapure.com 19

SOLENOID VALVE CONTROLLER (LLC-SVC-2PS) The Solenoid Valve Level Controller is a very powerful and reliable Level Controller for a pressurized tank system. The solenoid is electrically activated when the tank pressure is lower than the set point of the low pressure switch. When the high pressure switch activates, the solenoid turns off. If you choose to use a booster pump, replace this transformer with the transformer that is supplied with the booster pump. SVC TRANSFORMER SOLENOID PRESSURE SWITCHES CHECK VALVE 20 SpectraPure Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281

Pressure Switch Installation: 1. Pressure Switch Assembly is to be mounted inline with the product line tubing AFTER a check valve and BEFORE the storage tank. 2. If the product line tubing is larger than the 1/4" push fitting ports, an appropriate tee can be installed on the product line tubing and the 1/4" leg of the tee can connect to the Pressure Switch Assembly. Be sure to plug the other end of the Pressure Switch Assembly with a 1/4" plug. 3. Connect the 3-pin connector of the Pressure Switch Assembly, then to the (optional) grey electrical extension cable and then to the 3-socket connector on the S.V.C. 4. Install the solenoid between the carbon filter and the RO membrane. This prevents the solenoid from plugging up with sediment. (Arrow on Solenoid points in the direction where the water flows.) 5. Connect electrical cable from the solenoid to the S.V.C., then connect the transformer. SpectraPure Inc. Fax 480.894.6109 Fax us toll-free 1.877.527.7873 E-mail: sales@spectrapure.com Visit us on the web www.spectrapure.com 21

FIGURE 9: INSTALLATION OF LLC-SVC-2PS 22 SpectraPure Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281

TROUBLESHOOTING GUIDE Problems, Causes and Corrective Actions 1. LLC System not working (overflow, system not shutting off, etc.) a. Defective pressure switch i. Replace it. b. Water in the clear air line tubing c. Defective solenoid valve iii. Replace it. ii. Disconnect the tubing and blow air through it to get the water out. d. Dirt or corrosion on solenoid valve. 2. Solenoid will not turn on. iv. Clean or replace valve. a. Water pressure above 80 psi. i. Reduce pressure with pressure regulator. b. No power. ii. Check power outlet and transformer. SpectraPure Inc. Fax 480.894.6109 Fax us toll-free 1.877.527.7873 E-mail: sales@spectrapure.com Visit us on the web www.spectrapure.com 23

ONE YEAR MANUFACTURERS WARRANTY SpectraPure, Inc. warrants the product to the original owner only to be free of defects in material and workmanship for a period of one years from the date of receipt. SpectraPure s liability under this warranty shall be limited to repairing or replacing at SpectraPure s option, without charge, F.O.B. SpectraPure s factory, any product of SpectraPure s manufacture. SpectraPure will not be liable for any cost of removal, installation, transportation or any other charges which may arise in connection with a warranty claim. Products which are sold but not manufactured by SpectraPure are subject to the warranty provided by the manufacturer of said products and not by SpectraPure s warranty. SpectraPure will not be liable for damage or wear to products caused by abnormal operating conditions, accident, abuse, misuse, unauthorized alteration or repair or, if the product was not installed in accordance with SpectraPure s or other manufacture s printed installation and operating conditions, or damage caused by hot water, freezing, flood, fire or acts of God. SpectraPure will not be responsible for any consequential damages arising from installation or use of the product, including any water or mold damage due to flooding which may occur due to malfunction or faulty installation, including, but not limited to failure by installer to over- or under-tighten fittings, housings, and/or push-style fittings, or improper installation of push-style fittings. Consumable items such as prefilters and membranes are not covered under the two year warranty. SpectraPure warrants (prorated) the performance of tested SpectraSelect RO membrane elements only, for one year from date of receipt by the buyer, providing that the loss of performance was not caused by fouling, neglect or water conditions exceeding the feed water parameters listed in the applicable product manual (refer to detailed membrane warranty information). SpectraPure will, on confirmation of loss of performance during the warranty period, credit the prorated amount of the current catalog price of the element. The disposable filters and cartridges are not covered under the warranty. To obtain service under this warranty, the defective system or components must be returned to SpectraPure with proof of purchase, installation date, failure date and supporting installation data. Any defective product to be returned to the factory must be sent freight prepaid; documentation supporting the warranty claim and a Return Goods Authorization (RGA) number must be included. SpectraPure will not be liable for shipping damages due to the improper packaging of the returned equipment and all returned goods must also have adequate insurance coverage and a tracking number. SpectraPure will not pay for loss or damage caused directly or indirectly by the presence, growth, proliferation, spread or any activity of fungus, wet or dry rot or bacteria. Such loss or damage is excluded regardless of any other cause or event that contributes concurrently or in any sequence to the loss. We will not pay for loss or damage caused by or resulting from continuous or repeated see page or leakage of water, or the presence or condensation of humidity, moisture or vapor, that occurs over a period of 14 days or more. Fungus and fungi mean any type or form of fungus or Mycota or any byproduct or type of infestation produced by such fungus or Mycota, including but not limited to, mold, mildew, mycotoxins, spores, scents or any biogenic aerosols. SpectraPure will not be liable for any incidental or consequential damages, losses or expenses arising from installation, use, or any other causes. There are no expressed or implied warranties, including merchantability or fitness for a particular purpose, which extend beyond those warranties described or referred to above. * The one year limited warranty does not apply to consumable items, including but not limited to, filters and cartridges unless specifically stated above. 24 SpectraPure Inc. 480.894.5437 Call us toll-free 1.800.685.2783 2167 East Fifth St, Tempe, Arizona 85281