BURAN REFRIGERATION COMPRESSED AIR DRYER. UltraPleat Technology

Similar documents
UltraPleat Technology BURAN REFRIGERATION COMPRESSED AIR DRYER

Refrigerant Dryers Refrigerant Compressed Air Dryer with integrated DF Filters

BURAN OEM DC 0020 AB - DC 0850 AB

REFRIGERATION COMPRESSED AIR DRYER BOREAS VARIOPULSE

HEAT REGENERATED ADSORPTION DRYERS

HEATLESS REGENERATED ADSORPTION DRYER ULTRAPAC SMART

Refrigeration Compressed Air Dryer Boreas Variopulse

CONDENSATE MANAGEMENT

Buran DC DC 1175 AES / WB Air cooled / water cooled Refrigeration Dryers

Boreas DV DV AB / WB

Boreas DV DV AVS / WVS Air cooled / water cooled Refrigeration Dryers

BURAN BURAN. Refrigeration Compressed Air Dryers for volume flows from 20 to 850 m³/h

Dryer Systems Heatless Regenerating Adsorption Dryers

Dryer Systems. Breathing Air Units

Refrigeration dryers for energy efficient compressed air quality

INDUSTRIALS GROUP. Refrigerant Dryers. Innovative Compressed Air Treatment Solutions GDD Series

ULTRAPAC SMART ULTRAPAC SMART INDUSTRIES

HEAT REGENERATED ADSORPTION DRYERS

HEAT REGENERATED ADSORPTION DRYERS

ultra.dry heat regenerated adsorption dryer

ThermoStar Refrigeration Air Dryers

Oil / Water Separators Ultrasep Superplus N and Ultraaqua Autoclean

Dryer Systems Heatless Regenerating Purification Packages

Dryer Systems Heatless Regenerating Adsorption Dryers

Atlas Copco Adsorption Air Dryers. MD l/s / cfm

productdatasheet Compressed Air Refrigeration Dryer Efficient compressed air treatment Rev 01_0317 Page 1

Atlas Copco Adsorption Air Dryers. MD l/s / cfm

MODULAR COMPRESSED AIR PURIFICATION. ULTRAFILTER FRL.

Ingersoll Rand. Refrigerated Air Dryers. mb air systems ltd

Atlas Copco. Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-15 kw/10-20 hp)

Ingersoll Rand. Refrigerated Air Dryers

The Highest Quality Compressed air treatment Refrigerant dryers CFM 0.33 to 91.1 M/min

Compressed air preparation Compressed air storage Moisture management. Catalog #1

BOGE AIR. THE AIR TO WORK. Refrigerant Dryers RA Series

Dryer Systems Heatless Regenerating Adsorption Dryers

Product Data Sheet Refrigeration Dryer DFX

Buran. Cycling Refrigerated Compressed Air Dryer With Ultrapulse Control. Intelligent Energy Management

Atlas Copco. Refrigerant air dryers FX 1-21 ( l/s, cfm)

Product Data Sheet Refrigeration Dryer DFLO 66 (-W) bis DFLO 2400 (-W)

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-37 VSD+ (7-37 kw/10-50 hp)

Refrigerant air dryers. FD series ( l/s, cfm)

New standard in compressed air treatment, providing Energy Savings up to 99%

Rust, corrosion and leakages threaten even the best network. Only Quality Air Solutions. in optimal shape. air distribution

Atlas Copco. Heat-of-compression rotary drum dryers ND series ( l/s, cfm)

Modular Adsorption Dryers

COMPRESSED AIR TREATMENT COMPRESSED AIR DRYER

Filters & Centrifugal Separators

Dryer Systems Heat Regenerating Adsorption Dryers

Oil-injected rotary screw compressors GA GA

Adsorption Air Dryers

High-Capacity Cycling Refrigerated Compressed Air Dryer. RTM Series

Refrigerated Air Dryers. Catalogue

CDX Refrigerant dryers

COMPRESSED AIR TREATMENT COMPRESSED AIR DRYER

Refrigerant Dryers DS Series

QUALITY DRY AIR. Atlas Copco Air dryers SOLICITAR INFORMACIÓN MILLIE LÓPEZ ANTONIO ARROYO. FD refrigeration air dryer series Hz (477)

ingersoll rand refrigerated air dryers

ROTARY SCREW COMPRESSOR CSA 5,5-7, HP

Dryer Systems Heatless Regenerating Adsorption Dryers

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 5-11 (5,5-11 kw/7,5-15 hp)

Refrigeration Air Dryers ADQ. Capacity: m 3 /h

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 5-11 (5,5-11 kw/7,5-15 hp)

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-75 VSD+ (7-75 kw/ hp)

next generation R 1 cycling refrigerated compressed air dryers flow capacity: scfm ( Nm 3 /hr)

Product Data Sheet Refrigerant Dryer DFLO-ES 66 (-W) to DFLO-ES 660 (-W) with energy saving management

Dryer Systems Heat Regenerating Adsorption Dryers

Refrigerated Air Dryers

Easy dry line REFRIGERATION AIR DRYERS. With VSCC exclusive patented variable speed system

Refrigerated Air Dryers VF Series. DHT Series. Non-Cycling 10-2,000 scfm scfm

COMPRESSED AIR TREATMENT

OIL-INJECTED ROTARY SCREW COMPRESSORS GX 2-7 EP G 7-15 EL

Refrigeration dryers with Energy Saving Impulse Technology and Thermal Mass 0,3-27,0 m³/min Purifying your compressed air, increasing your efficiency.

PNEUDRI High Efficiency Compressed Air Dryers.

DEi COMPRESSED AIR & GAS TREATMENT. Purifying your compressed air, increasing your efficiency.

Fred Castle Way Rougham Industrial Estate Bury St Edmunds Suffolk IP30 9ND United Kingdom

Modular Adsorption Dryers

Downstream Equipment. Intelligent Air Technology

Noncycling Refrigerated Air Dryers Range AD 10 to AD 4000

DRYPOINT RA eco. energy competence. Drying. kleinen meets responsibility. The wie möglich greatest savings come from the energy that we don t use

HX Series. Compressed Air Dryers 10 to 2400 scfm. Setting a new standard in Quality and Reliability DRYMAX DRYMAX DRYMAX

AirCel. AG Aluminum. SH Steel. Industrial Filter Housings

AirCel. Cycling Refrigerated Compressed Air Dryers. RFC and DVF Series

Atlas Copco. Refrigerant Air Dryers FX Hz

Cold Energy Saver. Thermal Mass Cycling Refrigerated Air Dryers ( scfm)

SCK. Air Compressors SCK 3-40 & ALLEGRO 8-11

Refrigeration Dryers TG TI Series

COMPRESSED AIR TREATMENT COMPRESSED AIR DRYER

Spiralair SPR 2-30 TECHNOLOGY YOU CAN TRUST

Largo & Allegro. Air Compressors LARGO & ALLEGRO

COMPRESSED AIR. Ultrafilter Skandinavien ApS

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA / GA / GA VSD (11-37 kw/20-50 hp)

UltraDry s Features and Benefits

SCFM REFRIGERATED COMPRESSED AIR DRYERS. CRN Series

AirCel. Heated Regenerative Desiccant Dryers. AEHD Externally Heated, HRE Blower Purge, and HRS-L Zero Purge Series

Rollair. Air Compressors. Rollair 15-40E

Compressed Air System Products That Save Energy & Improve Operations. Dry, Clean Air for Sensitive Equipment. Refrigerated Air Dryers

NON-CYCLING REFRIGERATED AIR DRYERS. RNC Series

High Efficiency Compressed Air Dryers. Adsorption Dryers Classical System INTELLIGENT AIR TECHNOLOGY

High Efficiency Compressed Air Dryers. Adsorption Dryers Modular System INTELLIGENT AIR TECHNOLOGY

RNC Series SCFM Global Air Treatment

Transcription:

BURAN REFRIGERATION COMPRESSED AIR DRYER UltraPleat Technology

Plug & Play Design There is more to Compressed Air than just Compressing Air How the Buran functions Compressed air is an indispensable source of being pre-cooled in the air-to-air heat exchanger by operating and processing power in all areas of the outgoing cold compressed air. The pre-cooled industrial and technical production. The compressed air then passes through the refrigerant-to-air heat air is generated by raising the pressure of large exchanger where it is being further cooled down to volumes of ambient air. Usually this air contains the required pressure dewpoint. The moisture in harmful substances, such as dirt particles and the compressed air condenses out and gathers and moisture in the form of water vapour. The water discharges automatically. Finally, the cold dis- vapour condenses and can lead to operational charged air is being reheated by the incoming com- breakdowns and considerable but avoidable costs. pressed air. This saves energy and prevents any To prevent production downtimes compressed air moisture forming beyond the dryer in the com- must be clean, dry and oil-free. pressed air system. The cooling capacity of the The compressed air is being fed into the dryer and refrigeration cycle is being controlled by a hot gas bypass, which will assure secure functioning even during partial loading. Aluminium Heat Exchanger Compressed air outlet (warm & dry) Buran Refrigeration Compressed Air Dryers Air-to-air heat exchanger Compressed air inlet (hot & wet) Refrigerant outlet Refrigerantto-air heat exchanger The refrigeration compressed air dryers of the Buran range, dry the air to prevent condensation and corrosion damage. The dryers in a robust metal Refrigerant inlet housing are equipped with an integrated pre- and afterfilter inclusive electronic level controlled con- Demister densate drain and a dewpoint indicator. The aluminium heat exchanger includes three functions in one: air-to-air heat exchanger, refrigerant-to-air heat exchanger and electronic level controlled condensate drain. Hereby an especially compact design is achieved. Condensate The main feature of the Buran refrigeration compressed air dryer is the aluminium heat exchanger 2

Low Pressure Losses Efficient and Economical The efficiency of the utmost compact and space saving design is shown by the significant reduction of the differential pressure. Only a 400 mbar lower differential pressure with regard to 8,000 operating hours at a flow rate of 850 m³/h will already save 2, Euro per year (7 bar mains pressure, 90 kw of installed capacity, 8 Eurocent/kWh). This example shows that an investment into the optimization of the compressed air system amortises itself within a short time. The display shows all relevant information Energy Cost Savings through Reduction of Differential Pressure Easy Handling Annual savings in Euro 0 The robust Buran refrigeration compressed air 2500 dryers stand out due to the easy handling and ease of maintenance: 400 mbar less pressure loss 2000 1500 Space saving design, easy installation. No additi- mbar less pressure loss 1000 onal pipe installation of pre- and afterfilter required.* 200 mbar less pressure loss 500 100 200 400 500 All connections are accessible from one side 700 900 1000 Flow rate in m3/h connection, condensate drain and inspection A decrease of differential pressure by only 400 mbar saves up to 2, EUR per year. (with 8,000 operating hours/year, 7 bar mains system pressure, 90 kw installed capacity and 0.08 Euro/kWh) Savings with 400 mbar Savings with mbar (compressed air in- and outlet, electrical Savings with 200 mbar drain control) Good accessibility of the main components Reduced maintenance effort *(Buran I - III) Clear, easily visible Control Display The user-friendly control panel allows for the monitoring of the operating status at a glance: The dewpoint is clearly displayed with a 10 point LED indicator Easy LED display for the operating mode, an alarm and the function of the fan Adjustable dewpoint alarm Service display informs automatically about the forthcoming filter replacement An easy installation is guaranteed with all connections being located on one side 3

Technical Data Gehäuse Buran I III with integrated pre- and afterfilters Type Volume flow Pressure drop Power supply Power consumption Cooling air requirement Air connection Weight Dimensions mm m3/h m3/min bar V/Ph/Hz kw (50 Hz) m3/h BSP kg W H D DC 0020 AB 20 0.33 0.04-60 0.14 200 30 DC 0035 AB 35 0.58 0.04-60 0.17 200 31 DC 0050 AB 50 0.83 0.10-60 0.19 33 DC 0065 AB 65 1.08 0.13-60 0.24 36 DC 0085 AB 85 1.42 0.14-60 0.28 37 DC 0105 AB 105 1.75 0.28-60 0.28 37 DC 0125 AB 125 2.08 0.39 0.45 38 DC 0150 AB 150 2.50 0.15 0.47 63 DC 0180 AB 180 3.00 0.12 0.68 380 65 DC 0225 AB 225 3.75 0.18 0.76 380 76 DC 0 AB 5.00 0.36 0.71 76 DC 0360 AB 360 6.00 0.49 0.89 76 DC 0 AB 7.50 0.11 0.91 143 DC 0550 AB 550 9.17 0.15 1.11 1900 152 DC 0650 AB 650 10.83 0.32 1.40 1900 159 DC 0750 AB 750 12.50 0.25 1.34 2500 175 DC 0850 AB 850 14.17 0.33 1.70 3 192 Buran IV with electronic control (energy saving function) without filters > DC 1000 AX 1000 16.67 0.27 2.40 3100 177 DC 1175 AX 1175 19.58 0.29 2.56 2 180 DC 1350 AX 1350 22.50 0.21 2.80 2 185 DC 1500 AX 1500 25.00 0.25 2.95 2 190 DC 1650 AX 1650 27.50 0.26 3.10 2 196 Compressed air outlet Compressed air inlet Compressed air inlet Compressed air outlet H H T B B T Buran DC 0020 AB - DC 0850 AB Buran DC 1000 AX - DC 1650 AX Volume flow referred to the suction status of the air compressor (+20 C, 1 bar), with compressed air inlet temperature 35 C, operating overpressure 7 bar, ambient temperature 25 C, pressure dewpoint +3 C, measured at dryer outlet in accordance with ISO 7183, power consumption at ambient temperature +25 C, permitted inlet temperature: max. 70 C, Permitted ambient temperature: min. +2 C max. 50 C, max. operating pressure: DC 0020 AB to DC 0085 AB and DC 1000 AX to DC 1650 AX 16 bar; DC 0105 AB bis DC 0850 AB 14 bar, DC 0105 AB to DC 0850 AB 14 bar, higher pressure on request. Protection class IP 20, noise level: db(a) <70. All refrigeration compressed air dryers are equipped with an environmental-friendly refrigerant: DC 0020 AB to DC 0150 AB and DC 1000 AX to DC 1650 AX R134a; DC 0180 AB to DC 0850 AB R407C. Working overpressure bar (g) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 fp 0.60 0.70 0.80 0.88 0.94 1.00 1.04 1.06 1.09 1.10 1.12 1.14 1.15 1.16 1.17 C 3 5 7 10 Temperature of the cooling air or cooling waters C 25 30 35 40 45 50 ftpd 1.00 1.12 1.24 1.36 ftu 1,00 0,97 0,97 0,87 0,75 0,62 Compressed air inlet temperature C 30 35 40 45 50 55 60 65 70 fte 1,28 1,00 0,88 0,75 0,58 0,48 0,44 0,42 0,40 Corrected dryer capacity = Standard dryer capacity x fp x ftpd x ftu x fte 4

Benefits of the new Buran range Features and Benefits Integrated pre- and afterfilter (BURAN I-III) Compact & user-friendly Prefilter type V protects the air heat exchanger from Compact plug & play design oil and particle contamination Achievable compressed air quality according to Afterfilter UltraPleat M meets specified compressed air quality requirements ISO8573-1:2010 [2:4:2] (with usual impurity of compressed air) High separation efficiency of filter at low pressure drop Energy savings through low differential pressure Easy to service concept (service kits, service display, No additional installation effort for pre- and afterfilter easy access to components within the housing) required High Overload Capacity Aluminium Heat Exchanger In case of overload, the dryer will only switch off Low operating costs due to marginal compressed air at a dewpoint above approx. +20 C losses Potential free Alarm Signal No corrosion inside the heat exchanger due to contact with wet compressed air Economical operation and safe system installation in the compressed air network Hotgas Bypass Control (BURAN I-III) Connection to higher-level control possible Proven and reliable technology with easy handling Constant dewpoint even with changing loads Electronic level controlled Condensate Drain No compressed air losses due to condensate removal Increase of the Compressed Air Quality with Filtration With a pre- and afterfilter the quality of the compressed air is further increased. The filter protects the dryer by separating liquid water, particles and oil. The afterfilter meets the specified compressed air quality according to ISO 8573-1 which is required for the application. Compressor *validated according to ISO 12500-1 UFK-W DF-C Aftercooler Cyclone Separator Refrigeration Compressed Air Dryer Prefilter Afterfilter DF-V* DF-M* Buran Air Receiver Vessel Buran with integrated filters* 5

Everything from one Source Service with highest Expectations Our service is always nearby! With our technical The Solution for high Volume Flows service and support network throughout Europe, we Donaldson offers a comprehensive range of refrig- can routinely service your production systems as eration compressed air dryers to meet your specific well as provide on-site support whenever needed. needs. For high volume flows our engineering team developed an individual solution, which is tailored With one of our ser- to your operating parameters and fulfils highest vice requirements with regard to energy efficiency. centers you receive quick, costeffective and compe- Our Buran IV refrigeration compressed air dryers tent services for all (1,000 to 1,650 m³/h) with electronic control as well filtration applications as the Boreas (1, to 28,500 m³/h) and Brisa from one source. (10,500 to 50,000 m³/h) range are available for this purpose. Compressed Air Filtration Filters for Sterile Air, Steam and Liquids Refrigerant Drying Adsorption Drying Condensate Drains Condensate Purification Systems Process Air and Gas Processing Total Filtration Management Total Filtration Service Donaldson offers a wide variety of A compressive range of services espe- solutions to reduce your energy costs, cially designed to keep your production improve your productivity, guarantee at peak performance and at the lowest production quality and help protect the total cost of ownership. environment.. Please contact us: Donaldson Europe B.V.B.A. Research Park Building No. 1303 Interleuvenlaan 1 B-1 Leuven Belgium Phone +32(0)16 38 38 11 Fax +32(0)16 40 00 77 CAP-europe@donaldson.com www.donaldson.com GB 2016/3 Ultrafilter Technical alterations reserved (3/2016)